Last updated: 2026-05-23 Status: PARKED (not a current signal; reactivate only through a FEATURE_REQUESTS.md ledger entry). Last reviewed 2026-09-01. Status note: the automated proof floor listed below is landed; VC-0 through VC-8 remain unexecuted because no vCenter capability exists in LOCAL_CAPABILITIES.md (blocked record dated 2026-03-30). This matrix is the checklist to run if VMware support is reactivated; it is not a signal to do more non-live VMware work. Governance surfaces:

  • status.json.candidate_lanes.platform-admission-execution
  • docs/release-control/v6/internal/VMWARE_VCENTER_PHASE1_API_RUNTIME_SPEC.md
  • docs/release-control/v6/internal/VMWARE_VSPHERE_PHASE1_EXECUTION_PLAN.md
  • docs/release-control/v6/internal/VMWARE_VCENTER_PHASE1_ALERTS_AND_ASSISTANT_SPEC.md
  • docs/release-control/v6/internal/VMWARE_VCENTER_PHASE1_ONBOARDING_SPEC.md
  • docs/release-control/v6/internal/VMWARE_VCENTER_PHASE1_RESOURCE_PROJECTION_SPEC.md

Use this matrix as the live-proof runbook for the trust-critical boundary between:

  1. a planned VMware architecture
  2. an implemented VMware phase-1 floor that may be first-lab-ready
  3. an honest claim that VMware is actually supported in Pulse

This matrix does not replace repo-local tests. It exists because VMware can look correct in isolated API, poller, or UI work while still failing the real support floor on a live vCenter. It also defines when the non-live harness may honestly say first-lab-ready instead of collapsing all progress into the same not supported bucket.

Governing Policy

The locked VMware phase-1 rule is:

  1. vmware-vsphere is one first-class platform id
  2. vCenter is the only supported entry point in phase 1
  3. ingestion is api-backed
  4. ESXi hosts project as canonical agent
  5. VMs project as canonical vm
  6. datastores project as canonical storage
  7. alerts and assistant read may be supported
  8. recovery stays n/a
  9. assistant control stays read-only

Scope

In scope:

  1. shared platform-connections onboarding to vCenter
  2. saved-connection test and health summary behavior
  3. inventory projection for hosts, VMs, and datastores
  4. alarm, event, task, snapshot, and metrics/history visibility where the declared floor depends on them
  5. assistant read on canonical VMware-backed resources

Out of scope:

  1. direct ESXi
  2. unified-agent-required bootstrap
  3. physical-disk, system-container, or app-container support
  4. recovery-artifact or restore claims
  5. assistant or operator control for VMware actions

Environment Prerequisites

Before running this matrix, provide a real VMware environment with:

  1. one reachable vCenter
  2. one service account candidate for phase-1 read-first support
  3. at least one ESXi host
  4. at least one VM
  5. at least one datastore
  6. at least one recent event or task visible through vCenter history
  7. ideally one VM snapshot so snapshot-tree visibility can be proven

Record the non-secret capability metadata first in LOCAL_CAPABILITIES.md. If that record does not exist, the matrix is not runnable.

Proof Record Contract

Until a successful live proof exists, keep the current blocked record at:

docs/release-control/v6/internal/records/vmware-vcenter-phase1-proof-blocked-2026-03-30.md

When the first real environment is exercised successfully, replace that blocked state with a dated proof record at:

docs/release-control/v6/internal/records/vmware-vcenter-phase1-proof-<YYYY-MM-DD>.md

Use docs/release-control/v6/internal/VMWARE_VCENTER_PHASE1_PROOF_RECORD_TEMPLATE.md to capture both the LOCAL_CAPABILITIES.md entry shape and the successful proof record shape.

That dated record should summarize:

  1. the environment alias and LOCAL_CAPABILITIES.md entry used
  2. vCenter version and build information
  3. the exact privilege bundle used for the pass, including the privilege required for GET /api/vcenter/vm/{vm}/guest/local-filesystem (the guest filesystem read added for VC-8's operational metric surface)
  4. pass/fail notes for VC-0 through VC-8
  5. captured evidence for projection, alerts/history, Assistant read, and the new uptime / guest disk usage cells on the canonical workload table
  6. explicit confirmation that direct ESXi, recovery support, and control stayed out of scope

Automated Proof Floor

Before calling VMware supported, Pulse should have automated proof for at least:

  1. backend API contract coverage for /api/vmware/connections*
  2. saved-secret preservation and saved-connection retest behavior
  3. projection of VMware-backed agent, vm, and storage resources without provider-local top-level types
  4. alert and history mapping on the shared paths
  5. assistant read classification and capability exposure remaining read-only

If the automated floor is missing, the manual drill may inform implementation, but it must not be used as the sole basis for a support claim.

Current repo-local automated proof already covers part of the read-only boundary. The browser chat specs 38-vmware-ai-chat-mentions and 42-vmware-ai-chat-read-recovery were retired with the Assistant chat window on 2026-10-22; the Go proofs below still cover the backend chat path.

  1. internal/ai/chat/context_prefetch_additional_test.go proves VMware-backed guest mentions stay read-only in Assistant context summaries.
  2. internal/ai/chat/service_tooling_test.go and internal/ai/tools/control_resource_test.go prove shared Assistant/tool wording stays capability-gated instead of claiming blanket VM control.
  3. internal/api/route_inventory_test.go and tests/integration/tests/41-vmware-phase1-exclusion-integrity.spec.ts prove the shipped route and browser surface stay out of direct ESXi, recovery, and VMware admin-plane territory.

First-Lab-Ready Checkpoint

Pulse may classify VMware first-lab-ready before live proof only when all of these are true:

  1. the governed architecture is locked
  2. the bounded phase-1 floor is implemented on shared paths
  3. automated non-live proof covers shared onboarding, canonical projection, alerts/history, Assistant read, and exclusion integrity
  4. the remaining blockers to a support claim are live-only facts rather than missing shared product work

first-lab-ready means the next proper move is a real vCenter run. It does not mean VMware is supported, marketed, or admitted into the support matrix.

Current state as of 2026-03-31:

  1. VMware meets the governed first-lab-ready checkpoint.
  2. The next highest-value step is a real vCenter proof pass through VC-0 through VC-7.
  3. Repeating not supported without also reporting first-lab-ready is no longer an accurate description of implementation progress.

Scenario Matrix

ID Scenario Pass focus
VC-0 Capability registration Live vCenter environment is recorded in LOCAL_CAPABILITIES.md with safe metadata
VC-1 Draft connection test New vCenter draft validates through the shared setup path with clean failure classification
VC-2 Saved connection retest Stored credentials can be re-tested without forcing secret re-entry
VC-3 Inventory projection floor ESXi hosts, VMs, and datastores land as canonical agent, vm, and storage
VC-4 Storage and snapshot visibility Datastore state and snapshot-tree visibility appear without inflating recovery claims
VC-5 Alerts and history floor Shared alerts can surface VMware alarm and history context
VC-6 Assistant read floor Assistant can inspect canonical VMware-backed resources without VMware-specific tools
VC-7 Exclusion integrity No direct ESXi, recovery, or control claim leaks into the shipped behavior or wording
VC-8 Operational metric surface Host and VM uptime plus VM guest filesystem usage land on the canonical workload table for VMware-backed resources without silent gaps

Execution Steps

VC-0 Capability Registration

  1. Record the environment in LOCAL_CAPABILITIES.md with safe access notes, verification command, and any non-secret environment label.

Pass when:

  1. the capability is recorded
  2. a future agent can discover that a live VMware proof environment exists without reading secrets

VC-1 Draft Connection Test

  1. Open the shared Platform connections workspace.
  2. Create a new VMware draft with the phase-1 connection fields.
  3. Run the draft test path before saving.
  4. Intentionally exercise at least one bad-path case such as bad host, TLS mismatch, or insufficient privileges.

Pass when:

  1. the draft validates through the shared VMware setup path
  2. failures classify clearly instead of collapsing into generic unknown error, including tls, network, auth, permission, and unsupported_version where applicable
  3. the path does not require a unified agent or direct ESXi routing
  4. a green result reflects the declared phase-1 floor rather than one partial VMware API-family success

Automated non-live proof should continue to cover the shared browser path for unsupported_version, auth, tls, and network classifications so the first real lab run is not the first operator-visible exercise of those failure shapes.

VC-2 Saved Connection Retest

  1. Save a working VMware connection.
  2. Re-test it through the saved-connection test path.
  3. Re-test it again with a partial edit payload that preserves unchanged secrets.
  4. Reload the connection list.

Pass when:

  1. the saved-connection test succeeds without re-entering masked secrets
  2. edited saved-connection tests can reuse stored secrets server-side
  3. the list reflects refreshed last-success or last-error state
  4. the saved-connection contract still hides any dual-client runtime detail behind one connection health result

Automated non-live proof should continue to cover the shared settings shell for saved-connection auth/runtime failure classification and degraded permission guidance so the first real lab run does not discover those operator-facing states for the first time.

VC-3 Inventory Projection Floor

  1. Let the VMware poller collect from the saved connection.
  2. Inspect the infrastructure/workload/storage surfaces or canonical APIs.
  3. Compare the observed resources against the governed projection spec.
  4. Confirm hosts, VMs, and datastores are visible.

Pass when:

  1. ESXi hosts land as canonical agent
  2. guest workloads land as canonical vm
  3. datastores land as canonical storage
  4. no provider-local top-level esxi-host, vsphere-vm, or equivalent type appears
  5. topology metadata stays metadata and does not appear as synthetic top-level VMware resource types

VC-4 Storage And Snapshot Visibility

  1. Inspect datastore state through the shared storage surface.
  2. Inspect VM detail for snapshot-tree visibility.
  3. Confirm any recovery-adjacent wording stays descriptive, not product-claim inflation.

Pass when:

  1. datastore capacity, free space, and accessibility are visible on the shared path
  2. snapshot-tree visibility exists when the upstream environment exposes it
  3. Pulse does not present VMware as recovery-supported just because snapshots are readable

VC-5 Alerts And History Floor

  1. Inspect shared alerts or incident views after VMware collection.
  2. Confirm VMware-backed alarm or health context can be reached.
  3. Confirm related event/task context is available where the shared product expects it.
  4. Confirm topology-scoped alarm context does not appear as a VMware-only incident resource.

Pass when:

  1. alerts route through shared alert and incident surfaces
  2. VMware-backed context is readable there without a provider-local shell
  3. the product does not imply VMware-specific alarm management
  4. event and task context lands on shared incident or resource-timeline paths, not a VMware-only history surface

VC-6 Assistant Read Floor

  1. Use the shared Assistant read paths against canonical VMware-backed resources.
  2. Inspect a host, a VM, and a datastore.
  3. Confirm shared tool exposure stays read-only.

Pass when:

  1. Assistant reads work on canonical agent, vm, and storage
  2. there are no VMware-specific tools or verbs required
  3. no control capability or VMware-specific action metadata is exposed as part of the VMware phase-1 floor

Current automated coverage (the browser chat specs 38-vmware-ai-chat-mentions and 42-vmware-ai-chat-read-recovery were retired with the Assistant chat window on 2026-10-22; the Go proofs below still cover the backend chat path):

  1. internal/ai/chat/context_prefetch_additional_test.go
  2. internal/ai/chat/service_tooling_test.go
  3. internal/ai/tools/control_resource_test.go

VC-7 Exclusion Integrity

  1. Review shipped wording, route inventory, tool inventory, and visible product behavior.
  2. Confirm no broader support claim leaked in while implementing the floor.

Pass when:

  1. direct ESXi is still out of scope
  2. recovery support is still n/a
  3. assistant control is still read-only
  4. no VMware admin-plane action surface shipped by implication

Current automated coverage:

  1. internal/api/route_inventory_test.go
  2. tests/integration/tests/41-vmware-phase1-exclusion-integrity.spec.ts
  3. internal/ai/tools/tools_query_test.go
  4. internal/ai/tools/control_resource_test.go

VC-8 Operational Metric Surface

Phase-1's resource projection (VC-3) and storage/snapshot visibility (VC-4) prove that VMware-backed entities land as canonical types and that datastore + snapshot context is readable. They do not, by themselves, prove that the operational columns the canonical workload table renders for every other platform — host uptime, VM uptime, VM guest filesystem usage — actually populate against a real vCenter. This scenario locks that gap explicitly so it cannot slip behind the existing projection pass.

The new code paths under proof here are:

  1. PerformanceManager counter additions in internal/vmware/client_metrics.go: sys.uptime.latest for hosts and VMs, and sys.osUptime.latest for VMs. The mapping prefers guest OS uptime (Tools-reported) and falls back to VMX-process uptime when the guest counter is absent.
  2. New per-VM REST collector in internal/vmware/client_topology.go: GET /api/vcenter/vm/{vm}/guest/local-filesystem, aggregated across mount points into InventoryMetrics.DiskTotalBytes / DiskUsedBytes / DiskPercent and projected onto canonical ResourceMetrics.Disk.
  3. Canonical projection in internal/vmware/provider.go: UptimeSeconds lands on Resource.Uptime for hosts and VMs; the disk fields land on metrics.disk so the shared workload table renders the same shape every other platform uses.

Steps:

  1. Confirm the candidate vCenter service account can read PerformanceManager.perfCounter and successfully query sys.uptime.latest against a sample host and VM.
  2. Confirm the same account can issue GET /api/vcenter/vm/{vm}/guest/local-filesystem against a powered-on VM with VMware Tools running, and that the response decodes as map[string]VmGuestLocalFilesystemInfo (each entry carrying capacity and free_space).
  3. Open the vSphere overview page; confirm a powered-on VM row renders a real "N days" Uptime cell and a non-empty DISK column with both percent and human-readable bytes.
  4. Confirm a powered-off VM, a VM with VMware Tools stopped, and a VM the service account is not permitted to read for guest operations each surface their gap correctly: Uptime / DISK stay blank (not "0" or "0 B / 0 B") and the snapshot's enrichment-issues array records a non-fatal unavailable (Tools missing) or permission (insufficient privilege) entry rather than failing the entire poll.
  5. Confirm sys.osUptime.latest is collected when the vCenter is configured at statistics level 4 (real-time interval), and that the fallback to sys.uptime.latest engages cleanly when the level-4 counter is not exposed.

Pass when:

  1. Host and VM Resource.Uptime populate against the live vCenter for any powered-on entity that vCenter would normally surface uptime for.
  2. metrics.disk on a powered-on VM with Tools running carries a non-zero Total and a Percent derived from real guest filesystem reads, with at least one realistic mount point present.
  3. The shared workload table renders these on the vSphere overview without the operator having to toggle the Columns menu.
  4. Missing-data cases (Tools stopped, VM powered off, privilege gap) flow through the existing non-fatal enrichment-issue path with an actionable category (unavailable for Tools, permission for privilege) rather than failing the whole poll.
  5. The exact privilege required for GET /api/vcenter/vm/{vm}/guest/local-filesystem is captured in the dated proof record so the documented "minimum privilege bundle" can be tightened from "guessed" to "verified."

Current automated coverage:

  1. internal/vmware/client_test.go's degraded-enrichment test exercises the new endpoint's happy path (multi-mount filesystem response) and the unavailableVMGuestInfo Tools-not-running 503 path.
  2. internal/mock/platform_fixtures_test.go asserts the synthesized uptime + guest disk values flow through the canonical projection for powered-on VMs and drop cleanly for powered-off VMs.
  3. frontend-modern/src/hooks/__tests__/useWorkloads.test.ts asserts the Resource.Uptime fallback so vSphere uptime lands on WorkloadGuest.uptime despite vSphere not populating a platform-specific carve-out.

Open unknown (track in the dated proof record):

The exact vCenter privilege required for the guest local-filesystem read. Public documentation does not pin this down, and Pulse's existing "minimum privilege bundle" entry in VMWARE_VCENTER_PHASE1_ONBOARDING_SPEC.md already names privilege verification as a live-environment unknown. The first real VC-8 pass should capture the exact privilege name so subsequent customer setup docs can ship it explicitly.

Evidence To Capture

Capture all of the following outside git or in the dated release-control record:

  1. the LOCAL_CAPABILITIES.md capability entry
  2. vCenter version/build information
  3. the exact privilege bundle used for the successful proof run
  4. connection-list screenshots or payloads showing poll health and observed contribution summary
  5. canonical resource screenshots or payloads showing agent, vm, and storage projection
  6. alert or incident screenshots/payloads showing VMware-backed context
  7. assistant read transcript or screenshots showing canonical VMware-backed resource inspection
  8. explicit note that recovery and control stayed out of scope

The expected success-record path is:

docs/release-control/v6/internal/records/vmware-vcenter-phase1-proof-<YYYY-MM-DD>.md

Use the companion template:

docs/release-control/v6/internal/VMWARE_VCENTER_PHASE1_PROOF_RECORD_TEMPLATE.md

Failure Rules

Do not call VMware supported if any of these are true:

  1. no live vCenter capability is recorded
  2. the privilege bundle is guessed rather than proven
  3. the supported version floor is guessed rather than proven
  4. VMware inventory lands on provider-local top-level resource types
  5. the product wording or runtime behavior implies direct ESXi support
  6. the product wording or runtime behavior implies recovery support
  7. the product wording or runtime behavior exposes VMware control as part of phase 1

Current Blocker

As of 2026-03-30, VC-0 is not yet satisfied in this workspace. There is still no recorded VMware capability in /Volumes/Development/pulse/LOCAL_CAPABILITIES.md.

That means the planning and implementation path can continue, but the support claim remains blocked until a real proof environment is available.

Current blocked record:

docs/release-control/v6/internal/records/vmware-vcenter-phase1-proof-blocked-2026-03-30.md