π OpenHands: AI-Driven Development
Fix Docker runtimes not stopping (#6470)
tofarrffdab28abc5c
diff --git a/openhands/runtime/impl/docker/docker_runtime.py b/openhands/runtime/impl/docker/docker_runtime.pyindex 91621c2490..02ad760a0f 100644--- a/openhands/runtime/impl/docker/docker_runtime.py+++ b/openhands/runtime/impl/docker/docker_runtime.py@@ -1,6 +1,6 @@-import atexitfrom functools import lru_cachefrom typing import Callable+from uuid import UUIDimport dockerimport requests@@ -26,6 +26,7 @@ from openhands.runtime.utils.command import get_action_execution_server_startup_from openhands.runtime.utils.log_streamer import LogStreamerfrom openhands.runtime.utils.runtime_build import build_runtime_imagefrom openhands.utils.async_utils import call_sync_from_async+from openhands.utils.shutdown_listener import add_shutdown_listenerfrom openhands.utils.tenacity_stop import stop_if_should_exitCONTAINER_NAME_PREFIX = 'openhands-runtime-'@@ -36,13 +37,6 @@ APP_PORT_RANGE_1 = (50000, 54999)APP_PORT_RANGE_2 = (55000, 59999)-def stop_all_runtime_containers():- stop_all_containers(CONTAINER_NAME_PREFIX)---_atexit_registered = False--class DockerRuntime(ActionExecutionClient):"""This runtime will subscribe the event stream.When receive an event, it will send the event to runtime-client which run inside the docker environment.@@ -55,6 +49,8 @@ class DockerRuntime(ActionExecutionClient):env_vars (dict[str, str] | None, optional): Environment variables to set. Defaults to None."""+ _shutdown_listener_id: UUID | None = None+def __init__(self,config: AppConfig,@@ -66,10 +62,10 @@ class DockerRuntime(ActionExecutionClient):attach_to_existing: bool = False,headless_mode: bool = True,):- global _atexit_registered- if not _atexit_registered:- _atexit_registered = True- atexit.register(stop_all_runtime_containers)+ if not DockerRuntime._shutdown_listener_id:+ DockerRuntime._shutdown_listener_id = add_shutdown_listener(+ lambda: stop_all_containers(CONTAINER_NAME_PREFIX)+ )self.config = configself._runtime_initialized: bool = Falsediff --git a/openhands/utils/shutdown_listener.py b/openhands/utils/shutdown_listener.pyindex 5cf84a309c..eddaac54f0 100644--- a/openhands/utils/shutdown_listener.py+++ b/openhands/utils/shutdown_listener.py@@ -1,5 +1,6 @@"""-This module monitors the app for shutdown signals+This module monitors the app for shutdown signals. This exists because the atexit module+does not play nocely with stareltte / uvicorn shutdown signals."""import asyncio@@ -7,12 +8,15 @@ import signalimport threadingimport timefrom types import FrameType+from typing import Callable+from uuid import UUID, uuid4from uvicorn.server import HANDLED_SIGNALSfrom openhands.core.logger import openhands_logger as logger_should_exit = None+_shutdown_listeners: dict[UUID, Callable] = {}def _register_signal_handler(sig: signal.Signals):@@ -21,9 +25,16 @@ def _register_signal_handler(sig: signal.Signals):def handler(sig_: int, frame: FrameType | None):logger.debug(f'shutdown_signal:{sig_}')global _should_exit- _should_exit = True- if original_handler:- original_handler(sig_, frame) # type: ignore[unreachable]+ if not _should_exit:+ _should_exit = True+ listeners = list(_shutdown_listeners.values())+ for callable in listeners:+ try:+ callable()+ except Exception:+ logger.exception('Error calling shutdown listener')+ if original_handler:+ original_handler(sig_, frame) # type: ignore[unreachable]original_handler = signal.signal(sig, handler)@@ -71,3 +82,13 @@ async def async_sleep_if_should_continue(timeout: float):start_time = time.time()while time.time() - start_time < timeout and should_continue():await asyncio.sleep(1)+++def add_shutdown_listener(callable: Callable) -> UUID:+ id_ = uuid4()+ _shutdown_listeners[id_] = callable+ return id_+++def remove_shutdown_listener(id_: UUID) -> bool:+ return _shutdown_listeners.pop(id_, None) is not Nonediff --git a/tests/unit/test_shutdown_listener.py b/tests/unit/test_shutdown_listener.pynew file mode 100644index 0000000000..a4317c6b76--- /dev/null+++ b/tests/unit/test_shutdown_listener.py@@ -0,0 +1,116 @@+import signal+from dataclasses import dataclass, field+from signal import Signals+from typing import Callable+from unittest.mock import MagicMock, patch+from uuid import UUID++import pytest++from openhands.utils import shutdown_listener+from openhands.utils.shutdown_listener import (+ add_shutdown_listener,+ remove_shutdown_listener,+ should_continue,+)++[email protected](autouse=True)+def cleanup_listeners():+ shutdown_listener._shutdown_listeners.clear()+ shutdown_listener._should_exit = False+++@dataclass+class MockSignal:+ handlers: dict[Signals, Callable] = field(default_factory=dict)++ def signal(self, signalnum: Signals, handler: Callable):+ result = self.handlers.get(signalnum)+ self.handlers[signalnum] = handler+ return result++ def trigger(self, signalnum: Signals):+ handler = self.handlers.get(signalnum)+ if handler:+ handler(signalnum.value, None)+++def test_add_shutdown_listener():+ mock_callable = MagicMock()+ listener_id = add_shutdown_listener(mock_callable)++ assert isinstance(listener_id, UUID)+ assert listener_id in shutdown_listener._shutdown_listeners+ assert shutdown_listener._shutdown_listeners[listener_id] == mock_callable+++def test_remove_shutdown_listener():+ mock_callable = MagicMock()+ listener_id = add_shutdown_listener(mock_callable)++ # Test successful removal+ assert remove_shutdown_listener(listener_id) is True+ assert listener_id not in shutdown_listener._shutdown_listeners++ # Test removing non-existent listener+ assert remove_shutdown_listener(listener_id) is False+++def test_signal_handler_calls_listeners():+ mock_signal = MockSignal()+ with patch('openhands.utils.shutdown_listener.signal', mock_signal):+ mock_callable1 = MagicMock()+ mock_callable2 = MagicMock()+ add_shutdown_listener(mock_callable1)+ add_shutdown_listener(mock_callable2)++ # Register and trigger signal handler+ shutdown_listener._register_signal_handler(signal.SIGTERM)+ mock_signal.trigger(signal.SIGTERM)++ # Verify both listeners were called+ mock_callable1.assert_called_once()+ mock_callable2.assert_called_once()++ # Verify should_continue returns False after shutdown+ assert should_continue() is False+++def test_listeners_called_only_once():+ mock_signal = MockSignal()+ with patch('openhands.utils.shutdown_listener.signal', mock_signal):+ mock_callable = MagicMock()+ add_shutdown_listener(mock_callable)++ # Register and trigger signal handler multiple times+ shutdown_listener._register_signal_handler(signal.SIGTERM)+ mock_signal.trigger(signal.SIGTERM)+ mock_signal.trigger(signal.SIGTERM)++ # Verify listener was called only once+ assert mock_callable.call_count == 1+++def test_remove_listener_during_shutdown():+ mock_signal = MockSignal()+ with patch('openhands.utils.shutdown_listener.signal', mock_signal):+ mock_callable1 = MagicMock()+ mock_callable2 = MagicMock()++ # Second listener removes the first listener when called+ listener1_id = add_shutdown_listener(mock_callable1)++ def remove_other_listener():+ remove_shutdown_listener(listener1_id)+ mock_callable2()++ add_shutdown_listener(remove_other_listener)++ # Register and trigger signal handler+ shutdown_listener._register_signal_handler(signal.SIGTERM)+ mock_signal.trigger(signal.SIGTERM)++ # Both listeners should still be called+ assert mock_callable1.call_count == 1+ assert mock_callable2.call_count == 1