Equipment Failure Case Analysis Report
Report Number: FA-2024-001 Preparation Date: March 15, 2024 Equipment Name: Automated Assembly Line A1 - Main Motor Failure Date: January 10, 2024
1. Failure Overview
1.1 Equipment Information
| Item | Content |
|---|---|
| Equipment ID | MTR-001 |
| Equipment Name | Main Motor |
| Model | DM-750 |
| Manufacturer | Power Drive Co., Ltd. |
| Installation Location | Manufacturing Workshop A, Zone 1 |
| Commissioning Date | June 2022 |
1.2 Failure Phenomenon
At 9:30 AM on January 10, 2024, the main motor (MTR-001) of Automated Assembly Line A1 suddenly emitted abnormal sounds during operation, accompanied by significantly increased vibration. The operator immediately pressed the emergency stop button, and the equipment stopped running.
Specific Phenomena:
- Motor emitted sharp metal friction sound
- Vibration amplitude exceeded normal value by 3 times
- Bearing temperature rapidly rose to 85°C
- Inverter displayed abnormal current fluctuation
2. Failure Analysis
2.1 Initial Inspection
After arriving at the site, maintenance personnel conducted initial inspection:
- Visual Inspection: No obvious damage to motor housing, no abnormal odor
- Insulation Test: Winding insulation resistance normal, ruled out short circuit possibility
- Vibration Test: Vibration value exceeded standard, mainly concentrated at bearing area
- Temperature Test: Bearing seat temperature was high at 85°C
2.2 In-depth Analysis
After disassembly and inspection, the root cause of the failure was confirmed as follows:
Main Cause: Severe bearing wear
- Bearing raceway showed obvious wear marks
- Rolling element surface had spalling phenomenon
- Lubricating grease turned black and deteriorated, losing lubrication function
Secondary Cause: Long-term lack of preventive maintenance
- The motor had not undergone bearing replacement since commissioning
- Lubricating grease was not regularly supplemented as required
- Operating load had been at high-load state for a long time
3. Handling Measures
3.1 Emergency Handling
- Immediately stopped equipment operation and cut off power
- Marked fault status and hung warning signs
- Started backup motor to maintain production
3.2 Root Cause Treatment
- Bearing Replacement: Replaced bearing with same specification (Model: 6208-2RS)
- Lubricating Grease Supplementation: Used high-quality lubricating grease (Model: L-XBCHA3)
- Bearing Seat Cleaning: Thoroughly removed old lubricating grease and impurities
- Electrical Testing: Tested winding resistance to ensure normal electrical performance