Open-source AI Security Operations Center: alert fusion, LLM-agent triage, MITRE ATT&CK investigation, and a replayable decision ledger for every agent step. Self-hostable, runs with no API keys, MIT licensed. Ships an MCP server for Claude, Cursor and Continue.
Python agentic-aiai-securityalert-triageblue-teamcybersecuritydetection-engineeringincident-responselanggraphllm-agentsmcpmitre-attackmodel-context-protocolpurple-teamsecurity-operationsself-hostedsiemsoarsocthreat-detectionthreat-intelligence
package syslog
import (
"context"
"fmt"
"time"
"github.com/beenuar/aisoc/services/ingest/internal/inbox"
"github.com/beenuar/aisoc/services/ingest/internal/normalizer"
"github.com/google/uuid"
)
// TokenResolver is the half of inbox.Store this package needs. Narrowed to
// one method so a test can supply one without a Postgres pool.
type TokenResolver interface {
Resolve(ctx context.Context, token string) (*inbox.Token, error)
}
// Publisher is the half of publisher.Publisher this package needs.
type Publisher interface {
PublishBatch(ctx context.Context, events []*normalizer.NormalizedEvent) error
}
// TemplateSource resolves a template id to a template.
type TemplateSource interface {
Get(id string) (*inbox.Template, error)
}
// RequiredTemplateID is the template a syslog token must be minted with.
//
// One token covers all four formats deliberately. A single appliance
// commonly emits RFC 3164 for its own daemons and CEF for its security
// events, and making the operator mint two tokens and run two ports for one
// device would be a configuration no vendor's documentation describes.
const RequiredTemplateID = "syslog"
// : Which OCSF template each parsed format is projected through. CEF and
// : LEEF carry vendor, product and severity of their own, so projecting them
// : through the plain syslog template would throw that away and file an
// : ArcSight finding as an anonymous log line.
var templateForFormat = map[Format]string{
FormatRFC5424: "syslog",
FormatRFC3164: "syslog",
FormatUnstructured: "syslog",
FormatCEF: "cef-syslog",
FormatLEEF: "leef-syslog",
}
// PublishingSink turns parsed messages into OCSF events on Kafka.
//
// The tenant comes from the configured token and from nowhere else. That is
// the whole reason this is a token and not a field: syslog has no
// authenticated principal and no header, so anything taken off the wire is
// caller-controlled, and a tenant a sender can set is a cross-tenant write
// waiting for someone to notice. One listener therefore serves one tenant,
// and a multi-tenant deployment runs one port per tenant — stated in the
// setup guide rather than left to be discovered.
type PublishingSink struct {
tokens TokenResolver
templates TemplateSource
pub Publisher
token string
}
// NewPublishingSink wires the sink. The token is not resolved here: a
// resolver needs a context and a database, and failing construction because
// Postgres was slow to start would take the whole ingest service down with
// it. It is resolved on the first delivery instead, where a failure is a
// counted, named error.
func NewPublishingSink(tokens TokenResolver, templates TemplateSource, pub Publisher, token string) (*PublishingSink, error) {
if tokens == nil || templates == nil || pub == nil {
return nil, fmt.Errorf("syslog: sink needs a token resolver, a template source and a publisher")
}
if token == "" {
return nil, fmt.Errorf("syslog: no ingest token configured, so there is no tenant to attribute messages to")
}
return &PublishingSink{tokens: tokens, templates: templates, pub: pub, token: token}, nil
}
// Deliver projects a batch and publishes it.
func (s *PublishingSink) Deliver(ctx context.Context, messages []*Message) error {
if len(messages) == 0 {
return nil
}
tok, err := s.tokens.Resolve(ctx, s.token)
if err != nil {
// Named rather than generic: a revoked token and an unreachable
// database are different problems and only one of them is fixed by
// waiting.
return fmt.Errorf("syslog: resolving the configured ingest token: %w", err)
}
if tok.TemplateID != RequiredTemplateID {
return fmt.Errorf(
"syslog: the configured token was minted with template %q; the listener needs one minted with %q",
tok.TemplateID, RequiredTemplateID,
)
}
receivedAt := time.Now().UTC().Format(time.RFC3339Nano)
tenantID := tok.TenantID.String()
events := make([]*normalizer.NormalizedEvent, 0, len(messages))
for _, msg := range messages {
templateID := templateForFormat[msg.Format]
if templateID == "" {
templateID = RequiredTemplateID
}
tmpl, err := s.templates.Get(templateID)
if err != nil {
// Falling back to the plain template would file a CEF finding
// as an anonymous log line, which is worse than refusing: the
// record would look complete.
return fmt.Errorf("syslog: this build has no %q template, so %s messages cannot be normalised", templateID, msg.Format)
}
connectorRef := "syslog:" + templateID
ocsf := tmpl.Apply(msg.Fields(), tenantID, connectorRef, receivedAt)
events = append(events, &normalizer.NormalizedEvent{
ID: uuid.NewString(),
ConnectorID: connectorRef,
TenantID: tenantID,
OcsfEvent: ocsf,
NormalizationVersion: "syslog/1.0",
})
}
return s.pub.PublishBatch(ctx, events)
}