Equipment Failure Case Analysis Report

Report Number: FA-2024-001 Preparation Date: March 15, 2024 Equipment Name: Automated Assembly Line A1 - Main Motor Failure Date: January 10, 2024


1. Failure Overview

1.1 Equipment Information

Item Content
Equipment ID MTR-001
Equipment Name Main Motor
Model DM-750
Manufacturer Power Drive Co., Ltd.
Installation Location Manufacturing Workshop A, Zone 1
Commissioning Date June 2022

1.2 Failure Phenomenon

At 9:30 AM on January 10, 2024, the main motor (MTR-001) of Automated Assembly Line A1 suddenly emitted abnormal sounds during operation, accompanied by significantly increased vibration. The operator immediately pressed the emergency stop button, and the equipment stopped running.

Specific Phenomena:

  • Motor emitted sharp metal friction sound
  • Vibration amplitude exceeded normal value by 3 times
  • Bearing temperature rapidly rose to 85°C
  • Inverter displayed abnormal current fluctuation

2. Failure Analysis

2.1 Initial Inspection

After arriving at the site, maintenance personnel conducted initial inspection:

  1. Visual Inspection: No obvious damage to motor housing, no abnormal odor
  2. Insulation Test: Winding insulation resistance normal, ruled out short circuit possibility
  3. Vibration Test: Vibration value exceeded standard, mainly concentrated at bearing area
  4. Temperature Test: Bearing seat temperature was high at 85°C

2.2 In-depth Analysis

After disassembly and inspection, the root cause of the failure was confirmed as follows:

Main Cause: Severe bearing wear

  • Bearing raceway showed obvious wear marks
  • Rolling element surface had spalling phenomenon
  • Lubricating grease turned black and deteriorated, losing lubrication function

Secondary Cause: Long-term lack of preventive maintenance

  • The motor had not undergone bearing replacement since commissioning
  • Lubricating grease was not regularly supplemented as required
  • Operating load had been at high-load state for a long time

3. Handling Measures

3.1 Emergency Handling

  1. Immediately stopped equipment operation and cut off power
  2. Marked fault status and hung warning signs
  3. Started backup motor to maintain production

3.2 Root Cause Treatment

  1. Bearing Replacement: Replaced bearing with same specification (Model: 6208-2RS)
  2. Lubricating Grease Supplementation: Used high-quality lubricating grease (Model: L-XBCHA3)
  3. Bearing Seat Cleaning: Thoroughly removed old lubricating grease and impurities
  4. Electrical Testing: Tested winding resistance to ensure normal electrical performance

3.3 Treatment Results