ci(verify): retry a lost GPU device once under proven starvation

Richie McIlroy37d01581be1a
diff --git a/crates/verify/README.md b/crates/verify/README.md
index 9551eec66..9e9d0a005 100644
--- a/crates/verify/README.md
+++ b/crates/verify/README.md
@@ -132,8 +132,8 @@ blessed failure is a bug that the suite keeps checking.
A wake gap of 100 ms or more proves the runner stopped scheduling the
process. Only wall-clock failures are excused by it: a real-time playback
case that delivered too few frames becomes `inconclusive`, and a test
- killed at its timeout or by wgpu's 6.3 s queue drain is retryable when its
- sentinel log shows the gap. `scripts/verify/retry.py` reruns those tests
+ killed at its timeout, by wgpu's 6.3 s queue drain or by a lost GPU device is
+ retryable when its sentinel log shows the gap. `scripts/verify/retry.py` reruns those tests
once with `CAP_VERIFY_RETRY=1`; a case that is inconclusive again fails as
`environment`, and the job passes only if every failure was retryable and
every retry passed. Content, frame identity, timestamps and sync never
diff --git a/scripts/verify/retry.py b/scripts/verify/retry.py
index a8018d4a0..918df6c77 100644
--- a/scripts/verify/retry.py
+++ b/scripts/verify/retry.py
@@ -10,8 +10,9 @@ is one that wall-clock timing can cause:
judged in cap_verify::report::settle), or
- nextest killed it at its timeout and its sentinel log shows such a gap, or
- it panicked in wgpu-core's queue drop ("We timed out while waiting on the
- last successful submission", a 6.3 s limit) and its sentinel log shows
- such a gap.
+ last successful submission", a 6.3 s limit) or on a lost GPU device
+ ("Device with 'cap-rendering-device' label is invalid") and its sentinel
+ log shows such a gap.
A test with any FAIL or XPASS case, or that crashed or timed out without
starvation evidence, is not retried: it fails the run as before. The retry
@@ -31,6 +32,9 @@ import xml.etree.ElementTree as ET
STARVATION_GAP_MS = 100.0
QUEUE_DRAIN_PANIC = "We timed out while waiting on the last successful submission"
+# The GPU device was lost (WARP gives up on work that takes too long) and the
+# next wgpu call on it panics instead of reporting an error.
+DEVICE_LOST_PANIC = "Device with 'cap-rendering-device' label is invalid"
def records(report_dir):
@@ -95,6 +99,10 @@ def main():
blocking += 1
elif timed_out and longest >= STARVATION_GAP_MS:
print(f"{binary}\t{name}\ttimed out; sentinel longest wake gap {longest:.0f} ms")
+ elif DEVICE_LOST_PANIC in text and longest >= STARVATION_GAP_MS:
+ # Product hazard too (a lost device should be an error, not a
+ # panic), excused only under the sentinel's evidence.
+ print(f"{binary}\t{name}\twgpu device lost; sentinel longest wake gap {longest:.0f} ms")
elif QUEUE_DRAIN_PANIC in text and longest >= STARVATION_GAP_MS:
# wgpu-core gives a queue 6.3 s to finish its GPU work when the
# last handle drops, then panics. A product lifecycle hazard (the