A failed re-hold sweep is recorded instead of escaping the process

  • Date: 2026-11-10
  • Type: fix
  • Scope: server
  • Breaking: no

中文版

The timer that re-holds dropped machine connections once a minute called void autoConnect(), and nothing took the rejection. A timer callback has no caller to throw to: any failure of that sweep — an ssh config that cannot be read, a database closed underneath it — came out as an unhandled rejection once a minute for as long as the App lived, visible only in the process log.

The tick now goes through a small private step that awaits the sweep and reports a failure to the error centre, under the same source and code the boot path already uses for the same fault (process / machines_reconnect_failed): one machine that will not come back is one class in the panel, and one ignore rule there silences both the boot attempt and the retries.

A stop() that arrives while the sweep is still reaching out is not reported: the closed database is the retirement itself, not a fault, so a retired generation says nothing about its own shutdown.

Verification

test/machines-lifecycle.test.ts gains two cases: a failing tick is recorded and nothing escapes the process (a unhandledRejection listener observes the escape and sees none), and a stop() landing mid-sweep records nothing.