VMware vCenter Phase-1 Resource Projection Spec

Last updated: 2026-05-22 Status: IMPLEMENTED (canonical projection shipped: unifiedresources.SourceVMware fed by internal/monitoring/vmware_poller.go and internal/vmware/client_topology.go, network inventory added in 5016cbc2ba; vmware-vsphere is admitted at first-lab-ready in PLATFORM_SUPPORT_MANIFEST.json; live vCenter projection proof is still outstanding). Last reviewed 2026-09-01. Governance surfaces:

  • status.json.candidate_lanes.platform-admission-execution
  • docs/release-control/v6/internal/VMWARE_VSPHERE_PHASE1_EXECUTION_PLAN.md
  • docs/release-control/v6/internal/VMWARE_VCENTER_PHASE1_PROOF_MATRIX.md

Intent

This document locks the canonical phase-1 projection contract for vmware-vsphere.

It exists to answer one architecture question before runtime work starts: what exactly from vCenter becomes a shared Pulse resource, what stays topology-only metadata, and what must not be projected at all in phase 1.

Governing Rule

Phase-1 VMware support is only valid if all of these stay true:

  1. vCenter is the only supported phase-1 entry point
  2. ingestion is api-backed
  3. ESXi hosts project as canonical agent
  4. virtual machines project as canonical vm
  5. datastores project as canonical storage
  6. vCenter networks project as canonical network
  7. datacenter, cluster, cluster HA/DRS service state, folder, resource pool, and vCenter itself remain topology or relationship metadata, not top-level Pulse resources
  8. physical-disk, system-container, app-container, and recovery artifacts remain out of phase 1

Canonical Source Contract

When runtime work starts, Pulse should add one canonical VMware-backed source classification alongside the existing shared source enums.

That means:

  1. one shared VMware source key, expected to land as vmware / SourceVMware, not separate vcenter and esxi source families
  2. platformType should be vmware-vsphere on projected VMware-backed canonical resources
  3. vCenter is the connection authority, not a top-level unified resource
  4. the saved connection or discovered vCenter identity should scope every VMware provider identifier so bare managed-object IDs do not masquerade as workspace-global identities

The last point is an implementation inference from the official APIs: the docs describe host, VM, and datastore identifiers as resource-type identifiers, but they do not claim those identifiers are globally unique across multiple distinct vCenter environments.

Projection Table

VMware object class Canonical Pulse type Phase-1 floor Top-level? Notes
HostSystem / ESXi host agent yes yes host inventory, runtime state, health, metrics/history
VirtualMachine vm yes yes workload inventory, runtime state, guest identity when available, snapshot-tree visibility
Datastore storage yes yes inventory, capacity/free-space, accessibility, relationships
Network network yes yes inventory, type, placement, host attachments, VM attachments, health signals
vCenter none no no connection and poll authority only
Datacenter none metadata only no placement and topology context
ClusterComputeResource none metadata only no placement, grouping, HA/DRS service context
Folder none metadata only no inventory placement context
ResourcePool none metadata only no workload placement context
snapshot tree none read-side VM detail only no not a recovery artifact
alarm definitions / triggered alarms alerts / incident context yes n/a routed through shared alert and timeline surfaces
events / tasks resource timeline / incident context yes n/a supporting context, not new resource types

ESXi Host To agent

What the APIs clearly support:

  1. the vCenter host summary surface exposes a host identifier, name, connection state, power state, and in newer API versions host_uuid
  2. VI JSON host runtime exposes connection state, power state, maintenance mode, and health runtime state
  3. VI JSON host summaries expose overall alarm status plus storage and CPU status summaries

Phase-1 projection rule:

  1. one ESXi host from vCenter becomes one canonical agent
  2. the provider-scoped host identifier is the VMware-side primary identity for that resource inside the VMware source
  3. the canonical agent display identity should come from the host name, not from cluster or datacenter labels
  4. cluster, datacenter, folder, and resource-pool context stay in VMware-specific platform metadata or relationships under that canonical agent
  5. when GET /api/vcenter/cluster exposes HA/DRS service state for the resolved cluster, that state may be copied onto the host's vmware facet as read-only monitoring context, not as a cluster resource or host control capability

Required secondary identity capture when available:

  1. host_uuid
  2. hostname / DNS name
  3. IP addresses when the chosen collection path can read them cleanly
  4. any future shared agent-augmentation identity fields only through the canonical cross-source merge path, not through a VMware-only dedupe model

Validation note:

The official Vcenter Host Summary schema adds host_uuid in vSphere API 9.0.0.0. Older supported floors may therefore need fallback identity anchors from VI JSON host properties. That cross-version identity floor must be proven before a support claim is made.

Virtual Machine To vm

What the APIs clearly support:

  1. GET /api/vcenter/vm returns VM identifier, name, power state, CPU count, and memory size
  2. GET /api/vcenter/vm/{vm} returns optional identity.bios_uuid and identity.instance_uuid
  3. GET /api/vcenter/vm/{vm}/guest/identity returns guest OS family, guest hostname, and IP address when VMware Tools is running and has data
  4. VI JSON VirtualMachine.snapshot returns the current snapshot and snapshot tree when snapshots exist

Phase-1 projection rule:

  1. one VMware virtual machine becomes one canonical vm
  2. the provider-scoped VM identifier is the VMware-side primary identity for that resource inside the VMware source
  3. instance_uuid and bios_uuid should be captured as secondary identities whenever present because they are the cleanest future bridge to cross-source merge or assistant reasoning
  4. guest hostname and guest IP are optional enrichments, not identity requirements, because the guest-identity API can fail when VMware Tools is absent or not reporting
  5. host placement, folder placement, resource-pool membership, and datastore attachments stay as relationships or platform metadata under the canonical vm
  6. when GET /api/vcenter/cluster exposes HA/DRS service state for the resolved cluster, that state may be copied onto the VM's vmware facet as read-only placement context, not as VM identity, scheduling authority, or recovery posture

Snapshot boundary:

  1. snapshot tree is valid phase-1 workload detail
  2. snapshot presence may feed timeline or investigation context
  3. snapshot data must not be promoted into shared recovery artifacts, restore points, or recovery-supported product wording

Datastore To storage

What the APIs clearly support:

  1. GET /api/vcenter/datastore returns datastore identifier, name, type, free-space, and capacity
  2. VI JSON DatastoreSummary exposes accessible, multipleHostAccess, maintenanceMode, capacity, freeSpace, and url

Phase-1 projection rule:

  1. one datastore becomes one canonical storage
  2. the provider-scoped datastore identifier is the VMware-side primary identity for that resource inside the VMware source
  3. display identity should come from datastore name
  4. datastore type, accessibility, maintenance mode, and multi-host access are part of the shared storage-facing truth when the upstream environment exposes them
  5. host attachments and VM usage stay as relationships under canonical storage, not as new top-level VMware objects

Validation note:

Datastore inventory and headline capacity are clearly supported from the official APIs. Exact phase-1 extraction of host mounts and VM-to-datastore usage needs live validation so Pulse does not promise more placement fidelity than the chosen collection path can actually deliver.

vCenter Network To network

What the APIs clearly support:

  1. GET /api/vcenter/network returns network identifier, name, and type
  2. VI JSON vim.Network exposes inventory placement through parent, attached hosts through host, and attached VMs through vm
  3. VI JSON managed-entity signal paths can expose overall status, alarms, recent tasks, and recent events for network objects when the vCenter account has permission

Phase-1 projection rule:

  1. one vCenter network becomes one canonical network
  2. the provider-scoped network identifier is the VMware-side primary identity for that resource inside the VMware source
  3. network type, datacenter/folder placement, host attachments, and VM attachments belong under the shared vmware facet for read-side monitoring
  4. network rows are descriptive topology and health inventory; phase 1 must not introduce switch, portgroup, distributed-switch, or network-control resource types
  5. network telemetry/history remains out of scope unless a later governed slice proves a shared network metrics contract

Topology And Relationship Rules

These VMware concepts remain metadata or relationships in phase 1:

  1. vCenter
  2. datacenter
  3. cluster
  4. folder
  5. resource pool
  6. datastore cluster / storage pod

Cluster HA and DRS flags are properties of the cluster placement context. They may be rendered on canonical hosts and VMs whose placement resolves to that cluster, but the cluster itself remains topology metadata in phase 1.

That means phase-1 VMware work must not add:

  1. esxi-host
  2. vsphere-vm
  3. vsphere-datastore
  4. vsphere-network
  5. vsphere-cluster
  6. vsphere-datacenter
  7. vsphere-resource-pool

If a future slice wants one of those to become top-level, it needs a separate governed admission decision because it would expand the shared Pulse resource model, not just the VMware adapter.

Alerts, Incidents, And Timeline

What the APIs clearly support:

  1. VI JSON AlarmManager.GetAlarm retrieves alarms defined on a managed entity
  2. VI JSON host summaries expose overallStatus
  3. VI JSON event and task paths exist for related operational context

Phase-1 alert rule:

  1. VMware alarm and health signals may surface only through the shared alert and incident model
  2. alert-backed investigation must attach to canonical agent, vm, storage, or network resources
  3. cluster-, datacenter-, or folder-scoped VMware alarm context may inform the incident, but it must not create synthetic top-level VMware incident resources in phase 1
  4. event and task context belongs in the shared resource timeline or incident context, not in a VMware-only history surface
  5. direct VMware alarm acknowledgement, reset, or editing is out of scope

Telemetry And History

What the APIs clearly support:

  1. VI JSON PerformanceManager.QueryPerfComposite returns composite metrics for a host and its first-level child entities and is explicitly documented for host-plus-VM usage
  2. VM runtime and hardware detail are available through the vCenter VM APIs
  3. datastore free-space and capacity state are available from the datastore inventory APIs

Phase-1 telemetry rule:

  1. ESXi host telemetry must land on the shared agent metrics/history path
  2. VM telemetry must land on the shared vm metrics/history path
  3. datastore state or capacity-history signals must land on the shared storage path
  4. vCenter network inventory may land on the shared network resource path, but phase 1 does not claim network metrics/history
  5. phase-1 VMware work must not create a vmware-host, vmware-vm, vmware-datastore, or vmware-network history store

Validation note:

QueryPerfComposite is clearly documented for host-plus-child collection, but it is not by itself proof of complete standalone VM history parity across the whole supported floor. Exact counter coverage, retention shape, and any required per-VM follow-up queries must be proven on the live support floor before the product makes a broad telemetry/history claim.

Explicit Phase-1 Non-Projections

Phase 1 must not project any of the following into shared top-level Pulse resource types:

  1. physical-disk
  2. system-container
  3. app-container
  4. recovery artifact
  5. restore point
  6. backup job
  7. direct ESXi standalone system

That exclusion remains in force even though VMware exposes richer APIs in some of those areas.

Discovery Gaps That Still Matter

The architecture is stable, but these points still require live proof:

  1. exact cross-version identity floor for ESXi hosts when host_uuid is not available from the chosen supported version
  2. exact relationship extraction path for VM-to-datastore usage, network-to-host attachment, network-to-VM attachment, and datastore-to-host mount fidelity
  3. exact alarm-to-canonical-resource attachment rule for cluster- or datacenter-scoped alarms
  4. exact performance/history counter set that is strong enough for the shared Pulse history surfaces without inventing VMware-only paths

If those proofs fail, the support claim must narrow or stop. The runtime must not compensate by inventing provider-local resource types or sidecar products.

Primary Source Basis

  1. host inventory summary: Vcenter Host Summary
  2. host runtime and health: HostRuntimeInfo
  3. host overall alarm and status summaries: HostListSummary
  4. VM inventory: Vcenter VM list
  5. VM identity detail: Vcenter VM get
  6. guest identity detail: Vcenter Vm Guest Identity get
  7. datastore inventory: Vcenter Datastore list
  8. datastore accessibility and storage summary: DatastoreSummary
  9. VM snapshot tree: Virtual Machine Get Snapshot
  10. managed-entity alarms: Alarm Manager Get Alarm
  11. host-plus-child performance: Performance Manager Query Perf Composite
  12. cluster inventory and HA/DRS service state: Vcenter Cluster list
  13. network inventory: Vcenter Network list
  14. network placement and attachments: vim.Network