Machine A — Equipment Manual (Simulated)

This is a fictional equipment manual written for a simulated demo machine. It does not describe any real industrial equipment.

Normal Operating Ranges

Under normal operation, Machine A's sensors should read within the following ranges:

  • Temperature: 65–75°C
  • Vibration: 1.5–3.0 mm/s
  • Pressure: 4.5–5.5 bar
  • Status: running
  • Error code: none

Readings that drift outside these ranges, or a status of "warning" or "fault", indicate a developing issue and warrant investigation before the condition worsens.

Error Codes

The following error codes may appear on Machine A's control panel. Each one corresponds to a specific failure pattern and should be cross-referenced with the troubleshooting guide for detailed inspection steps.

BRG-02 — Bearing vibration warning

Symptoms:

  • vibration significantly above the normal 1.5–3.0 mm/s range, often climbing toward 7–8 mm/s or higher
  • temperature gradually rising above the normal range as friction increases
  • pressure remains within its normal range

BRG-02 indicates the main shaft bearing assembly is showing signs of wear. See the troubleshooting guide's bearing section for inspection steps.

TMP-04 — Cooling system temperature warning

Symptoms:

  • temperature rising well above the normal 65–75°C range, sometimes exceeding 95°C
  • vibration remains near its normal range
  • pressure remains near its normal range

TMP-04 indicates the cooling system is not removing heat effectively. See the troubleshooting guide's cooling section for inspection steps.

PRS-03 — Pressure loss warning

Symptoms:

  • pressure dropping below the normal 4.5–5.5 bar range, sometimes below 3 bar
  • temperature may be mildly elevated above normal
  • vibration remains near its normal range

PRS-03 indicates a loss of pressure somewhere in the system, most often from a seal, hose, or fitting. See the troubleshooting guide's pressure section for inspection steps.