Skip to content

Invoke is a leading creative engine that uses image and video generation models to empower professionals, artists, and enthusiasts to generate and create visual media using the latest AI-driven technologies. The solution offers an industry-leading application interface, and serves as the foundation for multiple commercial products.

fix(models): stop recording FP8 Storage for a model whose loader ignores it

Alexander Eichhorn5dbd31decde8
diff --git a/invokeai/backend/model_manager/configs/factory.py b/invokeai/backend/model_manager/configs/factory.py
index 7e93c73184..8b41c57a61 100644
--- a/invokeai/backend/model_manager/configs/factory.py
+++ b/invokeai/backend/model_manager/configs/factory.py
@@ -187,7 +187,6 @@ from invokeai.backend.model_manager.configs.vae import (
from invokeai.backend.model_manager.configs.wan_t5_encoder import WanT5Encoder_WanT5Encoder_Config
from invokeai.backend.model_manager.model_on_disk import ModelOnDisk, read_safetensors_header
from invokeai.backend.model_manager.taxonomy import (
- QUANTIZED_MODEL_FORMATS,
BaseModelType,
ModelFormat,
ModelSourceType,
@@ -250,19 +249,38 @@ def _identified_default_settings(
settings_cls: type[SettingsT],
mod: ModelOnDisk,
override_fields: dict[str, Any] | None,
- fp8_storage_applies: bool,
+ # Quoted: `AnyModelConfig` is the union of the concrete config classes and is assembled further down
+ # this module. `Config_Base` would not do — it declares none of base/type/format, which only a concrete
+ # class does (enforced by `__pydantic_init_subclass__`).
+ config: "AnyModelConfig",
) -> SettingsT | None:
"""Layer the settings sent with an install, and FP8 Storage for a float8 denoiser, over the recommended defaults.
An install setting wins over detection in both directions. Fields the settings class does not have (a main-model
field sent along with a LoRA install) are dropped, since nothing would read them.
+
+ FP8 Storage is enabled only where the model's own loader implements it. It used to be enabled for any float8
+ denoiser whose format was not already quantized, which wrote `fp8_storage: true` onto records whose loader ignores
+ it -- a Wan fp8 install was told its weights were halved and then loaded at bf16 size. `fp8_storage_verdict` is the
+ same answer the loader gate and the API row give; see `load/fp8_capability.py`.
+
+ A request sent with the install is dropped for such a model rather than stored. The detail panel does not offer the
+ control where the loader ignores it, so a stored `true` would be a value nobody can see or clear again -- and the
+ Add Models flow has one FP8 Storage checkbox for whatever is being installed, so it is easy to send for a model
+ that cannot use it.
"""
requested = (override_fields or {}).get("default_settings") or {}
update = {
name: value for name, value in requested.items() if name in settings_cls.model_fields and value is not None
}
- if fp8_storage_applies and "fp8_storage" not in update and _denoiser_stores_float8_weights(mod):
+ # Imported here, not at module scope: `model_loader_registry` imports this module, so the reverse edge would close
+ # a cycle. Identification runs long after import time, and the import is a `sys.modules` hit after the first.
+ from invokeai.backend.model_manager.load.fp8_capability import fp8_storage_verdict
+
+ if not fp8_storage_verdict(config.base, config.type, config.format).supported:
+ update.pop("fp8_storage", None)
+ elif "fp8_storage" not in update and _denoiser_stores_float8_weights(mod):
logger.info(f"{mod.name}: denoiser weights are stored in float8, enabling FP8 Storage by default")
update["fp8_storage"] = True
@@ -889,7 +907,7 @@ class ModelConfigFactory:
MainModelDefaultSettings,
mod,
override_fields,
- fp8_storage_applies=config.format not in QUANTIZED_MODEL_FORMATS,
+ config=config,
)
case ModelType.ControlNet | ModelType.T2IAdapter | ModelType.ControlLoRa:
config.default_settings = _identified_default_settings(
@@ -897,8 +915,7 @@ class ModelConfigFactory:
ControlAdapterDefaultSettings,
mod,
override_fields,
- # A ControlLoRA is patched into its base model and never cast on its own.
- fp8_storage_applies=config.type is not ModelType.ControlLoRa,
+ config=config,
)
case ModelType.LoRA:
config.default_settings = _identified_default_settings(
@@ -906,7 +923,7 @@ class ModelConfigFactory:
LoraModelDefaultSettings,
mod,
override_fields,
- fp8_storage_applies=False,
+ config=config,
)
case _:
pass
diff --git a/tests/backend/model_manager/configs/test_identified_default_settings.py b/tests/backend/model_manager/configs/test_identified_default_settings.py
index fa035300ea..5f06cd2941 100644
--- a/tests/backend/model_manager/configs/test_identified_default_settings.py
+++ b/tests/backend/model_manager/configs/test_identified_default_settings.py
@@ -148,3 +148,53 @@ def test_an_install_setting_keeps_the_architectures_other_defaults(tmp_path: Pat
assert probed is not None and overridden is not None
assert overridden.model_dump(exclude={"fp8_storage"}) == probed.model_dump(exclude={"fp8_storage"})
+
+
+def _anima_lllite_adapter(path: Path, weight_dtype: torch.dtype) -> Path:
+ """The smallest file identification reads as an Anima ControlNet-LLLite adapter.
+
+ Chosen because its loader is one of the seven that declare they do not implement FP8 Storage, and
+ it is the cheapest of those to identify. No published LLLite adapter is float8 -- they are 8-66 MB
+ bf16 files -- so this one is synthetic on purpose: the subject is the wiring, not the file.
+ """
+ save_file(
+ {
+ "lllite_conditioning1.conv1.weight": torch.zeros(8, 3, 4, 4).to(weight_dtype),
+ "lllite_dit_blocks_0.down.weight": torch.zeros(4, 8).to(weight_dtype),
+ },
+ str(path),
+ )
+ return path
+
+
+def test_fp8_storage_is_not_enabled_for_a_model_whose_loader_ignores_it(tmp_path: Path) -> None:
+ """The float8 probe is not the whole question, and used to be treated as though it were.
+
+ A Wan fp8 checkpoint or an Anima LLLite adapter is float8 on disk, so identification enabled FP8
+ Storage; neither loader touched the setting, so the record promised half the memory and the load
+ delivered none of it. `AnimaControlNetLLLiteModel` now declares `NotApplicable`, and identification
+ asks (`load/fp8_capability.py`).
+ """
+ result = ModelConfigFactory.from_model_on_disk(
+ _anima_lllite_adapter(tmp_path / "lllite.safetensors", torch.float8_e4m3fn), allow_unknown=False
+ )
+
+ assert result.config is not None and result.config.type is ModelType.ControlNet, result.details
+ settings = result.config.default_settings
+ assert (settings.fp8_storage if settings is not None else None) is None
+
+
+def test_an_explicit_install_request_is_dropped_for_such_a_model_too(tmp_path: Path) -> None:
+ """Add Models has one FP8 Storage checkbox for whatever is being installed, so the request arrives
+ for models that cannot use it. Storing it would leave a value the detail panel no longer shows and
+ therefore nobody can clear; the install's other settings are untouched."""
+ result = ModelConfigFactory.from_model_on_disk(
+ _anima_lllite_adapter(tmp_path / "lllite.safetensors", torch.bfloat16),
+ {"default_settings": {"fp8_storage": True, "preprocessor": "canny_edge_detection"}},
+ allow_unknown=False,
+ )
+
+ assert result.config is not None, result.details
+ assert result.config.default_settings is not None
+ assert result.config.default_settings.fp8_storage is None
+ assert result.config.default_settings.preprocessor == "canny_edge_detection"