Free, open-source AI video generator for Mac. Run LTX-2.5 and MiniMax H3 (Hailuo) locally on Apple Silicon: text-to-video and image-to-video with sound, lip-sync, character LoRA training, songs from lyrics (YuE2) and image editing (Qwen-Image-Edit). One-click install via Pinokio. Offline: no cloud, no API key, no NVIDIA GPU.
Python ai-filmmakingai-videoai-video-generatorapple-siliconhailuoimage-to-videolip-synclocal-ailora-trainingltx-2ltx-2-5ltx-videomacosminimax-h3mlxmusic-generationoffline-aipinokiotext-to-videovideo-generation
fix(agent): browser-driven UX audit — orphan engines, status lies, layout bugs
mrbizarro351f60625be5
diff --git a/agent/image_engine.py b/agent/image_engine.pyindex f37dadc..e6699ec 100644--- a/agent/image_engine.py+++ b/agent/image_engine.py@@ -487,9 +487,10 @@ def _generate_mflux(prompt: str, n: int, width: int, height: int,# for a confusing argparse failure.if fam == "qwen_edit" and not refs:raise ValueError(- "qwen_edit requires at least 1 reference image. Either "- "switch the engine to 'qwen' (text-to-image, same model "- "family) or pass refs=[<path>] to compose against."+ "Qwen-Image-Edit-2509 needs at least 1 reference image — drop "+ "a photo into one of the 3 reference slots above, or switch "+ "the Engine dropdown to FLUX.2 [klein] / Z-Image-Turbo for "+ "text-only generation.")# Effective steps + guidance: prefer user-set values if non-zero,diff --git a/agent/local_server.py b/agent/local_server.pyindex 0376c04..d00d873 100644--- a/agent/local_server.py+++ b/agent/local_server.py@@ -34,13 +34,59 @@ _MODEL_PATH: str = ""_LAST_ERROR: str = ""+_LAST_REACHABLE_AT: float = 0.0+++def _port_reachable(port: int, timeout: float = 0.25) -> bool:+ """Cheap TCP-connect probe to see if the engine is actually serving.++ `_PROC.poll() is None` returns True for a few hundred ms after a+ failed bind (the process is alive long enough for the bind error+ to crash it). Without this probe the panel would tell the user the+ engine is "live" while requests time out. Cached for 750 ms so the+ polling status endpoint stays cheap.+ """+ import socket+ try:+ sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)+ sock.settimeout(timeout)+ try:+ sock.connect(("127.0.0.1", port))+ finally:+ sock.close()+ return True+ except OSError:+ return False++def status() -> dict:- """Snapshot for the UI: is the local engine running, and on what?"""- global _PROC+ """Snapshot for the UI: is the local engine running, and on what?++ Two booleans because they can disagree:+ - `running` — `_PROC` is alive (process-level, cheap)+ - `reachable` — port is bound and accepts TCP connect+ During the bind-collision window after panel restart, the new+ engine is `running=True` but `reachable=False` for the second or+ two until it crashes; the UI should treat the engine as healthy+ only when BOTH are true.+ """+ global _PROC, _LAST_REACHABLE_ATwith _LOCK:running = _PROC is not None and _PROC.poll() is None+ reachable = False+ if running:+ now = time.time()+ # Cache the probe for 750 ms so status() polls cheaply.+ if now - _LAST_REACHABLE_AT > 0.75:+ reachable = _port_reachable(_PORT)+ if reachable:+ _LAST_REACHABLE_AT = now+ else:+ # Recent successful probe — assume still good.+ reachable = Truereturn {"running": running,+ "reachable": reachable,"port": _PORT,"model_path": _MODEL_PATH,"pid": _PROC.pid if running else None,@@ -74,6 +120,21 @@ def start(model_path: str, *, venv_python: str, log_sink=None) -> dict:return _status_locked()_stop_locked(reason="model change")+ # Reap orphaned `mlx_lm.server` processes left behind by prior+ # panel sessions. mlx_lm.server is spawned with `start_new_session=True`+ # so when the panel exits without a clean shutdown, the engine+ # survives — and on next panel boot it still holds port 8200.+ # The new spawn would then fail with `[Errno 48] Address already+ # in use` and exit immediately, but `_PROC.poll()` returned None+ # for a few hundred ms before it died, so the panel's status pill+ # showed "live" while the engine was actually broken.+ # Symptom Salo hit: "live" pill + "Local unreachable" banner side+ # by side; agent submits return "engine error: Remote end closed+ # connection without response". Fix: scan for any python running+ # `mlx_lm.server` against our port BEFORE we try to spawn, and+ # SIGTERM them (escalating to SIGKILL on holdouts).+ _reap_orphan_servers(port=_PORT, log_sink=log_sink)+if not Path(venv_python).exists():_LAST_ERROR = f"venv python not found: {venv_python}"return _status_locked()@@ -149,6 +210,72 @@ def start(model_path: str, *, venv_python: str, log_sink=None) -> dict:return status()+def _reap_orphan_servers(*, port: int, log_sink=None) -> None:+ """SIGTERM any `mlx_lm.server` python processes pointing at our port.++ Survives panel restarts because mlx_lm.server is spawned with+ `start_new_session=True` (so the engine doesn't die when the panel+ process tree dies). Without this reap, a fresh panel boot collides+ with the surviving engine from the previous session. Best-effort+ only — failures are logged but don't abort the start path.+ """+ import shutil++ if not shutil.which("ps"):+ return # macOS edge case; ps should always be there+ try:+ out = subprocess.run(+ ["ps", "-ax", "-o", "pid=,command="],+ capture_output=True, text=True, timeout=5,+ )+ except (subprocess.SubprocessError, OSError):+ return+ if out.returncode != 0:+ return++ port_marker = f"--port {port}"+ needle = "mlx_lm.server"+ self_pid = os.getpid()+ targets: list[int] = []+ for raw in out.stdout.splitlines():+ if needle not in raw or port_marker not in raw:+ continue+ # Lines look like "12345 /path/to/python -m mlx_lm.server --port 8200 ..."+ try:+ pid_str = raw.strip().split(None, 1)[0]+ pid = int(pid_str)+ except (ValueError, IndexError):+ continue+ if pid == self_pid:+ continue+ targets.append(pid)++ if not targets:+ return++ msg = f"local_server: reaping {len(targets)} orphan engine(s) on port {port}: {targets}"+ if log_sink is not None:+ try: log_sink(msg)+ except Exception: pass # noqa: BLE001+ # First SIGTERM all of them, give the kernel a beat to release the+ # port, then SIGKILL anything that didn't exit. Without the wait,+ # the next bind would still race with port shutdown.+ for pid in targets:+ try:+ os.kill(pid, signal.SIGTERM)+ except OSError:+ pass+ time.sleep(1.5)+ for pid in targets:+ try:+ os.kill(pid, 0) # probe — raises if already dead+ os.kill(pid, signal.SIGKILL)+ except OSError:+ pass+ # Final settle so the kernel surrenders the port before our spawn.+ time.sleep(0.5)++def stop(reason: str = "manual stop") -> dict:with _LOCK:_stop_locked(reason)@@ -178,9 +305,14 @@ def _stop_locked(reason: str) -> None:def _status_locked() -> dict:+ # Note: this internal helper deliberately does NOT call _port_reachable —+ # callers from inside _LOCK don't need the probe (they're either+ # mid-spawn or mid-stop, neither of which has a stable port state).+ # The public status() is the only path that pays the probe cost.running = _PROC is not None and _PROC.poll() is Nonereturn {"running": running,+ "reachable": False, # internal helper — caller is mid-flux"port": _PORT,"model_path": _MODEL_PATH,"pid": _PROC.pid if running else None,diff --git a/mlx_ltx_panel.py b/mlx_ltx_panel.pyindex 6b2ab90..30c499b 100644--- a/mlx_ltx_panel.py+++ b/mlx_ltx_panel.py@@ -12661,7 +12661,7 @@ HTML = r"""<!doctype html><div style="display:grid;grid-template-columns:repeat(2,1fr);gap:12px"><div class="field"><label>Engine</label>- <select id="imgStudioEngine">+ <select id="imgStudioEngine" onchange="imgStudioUpdateValidity()"><option value="auto" selected>Auto (use Settings)</option><option value="qwen_edit_inline">Qwen-Image-Edit-2509 (multi-ref · 8-step Q4, ~1 min/image)</option><option value="qwen_edit_lightning_inline">Qwen-Image-Edit-2509 + Lightning (multi-ref · 4-step Q4, ~10-15 s/image)</option>@@ -13492,6 +13492,39 @@ const IMG_STUDIO = {busy: false,};+// Engine families that REQUIRE at least one reference image (mflux's+// qwen-edit CLI marks --image-paths as required; calling it without+// refs returns an argparse error after model load). The Studio engine+// override values map 1:1 to these check predicates. Used by+// imgStudioUpdateValidity() to gate the Generate button.+function imgStudioRequiresRefs(engineOverride) {+ return engineOverride === 'qwen_edit_inline'+ || engineOverride === 'qwen_edit_lightning_inline'+ || engineOverride === 'qwen_edit_high_inline';+}++function imgStudioUpdateValidity() {+ const btn = document.getElementById('imgStudioGenBtn');+ const eng = document.getElementById('imgStudioEngine');+ const status = document.getElementById('imgStudioStatus');+ if (!btn || !eng) return;+ const refsCount = IMG_STUDIO.refs.filter(r => r && r.path).length;+ const needsRefs = imgStudioRequiresRefs(eng.value);+ let invalidReason = '';+ if (needsRefs && refsCount === 0) {+ invalidReason = 'Pick at least 1 reference image (drop a file into one of the 3 slots above) — Qwen-Image-Edit composes against an image, it cannot run text-only. Use the Lightning preset only after picking a ref.';+ }+ // Don't override the busy state — imgStudioGenerate manages disabled+ // during in-flight gens.+ if (!IMG_STUDIO.busy) {+ btn.disabled = !!invalidReason;+ btn.title = invalidReason || 'Generate (Cmd/Ctrl+Enter)';+ if (status && !status.textContent.startsWith('Generating')) {+ status.textContent = invalidReason ? '⚠ ' + invalidReason : '';+ }+ }+}+// Reveal the mock-engine option only when the URL has ?debug=1.// Mock paints flat colored rectangles — useful for testing the UX// without spending GPU time, but a casual user picks it and gets@@ -13513,6 +13546,10 @@ const IMG_STUDIO = {// mode hides it. The pill row drives both flows.function openImageStudio() {setMode('image');+ // Re-evaluate Generate button state (engine + ref count) every time the+ // user enters Studio so they don't see a stale "ready" button when the+ // engine selection makes refs mandatory.+ imgStudioUpdateValidity();setTimeout(() => {const t = document.getElementById('imgStudioPrompt');if (t) {@@ -13572,6 +13609,7 @@ function imgStudioRenderSlot(idx) {slot.classList.remove('has-image');slot.innerHTML = `<div class="placeholder">Drop or click<br>ref ${idx + 1}</div>`;}+ imgStudioUpdateValidity();}function imgStudioClearRef(idx) {@@ -16739,9 +16777,17 @@ function workflowSwitch(name) {.forEach(b => b.classList.toggle('active', b.dataset.workflow === name));const manual = document.getElementById('genForm');const agent = document.getElementById('agentPane');+ const studio = document.getElementById('studioSection');// Set body data attribute so CSS can switch the layout (wider form-pane,// show agent-stage-pane on the right).document.body.setAttribute('data-workflow', name);+ // Studio is an inline pane inside form-pane — when leaving Manual it+ // must hide too, otherwise the user lands on Agentic Flows with the+ // Studio form overlapping the chat. Also reset currentMode to t2v so+ // a future Manual click returns to a sane default. Bug fix from the+ // browser-driven audit: switching tabs while Studio was active left+ // the chat inaccessible.+ if (studio) studio.classList.remove('show');if (name === 'agent') {if (manual) manual.style.display = 'none';if (agent) agent.hidden = false;@@ -16876,16 +16922,64 @@ function agentEngineBannerShow(j, opts) {detail = j.message || 'Will auto-start on first message.';actionLabel = 'Start engine';actionEl && (actionEl.onclick = function() {- // Reuse the existing one-click engine-start path.- fetch('/agent/local/start', {method: 'POST'})- .then(() => agentRefreshConfig())- .then(() => setTimeout(() => agentCheckEngine({forceShow: true}), 1500));+ // Reuse the existing one-click engine-start path. After the+ // POST returns we poll agentRefreshConfig + agentCheckEngine+ // every 2 s for up to 45 s — Gemma 12B 4-bit binds the port+ // ~10-15 s after spawn, longer if weights need to come off+ // disk. Without the poll, the pill stays "starting…" forever+ // because nothing triggers a refresh once port is bound.+ fetch('/agent/local/start', {method: 'POST'}).then(() => {+ let tries = 0;+ const maxTries = 22; // ~45 s budget+ const tick = () => {+ agentRefreshConfig().then(() => {+ const local = (window.AGENT.config || {}).local_server || {};+ const reachable = (typeof local.reachable === 'boolean')+ ? local.reachable : !!local.running;+ if (reachable || tries >= maxTries) {+ agentCheckEngine({forceShow: true});+ return;+ }+ tries += 1;+ setTimeout(tick, 2000);+ }).catch(() => {+ tries += 1;+ if (tries < maxTries) setTimeout(tick, 2000);+ });+ };+ // First tick immediately so the pill flips out of "click to start"+ // the moment the spawn reports running=true.+ setTimeout(tick, 500);+ });});} else {title = `${kindLabel} unreachable`;detail = j.message || 'Probe failed.';- actionLabel = 'Open Settings';- actionEl && (actionEl.onclick = function() { openAgentSettings(); });+ actionLabel = 'Restart engine';+ actionEl && (actionEl.onclick = function() {+ // Restart-engine action — for the most common cause of unreachable+ // (orphaned process holding the port). The local_server.start path+ // now reaps orphans before spawning, so this is a clean recovery.+ fetch('/agent/local/stop', {method: 'POST'}).then(() =>+ fetch('/agent/local/start', {method: 'POST'})+ ).then(() => {+ let tries = 0;+ const tick = () => {+ agentRefreshConfig().then(() => {+ const local = (window.AGENT.config || {}).local_server || {};+ const reachable = (typeof local.reachable === 'boolean')+ ? local.reachable : !!local.running;+ if (reachable || tries >= 22) {+ agentCheckEngine({forceShow: true});+ return;+ }+ tries += 1;+ setTimeout(tick, 2000);+ });+ };+ setTimeout(tick, 500);+ });+ });}if (titleEl) titleEl.textContent = title;@@ -16939,7 +17033,17 @@ async function agentRefreshConfig() {let live = false;let summary = '';if (eng.kind === 'phosphene_local') {- live = !!local.running;+ // The pill is green only when BOTH process is alive AND port+ // accepts connections. Without the reachable check, a freshly+ // crashed engine (bind error after orphan collision) still+ // shows green for ~1 s and the user submits a chat that 500s+ // with "Remote end closed connection without response".+ // `local.reachable` is `true | false`; older panels that don't+ // expose it default to !!local.running for backward compat.+ const reachableOk = (typeof local.reachable === 'boolean')+ ? local.reachable+ : !!local.running;+ live = !!local.running && reachableOk;const modelName = formatModelName(eng.model || '');// Look up the resident size from the discovered models so the user// sees "22 GB" inline next to the name — no surprise loads.@@ -16950,9 +17054,17 @@ async function agentRefreshConfig() {const hit = list.find(m => m.path === path);if (hit && hit.size_gb) sizeBit = ` · ${hit.size_gb.toFixed(1)} GB`;} catch (e) {}- summary = live- ? `${modelName || 'Local'}${sizeBit} · live`- : `${modelName || 'Local'}${sizeBit} · click to start`;+ // Three-state summary: live / starting / click-to-start. The+ // "starting" state appears the moment a spawn begins until the+ // port is bound (typically 5-15 s for Gemma 12B, longer on first+ // run if weights need to come off disk).+ if (local.running && !reachableOk) {+ summary = `${modelName || 'Local'}${sizeBit} · starting…`;+ } else if (live) {+ summary = `${modelName || 'Local'}${sizeBit} · live`;+ } else {+ summary = `${modelName || 'Local'}${sizeBit} · click to start`;+ }} else {const u = (eng.base_url || '').replace(/^https?:\/\//, '').replace(/\/v1$/, '');summary = `${eng.model || 'remote'} · ${u}`;