Agent skill for creative 3D visualization: turn an idea into a Three.js/Blender scene worth exploring. Claude Code + Codex plugin, 223 recipes, 440 knowledge records, 22 proved kits, 37 runnable studies.
{
"schema_version": 1,
"id": "recipe.cardiac-cycle-valves",
"revision": 1,
"status": "active",
"record_kind": "factual",
"title": {
"en": "Cardiac cycle phases and valve states"
},
"aliases": {
"en": [
"cardiac cycle",
"heart valves",
"systole and diastole"
]
},
"direction_ids": [
"physiology-biomechanics"
],
"summary": "Drive valve states from an explicit phase model so opening and closing follow declared pressure comparisons rather than animation timing.",
"objective": "Build a cardiac cycle explorer where stepping through phases opens and closes the atrioventricular and semilunar valves for stated reasons.",
"tags": [
"cardiac cycle",
"valves",
"phases"
],
"subject_terms": [
"systole",
"diastole",
"atrioventricular valve",
"semilunar valve",
"ventricular filling",
"ventricular ejection",
"isovolumetric",
"cardiac phase"
],
"intent_signals": [
"Show what opens and closes each heart valve during a beat.",
"Step through the cardiac cycle instead of watching a loop."
],
"example_prompts": [
"Build a cardiac cycle explorer with phase stepping and valve states I can inspect.",
"Show systole and diastole with the reason each valve opens or closes."
],
"negative_signals": [
"Not an electrophysiology, pressure-volume or haemodynamic solver.",
"Not an ECG interpretation aid and not usable for any clinical judgement."
],
"not_for": [
"Not an electrophysiology, pressure-volume or haemodynamic solver.",
"Not an ECG interpretation aid and not usable for any clinical judgement."
],
"entities": [
{
"name": "Chamber shells",
"guidance": "Reuse a sectioned four-chamber shell whose cavities are separate volumes, so a phase can change cavity volume without merging chambers."
},
{
"name": "Valve leaflets",
"guidance": "Model each valve as discrete leaflets with a hinge ring and a closed-state seal, so an open and a closed valve differ in geometry rather than in opacity."
},
{
"name": "Phase panel",
"guidance": "Show the current phase name, the qualitative pressure comparison driving it, and the resulting state of each of the four valves as text as well as geometry."
}
],
"state_contract": {
"model": "Ordered phase list; each phase declares a qualitative pressure comparison between chamber, atrium and outflow vessel and the resulting open or closed state of each valve. Volumes are authored per phase, not integrated.",
"authority": "The phase index is authoritative. Leaflet pose, chamber volume and arrows are derived from the phase record; scrubbing backwards must restore the earlier valve states exactly.",
"actions": [
"Step to the next or previous phase.",
"Hold a phase and inspect the stated pressure comparison.",
"Toggle flow arrows and the section plane.",
"Reset to the start of ventricular filling."
]
},
"invariants": [
"Each valve has exactly one declared state within a phase; the pressure comparison recorded for the next phase decides whether that state changes, so a valve may legitimately remain open, or remain closed, across adjacent compatible phases.",
"Anatomical left and right stay labelled independently of screen position.",
"Transvalvular flow arrows only appear where the phase record has an open valve.",
"Isovolumic phases are represented with all four valves closed; a phase record that leaves every valve closed is a valid state, not a missing entry."
],
"motion_guidance": [
"Interpolate leaflet pose between phase states for legibility, but let the discrete phase remain the state of record.",
"Do not free-run the cycle as evidence of timing; if a play control exists, its rate is a display choice."
],
"known_limits": [
"Qualitative phase ordering only; no pressures in mmHg, no volumes in millilitres and no durations are asserted.",
"Chamber and valve geometry remain authored approximations that need expert review before teaching use.",
"Authored guidance only: no scene runtime, rendering or numerical calibration has been run for this recipe."
],
"claims": [
{
"id": "claim.rd-systole-diastole",
"statement": "Systole is the period of contraction during which the heart pumps blood into circulation, and diastole is the period of relaxation during which the chambers fill.",
"scope": "Definitions of the two named periods; no timing values are claimed.",
"source_refs": [
{
"source_id": "source.recipe-depth-openstax-cardiac-cycle",
"locator": "19.3, definitions of systole and diastole"
}
]
},
{
"id": "claim.rd-valve-states",
"statement": "Rising ventricular pressure closes the tricuspid and mitral valves, ventricular ejection pushes the pulmonary and aortic semilunar valves open, and those semilunar valves close when ventricular pressure falls below the pressure in the pulmonary trunk and aorta.",
"scope": "Qualitative pressure-driven ordering of valve states within one cycle.",
"source_refs": [
{
"source_id": "source.recipe-depth-openstax-cardiac-cycle",
"locator": "19.3, atrioventricular and semilunar valve behaviour"
}
]
}
],
"object_craft": [
{
"family": "Chamber shells",
"structure": "Sectioned cavities with wall thickness that differs between atria and ventricles; keep the cut capped so the interior reads as a solid organ.",
"material": "Restrained tissue palette in which cavity, wall and cut cap differ by roughness and value; colour marks chambers, not oxygen content.",
"articulation": "Volume change per phase is an authored blend between stored shapes, not a deformation solver."
},
{
"family": "Valve leaflets",
"structure": "Thin leaflets with a visible free edge and a hinge ring; closed state must show contacting edges rather than interpenetrating sheets.",
"material": "Slightly translucent, low-roughness leaflet material distinct from the chamber wall so open and closed states are readable in section.",
"articulation": "Leaflets rotate about their hinge ring between the two states declared by the phase record."
}
],
"physical_contract": {
"model": "display-transform",
"scope": "Phase-indexed presentation of authored geometry; no pressure solver, no fluid and no contact.",
"state": [
"phase index",
"valve states",
"section plane"
],
"checks": [
"Stepping forward then backward restores the previous valve states.",
"Every transvalvular flow arrow shown corresponds to an open valve in the current phase record."
]
},
"related_ids": [
"recipe.heart-cutaway",
"knowledge.state-playback",
"knowledge.signed-field-section"
]
}