Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
package alerts
import (
"fmt"
"strings"
"time"
alertspecs "github.com/rcourtman/pulse-go-rewrite/internal/alerts/specs"
"github.com/rcourtman/pulse-go-rewrite/internal/storagehealth"
"github.com/rcourtman/pulse-go-rewrite/internal/unifiedresources"
"github.com/rcourtman/pulse-go-rewrite/pkg/proxmox"
"github.com/rs/zerolog/log"
)
func proxmoxDiskCanonicalResourceID(instance, node, devPath string) string {
return unifiedresources.ProxmoxPhysicalDiskAlertResourceID(instance, node, devPath)
}
// proxmoxDiskAlertMetadata records the evaluated disk's hardware identity
// with each alert. The alert reference names only the device path, so
// resource history owns each lifecycle row by this serial or WWN.
func proxmoxDiskAlertMetadata(disk proxmox.Disk) map[string]interface{} {
return map[string]interface{}{
"disk_path": disk.DevPath,
"disk_model": disk.Model,
unifiedresources.MetadataDiskSerial: disk.Serial,
unifiedresources.MetadataDiskWWN: disk.WWN,
"disk_type": disk.Type,
"disk_size": disk.Size,
}
}
// proxmoxDiskWearoutThreshold is the percent life remaining at or below
// which a Proxmox SSD raises a wearout alert.
const proxmoxDiskWearoutThreshold = 10
// CheckDiskHealth checks disk health and creates alerts if needed
func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {
// Create unique alert ID for this disk
alertID := fmt.Sprintf("disk-health-%s-%s-%s", instance, node, disk.DevPath)
wearoutAlertID := fmt.Sprintf("disk-wearout-%s-%s-%s", instance, node, disk.DevPath)
resourceID := fmt.Sprintf("%s-%s", node, disk.DevPath)
resourceName := fmt.Sprintf("%s (%s)", disk.Model, disk.DevPath)
canonicalResourceID := proxmoxDiskCanonicalResourceID(instance, node, disk.DevPath)
resourceType := unifiedresources.ResourceType("proxmox-disk")
canonicalHealthAlertID := buildCanonicalStateID(canonicalResourceID, canonicalResourceID+"-health")
clearDiskAlert := func(ids ...string) {
seen := make(map[string]struct{}, len(ids))
for _, id := range ids {
if id == "" {
continue
}
if _, exists := seen[id]; exists {
continue
}
seen[id] = struct{}{}
m.clearAlert(id)
}
}
// Check if disk health is not PASSED
normalizedHealth := strings.ToUpper(strings.TrimSpace(disk.Health))
healthCheckNeeded := normalizedHealth != "" && normalizedHealth != "UNKNOWN" && normalizedHealth != "PASSED" && normalizedHealth != "OK"
// Skip health alerts for drives with known firmware bugs that cause false reports
// These drives may report FAILED status due to firmware issues even when healthy
// We still monitor wearout below, which is more reliable for these drives
if healthCheckNeeded && storagehealth.HasKnownFirmwareBug(disk.Model) {
log.Debug().
Str("node", node).
Str("disk", disk.DevPath).
Str("model", disk.Model).
Str("health", disk.Health).
Msg("Skipping health alert for drive with known firmware bug - health status unreliable")
// Clear any existing health alert since we now recognize this is a false positive.
// Older installs may still have the legacy alert key persisted on disk.
clearDiskAlert(alertID, canonicalHealthAlertID)
healthCheckNeeded = false // Skip to wearout check
}
if healthCheckNeeded {
spec, err := buildCanonicalHealthAssessmentSpec(canonicalResourceID+"-health", canonicalResourceID, resourceName, resourceType, "proxmox-disk-health", nil, false)
if err != nil {
log.Warn().
Err(err).
Str("node", node).
Str("disk", disk.DevPath).
Msg("Skipping invalid canonical proxmox disk health spec")
} else {
metadata := proxmoxDiskAlertMetadata(disk)
metadata["disk_health"] = disk.Health
result, _ := m.evaluateCanonicalStatefulAlert(canonicalStatefulAlertParams{
Spec: spec,
Evidence: alertspecs.AlertEvidence{
ObservedAt: time.Now(),
HealthAssessment: &alertspecs.HealthAssessmentEvidence{
Signal: "proxmox-disk-health",
Severity: alertspecs.AlertSeverityCritical,
Codes: []string{normalizedHealth},
},
},
AlertID: alertID,
AlertType: "disk-health",
ResourceID: resourceID,
ResourceName: resourceName,
Node: node,
Instance: instance,
Message: fmt.Sprintf("Disk health check failed: %s", disk.Health),
Metadata: metadata,
AddToRecent: true,
AddToHistory: true,
})
// Every disk poll re-evaluates a failed disk, so log at error
// only when the alert opens, not on each poll after it.
if diskAlertOpened(result) {
log.Error().
Str("node", node).
Str("disk", disk.DevPath).
Str("model", disk.Model).
Str("health", disk.Health).
Msg("Disk health alert created")
} else {
log.Debug().
Str("node", node).
Str("disk", disk.DevPath).
Str("health", disk.Health).
Msg("Disk health check still failing")
}
}
} else {
// Disk is healthy, clear alert if it exists
clearDiskAlert(alertID, canonicalHealthAlertID)
}
// Check wearout only when the disk reports endurance. Unknown readings
// cannot prove recovery; 0 from an SSD is a real, fully spent reading,
// whereas -1 and rotational 0 are absent evidence.
if storagehealth.WearoutReported(disk.Wearout, disk.Type) {
// Wearout is percent life remaining, not percent worn, so the
// message names it as life remaining, in the host-agent SMART
// wording. The threshold travels in the alert's Threshold field.
message := fmt.Sprintf("SSD life remaining is %d%%", disk.Wearout)
spec, err := buildCanonicalSeverityThresholdSpecWithDirection(canonicalResourceID+"-wearout", canonicalResourceID, resourceName, resourceType, "wearout-remaining", alertspecs.ThresholdDirectionBelow, proxmoxDiskWearoutThreshold, 0, false)
if err != nil {
log.Warn().
Err(err).
Str("node", node).
Str("disk", disk.DevPath).
Msg("Skipping invalid canonical proxmox disk wearout spec")
} else {
metadata := proxmoxDiskAlertMetadata(disk)
metadata["disk_wearout"] = disk.Wearout
result, _ := m.evaluateCanonicalStatefulAlert(canonicalStatefulAlertParams{
Spec: spec,
// Endurance cannot normally improve on the same disk. Require
// sustained healthy-looking polls before resolving a worn-disk
// occurrence; a new low reading resets the recovery run (#2112).
RecoveryConfirmations: 3,
Evidence: alertspecs.AlertEvidence{
ObservedAt: time.Now(),
SeverityThreshold: &alertspecs.SeverityThresholdEvidence{
Metric: "wearout-remaining",
Direction: alertspecs.ThresholdDirectionBelow,
Observed: float64(disk.Wearout),
},
},
AlertID: wearoutAlertID,
AlertType: "disk-wearout",
ResourceID: resourceID,
ResourceName: resourceName,
Node: node,
Instance: instance,
Message: message,
Value: float64(disk.Wearout),
Threshold: proxmoxDiskWearoutThreshold,
Metadata: metadata,
AddToRecent: true,
AddToHistory: true,
})
if diskAlertOpened(result) {
log.Warn().
Str("node", node).
Str("disk", disk.DevPath).
Str("model", disk.Model).
Int("lifeRemaining", disk.Wearout).
Msg("Disk wearout alert created")
} else if disk.Wearout <= proxmoxDiskWearoutThreshold {
log.Debug().
Str("node", node).
Str("disk", disk.DevPath).
Int("lifeRemaining", disk.Wearout).
Msg("Disk life remaining still at or below wearout threshold")
}
}
}
}
// diskAlertOpened reports whether this evaluation opened the alert, as
// opposed to re-evaluating one that is already active, pending, or
// suppressed.
func diskAlertOpened(result alertspecs.EvaluationResult) bool {
return result.Transition != nil && result.Transition.Kind == alertspecs.EvaluationTransitionActivated
}