Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
package unifiedresources
import (
"testing"
"time"
"github.com/rcourtman/pulse-go-rewrite/internal/models"
)
func TestIssue1516SeededControllerMembersKeepStableSourceIDsAcrossRestart(t *testing.T) {
parentID := "host-canonical"
seeded := []Resource{
{
ID: parentID,
Type: ResourceTypeAgent,
Name: "pve-wide",
Sources: []DataSource{SourceAgent},
Agent: &AgentData{AgentID: "host-1", Hostname: "pve-wide"},
},
{
ID: "disk-member-1",
Type: ResourceTypePhysicalDisk,
Name: "member-1",
ParentID: &parentID,
Sources: []DataSource{SourceAgent},
PhysicalDisk: &PhysicalDiskMeta{
DevPath: "/dev/sg2",
Controller: "sssraid0",
Target: "sssraid,0,1",
Wearout: -1,
},
},
{
ID: "disk-member-2",
Type: ResourceTypePhysicalDisk,
Name: "member-2",
ParentID: &parentID,
Sources: []DataSource{SourceAgent},
PhysicalDisk: &PhysicalDiskMeta{
DevPath: "/dev/sg2",
Controller: "sssraid0",
Target: "sssraid,0,2",
Wearout: -1,
},
},
}
restarted := NewRegistry(nil)
restarted.IngestResources(seeded)
seededIDByTarget := make(map[string]string)
for _, disk := range restarted.ListByType(ResourceTypePhysicalDisk) {
if disk.PhysicalDisk != nil {
seededIDByTarget[disk.PhysicalDisk.Target] = disk.ID
}
}
for _, test := range []struct {
sourceID string
target string
}{
{"host-1:sg2@sssraid0/sssraid,0,1", "sssraid,0,1"},
{"host-1:sg2@sssraid0/sssraid,0,2", "sssraid,0,2"},
} {
got := restarted.ingest(
SourceAgent,
test.sourceID,
Resource{
Type: ResourceTypePhysicalDisk,
Name: test.target,
ParentID: &parentID,
PhysicalDisk: &PhysicalDiskMeta{
DevPath: "/dev/sg2",
Controller: "sssraid0",
Target: test.target,
Wearout: -1,
},
},
ResourceIdentity{Hostnames: []string{"pve-wide"}},
)
if want := seededIDByTarget[test.target]; want == "" || got != want {
t.Fatalf("restart source %q resolved to %q, want seeded ID %q", test.sourceID, got, want)
}
}
if got := len(restarted.ListByType(ResourceTypePhysicalDisk)); got != 2 {
t.Fatalf("controller members collapsed or duplicated after restart: got %d disks", got)
}
}
func TestIssue1516AgentSMARTAndPVEInventoryMergeWithoutContradictingEvidence(t *testing.T) {
registry := NewRegistry(nil)
now := time.Date(2026, 7, 23, 12, 0, 0, 0, time.UTC)
used := 95
zero := int64(0)
identity := ResourceIdentity{
MachineID: "NVME-BOOT-1",
Hostnames: []string{"pve-a"},
}
agentID := registry.ingest(
SourceAgent,
"host-1:nvme0n1",
Resource{
Type: ResourceTypePhysicalDisk,
Name: "NVMe boot disk",
Status: StatusWarning,
LastSeen: now,
PhysicalDisk: &PhysicalDiskMeta{
DevPath: "/dev/nvme0n1",
Model: "Samsung 990 PRO",
Serial: "NVME-BOOT-1",
DiskType: "nvme",
Health: "FAILED",
Wearout: 5,
Temperature: 44,
SMART: &SMARTMeta{
PercentageUsed: &used,
ReallocatedSectors: &zero,
},
},
},
identity,
)
pveID := registry.ingest(
SourceProxmox,
"cluster-a-pve-a--dev-nvme0n1",
Resource{
Type: ResourceTypePhysicalDisk,
Name: "Samsung 990 PRO",
Status: StatusOnline,
LastSeen: now,
Proxmox: &ProxmoxData{
Instance: "cluster-a",
NodeName: "pve-a",
},
PhysicalDisk: &PhysicalDiskMeta{
DevPath: "/dev/nvme0n1",
Model: "Samsung 990 PRO",
Vendor: "Samsung",
Serial: "NVME-BOOT-1",
DiskType: "ssd",
SizeBytes: 2_000_398_934_016,
Health: "PASSED",
Wearout: 100,
Used: "BIOS boot",
},
},
identity,
)
if pveID != agentID {
t.Fatalf("agent and PVE views did not merge: agent=%q pve=%q", agentID, pveID)
}
disks := registry.ListByType(ResourceTypePhysicalDisk)
if len(disks) != 1 || disks[0].PhysicalDisk == nil {
t.Fatalf("expected one merged physical disk, got %+v", disks)
}
disk := disks[0]
if disk.Proxmox == nil || disk.Proxmox.Instance != "cluster-a" || disk.Proxmox.NodeName != "pve-a" {
t.Fatalf("PVE node/instance facet was lost: %+v", disk.Proxmox)
}
if disk.PhysicalDisk.SizeBytes != 2_000_398_934_016 ||
disk.PhysicalDisk.Vendor != "Samsung" ||
disk.PhysicalDisk.Used != "BIOS boot" {
t.Fatalf("PVE-only boot/size fields were lost: %+v", disk.PhysicalDisk)
}
if disk.PhysicalDisk.Health != "FAILED" ||
disk.PhysicalDisk.Wearout != 5 ||
disk.PhysicalDisk.Temperature != 44 {
t.Fatalf("coarse PVE values replaced SMART evidence: %+v", disk.PhysicalDisk)
}
if disk.PhysicalDisk.SMART == nil ||
disk.PhysicalDisk.SMART.ReallocatedSectors == nil ||
*disk.PhysicalDisk.SMART.ReallocatedSectors != 0 {
t.Fatalf("reported zero SMART evidence was lost: %+v", disk.PhysicalDisk.SMART)
}
}
func TestIssue1516ProxmoxSourceIDsSeparateNodesAndControllerMembers(t *testing.T) {
nodeA := ProxmoxPhysicalDiskSourceID("cluster-a", "pve-a", "/dev/sda", "", "")
nodeB := ProxmoxPhysicalDiskSourceID("cluster-a", "pve-b", "/dev/sda", "", "")
member1 := ProxmoxPhysicalDiskSourceID("cluster-a", "pve-a", "/dev/sg2", "sssraid0", "sssraid,0,1")
member2 := ProxmoxPhysicalDiskSourceID("cluster-a", "pve-a", "/dev/sg2", "sssraid0", "sssraid,0,2")
for _, pair := range [][2]string{
{nodeA, nodeB},
{member1, member2},
{nodeA, member1},
} {
if pair[0] == pair[1] {
t.Fatalf("distinct physical disks shared source ID %q", pair[0])
}
}
}
func TestIssue1516RepeatedSerialAcrossNodesDoesNotCrossAttachMetrics(t *testing.T) {
registry := NewRegistry(nil)
for _, node := range []string{"pve-a", "pve-b"} {
registry.ingest(
SourceProxmox,
ProxmoxPhysicalDiskSourceID("cluster-a", node, "/dev/sda", "", ""),
Resource{
Type: ResourceTypePhysicalDisk,
Name: node + "-disk",
PhysicalDisk: &PhysicalDiskMeta{
DevPath: "/dev/sda",
Serial: "DEFAULT-SERIAL",
DiskType: "sata",
Temperature: map[string]int{"pve-a": 31, "pve-b": 47}[node],
Wearout: -1,
},
},
ResourceIdentity{
Hostnames: []string{node},
},
)
}
disks := registry.ListByType(ResourceTypePhysicalDisk)
if len(disks) != 2 {
t.Fatalf("same placeholder serial on different nodes collapsed to %d resource(s): %+v", len(disks), disks)
}
temperatureByHost := make(map[string]int)
for _, disk := range disks {
if disk.PhysicalDisk == nil || len(disk.Identity.Hostnames) != 1 {
t.Fatalf("unexpected disk projection: %+v", disk)
}
temperatureByHost[disk.Identity.Hostnames[0]] = disk.PhysicalDisk.Temperature
}
if temperatureByHost["pve-a"] != 31 || temperatureByHost["pve-b"] != 47 {
t.Fatalf("disk metrics crossed node boundaries: %+v", temperatureByHost)
}
metricA := PhysicalDiskMetricID(models.PhysicalDisk{
ID: ProxmoxPhysicalDiskSourceID("cluster-a", "pve-a", "/dev/sda", "", ""),
Instance: "cluster-a",
Node: "pve-a",
DevPath: "/dev/sda",
Serial: "DEFAULT-SERIAL",
})
metricB := PhysicalDiskMetricID(models.PhysicalDisk{
ID: ProxmoxPhysicalDiskSourceID("cluster-a", "pve-b", "/dev/sda", "", ""),
Instance: "cluster-a",
Node: "pve-b",
DevPath: "/dev/sda",
Serial: "DEFAULT-SERIAL",
})
if metricA == "" || metricB == "" || metricA == metricB {
t.Fatalf("placeholder serial shared metric key: pve-a=%q pve-b=%q", metricA, metricB)
}
}