Official Codebase of 3DCodeVerse
Reading a contract fix hint and turning it into one edit
Every example below is a real fix_hint string from bench/out (mined 2026-08-25). The
gate writes the numbers in the language's authoring frame, so they can be used directly.
1. One axis short — the common case
part 'FacetedRoofCap' bbox deviates from the plan (worst 2.2x tolerance)
part 'FacetedRoofCap': size 262.0x79.2x55.1 vs planned 262.0x88.0x54.0 cm
(D x-0.0cm, y-8.8cm, z+1.1cm); planned centre (0.000, -0.060, 2.880) m
Read it as: two axes are fine, the depth is 8.8 cm short on a planned 88 cm — a clean 10 %, which is exactly the relative tolerance, so it tipped over at 2.2x. The cap was almost certainly built from a profile whose depth constant was the inner span while the plan meant the outer one, or a bevel ate the overhang. The edit is one constant, not a rebuild.
Anti-pattern: scaling the whole object by 88/79.2 to "fix the number". That trades one finding for a wrong overall bbox and a broken contact graph.
2. Centre only — the part is the right size, in the wrong place
part 'FrontApron': centre off by (x+0.0cm, y-3.0cm, z-0.0cm);
planned centre (0.000, -0.200, 0.402) m
No size clause at all, so the geometry is correct and only the placement is wrong. Move the part by the negation of the delta. Do not touch its dimensions.
3. Both — a part that grew from one end
part 'LeftBraceLower': size 18.1x2.3x15.7 vs planned 22.0x3.0x20.0 cm
(D x-3.9cm, y-0.7cm, z-4.3cm); centre off by (x+2.2cm, y+0.4cm, z-0.6cm)
A size delta with roughly half of it echoed in the centre means the part was built from a fixed origin and stopped short: one end stayed put, the other never reached. Fix the length constant and the centre follows; correcting the centre alone leaves the size wrong.
4. Instances
'FrontLeg' (each instance): size 6.5x7.0x30.1 vs planned 3.5x7.0x28.0 cm
(D x+3.0cm, y-0.0cm, z+2.1cm)
(each instance) means the gate compared the plan box with the size of ONE copy — here a
3.5 cm leg came out 6.5 cm, most likely a radius used where a diameter was planned. The
other wording, (all instances), means it compared the plan box with the union of every
copy. The gate picks whichever reading is closer to the plan, so you never have to guess
which one the planner meant: build one copy at the planned size and the per-instance
reading passes; build a set whose union matches and the union reading passes.
5. Footprint and ground
translate everything by (-0.019, +0.006, +0.000) m to centre the footprint
object floats 130.0 mm above the ground
Both hints hand you the vector. Apply the same vector to every part — three.js: the root
Group; cadquery: each child's loc; blender: every top-level object (there is no container,
a parent Empty would merge the parts) — so the parts keep their places relative to each
other and the contact graph does not change.
Order of work on a repair round
3dcode check-contract, and sort the findings by the "worst Nx tolerance" number in the message.- Fix ERRORs (ratio above 3x) first; they are the only ones that fail the gate.
- Where a constant drives the dimension, changing the constant fixes every place that uses it.
3dcode build->3dcode check-contractagain. A fix that moves a second part into failure means the two shared a derived number and one of them was re-typed.