Skip to content

The most powerful and modular diffusion model GUI, api and backend with a graph/nodes interface. The fastest local inference engine in the world.

I don't think controlnets were being handled correctly by MPS.

comfyanonymous4adcea722879
diff --git a/comfy/model_management.py b/comfy/model_management.py
index dfeef81a5..0d5702b91 100644
--- a/comfy/model_management.py
+++ b/comfy/model_management.py
@@ -62,8 +62,7 @@ if "--novram" in sys.argv:
set_vram_to = NO_VRAM
if "--highvram" in sys.argv:
vram_state = HIGH_VRAM
-if torch.backends.mps.is_available():
- vram_state = MPS
+
if set_vram_to == LOW_VRAM or set_vram_to == NO_VRAM:
try:
@@ -78,6 +77,12 @@ if set_vram_to == LOW_VRAM or set_vram_to == NO_VRAM:
total_vram_available_mb = (total_vram - 1024) // 2
total_vram_available_mb = int(max(256, total_vram_available_mb))
+try:
+ if torch.backends.mps.is_available():
+ vram_state = MPS
+except:
+ pass
+
if "--cpu" in sys.argv:
vram_state = CPU
@@ -152,9 +157,6 @@ def load_controlnet_gpu(models):
global vram_state
if vram_state == CPU:
return
-
- if vram_state == MPS:
- return
if vram_state == LOW_VRAM or vram_state == NO_VRAM:
#don't load controlnets like this if low vram because they will be loaded right before running and unloaded right after
@@ -164,9 +166,10 @@ def load_controlnet_gpu(models):
if m not in models:
m.cpu()
+ device = get_torch_device()
current_gpu_controlnets = []
for m in models:
- current_gpu_controlnets.append(m.cuda())
+ current_gpu_controlnets.append(m.to(device))
def load_if_low_vram(model):