Truly independent web browser
#!/usr/bin/env bash
#
# Runs the accessibility-bridge regression tests. Uses the current session's AT-SPI2 bus + display by default.
# For CI, set CI=1 to spin up a private Xvfb + D-Bus session + AT-SPI2 bus first (see below).
#
# Requires: python3-gi, libatspi-2.0 client (usually installed as part of at-spi2-core).
# For Layer 2 Orca tests: the "orca" Python package must be importable (usually from at-spi2/orca distro package).
# For CI: xorg-x11-server-Xvfb, dbus, at-spi2-core with at-spi-bus-launcher.
#
# By default, runs both Layer 1 (tests/) and Layer 2 (tests_orca/) suites. To run only one or the other:
#
# ./run_tests.sh --layer=1
# ./run_tests.sh --layer=2
set -euo pipefail
SCRIPT_DIR="$(cd "$(dirname "${BASH_SOURCE[0]}")" && pwd)"
REPO_ROOT="$(cd "${SCRIPT_DIR}/../../.." && pwd)"
# The harness reads LADYBIRD_BINARY as the path to the Ladybird executable.
# Default to Build/release/bin/Ladybird for local runs.
# ctest sets this explicitly to $<TARGET_FILE:ladybird>.
: "${LADYBIRD_BINARY:=${REPO_ROOT}/Build/release/bin/Ladybird}"
export LADYBIRD_BINARY
if [[ ! -x "${LADYBIRD_BINARY}" ]]; then
echo "error: Ladybird binary not found at ${LADYBIRD_BINARY}" >&2
echo " build it with 'ninja -C Build/release ladybird'," >&2
echo " or set LADYBIRD_BINARY to the path of your Ladybird executable." >&2
exit 1
fi
# The harness uses PyGObject's gi module to talk to AT-SPI2. The Linux distro packages (python3-gi, gir1.2-atspi-2.0)
# install gi into the system /usr/bin/python3 — but the actions/setup-python interpreter used by GitHub Actions doesn't
# have it. So here, we pick whichever python3 on the system has gi: Honor a user-supplied PYTHON env var first — then
# probe a short list of candidates in order.
candidates=()
if [[ -n "${PYTHON:-}" ]]; then
candidates+=("${PYTHON}")
fi
candidates+=("python3" "/usr/bin/python3")
PYTHON_BIN=""
for cand in "${candidates[@]}"; do
if command -v "${cand}" >/dev/null 2>&1; then
if "${cand}" -c "import gi" 2>/dev/null; then
PYTHON_BIN="${cand}"
break
fi
fi
done
if [[ -z "${PYTHON_BIN}" ]]; then
echo "error: no python3 on PATH has the PyGObject (gi) module." >&2
echo " The harness uses gi to drive the AT-SPI2 surface." >&2
echo >&2
echo " Options:" >&2
echo " (1) Install the distro python3-gi package, which puts gi into /usr/bin/python3." >&2
echo " On Debian/Ubuntu: 'sudo apt install python3-gi gir1.2-atspi-2.0'." >&2
echo " On Fedora: 'sudo dnf install python3-gobject gir1.2-atspi-2.0'." >&2
echo " (2) Or set PYTHON to a python3 that has gi already." >&2
exit 1
fi
isolated=0
# Any non-empty/non-false value for CI triggers the isolated path. GH Actions sets CI=true; our ctest wrapper sets CI=1.
case "${CI:-}" in
""|0|false|False|FALSE) ;;
*) isolated=1 ;;
esac
layer=both
args=()
for arg in "$@"; do
case "$arg" in
--isolated) isolated=1 ;;
--layer=1) layer=1 ;;
--layer=2) layer=2 ;;
--layer=both) layer=both ;;
*) args+=("$arg") ;;
esac
done
# Build the discovery paths once.
discover_args=()
case "$layer" in
1) discover_args=(-s tests -t .) ;;
2) discover_args=(-s tests_orca -t .) ;;
both) discover_args=(-s . -t . -p 'test_*.py') ;;
esac
run_unittest() {
cd "${SCRIPT_DIR}"
exec "${PYTHON_BIN}" -m unittest discover "${discover_args[@]}" -v ${args[@]+"${args[@]}"}
}
if (( isolated == 0 )); then
run_unittest
fi
# NB: Isolated path: each run owns its display and the directory containing its AT-SPI2 socket.
: "${XVFB_SCREEN:=1280x1024x24}"
for tool in Xvfb dbus-run-session setsid; do
if ! command -v "${tool}" >/dev/null 2>&1; then
echo "error: isolated test run requires ${tool}, which is not on PATH." >&2
echo " install the relevant package (xvfb + dbus on Debian/Ubuntu;" >&2
echo " xorg-x11-server-Xvfb + dbus-daemon on Fedora), or run the" >&2
echo " tests without CI=1 to use the current session's display instead." >&2
exit 1
fi
done
# Ladybird binds its IPC sockets under XDG_RUNTIME_DIR (Core::StandardPaths::runtime_directory), and dbus-run-session
# binds its bus socket there too. A CI runner without a login session has no runtime directory, and parallel runs must
# not share one, so every run gets a private runtime directory. It lives directly under /tmp to keep socket paths
# within the sun_path limit.
XDG_RUNTIME_DIR="$(mktemp -d "/tmp/ladybird-a11y-XXXXXX")"
chmod 0700 "${XDG_RUNTIME_DIR}"
export XDG_RUNTIME_DIR
# Outer traps: stop what we started and remove the runtime directory, also when ctest stops a run that timed out.
XVFB_PID=""
DBUS_SESSION_PID=""
# shellcheck disable=SC2329 # Invoked by the EXIT trap below.
cleanup_outer() {
local rc=$?
if [[ -n "${DBUS_SESSION_PID}" ]]; then
kill -- "-${DBUS_SESSION_PID}" 2>/dev/null || true
fi
if [[ -n "${XVFB_PID}" ]]; then
kill "${XVFB_PID}" 2>/dev/null || true
fi
rm -rf "${XDG_RUNTIME_DIR}"
return "${rc}"
}
trap cleanup_outer EXIT
trap 'exit 143' TERM
trap 'exit 130' INT
# Let Xvfb pick a free display and report its number through -displayfd, so parallel runs never share a display.
xvfb_log="${XDG_RUNTIME_DIR}/xvfb.log"
xvfb_display_fifo="${XDG_RUNTIME_DIR}/display"
mkfifo "${xvfb_display_fifo}"
exec {xvfb_display_fd}<>"${xvfb_display_fifo}"
Xvfb -displayfd 3 -screen 0 "${XVFB_SCREEN}" -nolisten tcp 3>"${xvfb_display_fifo}" >"${xvfb_log}" 2>&1 &
XVFB_PID=$!
xvfb_display_number=""
xvfb_deadline=$((SECONDS + 30))
while ! read -r -t 1 xvfb_display_number <&"${xvfb_display_fd}"; do
if ! kill -0 "${XVFB_PID}" 2>/dev/null || (( SECONDS >= xvfb_deadline )); then
echo "error: Xvfb exited or failed to come up within 30s. Its log:" >&2
cat "${xvfb_log}" >&2 || true
exit 1
fi
done
exec {xvfb_display_fd}>&-
rm "${xvfb_display_fifo}"
export DISPLAY=":${xvfb_display_number}"
export QT_QPA_PLATFORM=xcb
# shellcheck disable=SC2016 # The single-quoted body is intentional — the
# inner bash -c expands its own $SCRIPT_DIR / $at_spi_bus_launcher etc.
setsid dbus-run-session -- bash -c '
set -euo pipefail
# Inner EXIT trap: SIGTERM the AT-SPI2 daemons we backgrounded. Without this, when python exits: (1) the daemons
# remain alive (orphaned to dbus-run-session), (2) nothing reaps them, and (3) the runner hangs until ctest hits its
# TIMEOUT — which in CI logs, we observed as ~600s of dead time per Layer.
AT_SPI_BUS_LAUNCHER_PID=""
AT_SPI2_REGISTRYD_PID=""
cleanup_inner() {
local rc=$?
for pid in "$AT_SPI2_REGISTRYD_PID" "$AT_SPI_BUS_LAUNCHER_PID"; do
[[ -n "$pid" ]] && kill "$pid" 2>/dev/null || true
done
return $rc
}
trap cleanup_inner EXIT
at_spi_bus_launcher=""
if command -v /usr/libexec/at-spi-bus-launcher >/dev/null 2>&1; then
at_spi_bus_launcher=/usr/libexec/at-spi-bus-launcher
elif command -v at-spi-bus-launcher >/dev/null 2>&1; then
at_spi_bus_launcher=$(command -v at-spi-bus-launcher)
fi
if [[ -n "$at_spi_bus_launcher" ]]; then
"$at_spi_bus_launcher" --launch-immediately &
AT_SPI_BUS_LAUNCHER_PID=$!
for _ in $(seq 1 50); do
if dbus-send --session --dest=org.freedesktop.DBus --print-reply=literal /org/freedesktop/DBus org.freedesktop.DBus.NameHasOwner string:org.a11y.Bus 2>/dev/null | grep -q "true"; then
break
fi
sleep 0.1
done
fi
if [[ -x /usr/libexec/at-spi2-registryd ]]; then
/usr/libexec/at-spi2-registryd &
AT_SPI2_REGISTRYD_PID=$!
fi
# Give the registry a moment to claim org.a11y.atspi.Registry on the a11y bus, then dump a one-shot diagnostic of
# the stack state. If a CI run later fails with "AT-SPI2 desktop children (0)", this snapshot is what tells us which
# piece is broken: at-spi-bus-launcher missing, registryd not running, a11y bus address unreachable, etc.
sleep 0.5
echo "=== AT-SPI2 stack diagnostic (one-shot) ==="
echo "DBUS_SESSION_BUS_ADDRESS=${DBUS_SESSION_BUS_ADDRESS:-<unset>}"
echo "DISPLAY=${DISPLAY:-<unset>}"
echo "XDG_RUNTIME_DIR=${XDG_RUNTIME_DIR:-<unset>}"
echo "--- relevant processes ---"
ps -eo pid,ppid,cmd | grep -Ei "(at-spi|atspi|dbus-daemon|dbus-launch|Xvfb)" | grep -v grep || echo " (none)"
echo "--- org.a11y.Bus.GetAddress on session bus ---"
if command -v gdbus >/dev/null 2>&1; then
gdbus call --session --dest=org.a11y.Bus --object-path=/org/a11y/bus --method=org.a11y.Bus.GetAddress 2>&1 || echo " gdbus call failed"
elif command -v dbus-send >/dev/null 2>&1; then
dbus-send --session --print-reply --dest=org.a11y.Bus /org/a11y/bus org.a11y.Bus.GetAddress 2>&1 || echo " dbus-send call failed"
else
echo " (no gdbus or dbus-send on PATH)"
fi
echo "--- org.a11y.atspi.Registry presence ---"
if command -v gdbus >/dev/null 2>&1; then
# Note: this asks the *session* bus whether it knows the registry name. The registry actually lives on the a11y
# bus (a separate D-Bus daemon). A session-bus false-result is expected; this is just a sanity print.
gdbus call --session --dest=org.freedesktop.DBus --object-path=/org/freedesktop/DBus --method=org.freedesktop.DBus.NameHasOwner org.a11y.atspi.Registry 2>&1 || echo " gdbus name-has-owner failed"
fi
echo "=== end diagnostic ==="
cd "'"${SCRIPT_DIR}"'"
# Run python (no exec) so the EXIT trap above fires after unittest finishes and reaps the AT-SPI2 daemons.
'"${PYTHON_BIN}"' -m unittest discover '"${discover_args[*]}"' -v "$@"
' -- ${args[@]+"${args[@]}"} &
# NB: The session runs in the background in its own process group, and we wait for it. The TERM and INT traps then run
# while it is running and can stop the whole group, including the tests and the browsers they started.
DBUS_SESSION_PID=$!
rc=0
wait "${DBUS_SESSION_PID}" || rc=$?
DBUS_SESSION_PID=""
exit "${rc}"