Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
{
"version": 1,
"base_sha": "8259a74c9d0503df630b09c12a2c1be906fa3d78",
"verified_at": "2026-10-06T22:20:00Z",
"result": "passed",
"changed_paths": [
"frontend-modern/src/features/storageBackups/diskPresentation.ts"
],
"content_sha256": {
"frontend-modern/src/features/storageBackups/diskPresentation.ts": "87469b0d62a31a1657a94a5f645041ad34987cc5af55ca238c6cbf49b0c068ee"
},
"routes": [
"/proxmox/storage?tab=disks",
"/proxmox/storage?tab=disks&status=attention",
"/proxmox/storage?tab=disks&status=critical",
"/proxmox/storage?tab=disks&status=warning"
],
"viewports": [
{
"width": 1440,
"height": 900
},
{
"width": 390,
"height": 844
}
],
"states": [
"Private mock stack (8 nodes) whose generator was overlaid locally, never committed, to pin readings from a control file on pve3: Crucial MX500 2TB /dev/nvme2 (SMART PASSED) at 72C, WD Blue SN570 /dev/sd1 at 63C, and Crucial MX500 2TB /dev/nvme0 at 72C with 2 pending sectors. The API returned risk {critical: [temperature_high]}, {warning: [temperature_high]} and {critical: [pending_sectors, temperature_high]} respectively; the backend binary was rebuilt from base 8259a74c9d (includes #2611)",
"Same-session control with the pre-change diskPresentation.ts (3ac5664d95, whose verdict code is unchanged on base 8259a74c9d) swapped in under the running Vite: the 72C temperature-only disk read 'Replace Now' (phone 'Replace') titled 'Disk temperature is 72C' in the row and in its drawer, and the 63C disk read 'Needs Attention' and sorted above the 7%-life disk",
"After the change at 1440 (full layout): rows sort Replace Now (pending sectors, title 'Pending sectors detected (2)', rgb(185,28,28)), Running Hot (title 'Disk temperature is 72C', rgb(185,28,28)), Needs Attention (970 EVO, 'SSD life remaining is 7%', rgb(180,83,9)), Running Hot (title 'Disk temperature is 63C', rgb(180,83,9)), then Healthy/Unknown disks unchanged",
"After the change at 390 (narrow layout): the same rows show the compact words Replace, Hot, Attention, Hot with the same tones and titles",
"Disk drawer header for the 72C temperature-only disk reads 'Running Hot Disk temperature is 72C' at both widths",
"Health filter from the URL at both widths: status=attention lists the two Replace/Hot critical rows plus Attention and the amber Hot row; status=critical lists only Replace Now and the red Running Hot; status=warning lists Needs Attention and the amber Running Hot",
"Known and unchanged: the 63C NVMe reads Running Hot in amber beside a green Temp cell, because the risk tier is the server's flat 60C while the Temp cell uses the NVMe alert threshold; the same disk read Needs Attention before this change. Threshold reconciliation is separate work",
"Amended content (empty-summary reasons keep their code and severity, an unexplained critical level no longer borrows a weaker reason's text): full pass repeated at 1440 and 390 with identical rows, compact words, titles, colours, drawer header and status=attention/critical/warning results"
],
"interactions": [
"Loaded the Physical Disks tab unfiltered at 1440x900 and 390x844 and read every row's visible health word, its title, computed colour and the Temp cell",
"Opened the inline drawer for the 72C temperature-only disk by clicking its row at both widths and read the health header",
"Loaded status=attention, status=critical and status=warning at both widths and read the listed rows",
"Swapped the pre-change diskPresentation.ts in under the running Vite, repeated the reads, restored the change and confirmed it byte-identical with cmp; after rebasing onto 8259a74c9d repeated the full after-change pass with a rebuilt backend"
]
}