Open-source document signature platform. Not affiliated with DocuSign.
TypeScript
Requirements
Your user and functional requirements for SignuDoc in Part 11 mode. Each requirement has an ID that the traceability matrix and the operational qualification use. Remove any you don't need, and add your own with new IDs.
Document [ID], version [1.0], approved by [name, role, date].
System and records
| ID | Requirement | Part 11 |
|---|---|---|
| SYS-01 | The system makes accurate and complete copies of records, both readable (PDF) and machine-readable (CSV audit trail). | 11.10(b) |
| SYS-02 | Records stay retrievable for the whole retention period. They are not deleted by a timer or by a signer's data request. | 11.10(c) |
| SYS-03 | Only people with an account can reach the system's records. Only administrators can change settings or roles. | 11.10(d), (g) |
| SYS-04 | A computer-generated, time-stamped audit trail records the creation, sending, viewing, signing, declining, voiding and completion of each record. It also records who did each step, from where, and when (UTC). | 11.10(e) |
| SYS-05 | Changes to settings, roles, identity confirmations and signing locks are recorded with the old and new value, who made the change, and when. | 11.10(e) |
| SYS-06 | Audit trail entries cannot be changed without detection: each entry is chained by hash to the one before it, and the system can check the chain. | 11.10(e) |
| SYS-07 | Voiding a sent record needs a reason, and the reason is recorded. | 11.10(e) |
| SYS-08 | Signers sign in the order the sender set. | 11.10(f) |
| SYS-09 | A finished record is sealed so that any change to the file after signing is detectable. | 11.10(c), 11.70 |
| SYS-10 | Turning Part 11 mode off does not change the rules a record was sent under. | 11.10(f) |
Signers and signatures
| ID | Requirement | Part 11 |
|---|---|---|
| SIG-01 | Each signer signs with their own account, which belongs to one person and is not reused. | 11.100(a) |
| SIG-02 | A record is not sent unless an administrator has confirmed each signer's identity and recorded how, and each signer is named as the person confirmed. | 11.100(b) |
| SIG-03 | A signer whose identity confirmation is taken back, whose account's name or email address changed since it was confirmed, or whose email is no longer confirmed, cannot sign. | 11.100(b) |
| SIG-04 | The signer gives two components, email address and password, to open the record and again at each signature. | 11.200(a)(1) |
| SIG-05 | Each signature shows the signer's printed name, the date and time (UTC), and its meaning. The same information appears in the certificate. | 11.50(a), (b) |
| SIG-06 | The signer confirms the meaning of their signature before signing. | 11.50(a)(3) |
| SIG-07 | The signature is linked to its record, and the seal makes it impossible to copy onto another record undetected. | 11.70 |
| SIG-08 | Passwords are at least 15 characters long and are checked against known breached passwords. | 11.300(a), (b) |
| SIG-09 | After five wrong passwords in a row while signing, the account can no longer sign until an administrator unlocks it, and every administrator is emailed. | 11.300(d) |
Procedural requirements (met by your procedures, not by the software)
| ID | Requirement | Part 11 |
|---|---|---|
| PRO-01 | The install is validated before use and after each change. | 11.10(a) |
| PRO-02 | The people who build, run and use the system are trained and their training is recorded. | 11.10(i) |
| PRO-03 | People are held accountable for actions under their signatures, by written policy. | 11.10(j) |
| PRO-04 | System documentation is controlled. | 11.10(k) |
| PRO-05 | The organization certifies to the FDA that its electronic signatures are the legally binding equivalent of handwritten ones. | 11.100(c) |
| PRO-06 | Passwords are not shared. Lost or compromised accounts are handled by a written procedure. | 11.300(b), (c) |
| PRO-07 | Audit trails and records are kept for at least as long as the underlying records must be kept. | 11.10(e) |