package alerts

import (
	"fmt"
	"strings"
	"time"

	alertspecs "github.com/rcourtman/pulse-go-rewrite/internal/alerts/specs"
	"github.com/rcourtman/pulse-go-rewrite/internal/storagehealth"
	"github.com/rcourtman/pulse-go-rewrite/internal/unifiedresources"
	"github.com/rcourtman/pulse-go-rewrite/pkg/proxmox"
	"github.com/rs/zerolog/log"
)

func proxmoxDiskCanonicalResourceID(instance, node, devPath string) string {
	return unifiedresources.ProxmoxPhysicalDiskAlertResourceID(instance, node, devPath)
}

// proxmoxDiskAlertMetadata records the evaluated disk's hardware identity
// with each alert. The alert reference names only the device path, so
// resource history owns each lifecycle row by this serial or WWN.
func proxmoxDiskAlertMetadata(disk proxmox.Disk) map[string]interface{} {
	return map[string]interface{}{
		"disk_path":                         disk.DevPath,
		"disk_model":                        disk.Model,
		unifiedresources.MetadataDiskSerial: disk.Serial,
		unifiedresources.MetadataDiskWWN:    disk.WWN,
		"disk_type":                         disk.Type,
		"disk_size":                         disk.Size,
	}
}

// proxmoxDiskWearoutThreshold is the percent life remaining at or below
// which a Proxmox SSD raises a wearout alert.
const proxmoxDiskWearoutThreshold = 10

// CheckDiskHealth checks disk health and creates alerts if needed
func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {
	// Create unique alert ID for this disk
	alertID := fmt.Sprintf("disk-health-%s-%s-%s", instance, node, disk.DevPath)
	wearoutAlertID := fmt.Sprintf("disk-wearout-%s-%s-%s", instance, node, disk.DevPath)
	resourceID := fmt.Sprintf("%s-%s", node, disk.DevPath)
	resourceName := fmt.Sprintf("%s (%s)", disk.Model, disk.DevPath)
	canonicalResourceID := proxmoxDiskCanonicalResourceID(instance, node, disk.DevPath)
	resourceType := unifiedresources.ResourceType("proxmox-disk")
	canonicalHealthAlertID := buildCanonicalStateID(canonicalResourceID, canonicalResourceID+"-health")

	clearDiskAlert := func(ids ...string) {
		seen := make(map[string]struct{}, len(ids))
		for _, id := range ids {
			if id == "" {
				continue
			}
			if _, exists := seen[id]; exists {
				continue
			}
			seen[id] = struct{}{}
			m.clearAlert(id)
		}
	}

	// Check if disk health is not PASSED
	normalizedHealth := strings.ToUpper(strings.TrimSpace(disk.Health))
	healthCheckNeeded := normalizedHealth != "" && normalizedHealth != "UNKNOWN" && normalizedHealth != "PASSED" && normalizedHealth != "OK"

	// Skip health alerts for drives with known firmware bugs that cause false reports
	// These drives may report FAILED status due to firmware issues even when healthy
	// We still monitor wearout below, which is more reliable for these drives
	if healthCheckNeeded && storagehealth.HasKnownFirmwareBug(disk.Model) {
		log.Debug().
			Str("node", node).
			Str("disk", disk.DevPath).
			Str("model", disk.Model).
			Str("health", disk.Health).
			Msg("Skipping health alert for drive with known firmware bug - health status unreliable")

		// Clear any existing health alert since we now recognize this is a false positive.
		// Older installs may still have the legacy alert key persisted on disk.
		clearDiskAlert(alertID, canonicalHealthAlertID)
		healthCheckNeeded = false // Skip to wearout check
	}

	if healthCheckNeeded {
		spec, err := buildCanonicalHealthAssessmentSpec(canonicalResourceID+"-health", canonicalResourceID, resourceName, resourceType, "proxmox-disk-health", nil, false)
		if err != nil {
			log.Warn().
				Err(err).
				Str("node", node).
				Str("disk", disk.DevPath).
				Msg("Skipping invalid canonical proxmox disk health spec")
		} else {
			metadata := proxmoxDiskAlertMetadata(disk)
			metadata["disk_health"] = disk.Health

			result, _ := m.evaluateCanonicalStatefulAlert(canonicalStatefulAlertParams{
				Spec: spec,
				Evidence: alertspecs.AlertEvidence{
					ObservedAt: time.Now(),
					HealthAssessment: &alertspecs.HealthAssessmentEvidence{
						Signal:   "proxmox-disk-health",
						Severity: alertspecs.AlertSeverityCritical,
						Codes:    []string{normalizedHealth},
					},
				},
				AlertID:      alertID,
				AlertType:    "disk-health",
				ResourceID:   resourceID,
				ResourceName: resourceName,
				Node:         node,
				Instance:     instance,
				Message:      fmt.Sprintf("Disk health check failed: %s", disk.Health),
				Metadata:     metadata,
				AddToRecent:  true,
				AddToHistory: true,
			})

			// Every disk poll re-evaluates a failed disk, so log at error
			// only when the alert opens, not on each poll after it.
			if diskAlertOpened(result) {
				log.Error().
					Str("node", node).
					Str("disk", disk.DevPath).
					Str("model", disk.Model).
					Str("health", disk.Health).
					Msg("Disk health alert created")
			} else {
				log.Debug().
					Str("node", node).
					Str("disk", disk.DevPath).
					Str("health", disk.Health).
					Msg("Disk health check still failing")
			}
		}
	} else {
		// Disk is healthy, clear alert if it exists
		clearDiskAlert(alertID, canonicalHealthAlertID)
	}

	// Check wearout only when the disk reports endurance. Unknown readings
	// cannot prove recovery; 0 from an SSD is a real, fully spent reading,
	// whereas -1 and rotational 0 are absent evidence.
	if storagehealth.WearoutReported(disk.Wearout, disk.Type) {
		// Wearout is percent life remaining, not percent worn, so the
		// message names it as life remaining, in the host-agent SMART
		// wording. The threshold travels in the alert's Threshold field.
		message := fmt.Sprintf("SSD life remaining is %d%%", disk.Wearout)
		spec, err := buildCanonicalSeverityThresholdSpecWithDirection(canonicalResourceID+"-wearout", canonicalResourceID, resourceName, resourceType, "wearout-remaining", alertspecs.ThresholdDirectionBelow, proxmoxDiskWearoutThreshold, 0, false)
		if err != nil {
			log.Warn().
				Err(err).
				Str("node", node).
				Str("disk", disk.DevPath).
				Msg("Skipping invalid canonical proxmox disk wearout spec")
		} else {
			metadata := proxmoxDiskAlertMetadata(disk)
			metadata["disk_wearout"] = disk.Wearout

			result, _ := m.evaluateCanonicalStatefulAlert(canonicalStatefulAlertParams{
				Spec: spec,
				// Endurance cannot normally improve on the same disk. Require
				// sustained healthy-looking polls before resolving a worn-disk
				// occurrence; a new low reading resets the recovery run (#2112).
				RecoveryConfirmations: 3,
				Evidence: alertspecs.AlertEvidence{
					ObservedAt: time.Now(),
					SeverityThreshold: &alertspecs.SeverityThresholdEvidence{
						Metric:    "wearout-remaining",
						Direction: alertspecs.ThresholdDirectionBelow,
						Observed:  float64(disk.Wearout),
					},
				},
				AlertID:      wearoutAlertID,
				AlertType:    "disk-wearout",
				ResourceID:   resourceID,
				ResourceName: resourceName,
				Node:         node,
				Instance:     instance,
				Message:      message,
				Value:        float64(disk.Wearout),
				Threshold:    proxmoxDiskWearoutThreshold,
				Metadata:     metadata,
				AddToRecent:  true,
				AddToHistory: true,
			})

			if diskAlertOpened(result) {
				log.Warn().
					Str("node", node).
					Str("disk", disk.DevPath).
					Str("model", disk.Model).
					Int("lifeRemaining", disk.Wearout).
					Msg("Disk wearout alert created")
			} else if disk.Wearout <= proxmoxDiskWearoutThreshold {
				log.Debug().
					Str("node", node).
					Str("disk", disk.DevPath).
					Int("lifeRemaining", disk.Wearout).
					Msg("Disk life remaining still at or below wearout threshold")
			}
		}
	}
}

// diskAlertOpened reports whether this evaluation opened the alert, as
// opposed to re-evaluating one that is already active, pending, or
// suppressed.
func diskAlertOpened(result alertspecs.EvaluationResult) bool {