OpenVINO™ is an open source toolkit for optimizing and deploying AI inference
C++ aicomputer-visiondeep-learningdeploy-aidiffusion-modelsgenerative-aigood-first-issueinferencellm-inferencenatural-language-processingnlpopenvinooptimize-aiperformance-boostrecommendation-systemspeech-recognitionstable-diffusiontransformersyolo
4-bit Weight Quantization
=========================
The 4-bit weight quantization method results in significant reduction in model size and
memory usage, making LLMs more accessible to less performant devices.
It also usually offers lower inference latency, however, depending on specific models,
it may potentially impact the accuracy.
Nevertheless, the INT4 method has several parameters that can provide different performance-accuracy
trade-offs after optimization:
* ``mode`` - there are two optimization modes: symmetric and asymmetric.
.. tab-set::
.. tab-item:: Symmetric Compression
:sync: int4-sym
INT4 Symmetric mode (``INT4_SYM``) involves quantizing weights to a signed 4-bit integer
symmetrically without zero point. This mode is faster than the INT8_ASYM, making
it ideal for situations where **speed and size reduction are prioritized over accuracy**.
.. code-block:: python
from nncf import compress_weights
from nncf import CompressWeightsMode
compressed_model = compress_weights(model, mode=CompressWeightsMode.INT4_SYM)
.. tab-item:: Asymmetric Compression
:sync: int4-asym
INT4 Asymmetric mode (``INT4_ASYM``) also uses an unsigned 4-bit integer but quantizes weights
asymmetrically with a non-fixed zero point. This mode slightly compromises speed in
favor of better accuracy compared to the symmetric mode. This mode is useful when
**minimal accuracy loss is crucial**, but a faster performance than INT8 is still desired.
.. code-block:: python
from nncf import compress_weights
from nncf import CompressWeightsMode
compressed_model = compress_weights(model, mode=CompressWeightsMode.INT4_ASYM)
* ``group_size`` controls the size of the group of weights that share the same
quantization parameters. Shared quantization parameters help to speed up the
calculation of activation values as they are dequantized and quantized between
layers. However, they can reduce accuracy. The following group sizes are
recommended: ``128``, ``64``, ``32`` (``128`` is default value).
`Smaller Group Size`: Leads to a more accurate model but increases the model's
footprint and reduces inference speed.
`Larger Group Size`: Results in faster inference and a smaller model, but might
compromise accuracy.
* ``ratio`` controls the ratio between the layers compressed to the precision defined
by ``mode`` and the rest of the layers that will be kept in the ``backup_mode`` in the optimized model.
Ratio is a decimal between 0 and 1. For example, 0.8 means that 80% of layers will be
compressed to the precision defined by ``mode``, while the rest will be compressed to
``backup_mode`` precision. The default value for ratio is 1.
| **Higher Ratio (more layers set to mode precision)**:
| Reduces the model size and increase inference speed but
might lead to higher accuracy degradation.
| **Lower Ratio (more layers set to backup_mode precision)**:
| Maintains better accuracy but results in a larger model size
and potentially slower inference.
In the example below, 90% of the model's layers are quantized to INT4 asymmetrically with
a group size of 64:
.. code-block:: python
from nncf import compress_weights, CompressWeightsMode
# Example: Compressing weights with INT4_ASYM mode, group size of 64, and 90% INT4 ratio
compressed_model = compress_weights(
model,
mode=CompressWeightsMode.INT4_ASYM,
group_size=64,
ratio=0.9,
)
* ``scale_estimation`` - a boolean parameter that enables more accurate estimation of
quantization scales. Especially helpful when the weights of all layers are quantized to
4 bits. Requires dataset.
* ``awq`` - a boolean parameter that enables the AWQ method for more accurate INT4 weight
quantization. Especially helpful when the weights of all the layers are quantized to
4 bits. The method can sometimes result in reduced accuracy when used with
Dynamic Quantization of activations. Requires dataset.
* ``gptq`` - a boolean parameter that enables the GPTQ method for more accurate INT4 weight
quantization. Requires dataset.
* ``dataset`` - a calibration dataset for data-aware weight compression. It is required
for some compression options, for example, ``scale_estimation``, ``gptq`` or ``awq``. Some types
of ``sensitivity_metric`` can use data for precision selection.
* ``sensitivity_metric`` - controls the metric to estimate the sensitivity of compressing
layers in the bit-width selection algorithm. Some of the metrics require dataset to be
provided. The following types are supported:
* ``nncf.SensitivityMetric.WEIGHT_QUANTIZATION_ERROR`` - a data-free metric computed as
the inverted 8-bit quantization noise. Weights with highest value of this metric can
be accurately quantized channel-wise to 8-bit. The idea is to leave these weights in
8 bit, and quantize the rest of layers to 4-bit group-wise. Since group-wise is more
accurate than per-channel, accuracy should not degrade.
* ``nncf.SensitivityMetric.HESSIAN_INPUT_ACTIVATION`` - requires a dataset. The average
Hessian trace of weights with respect to the layer-wise quantization error multiplied
by L2 norm of 8-bit quantization noise.
* ``nncf.SensitivityMetric.MEAN_ACTIVATION_VARIANCE`` - requires a dataset. The mean
variance of the layers' inputs multiplied by inverted 8-bit quantization noise.
* ``nncf.SensitivityMetric.MAX_ACTIVATION_VARIANCE`` - requires a dataset. The maximum
variance of the layers' inputs multiplied by inverted 8-bit quantization noise.
* ``nncf.SensitivityMetric.MEAN_ACTIVATION_MAGNITUDE`` - requires a dataset. The mean
magnitude of the layers' inputs multiplied by inverted 8-bit quantization noise.
* ``all_layers`` - a boolean parameter that enables INT4 weight quantization of all
Fully-Connected and Embedding layers, including the first and last layers in the model.
* ``lora_correction`` - a boolean parameter that enables the LoRA Correction Algorithm
to further improve the accuracy of INT4 compressed models on top of other
algorithms - AWQ and Scale Estimation.
* ``backup_mode`` - defines a backup precision for mixed-precision weight compression.
There are three modes: INT8_ASYM, INT8_SYM, and NONE, which retains
the original floating-point precision of the model weights (``INT8_ASYM`` is default value).
.. tip::
NNCF enables you to stack the supported optimization methods. For example, AWQ,
Scale Estimation and GPTQ methods may be enabled all together to achieve better accuracy.
4-bit Weight Quantization with GPTQ
###################################
You can use models from Hugging Face
`Transformers <https://github.com/huggingface/transformers>`__ library, which are quantized
with `GPTQ <https://github.com/PanQiWei/AutoGPTQ>`__ algorithm. Such models do not require
additional optimization step because the conversion will automatically preserve
the INT4 optimization results, and model inference will eventually benefit from it.
See the `example of a model <https://huggingface.co/TheBloke/Llama-2-7B-Chat-GPTQ>`__
that has been optimized with GPTQ.
You can also refer to the code sample below which shows how to load a 4-bit
GPTQ model and run inference.
.. dropdown:: Using a GPTQ model.
Make sure to install GPTQ dependencies by running the following command:
.. code-block:: python
pip install optimum[openvino] auto-gptq
.. code-block:: python
from optimum.intel.openvino import OVModelForCausalLM
from transformers import AutoTokenizer, pipeline
# Load model from Hugging Face already optimized with GPTQ
model_id = "TheBloke/Llama-2-7B-Chat-GPTQ"
model = OVModelForCausalLM.from_pretrained(model_id, export=True)
# Inference
tokenizer = AutoTokenizer.from_pretrained(model_id)
pipe = pipeline("text-generation", model=model, tokenizer=tokenizer)
phrase = "The weather is"
results = pipe(phrase)
print(results)