Skip to content

Dodaios is an open-source agent OS for your desktop: it runs your coding agents, browser and apps by voice or chat, on your own machine. Formerly Personal Jarvis.

fix(autostart): write the startup entry in-process, without spawning PowerShell (#724)

Ruben Lütke9d1415a5baf3
diff --git a/jarvis/autostart/windows.py b/jarvis/autostart/windows.py
index 276a7eac5e..1e2693383e 100644
--- a/jarvis/autostart/windows.py
+++ b/jarvis/autostart/windows.py
@@ -22,11 +22,19 @@ account's filtered token). *Reading* a task's state does not. So:
works (just possibly delayed). The Settings panel surfaces an "enable instant
start" affordance to upgrade the fallback to a task.
-Everything shells out to PowerShell (subprocess) exactly like
-``scripts/install_shortcuts.py`` — **no ``pywin32`` dependency**. The
+The silent paths — the task probe and the fallback ``.lnk`` read/write that the
+boot reconcile runs on every start, including the very first one — talk to the
+Task Scheduler and ``WScript.Shell`` **in-process** through pywin32 COM. They
+used to shell out to ``powershell.exe -ExecutionPolicy Bypass``, and an app that
+spawns a hidden PowerShell on its first launch to drop a shortcut into the
+Startup folder is exactly the chain behaviour-based antivirus blocks: Bitdefender
+quarantined the v3.2.0 install for it (issue #713, ``explorer.exe ->
+personaljarvis.exe -> powershell.exe``). PowerShell remains only as a fallback
+for a host without pywin32, for a Store Python whose in-process writes would be
+redirected into its MSIX container (BUG-138), and for the one-time elevated task
+registration the user starts from Settings and confirms in a UAC prompt. The
script-assembly functions are pure (unit-testable cross-platform); only execution
-requires Windows. The ``.lnk`` builders (``build_create_script`` /
-``build_read_script``) are unchanged and still used for the fallback.
+requires Windows.
"""
from __future__ import annotations
@@ -38,9 +46,11 @@ import ntpath
import os
import subprocess
import tempfile
-from collections.abc import Callable
+from collections.abc import Callable, Iterator
+from contextlib import contextmanager
from dataclasses import dataclass
from pathlib import Path
+from typing import TypeVar
from jarvis.core.branding import (
WINDOWS_AUTOSTART_DESCRIPTION,
@@ -57,6 +67,8 @@ from .protocol import AutostartStatus, LaunchSpec
log = logging.getLogger(__name__)
+_T = TypeVar("_T")
+
# Scheduled-task identity. A stable name so reconcile can find/refresh it.
# How long after login the task waits before launching — lets the desktop settle
# without the multi-minute Explorer startup throttle.
@@ -388,11 +400,12 @@ def _tag_shortcut_aumid(link: Path) -> bool:
propsys.PROPVARIANTType(APP_USER_MODEL_ID),
)
store.Commit()
- # The .lnk itself is created by a PowerShell child, which is why it
- # reaches the real Startup folder under a Store Python (BUG-138). This
- # commit runs IN-PROCESS, so it is redirected: it would leave the real
- # shortcut untagged and drop a container copy that masks it from every
- # later in-process read. Publishing puts the tagged version back.
+ # Under a Store Python the .lnk itself is created by a PowerShell
+ # child, which is why it reaches the real Startup folder (BUG-138).
+ # This commit runs IN-PROCESS, so there it is redirected: it would
+ # leave the real shortcut untagged and drop a container copy that
+ # masks it from every later in-process read. Publishing puts the
+ # tagged version back (a no-op on an unpackaged interpreter).
from jarvis.ui.msix_redirection import publish_out_of_container
if not publish_out_of_container(link):
@@ -404,6 +417,170 @@ def _tag_shortcut_aumid(link: Path) -> bool:
return False
+# --------------------------------------------------------------------------- #
+# In-process COM (the silent paths; no child process at all) #
+# --------------------------------------------------------------------------- #
+
+
+def _win32com() -> tuple[object, object] | None:
+ """``(pythoncom, win32com.client)``, or ``None`` when pywin32 is absent.
+
+ Lazy (HN-7): this module is imported on every OS, pywin32 exists only on
+ Windows, and only in the ``desktop`` extra. The frozen installer build
+ always bundles it (``jarvis.spec`` hidden imports).
+ """
+ try:
+ import pythoncom # type: ignore[import-not-found]
+ import win32com.client # type: ignore[import-not-found]
+ except Exception: # noqa: BLE001 — absent or broken pywin32 → PowerShell fallback
+ return None
+ return pythoncom, win32com.client
+
+
+@contextmanager
+def _com_apartment(pythoncom: object) -> Iterator[None]:
+ """Initialise COM on the calling thread for the duration of the block.
+
+ The boot reconcile runs on a worker thread that has never touched COM. A
+ thread that already joined a different apartment refuses re-initialisation
+ (``RPC_E_CHANGED_MODE``) but can use COM as it is, so that is not an error.
+ """
+ try:
+ pythoncom.CoInitialize() # type: ignore[attr-defined]
+ except Exception: # noqa: BLE001 — already initialised in another mode
+ yield
+ return
+ try:
+ yield
+ finally:
+ pythoncom.CoUninitialize() # type: ignore[attr-defined]
+
+
+def _shortcut_needs_helper(link: Path) -> bool:
+ """Would an in-process write to ``link`` land in an MSIX container?
+
+ Only a Store Python is packaged; its writes under ``%APPDATA%`` are
+ redirected where Explorer never looks (BUG-138), which is why the shortcut
+ was written by a PowerShell child in the first place. Every other host —
+ the installer build above all — writes in-process.
+ """
+ try:
+ from jarvis.ui.msix_redirection import redirects_writes
+
+ return redirects_writes(link)
+ except Exception as exc: # noqa: BLE001 — undecidable → the proven helper path
+ log.debug("MSIX redirection check failed for %s: %s", link, exc)
+ return True
+
+
+def _run_com(work: Callable[[object, object], _T]) -> _T:
+ """Run ``work(pythoncom, win32com.client)`` inside a COM apartment.
+
+ Raises :class:`LookupError` when pywin32 is unavailable, so a caller can
+ fall back to PowerShell. Every COM proxy ``work`` creates lives in its own
+ frame and is released when it returns, i.e. BEFORE ``CoUninitialize`` — a
+ proxy released after it makes pywin32 complain on every call. For the same
+ reason a failure is re-raised as a plain :class:`OSError` once the
+ apartment is closed: the original traceback would keep the proxies alive.
+ """
+ com = _win32com()
+ if com is None:
+ raise LookupError("pywin32 is not available")
+ pythoncom, client = com
+ with _com_apartment(pythoncom):
+ try:
+ return work(pythoncom, client)
+ except Exception as exc: # noqa: BLE001 — re-raised below, proxy-free
+ error = f"{type(exc).__name__}: {exc}"
+ raise OSError(error)
+
+
+def _read_task(pythoncom: object, client: object, task_name: str) -> _TaskInfo | None:
+ service = client.Dispatch("Schedule.Service") # type: ignore[attr-defined]
+ service.Connect()
+ try:
+ task = service.GetFolder("\\").GetTask(task_name)
+ except pythoncom.com_error: # type: ignore[attr-defined]
+ return None # not registered
+ actions = task.Definition.Actions
+ action = actions.Item(1) if actions.Count else None
+ return _TaskInfo(
+ execute=str(getattr(action, "Path", "") or ""),
+ arguments=str(getattr(action, "Arguments", "") or ""),
+ working_dir=str(getattr(action, "WorkingDirectory", "") or ""),
+ enabled=bool(task.Enabled),
+ )
+
+
+def _query_task_in_process(task_name: str) -> _TaskInfo | None:
+ """Read the logon task through the Task Scheduler COM API.
+
+ Raises :class:`LookupError` when pywin32 is unavailable so the caller can
+ fall back; any other failure propagates and the caller treats it as "no
+ task", the same rule the PowerShell query follows.
+ """
+ return _run_com(lambda pythoncom, client: _read_task(pythoncom, client, task_name))
+
+
+def _save_shortcut(client: object, link: Path, spec: LaunchSpec, icon: str | None) -> None:
+ sc = client.Dispatch("WScript.Shell").CreateShortcut(str(link)) # type: ignore[attr-defined]
+ sc.TargetPath = spec.program
+ sc.Arguments = " ".join(spec.args)
+ sc.WorkingDirectory = spec.working_dir
+ sc.Description = WINDOWS_AUTOSTART_DESCRIPTION
+ if icon:
+ sc.IconLocation = f"{icon},0"
+ sc.WindowStyle = 7 if spec.minimized else 1
+ sc.Save()
+
+
+def _load_shortcut(client: object, link: Path) -> list[str]:
+ sc = client.Dispatch("WScript.Shell").CreateShortcut(str(link)) # type: ignore[attr-defined]
+ return [
+ str(sc.TargetPath or ""),
+ str(sc.Arguments or ""),
+ str(sc.WorkingDirectory or ""),
+ str(sc.IconLocation or ""),
+ ]
+
+
+def _write_shortcut_in_process(link: Path, spec: LaunchSpec, *, icon: str | None) -> bool:
+ """Create/refresh the fallback ``.lnk`` in-process. ``False`` = not possible here.
+
+ Writes the same fields as :func:`build_create_script`.
+ """
+ if _shortcut_needs_helper(link):
+ return False
+ try:
+ _run_com(lambda _pythoncom, client: _save_shortcut(client, link, spec, icon))
+ except LookupError: # no pywin32 here - the caller writes through PowerShell
+ return False
+ return True
+
+
+def _read_shortcut_in_process(link: Path) -> list[str] | None:
+ """TargetPath/Arguments/WorkingDirectory/IconLocation; ``None`` = not possible here.
+
+ A Store Python would read its own container copy rather than the shortcut
+ Explorer sees, so it keeps reading through the helper.
+ """
+ if _shortcut_needs_helper(link):
+ return None
+ try:
+ return _run_com(lambda _pythoncom, client: _load_shortcut(client, link))
+ except LookupError: # no pywin32 here - the caller reads through PowerShell
+ return None
+
+
+def _read_shortcut_fields(link: Path) -> list[str]:
+ """The shortcut's four read-back fields, in-process when possible."""
+ fields = _read_shortcut_in_process(link)
+ if fields is not None:
+ return fields
+ result = _run_powershell(build_read_script(link))
+ return _sentinel_fields(result.stdout, _READBACK_SENTINEL)
+
+
def _run_powershell(script: str) -> subprocess.CompletedProcess[str]:
# encoding/errors are pinned rather than left to the locale: without them
# Python decodes the pipe with the ANSI code page while PowerShell wrote it
@@ -696,6 +873,13 @@ class WindowsAutostart:
# ---- real (live) default operations ------------------------------------
def _default_task_probe(self) -> _TaskInfo | None:
+ try:
+ return _query_task_in_process(self._task_name)
+ except LookupError:
+ pass # no pywin32 → the PowerShell query below
+ except Exception as exc: # noqa: BLE001 — query failure → treat as absent
+ log.debug("scheduled-task query failed: %s", exc)
+ return None
try:
result = _run_powershell(build_query_task_script(self._task_name))
except Exception as exc: # noqa: BLE001 — query failure → treat as absent
@@ -707,11 +891,10 @@ class WindowsAutostart:
if not self._path.exists():
return False
try:
- result = _run_powershell(build_read_script(self._path))
+ fields = _read_shortcut_fields(self._path)
except Exception as exc: # noqa: BLE001 — unreadable → not a match
log.debug("shortcut read failed: %s", exc)
return False
- fields = _sentinel_fields(result.stdout, _READBACK_SENTINEL)
if len(fields) < 4:
# A truncated read-back is "unknown", not "matches". Padding the
# missing fields with "" made a half-failed COM read compare equal
@@ -744,7 +927,9 @@ class WindowsAutostart:
def _default_write_shortcut(self, spec: LaunchSpec) -> None:
self._path.parent.mkdir(parents=True, exist_ok=True)
self._remove_legacy()
- _run_powershell(build_create_script(self._path, spec, icon=_resolve_app_icon()))
+ icon = _resolve_app_icon()
+ if not _write_shortcut_in_process(self._path, spec, icon=icon):
+ _run_powershell(build_create_script(self._path, spec, icon=icon))
# Tag the shortcut with the SAME AUMID as the Start-Menu shortcut so the
# two same-named .lnk files don't diverge and confuse the shell's taskbar
# button resolution (best-effort; a box without pywin32 still gets the
diff --git a/tests/unit/autostart/test_windows_task.py b/tests/unit/autostart/test_windows_task.py
index 01de5e5156..92ac888422 100644
--- a/tests/unit/autostart/test_windows_task.py
+++ b/tests/unit/autostart/test_windows_task.py
@@ -412,6 +412,8 @@ def test_truncated_shortcut_readback_is_drift_not_a_match(monkeypatch) -> None:
bare = LaunchSpec(program=r"C:\Python\pythonw.exe", args=(), working_dir="")
encoded = base64.b64encode(bare.program.encode("utf-8")).decode("ascii")
monkeypatch.setattr(Path, "exists", lambda self: True)
+ # Force the PowerShell read-back path: in-process COM is "not possible here".
+ monkeypatch.setattr(win_mod, "_read_shortcut_in_process", lambda link: None)
monkeypatch.setattr(
win_mod,
"_run_powershell",
@@ -528,3 +530,79 @@ def test_elevated_launcher_fails_safe_on_a_null_exit_code(monkeypatch) -> None:
assert "if ($null -eq $p -or $null -eq $p.ExitCode) { exit 1 }" in launcher
# The guard must come BEFORE the forwarding exit, or it changes nothing.
assert launcher.index("$null -eq $p.ExitCode") < launcher.index("exit $p.ExitCode")
+
+
+# --------------------------------------------------------------------------- #
+# Silent paths stay in-process (issue #713: Bitdefender blocked the app for #
+# spawning powershell.exe on its first launch to write the startup shortcut) #
+# --------------------------------------------------------------------------- #
+
+
+def _no_powershell(script: str):
+ raise AssertionError("the silent autostart path must not spawn PowerShell")
+
+
+def test_boot_reconcile_writes_the_shortcut_without_powershell(monkeypatch, tmp_path) -> None:
+ from jarvis.autostart import windows as win_mod
+
+ written: list[tuple[object, LaunchSpec, object]] = []
+ monkeypatch.setattr(win_mod, "_run_powershell", _no_powershell)
+ monkeypatch.setattr(win_mod, "_tag_shortcut_aumid", lambda link: True)
+ monkeypatch.setattr(win_mod, "_startup_dir", lambda: tmp_path)
+ monkeypatch.setattr(
+ win_mod,
+ "_write_shortcut_in_process",
+ lambda link, spec, icon: written.append((link, spec, icon)) or True,
+ )
+ mgr = WindowsAutostart(task_probe=lambda: None, run_elevated=lambda s: False)
+ mgr.install(_SPEC)
+ assert len(written) == 1
+ assert written[0][1] == _SPEC
+
+
+def test_shortcut_falls_back_to_powershell_only_when_in_process_is_impossible(
+ monkeypatch, tmp_path
+) -> None:
+ from jarvis.autostart import windows as win_mod
+
+ scripts: list[str] = []
+ monkeypatch.setattr(win_mod, "_run_powershell", lambda script: scripts.append(script))
+ monkeypatch.setattr(win_mod, "_tag_shortcut_aumid", lambda link: True)
+ monkeypatch.setattr(win_mod, "_startup_dir", lambda: tmp_path)
+ monkeypatch.setattr(win_mod, "_write_shortcut_in_process", lambda link, spec, icon: False)
+ WindowsAutostart()._default_write_shortcut(_SPEC)
+ assert len(scripts) == 1
+ assert "CreateShortcut" in scripts[0]
+
+
+def test_task_probe_uses_com_and_skips_powershell(monkeypatch) -> None:
+ from jarvis.autostart import windows as win_mod
+
+ monkeypatch.setattr(win_mod, "_run_powershell", _no_powershell)
+ monkeypatch.setattr(win_mod, "_query_task_in_process", lambda name: _MATCHING_INFO)
+ assert WindowsAutostart()._default_task_probe() == _MATCHING_INFO
+
+
+def test_task_probe_com_failure_reads_as_absent_not_powershell(monkeypatch) -> None:
+ from jarvis.autostart import windows as win_mod
+
+ def boom(name: str):
+ raise OSError("Task Scheduler unavailable")
+
+ monkeypatch.setattr(win_mod, "_run_powershell", _no_powershell)
+ monkeypatch.setattr(win_mod, "_query_task_in_process", boom)
+ assert WindowsAutostart()._default_task_probe() is None
+
+
+def test_task_probe_without_pywin32_falls_back_to_powershell(monkeypatch) -> None:
+ import subprocess
+
+ from jarvis.autostart import windows as win_mod
+
+ monkeypatch.setattr(win_mod, "_win32com", lambda: None)
+ monkeypatch.setattr(
+ win_mod,
+ "_run_powershell",
+ lambda script: subprocess.CompletedProcess(["powershell"], 0, stdout="", stderr=""),
+ )
+ assert WindowsAutostart()._default_task_probe() is None