OpenVINO™ is an open source toolkit for optimizing and deploying AI inference
C++ aicomputer-visiondeep-learningdeploy-aidiffusion-modelsgenerative-aigood-first-issueinferencellm-inferencenatural-language-processingnlpopenvinooptimize-aiperformance-boostrecommendation-systemspeech-recognitionstable-diffusiontransformersyolo
E2e accuracy improvement (#31678)
Mingyu Kimc16e0d63743b
diff --git a/tests/llm/accuracy_conformance.py b/tests/llm/accuracy_conformance.pyindex 2a3dd0a6755..ed453202dfa 100644--- a/tests/llm/accuracy_conformance.py+++ b/tests/llm/accuracy_conformance.py@@ -7,34 +7,88 @@ import tempfileimport pytestfrom optimum.intel.openvino import (OVModelForCausalLM,OVWeightQuantizationConfig)-import whowhatbench as wwbfrom transformers import AutoModelForCausalLM, AutoTokenizer, set_seed+import whowhatbench as wwb+from whowhatbench.wwb import genai_gen_text+from whowhatbench.model_loaders import load_model+from openvino_tokenizers import convert_tokenizer+from openvino import save_modellogging.basicConfig(level=logging.INFO)logger = logging.getLogger(__name__)-MODEL_IDS = [- "TinyLlama/TinyLlama-1.1B-Chat-v1.0",- "Qwen/Qwen2-0.5B-Instruct",-]-DEVICES = [- "CPU",- "GPU",-]-NUMBER_OF_SAMPLES = 15-METRIC_OF_INTEREST = "similarity"--REFERENCES = {- "llama": {"INT8": 0.95, "INT4": 0.95},- "qwen2": {"INT8": 0.86, "INT4": 0.82},-}-ACCURACY_THRESHOLDS = {- "INT8": 0.05,- "INT4": 0.05,+# Test Configuration Catalog+TEST_CATALOG = {+ "TinyLlama/TinyLlama-1.1B-Chat-v1.0": {+ "GPU": {+ "INT8": {"reference": 0.98, "threshold": 0.03},+ "INT4": {"reference": 0.71, "threshold": 0.03},+ },+ "CPU": {+ "INT8": {"reference": 0.94, "threshold": 0.03},+ "INT4": {"reference": 0.77, "threshold": 0.03},+ },+ },+ "Qwen/Qwen2-0.5B-Instruct": {+ "GPU": {+ "INT8": {"reference": 0.86, "threshold": 0.03},+ "INT4": {"reference": 0.72, "threshold": 0.03},+ },+ "CPU": {+ "INT8": {"reference": 0.82, "threshold": 0.03},+ "INT4": {"reference": 0.68, "threshold": 0.03},+ },+ },}-tmp_dir = tempfile.mkdtemp(dir=os.getcwd())-logger.info(f"Created temporary directory: {tmp_dir}")+# Extract configuration from catalog+MODEL_IDS = list(TEST_CATALOG.keys())+DEVICES = list(set(device for model_config in TEST_CATALOG.values()+ for device in model_config.keys()))++NUMBER_OF_SAMPLES = 15+METRIC_OF_INTEREST = "similarity"+PREC_INT8 = "INT8"+PREC_INT4 = "INT4"+GPU_SUFFIX = 0 # Suffix to append to device name (e.g., '.1' for GPU.1). To be replaced by option+DO_NOT_CLEANUP = False++def get_reference(model_id, device, precision):+ """Get reference value from catalog"""+ return TEST_CATALOG[model_id][device][precision]["reference"]++def get_threshold(model_id, device, precision):+ """Get threshold value from catalog"""+ return TEST_CATALOG[model_id][device][precision]["threshold"]++def get_tmp_dir():+ """Get temporary directory based on cleanup preference"""+ # Check environment variable set by pytest option+ do_not_cleanup = DO_NOT_CLEANUP++ if do_not_cleanup:+ # Use fixed directory by default (could use tempfile.mkdtemp for true temporary)+ tmp_dir = os.path.join(os.getcwd(), "test_models_cache")+ os.makedirs(tmp_dir, exist_ok=True)+ else:+ # Use temp directory when cleanup is disabled+ tmp_dir = tempfile.mkdtemp(dir=os.getcwd())+ logger.info(f"Using directory: {tmp_dir}")+ return tmp_dir++tmp_dir = get_tmp_dir()++def get_model_path(model_id, prec):+ """+ Returns the path to the model based on its id and precision.+ """+ return os.path.join(tmp_dir, f"{model_id.replace('/', '_')}_{prec}")++def get_gt_path(model_id, use_chat_template):+ """+ Returns the path to the ground truth data based on the model name.+ """+ return os.path.join(tmp_dir, f"{model_id.replace('/', '_')}_gt_{NUMBER_OF_SAMPLES}_{'chat_template' if use_chat_template else 'no-chat-template'}.json")def init_test_scope():test_scope = []@@ -43,75 +97,107 @@ def init_test_scope():logger.info(f"Downloading and quantizing model: {model_id}")model = AutoModelForCausalLM.from_pretrained(model_id)tokenizer = AutoTokenizer.from_pretrained(model_id)- model_type = model.config.model_type- model_path = os.path.join(tmp_dir, model_type)+ model_path = get_model_path(model_id, "org")model.save_pretrained(model_path)tokenizer.save_pretrained(model_path)-- ov_model = OVModelForCausalLM.from_pretrained(model_path, load_in_8bit=True)- ov_model_path = os.path.join(tmp_dir, model_type + "_ov")- ov_model.save_pretrained(ov_model_path)- tokenizer.save_pretrained(ov_model_path)- del ov_model+ ov_tokenizer, ov_detokenizer = convert_tokenizer(tokenizer, with_detokenizer=True)++ int8_model_path = get_model_path(model_id, PREC_INT8)+ # If directory exists, do not quantize again. It is for local development purpose. CI should re-generate it everytime.+ if not os.path.exists(int8_model_path):+ logger.info(f'Saving int8 OpenVINO model: {int8_model_path}')+ ov_model = OVModelForCausalLM.from_pretrained(model_path, load_in_8bit=True)+ ov_model.save_pretrained(int8_model_path)+ tokenizer.save_pretrained(int8_model_path)+ del ov_model+ save_model(ov_tokenizer, os.path.join(int8_model_path, "openvino_tokenizer.xml"))+ save_model(ov_detokenizer, os.path.join(int8_model_path, "openvino_detokenizer.xml"))gc.collect()- quantization_config = OVWeightQuantizationConfig(bits=4, ratio=0.5)- quantized_model = OVModelForCausalLM.from_pretrained(- model_path, quantization_config=quantization_config- )- quantized_model_path = os.path.join(tmp_dir, model_type + "_ov_int4")- quantized_model.save_pretrained(quantized_model_path)- tokenizer.save_pretrained(quantized_model_path)- del quantized_model+ int4_model_path = get_model_path(model_id, PREC_INT4)+ if not os.path.exists(int4_model_path):+ logger.info(f'Quantizing model to INT4: {int4_model_path}')+ quantization_config = OVWeightQuantizationConfig(bits=4, ratio=0.8)+ quantized_model = OVModelForCausalLM.from_pretrained(+ model_path, quantization_config=quantization_config+ )+ quantized_model.save_pretrained(int4_model_path)+ tokenizer.save_pretrained(int4_model_path)+ del quantized_model+ save_model(ov_tokenizer, os.path.join(int4_model_path, "openvino_tokenizer.xml"))+ save_model(ov_detokenizer, os.path.join(int4_model_path, "openvino_detokenizer.xml"))gc.collect()set_seed(42)- evaluator = wwb.Evaluator(- base_model=model, tokenizer=tokenizer, num_samples=NUMBER_OF_SAMPLES- )- gt_path = os.path.join(tmp_dir, model_type + "_gt.json")- evaluator.dump_gt(gt_path)- [- test_scope.append((ov_model_path, model_type, "INT8", gt_path, device))- for device in DEVICES- ]- [- test_scope.append((ov_model_path, model_type, "INT4", gt_path, device))- for device in DEVICES- ]+ use_chat_template = False # (tokenizer is not None and tokenizer.chat_template is not None)+ gt_path = get_gt_path(model_id, use_chat_template)+ if not os.path.exists(gt_path):+ evaluator = wwb.Evaluator(base_model=model, tokenizer=tokenizer, num_samples=NUMBER_OF_SAMPLES, use_chat_template=use_chat_template)+ logger.info(f'{gt_path} does not exist, creating ground truth data...')+ evaluator.dump_gt(gt_path)++ # Generate test cases for all device/precision combinations in catalog+ for device in TEST_CATALOG[model_id].keys():+ for precision in TEST_CATALOG[model_id][device].keys():+ test_scope.append((model_id, precision, device))return test_scopedef teardown_module():- logger.info(f"Deleting temporary directory: {tmp_dir}")- shutil.rmtree(tmp_dir)+ """Clean up temporary directory based on cleanup option"""+ do_not_cleanup = DO_NOT_CLEANUP # to be replaced by pytest option+ if do_not_cleanup:+ logger.info(f"Cleanup disabled - preserving directory: {tmp_dir}")+ else:+ logger.info(f"Deleting temporary directory: {tmp_dir}")+ shutil.rmtree(tmp_dir)-test_scope = init_test_scope()+test_scope = init_test_scope()@pytest.mark.parametrize(- ("model_path", "model_type", "precision", "gt_data", "device"),+ ("model_id", "precision", "device"),test_scope,)-def test_accuracy_conformance(model_path, model_type, precision, gt_data, device):- if device == "GPU":- pytest.skip("CVS-171598")+def test_accuracy_conformance(model_id, precision, device):+ # os.environ["OV_GPU_DYNAMIC_QUANTIZATION_THRESHOLD"] = "1"++ task = 'text'+ ov_config = None+ hf = None+ use_genai = True+ dont_use_llamacpp = False+ model_path = get_model_path(model_id, precision)+ actual_device = f'{device}.{GPU_SUFFIX}' if GPU_SUFFIX and device == "GPU" else device+ print(f"Testing model: {model_path}, precision: {precision}, device: {actual_device}")+ target_model = load_model(task, model_path, actual_device, ov_config, hf, use_genai, dont_use_llamacpp)- target_model = OVModelForCausalLM.from_pretrained(model_path, device=device, ov_config={"KV_CACHE_PRECISION": "f16"})tokenizer = AutoTokenizer.from_pretrained(model_path)+ use_chat_template = False #(tokenizer is not None and tokenizer.chat_template is not None)+ gt_data = get_gt_path(model_id, use_chat_template)+evaluator = wwb.Evaluator(base_model=None,- tokenizer=tokenizer,gt_data=gt_data,+ tokenizer=tokenizer,+ similarity_model_id='sentence-transformers/all-mpnet-base-v2',num_samples=NUMBER_OF_SAMPLES,+ gen_answer_fn=genai_gen_text,+ use_chat_template=use_chat_template,)set_seed(42)- _, all_metrics = evaluator.score(target_model)+ _, all_metrics = evaluator.score(target_model, evaluator.get_generation_fn())metric = all_metrics[METRIC_OF_INTEREST].values[0]- abs_metric_diff = abs(REFERENCES[model_type][precision] - metric)- print(metric, REFERENCES[model_type][precision], model_type, precision)- assert abs_metric_diff <= ACCURACY_THRESHOLDS[precision]+ evaluator.dump_predictions(os.path.join(tmp_dir, f"{get_model_path(model_id, precision)}_{actual_device}_target.csv"))++ # Get expected values from catalog (use original device for lookup)+ expected_reference = get_reference(model_id, device, precision)+ threshold = get_threshold(model_id, device, precision)++ abs_metric_diff = abs(expected_reference - metric)+ print(f"Metric: {metric}, Expected: {expected_reference}, Model: {model_id}, Precision: {precision}")+ assert abs_metric_diff <= threshold, f"Metric difference {abs_metric_diff} exceeds threshold {threshold}"