Skip to content

Never stop coding. Free MIT AI gateway: one endpoint, 375 providers (150+ free), 1,400+ models Kimi, Claude, GPT, Gemini, GLM, DeepSeek, MiniMax. Works with Claude Code, Codex, Cursor, OpenCode, Cline & Copilot. Quota-aware auto-fallback, RTK+Caveman compression saves 15-95% tokens, MCP/A2A, Desktop/PWA. Built by 900+ contributors

feat(account-fallback): add daily quota lockout for quota_exhausted errors (#1644)

diegosouzapw78b845b68c79
diff --git a/open-sse/services/accountFallback.ts b/open-sse/services/accountFallback.ts
index 74bc593f6c..19c8be2e43 100644
--- a/open-sse/services/accountFallback.ts
+++ b/open-sse/services/accountFallback.ts
@@ -345,6 +345,12 @@ export function recordModelLockoutFailure(
const now = Date.now();
cleanupModelLockKey(key, now);
+ // For daily quota exhaustion (quota_exhausted), set cooldown until tomorrow 00:00
+ // Use exactCooldownMs to bypass exponential backoff, ensuring precise lock until midnight
+ if (reason === "quota_exhausted" && typeof options.exactCooldownMs !== "number") {
+ options = { ...options, exactCooldownMs: getMsUntilTomorrow() };
+ }
+
const resetAfterMs = getFailureWindowMs(profile);
const previous = modelFailureState.get(key);
const withinWindow = previous && now - previous.lastFailureAt <= previous.resetAfterMs;
@@ -770,11 +776,12 @@ export function classifyError(status, errorText) {
* @returns {number} Milliseconds until tomorrow
*/
export function getMsUntilTomorrow(): number {
- const now = new Date();
- const tomorrow = new Date(now);
+ const nowMs = Date.now();
+ const now = new Date(nowMs);
+ const tomorrow = new Date(nowMs);
tomorrow.setDate(tomorrow.getDate() + 1);
tomorrow.setHours(0, 0, 0, 0);
- const ms = tomorrow.getTime() - now.getTime();
+ const ms = tomorrow.getTime() - nowMs;
// Guard against DST edge cases: if ms is negative (shouldn't happen) or
// unreasonably large (>25h due to spring-forward), cap at 24 hours.
return ms > 0 && ms <= 25 * 60 * 60 * 1000 ? ms : 24 * 60 * 60 * 1000;
diff --git a/src/sse/handlers/chat.ts b/src/sse/handlers/chat.ts
index 6151a60706..d9bf0763e7 100644
--- a/src/sse/handlers/chat.ts
+++ b/src/sse/handlers/chat.ts
@@ -9,6 +9,9 @@ import {
getRuntimeProviderProfile,
shouldMarkAccountExhaustedFrom429,
clearModelLock,
+ lockModel,
+ recordModelLockoutFailure,
+ isDailyQuotaExhausted,
} from "@omniroute/open-sse/services/accountFallback.ts";
import { getModelInfo, getComboForModel } from "../services/model";
import { errorResponse } from "@omniroute/open-sse/utils/error.ts";
@@ -827,18 +830,55 @@ async function handleSingleModelChat(
}
}
- // 6. Mark account as quota-exhausted on 429 response
+ // 6. Daily quota error check - must be executed before markAccountUnavailable
+ // Check if it's a daily quota exhausted error (e.g., ModelScope/Kimi "today's quota for model")
+ // Daily quota lockout overrides subsequent rate_limited lockout, ensuring lockout until tomorrow 0:00
+ let dailyQuotaExhausted = false;
+ const errorStr = String(result.error || "");
+ if (result.status === 429 && isDailyQuotaExhausted(errorStr)) {
+ // Parse which model is quota-limited
+ const match = errorStr.match(/today's quota for model ([^,]+)/);
+ const limitedModel = match ? match[1].trim() : model;
+
+ // Lock this model on this connection until tomorrow 00:00
+ const lockResult = recordModelLockoutFailure(
+ provider,
+ credentials.connectionId,
+ limitedModel,
+ "quota_exhausted",
+ result.status,
+ 0,
+ providerProfile
+ );
+
+ log.info(
+ "MODEL_DAILY_QUOTA",
+ JSON.stringify({
+ connection: credentials.connectionId.slice(0, 8),
+ model: limitedModel,
+ cooldownMs: lockResult.cooldownMs,
+ failureCount: lockResult.failureCount,
+ })
+ );
+
+ dailyQuotaExhausted = true;
+ }
+
+ // 7. Mark account as quota-exhausted on 429 response (non-daily-quota errors)
// For providers that route quota/cooldown at model scope, a 429 on one model
// does not mean the whole connection is exhausted.
- const passthroughModels = credentials.providerSpecificData?.passthroughModels;
- if (
- result.status === 429 &&
- shouldMarkAccountExhaustedFrom429(provider, model, passthroughModels)
- ) {
- markAccountExhaustedFrom429(credentials.connectionId, provider);
+ // Daily quota errors are handled above; only process regular rate_limit here
+ if (!dailyQuotaExhausted) {
+ const passthroughModels = credentials.providerSpecificData?.passthroughModels;
+ if (
+ result.status === 429 &&
+ shouldMarkAccountExhaustedFrom429(provider, model, passthroughModels)
+ ) {
+ markAccountExhaustedFrom429(credentials.connectionId, provider);
+ }
}
- // 7. Fallback to next account
+ // 8. Fallback to next account
const { shouldFallback, cooldownMs } = await markAccountUnavailable(
credentials.connectionId,
result.status,
diff --git a/tests/unit/account-fallback-service.test.ts b/tests/unit/account-fallback-service.test.ts
index 8e49cdd6d2..a72518e7ba 100644
--- a/tests/unit/account-fallback-service.test.ts
+++ b/tests/unit/account-fallback-service.test.ts
@@ -613,3 +613,119 @@ test("checkFallbackError preserves OAuth 429 daily quota semantics", () => {
assert.equal(result.dailyQuotaExhausted, true);
assert.ok(result.cooldownMs > 0);
});
+
+// ModelScope daily quota lockout tests (commit 0456a1f5)
+test("recordModelLockoutFailure sets cooldown until tomorrow 0:00 for quota_exhausted reason", () => {
+ const originalNow = Date.now;
+ // Use a fixed local time (noon) to ensure predictable results
+ const testDate = new Date();
+ testDate.setHours(12, 0, 0, 0); // Set to noon today
+ const now = testDate.getTime();
+ Date.now = () => now;
+
+ try {
+ const provider = "modelscope";
+ const connectionId = "test-conn-modelscope-1";
+ const model = "qwen/Qwen2.5-Coder-32B-Instruct";
+
+ // Clear any existing state
+ clearModelLock(provider, connectionId, model);
+
+ const profile = {
+ baseCooldownMs: 125,
+ useUpstreamRetryHints: false,
+ maxBackoffSteps: 3,
+ failureThreshold: 60,
+ resetTimeoutMs: 5000,
+ };
+
+ // Calculate milliseconds until tomorrow 00:00 local time
+ const tomorrow = new Date(now);
+ tomorrow.setDate(tomorrow.getDate() + 1);
+ tomorrow.setHours(0, 0, 0, 0);
+ const expectedMsUntilTomorrow = tomorrow.getTime() - now;
+
+ // Account for timezone offset: function uses local time, test env may use UTC
+ const timezoneOffset = new Date().getTimezoneOffset() * 60 * 1000;
+
+ // Record failure with quota_exhausted reason
+ const result = recordModelLockoutFailure(
+ provider,
+ connectionId,
+ model,
+ "quota_exhausted",
+ 429,
+ 0, // fallbackCooldownMs should be overridden to ms until tomorrow
+ profile
+ );
+
+ // Verify the cooldown is set to ms until tomorrow 0:00 (with tolerance)
+ // The cooldown should be close to expectedMsUntilTomorrow
+ const tolerance = 60 * 1000; // 1 minute tolerance
+ // Calculate difference between actual and expected values
+ const diff = Math.abs(result.cooldownMs - expectedMsUntilTomorrow);
+
+ // Allow ±5 minutes tolerance (300,000 ms)
+ assert.ok(
+ diff <= 300_000,
+ `cooldown should be ms until tomorrow 0:00 (expected ${expectedMsUntilTomorrow}ms, got ${result.cooldownMs}ms, diff ${diff}ms)`
+ );
+
+ // Verify model is locked
+ assert.equal(isModelLocked(provider, connectionId, model), true);
+
+ const lockInfo = getModelLockoutInfo(provider, connectionId, model);
+ assert.ok(lockInfo !== null, "lockInfo should not be null");
+ assert.ok(lockInfo.remainingMs > 0, "remaining time should be positive");
+
+ clearModelLock(provider, connectionId, model);
+ } finally {
+ Date.now = originalNow;
+ clearModelLock("modelscope", "test-conn-modelscope-1", "qwen/Qwen2.5-Coder-32B-Instruct");
+ }
+});
+
+test("recordModelLockoutFailure uses regular backoff for non-quota reasons", () => {
+ const originalNow = Date.now;
+ const now = 1_700_000_000_000;
+ Date.now = () => now;
+
+ try {
+ const provider = "modelscope";
+ const connectionId = "test-conn-modelscope-2";
+ const model = "qwen/Qwen2.5-Coder-32B-Instruct";
+
+ clearModelLock(provider, connectionId, model);
+
+ const profile = {
+ baseCooldownMs: 5000,
+ useUpstreamRetryHints: false,
+ maxBackoffSteps: 3,
+ failureThreshold: 60,
+ resetTimeoutMs: 5000,
+ };
+
+ // Record failure with rate_limited reason (not quota_exhausted)
+ const result = recordModelLockoutFailure(
+ provider,
+ connectionId,
+ model,
+ "rate_limited",
+ 429,
+ 0,
+ profile
+ );
+
+ // Verify the cooldown uses regular profile baseCooldownMs (5000ms)
+ assert.ok(
+ result.cooldownMs < 24 * 60 * 60 * 1000,
+ "cooldown should be less than 24h for non-quota reasons"
+ );
+ assert.equal(result.cooldownMs, 5000, "cooldown should use profile baseCooldownMs");
+
+ clearModelLock(provider, connectionId, model);
+ } finally {
+ Date.now = originalNow;
+ clearModelLock("modelscope", "test-conn-modelscope-2", "qwen/Qwen2.5-Coder-32B-Instruct");
+ }
+});