Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
fix(alerts): Prevent RAID check/scrub from triggering rebuild alerts. Related to #1125
rcourtman0248f0de5a9e
diff --git a/internal/alerts/alerts.go b/internal/alerts/alerts.goindex bff2f59d8d..e17bc63201 100644--- a/internal/alerts/alerts.go+++ b/internal/alerts/alerts.go@@ -2941,9 +2941,13 @@ func (m *Manager) CheckHost(host models.Host) {// Check for degraded or failed arraysstateLower := strings.ToLower(array.State)isDegraded := strings.Contains(stateLower, "degraded") || array.FailedDevices > 0- isRebuilding := strings.Contains(stateLower, "recover") ||++ // A "check" state indicates data scrubbing (e.g., DSM scheduled scrub), not a rebuild.+ // Only treat as rebuilding if state indicates actual recovery, not routine maintenance.+ isChecking := strings.Contains(stateLower, "check")+ isRebuilding := !isChecking && (strings.Contains(stateLower, "recover") ||strings.Contains(stateLower, "resync") ||- array.RebuildPercent > 0+ (array.RebuildPercent > 0 && !strings.Contains(stateLower, "clean")))alertID := fmt.Sprintf("host-%s-raid-%s", host.ID, sanitizeRAIDDevice(array.Device))