Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
{
"version": 1,
"base_sha": "3ca8b9647ab992101adf9153b71b5ef1757ac82f",
"verified_at": "2026-10-06T19:34:00Z",
"result": "passed",
"changed_paths": [
"frontend-modern/src/features/alerts/AlertOverviewAlertCard.tsx",
"frontend-modern/src/features/alerts/AlertResourceIncidentsPanel.tsx",
"frontend-modern/src/features/alerts/metricAlertPresentation.ts",
"frontend-modern/src/features/alerts/useAlertHistoryState.ts"
],
"content_sha256": {
"frontend-modern/src/features/alerts/AlertOverviewAlertCard.tsx": "bae52439900c395e8c7d33f87296e6c3d4f449e15fcf1dc69a0137111025d0ab",
"frontend-modern/src/features/alerts/AlertResourceIncidentsPanel.tsx": "6c8347cb65f80520711f9f4b66b2c46e09c51121bf67e9ec382bce67ca3468a6",
"frontend-modern/src/features/alerts/metricAlertPresentation.ts": "1b7314213d79cdfbad9f84b854ae8652802ad6c2d51955586c175475a024dbee",
"frontend-modern/src/features/alerts/useAlertHistoryState.ts": "5b9f10978f2d2d7101f92343e826bef9ae5e2677b36ccf431ff0e6dfa9d676a8"
},
"routes": [
"/alerts/overview",
"/alerts/history",
"/patrol"
],
"viewports": [
{
"width": 1280,
"height": 900
},
{
"width": 1024,
"height": 607
},
{
"width": 768,
"height": 1024
},
{
"width": 375,
"height": 812
}
],
"states": [
"Private mock stack (sidecar build, uncommitted generator overlay pinning pve2 CPU temperature; alert level 80\u00b0C, clear level 75\u00b0C, 5 minute recovery delay)",
"Alerts overview card, breaching at 95\u00b0C: \"Temperature 95\u00b0C, above the 80\u00b0C alert level\", clear rule detail, \"Alert level 80\u00b0C\" and \"Clear level 75\u00b0C\"",
"Alerts overview card, held at 78\u00b0C: \"Temperature 78\u00b0C now, back under the 80\u00b0C alert level\" with hover \"Last reading at or above 80\u00b0C: 95\u00b0C\"; message \"Node temperature at 95.0\u00b0C\" no longer shown",
"Alerts overview card, recovering at 72\u00b0C: \"Temperature 72\u00b0C now, recovering\" and \"Clears after 5 minutes at 75\u00b0C or lower, 2 minutes so far.\" at 1280px and 375px (no horizontal scroll)",
"Fahrenheit preference: held card reads \"Temperature 172\u00b0F now, back under the 176\u00b0F alert level\", \"Alert level 176\u00b0F\", \"Clear level 167\u00b0F\", hover \"Last reading at or above 176\u00b0F: 203\u00b0F\"",
"Mail Gateway queue-age card keeps its message and no longer shows a guessed \"30%\" level; breaching memory card shows \"Memory 85%, above the 85% alert level\" with its levels",
"Card layout at 1024px: text column 256px with actions wrapped to two rows (was 110-160px beside one row); a 66-character resource name truncates with no overflow; 1280px unchanged (one row of actions); 768px text 256px, no overflow; 375px stacked, no horizontal scroll",
"Card removed after the alert resolved",
"History resource incidents panel: the open occurrence whose id and start match the live alert shows the live summary with the breach on hover; a cached open occurrence with an earlier start and closed occurrences keep their recorded messages (incident list extended in-page because mock mode never records open occurrences)",
"Patrol inbox row for pve2 shows the held summary from plainLanguageSummary; API shows recovering summary, breaching pve3 keeps its message, resolved pve2 keeps \"Resolved: Node temperature at 72.0\u00b0C\""
],
"interactions": [
"Walked pve2 temperature 95 -> 78 -> 72 via the control file and reloaded the overview between phases; repeated 95 -> 78 after the final rebuild",
"Read card text and hover titles in each phase",
"Switched the temperature unit to Fahrenheit (localStorage temperatureUnit) and reloaded",
"Measured card column widths and overflow at 1280, 1024, 768 and 375 px, with a long resource name substituted in the DOM",
"Opened the pve2 Resource incidents panel from the History table row and pressed Refresh",
"Opened Patrol inbox and read the pve2 row"
]
}