fix(desktop): survive a launch by an interpreter without pywebview

rubenluetke10-beep76c82370b0e0
diff --git a/jarvis/ui/desktop_app.py b/jarvis/ui/desktop_app.py
index 6e43df220f..70ff80a579 100644
--- a/jarvis/ui/desktop_app.py
+++ b/jarvis/ui/desktop_app.py
@@ -436,6 +436,14 @@ def _install_desktop_log_sink(log_path: Path) -> None:
root.setLevel(_logging.INFO)
logger.info("Desktop log sink active: {}", log_path)
+ # Which interpreter is running the app is the first question a boot failure
+ # raises, and the log never answered it. A machine carries several Python
+ # installations, and a shortcut, scheduled task or launcher that resolves to
+ # a different one than the app was installed into looks exactly like "it
+ # suddenly stopped starting" (forensic 2026-08-09: a Start-menu shortcut
+ # pointed at an interpreter without pywebview, so the window import died
+ # 8 ms into boot). One line, every platform, no imports.
+ logger.info("Interpreter: {} (Python {}.{}.{})", sys.executable, *sys.version_info[:3])
_CRASH_HOOKS_INSTALLED = False
@@ -4480,7 +4488,25 @@ class DesktopApp:
)
enable_webview_accessibility_tree()
- import webview # type: ignore[import-not-found]
+ try:
+ import webview # type: ignore[import-not-found]
+ except ModuleNotFoundError as exc:
+ # pywebview is missing from THIS interpreter — which does not mean
+ # it is missing from the machine. With several Python installations
+ # around, a shortcut, scheduled task or launcher that resolves to
+ # the wrong one lands here (forensic 2026-08-09), as does an install
+ # that skipped the ``[desktop]`` extra. Crashing would also kill the
+ # backend thread that is already booting, so take the same honest
+ # degradation the missing-native-backend case takes, and name the
+ # interpreter — that name IS the diagnosis.
+ return self._degrade_to_browser_ui(
+ exc,
+ remedy=(
+ " - Or install the desktop dependencies into the "
+ "interpreter that is running the app:\n"
+ f" {sys.executable} -m pip install -e \".[desktop]\"\n"
+ ),
+ )
if not self._wait_for_backend():
sys.stderr.write("Backend did not start within 45s — aborting.\n")
@@ -4605,15 +4631,22 @@ class DesktopApp:
os._exit(code)
return code
- def _degrade_to_browser_ui(self, exc: BaseException) -> int:
+ def _degrade_to_browser_ui(
+ self, exc: BaseException, *, remedy: str | None = None
+ ) -> int:
"""Fallback when no native desktop-window backend is available.
- Reached only when pywebview cannot open a native window — in practice a
- Linux host missing the system GTK+WebKit packages (``gi`` +
- ``webkit2gtk``) that pip cannot install. The backend thread is already
- running and serving the full UI over HTTP, so instead of crashing (which
- would also kill that daemon thread) we keep it alive and point the user
- at the local URL, the packages to install, or the ``--headless`` mode.
+ Reached when pywebview cannot open a native window: a Linux host missing
+ the system GTK+WebKit packages (``gi`` + ``webkit2gtk``) that pip cannot
+ install, or an interpreter that does not have pywebview at all. The
+ backend thread is already running and serving the full UI over HTTP, so
+ instead of crashing (which would also kill that daemon thread) we keep it
+ alive and point the user at the local URL, the fix, or ``--headless``.
+
+ ``remedy`` replaces the default install hint with one that fits the
+ actual cause; the caller knows which of the two it hit, and a GTK
+ instruction on a Windows box with the wrong interpreter would send the
+ user chasing the wrong problem.
Blocks the main thread on the backend thread so the server keeps serving
until the user stops it (Ctrl+C) or it exits. Windows/macOS never reach
@@ -4623,6 +4656,20 @@ class DesktopApp:
url = f"http://127.0.0.1:{self.cfg.ui.admin_api_port}"
_logger.warning("Native desktop window unavailable: {}", exc)
+ # The message below goes to stderr, which a windowless launch (pythonw,
+ # a shortcut, the tray) throws away — so the log has to carry the two
+ # facts on its own: where the UI still is, and which interpreter failed.
+ _logger.warning(
+ "Browser-UI fallback: UI stays reachable at {} (interpreter: {}).",
+ url,
+ sys.executable,
+ )
+ default_remedy = (
+ " - Or install the system GTK 3 + WebKit2GTK packages pywebview "
+ "needs and restart\n"
+ " (Debian/Ubuntu, for example: "
+ "'sudo apt install python3-gi gir1.2-webkit2-4.1').\n"
+ )
message = (
"\n"
"Personal Jarvis could not open a native desktop window.\n"
@@ -4630,10 +4677,7 @@ class DesktopApp:
"\n"
"The backend is running and already serving the full UI. To use it:\n"
f" - Open this address in a web browser: {url}\n"
- " - Or install the system GTK 3 + WebKit2GTK packages pywebview "
- "needs and restart\n"
- " (Debian/Ubuntu, for example: "
- "'sudo apt install python3-gi gir1.2-webkit2-4.1').\n"
+ f"{remedy or default_remedy}"
" - Or re-run without a window using the '--headless' flag.\n"
"\n"
"Press Ctrl+C to stop the server.\n"