Skip to content

armgit / Pulse

Public Imported from GitHub
0

Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.

Key previous Proxmox nodes by source ID so poll carry-overs match

rcourtman0c130a4855e4
diff --git a/docs/release-control/v6/internal/subsystems/monitoring.md b/docs/release-control/v6/internal/subsystems/monitoring.md
index 40873c0536..ba87140d89 100644
--- a/docs/release-control/v6/internal/subsystems/monitoring.md
+++ b/docs/release-control/v6/internal/subsystems/monitoring.md
@@ -3772,7 +3772,39 @@ cluster sensor cache, which keeps its own recency check. When every source
returns nothing, `internal/monitoring/monitor_polling_node_helpers.go` may carry
a previous reading, with its original `LastUpdate`, only inside the carry window
(twice the PVE polling interval, never under five minutes); an older reading is
-dropped rather than re-presented as current.
+dropped rather than re-presented as current. A carried reading also keeps a
+lapsed host agent's lease. Agent readings are stamped with the agent's report
+time, so `carriedTemperatureOutlivesAgentLease` drops a carried reading stamped
+no later than the last report of the node's matched agent (by link, then
+hostname, whether or not that report had sensors) once that agent has lapsed.
+Readings record no source, so the bound is conservative: an SSH, cluster-cache
+or agent-plus-SSH merged reading (stamped with the agent's time) of that age is
+dropped too, being already older than the lease, while a reading stamped after
+that report keeps the carry window. A carried reading (`carriedNodeTemperature`)
+keeps only the node's CPU and GPU temperatures: its SMART and NVMe rows would
+also stamp the node's physical disks, whose freshness and standby state a
+carried copy cannot follow (a disk that spun down would be stamped and recorded
+with its pre-sleep value), so they are left out, and nothing is carried when
+only they remain.
+The poller reads its previous poll's nodes back from the unified read state
+through `internal/monitoring/monitor_previous_state.go`. `nodeLastOnline` and
+the temperature carry with its CPU low/record tracking match them by node ID,
+which is the Proxmox source ID, so the projection must return
+`NodeView.SourceID()`, never the unified resource ID, and carry the stored
+`TemperatureDetails`. Nodes preserved through an instance outage
+(`preserveOrExpireNodes`) or authoritative membership reconciliation are written
+back into state from that projection, so it also restores the identity inputs
+the registry derives a node's canonical ID and cross-view merges from: cluster
+name, provider-scoped flag, native aliases, TLS fingerprint and linked agent ID,
+the config-derived ones stamped the way `pollPVENode` stamps them. With the
+unified ID a node re-keys on every failed poll, and without its cluster
+identity a cluster member changes canonical ID for the length of an outage.
+A preserved node keeps its
+temperature only under the same carry rules and loses it when it goes
+offline. Node memory carry-over after a failed status read uses the poller's own
+validated `NodeMemorySnapshot`, not the read state, which holds the agent's
+reading on a node merged with a host agent, and keeps used, cache and free
+summing to the total.
Legacy SSH temperature collection must also use the Pulse sensor-wrapper
contract before falling back to raw lm-sensors output. `internal/monitoring/temperature.go`
must request `/usr/local/sbin/pulse-sensors` when it exists, parse the wrapper
diff --git a/internal/monitoring/host_agent_temps.go b/internal/monitoring/host_agent_temps.go
index 661caeaf6e..8b3fc4d3e0 100644
--- a/internal/monitoring/host_agent_temps.go
+++ b/internal/monitoring/host_agent_temps.go
@@ -86,44 +86,7 @@ func (m *Monitor) getHostAgentTemperatureByID(nodeID, nodeName string) *models.T
return nil
}
- hosts := readState.Hosts()
- if len(hosts) == 0 {
- // No host agents at all — check cluster sensor cache as fallback
- return m.getClusterSensorTemperature(nodeName)
- }
-
- var matchedHost *unifiedresources.HostView
-
- // First, try to find a host agent that is explicitly linked to this node
- // via LinkedNodeID. This is the most reliable method and handles duplicate
- // hostnames correctly.
- if nodeID != "" {
- for i := range hosts {
- if hosts[i].LinkedNodeID() == nodeID {
- matchedHost = hosts[i]
- log.Debug().
- Str("nodeID", nodeID).
- Str("hostAgentID", hosts[i].ID()).
- Str("hostname", hosts[i].Hostname()).
- Msg("Matched host agent to node via LinkedNodeID")
- break
- }
- }
- }
-
- // Fallback: match by hostname if no linked host was found
- // This maintains backwards compatibility for setups where linking hasn't occurred yet
- if matchedHost == nil {
- nodeLower := strings.ToLower(strings.TrimSpace(nodeName))
- for i := range hosts {
- hostnameLower := strings.ToLower(strings.TrimSpace(hosts[i].Hostname()))
- if hostnameLower == nodeLower {
- matchedHost = hosts[i]
- break
- }
- }
- }
-
+ matchedHost := hostAgentForNode(readState.Hosts(), nodeID, nodeName)
if matchedHost == nil {
// No directly-linked host agent found — check cluster sensor cache
return m.getClusterSensorTemperature(nodeName)
@@ -153,6 +116,68 @@ func (m *Monitor) getHostAgentTemperatureByID(nodeID, nodeName string) *models.T
return convertUnifiedHostSensorsToTemperature(sensors, agentStatus.LastSeen)
}
+// carriedTemperatureOutlivesAgentLease reports whether a temperature a node
+// carries over from an earlier poll may have come from the node's host agent
+// after that agent stopped reporting. Agent readings are stamped with the
+// agent's report time and only count inside its reporting lease, so a reading
+// stamped no later than a lapsed agent's last report is treated as the agent's
+// and is not carried. Readings carry no source, so an SSH or cluster-cache
+// reading of that age is dropped too; it is already older than the lease, and
+// the bound errs toward a gap rather than a stale value. A reading stamped
+// after that report keeps the ordinary carry window.
+func (m *Monitor) carriedTemperatureOutlivesAgentLease(nodeID, nodeName string, temp *models.Temperature, now time.Time) bool {
+ if temp == nil {
+ return false
+ }
+ readState := m.GetUnifiedReadStateOrSnapshot()
+ if readState == nil {
+ return false
+ }
+ matchedHost := hostAgentForNode(readState.Hosts(), nodeID, nodeName)
+ if matchedHost == nil {
+ return false
+ }
+ agentStatus, ok := matchedHost.SourceStatus(unifiedresources.SourceAgent)
+ if !ok || agentStatus.LastSeen.IsZero() ||
+ hostAgentReportCurrent(agentStatus.LastSeen, matchedHost.IntervalSeconds(), now) {
+ return false
+ }
+ return !temp.LastUpdate.After(agentStatus.LastSeen)
+}
+
+// hostAgentForNode returns the host agent for a Proxmox node: the agent linked
+// to the node ID, else one whose hostname matches. This correctly handles
+// clusters where multiple nodes may have the same hostname (e.g., "px1" on
+// different IPs).
+func hostAgentForNode(hosts []*unifiedresources.HostView, nodeID, nodeName string) *unifiedresources.HostView {
+ // First, try to find a host agent that is explicitly linked to this node
+ // via LinkedNodeID. This is the most reliable method and handles duplicate
+ // hostnames correctly.
+ if nodeID != "" {
+ for i := range hosts {
+ if hosts[i].LinkedNodeID() == nodeID {
+ log.Debug().
+ Str("nodeID", nodeID).
+ Str("hostAgentID", hosts[i].ID()).
+ Str("hostname", hosts[i].Hostname()).
+ Msg("Matched host agent to node via LinkedNodeID")
+ return hosts[i]
+ }
+ }
+ }
+
+ // Fallback: match by hostname if no linked host was found
+ // This maintains backwards compatibility for setups where linking hasn't occurred yet
+ nodeLower := strings.ToLower(strings.TrimSpace(nodeName))
+ for i := range hosts {
+ hostnameLower := strings.ToLower(strings.TrimSpace(hosts[i].Hostname()))
+ if hostnameLower == nodeLower {
+ return hosts[i]
+ }
+ }
+ return nil
+}
+
func convertUnifiedHostSensorsToTemperature(sensors *unifiedresources.HostSensorMeta, lastSeen time.Time) *models.Temperature {
if sensors == nil {
return nil
diff --git a/internal/monitoring/memory_trust_characterization_test.go b/internal/monitoring/memory_trust_characterization_test.go
index 60c583c3a1..366164e81d 100644
--- a/internal/monitoring/memory_trust_characterization_test.go
+++ b/internal/monitoring/memory_trust_characterization_test.go
@@ -203,7 +203,7 @@ func TestPollPVENodeMemoryTrustCharacterization(t *testing.T) {
MaxCPU: 8,
}
- modelNode, _, _, err := mon.pollPVENode(context.Background(), "test", &mon.config.PVEInstances[0], client, node, "healthy", nil, nil)
+ modelNode, _, _, err := mon.pollPVENode(context.Background(), "test", &mon.config.PVEInstances[0], client, node, "healthy", nil)
if err != nil {
t.Fatalf("pollPVENode() error = %v", err)
}
@@ -258,7 +258,7 @@ func TestPollPVENodePreservesPreviousSnapshotDuringTransientFallback(t *testing.
MaxCPU: 8,
}
- first, _, _, err := mon.pollPVENode(context.Background(), "test", &mon.config.PVEInstances[0], client, node, "healthy", nil, nil)
+ first, _, _, err := mon.pollPVENode(context.Background(), "test", &mon.config.PVEInstances[0], client, node, "healthy", nil)
if err != nil {
t.Fatalf("first pollPVENode() error = %v", err)
}
@@ -274,7 +274,6 @@ func TestPollPVENodePreservesPreviousSnapshotDuringTransientFallback(t *testing.
client,
node,
"healthy",
- map[string]models.Memory{first.ID: first.Memory},
nil,
)
if err != nil {
@@ -302,7 +301,6 @@ func TestPollPVENodePreservesPreviousSnapshotDuringTransientFallback(t *testing.
client,
node,
"healthy",
- map[string]models.Memory{second.ID: second.Memory},
nil,
)
if err != nil {
diff --git a/internal/monitoring/monitor_additional_test.go b/internal/monitoring/monitor_additional_test.go
index bc771e5d42..6a9b566dae 100644
--- a/internal/monitoring/monitor_additional_test.go
+++ b/internal/monitoring/monitor_additional_test.go
@@ -1158,3 +1158,430 @@ func TestTenantDeletionWaitsForSlowMonitoringLoop(t *testing.T) {
}
mtm.FinishTenantDeletion("deletion")
}
+
+// The poller reads the previous poll's nodes back through the unified read
+// state. Those lookups key on the Proxmox source ID, so the projection must
+// return it (not the registry's unified resource ID) and carry the stored
+// temperature; otherwise the node's CPU low/record values reset to the
+// current reading every poll and a failed collection never carries over.
+func TestPreviousNodeProjectionFeedsPollerTemperatureTracking(t *testing.T) {
+ instanceCfg := config.PVEInstance{Name: "pve1", Host: "https://10.0.0.1:8006"}
+ adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(nil))
+ m := &Monitor{
+ config: &config.Config{TemperatureMonitoringEnabled: true, PVEInstances: []config.PVEInstance{instanceCfg}},
+ state: models.NewState(),
+ resourceStore: adapter,
+ }
+ base := models.Node{ID: "pve1-node1", NodeIdentity: "pve1-node1", Name: "node1", Instance: "pve1", Status: "online", Type: "node"}
+
+ // publish rebuilds the unified store from state the way the monitor does,
+ // alongside the host agents' latest reports.
+ var hosts []models.Host
+ publish := func() {
+ snapshot := m.state.GetSnapshot()
+ snapshot.Hosts = hosts
+ adapter.PopulateFromSnapshot(snapshot)
+ }
+ // poll delivers an agent report (none when agentReading is 0), runs one PVE
+ // poll's temperature step against the previous poll's nodes, and publishes
+ // the polled node.
+ poll := func(agentReading float64) *models.Temperature {
+ t.Helper()
+ hosts = nil
+ if agentReading > 0 {
+ hosts = []models.Host{{
+ ID: "agent-1", Hostname: "node1", Status: "online", LinkedNodeID: base.ID, IntervalSeconds: 30, LastSeen: time.Now(),
+ Sensors: models.HostSensorSummary{TemperatureCelsius: map[string]float64{"cpu_package": agentReading}},
+ }}
+ }
+ publish()
+ prevNodes := m.snapshotPrevNodes("pve1")
+ polled := base
+ polled.LastSeen = time.Now()
+ m.collectNodeTemperatureData(context.Background(), "pve1", &instanceCfg, proxmox.Node{Node: "node1"}, &polled, prevNodes, "online")
+ m.state.UpdateNodesForInstance("pve1", []models.Node{polled})
+ publish()
+ return polled.Temperature
+ }
+
+ if temp := poll(50); temp == nil || temp.CPUMin != 50 || temp.CPUMaxRecord != 50 {
+ t.Fatalf("first reading = %#v, want min and record initialised to 50", temp)
+ }
+ prevNodes := m.snapshotPrevNodes("pve1")
+ if len(prevNodes) != 1 || prevNodes[0].ID != base.ID || prevNodes[0].Temperature == nil {
+ t.Fatalf("previous nodes = %#v, want source ID %q with its temperature", prevNodes, base.ID)
+ }
+
+ if temp := poll(62); temp == nil || temp.CPUPackage != 62 || temp.CPUMin != 50 || temp.CPUMaxRecord != 62 {
+ t.Fatalf("second reading = %#v, want current 62, low 50, record 62", temp)
+ }
+ third := poll(45)
+ if third == nil || third.CPUPackage != 45 || third.CPUMin != 45 || third.CPUMaxRecord != 62 {
+ t.Fatalf("third reading = %#v, want current 45, low 45, record 62", third)
+ }
+
+ // No agent and no SSH collector: the last reading carries over with its
+ // original timestamp, inside the carry window.
+ carried := poll(0)
+ if carried == nil || carried.CPUPackage != 45 || !carried.LastUpdate.Equal(third.LastUpdate) {
+ t.Fatalf("carried reading = %#v, want the previous 45 with its original timestamp", carried)
+ }
+}
+
+// When a whole Proxmox instance stops answering, its last-known nodes are
+// written back into state through the offline grace policy. That writeback
+// must keep each node the same resource: the poller's source ID and the
+// config-derived identity the registry derives a cluster member's canonical ID
+// from. Past grace the node goes offline and stops presenting a temperature.
+func TestPVEOutageWritebackKeepsNodeIdentity(t *testing.T) {
+ for _, tc := range []struct {
+ name string
+ instances []config.PVEInstance
+ wantID string
+ providerScoped bool
+ }{
+ {
+ name: "cluster member",
+ instances: []config.PVEInstance{{Name: "pve-a", Host: "https://10.0.0.1:8006", IsCluster: true, ClusterName: "lab"}},
+ wantID: "lab-node1",
+ },
+ {
+ name: "cluster name shared by two connections",
+ instances: []config.PVEInstance{
+ {Name: "pve-a", Host: "https://10.0.0.1:8006", IsCluster: true, ClusterName: "lab"},
+ {Name: "pve-b", Host: "https://10.0.1.1:8006", IsCluster: true, ClusterName: "lab"},
+ },
+ wantID: "pve-a-node1",
+ providerScoped: true,
+ },
+ } {
+ t.Run(tc.name, func(t *testing.T) {
+ adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(nil))
+ m := &Monitor{
+ config: &config.Config{PVEInstances: tc.instances},
+ state: models.NewState(),
+ resourceStore: adapter,
+ nodeLastOnline: make(map[string]time.Time),
+ }
+ instanceCfg := m.getInstanceConfig("pve-a")
+ if got := m.pveNodeID("pve-a", instanceCfg, "node1"); got != tc.wantID {
+ t.Fatalf("pveNodeID = %q, want %q", got, tc.wantID)
+ }
+ now := time.Now()
+ polled := m.placeholderNodeForInstance("pve-a", instanceCfg, "node1")
+ polled.Status = "online"
+ polled.ConnectionHealth = "healthy"
+ polled.LastSeen = now
+ polled.Temperature = &models.Temperature{CPUPackage: 55, Available: true, HasCPU: true, LastUpdate: now}
+ if polled.ProviderScopedIdentity != tc.providerScoped {
+ t.Fatalf("ProviderScopedIdentity = %v, want %v", polled.ProviderScopedIdentity, tc.providerScoped)
+ }
+ m.nodeLastOnline[polled.ID] = now
+ m.state.UpdateNodesForInstance("pve-a", []models.Node{polled})
+ adapter.PopulateFromSnapshot(m.state.GetSnapshot())
+ unifiedID := adapter.Nodes()[0].ID()
+
+ for cycle := 0; cycle < 3; cycle++ {
+ m.markPVEInstanceNodesUnreachable("pve-a")
+ adapter.PopulateFromSnapshot(m.state.GetSnapshot())
+ stateNodes := m.state.GetSnapshot().Nodes
+ if len(stateNodes) != 1 || stateNodes[0].ID != tc.wantID || stateNodes[0].ClusterName != "lab" ||
+ stateNodes[0].ProviderScopedIdentity != tc.providerScoped {
+ t.Fatalf("cycle %d: state nodes = %#v, want %q kept with its cluster identity", cycle, stateNodes, tc.wantID)
+ }
+ if stateNodes[0].Status != "online" || stateNodes[0].Temperature == nil {
+ t.Fatalf("cycle %d: node within grace = %#v, want online with its recent temperature", cycle, stateNodes[0])
+ }
+ if nodes := adapter.Nodes(); len(nodes) != 1 || nodes[0].ID() != unifiedID {
+ t.Fatalf("cycle %d: unified nodes = %v, want the single resource %q", cycle, nodes, unifiedID)
+ }
+ }
+
+ // The process last saw the node online beyond the grace period.
+ m.nodeLastOnline[polled.ID] = now.Add(-2 * nodeOfflineGracePeriod)
+ polled.LastSeen = now.Add(-2 * nodeOfflineGracePeriod)
+ m.state.UpdateNodesForInstance("pve-a", []models.Node{polled})
+ adapter.PopulateFromSnapshot(m.state.GetSnapshot())
+ m.markPVEInstanceNodesUnreachable("pve-a")
+ adapter.PopulateFromSnapshot(m.state.GetSnapshot())
+ expired := m.state.GetSnapshot().Nodes
+ if len(expired) != 1 || expired[0].ID != tc.wantID || expired[0].Status != "offline" || expired[0].Temperature != nil {
+ t.Fatalf("expired nodes = %#v, want %q offline without a temperature", expired, tc.wantID)
+ }
+ if nodes := adapter.Nodes(); len(nodes) != 1 || nodes[0].ID() != unifiedID {
+ t.Fatalf("unified nodes after expiry = %v, want the single resource %q", nodes, unifiedID)
+ }
+ })
+ }
+}
+
+// Within grace a preserved node keeps its temperature only while the reading
+// is inside the same carry window a failed collection gets.
+func TestPreserveOrExpireNodesBoundsGraceTemperature(t *testing.T) {
+ m := &Monitor{config: &config.Config{}, state: models.NewState(), nodeLastOnline: make(map[string]time.Time)}
+ now := time.Now()
+ m.nodeLastOnline["pve-node1"] = now
+ stale := now.Add(-m.nodeTemperatureCarryWindow() - time.Minute)
+ preserved := m.preserveOrExpireNodes([]models.Node{{
+ ID: "pve-node1", Name: "node1", Status: "online", LastSeen: now,
+ Temperature: &models.Temperature{CPUPackage: 70, Available: true, LastUpdate: stale},
+ }})
+ if len(preserved) != 1 || preserved[0].Status != "online" || preserved[0].Temperature != nil {
+ t.Fatalf("preserved = %#v, want online within grace without the stale temperature", preserved)
+ }
+}
+
+// When detailed node status fails, the poller may carry its own last trusted
+// memory reading for one cycle. On a node merged with a host agent, the read
+// state holds the agent's memory, which is not the Proxmox value the snapshot
+// vouches for, so the carry must use the snapshot and keep its used, cache
+// and free split summing to the total.
+func TestPollPVENodeCarriesOwnMemorySnapshot(t *testing.T) {
+ t.Setenv("PULSE_DATA_DIR", t.TempDir())
+ const gib = uint64(1024 * 1024 * 1024)
+
+ mon := newTestPVEMonitor("test")
+ defer mon.alertManager.Stop()
+ defer mon.notificationMgr.Stop()
+ adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(nil))
+ mon.resourceStore = adapter
+
+ client := &stubPVEClient{nodeStatus: &proxmox.NodeStatus{
+ Memory: &proxmox.MemoryStatus{Total: 16 * gib, Used: 12 * gib, Free: 1 * gib, Available: 8 * gib},
+ }}
+ node := proxmox.Node{Node: "node1", Status: "online", MaxMem: 16 * gib, Mem: 15 * gib, MaxCPU: 8}
+
+ first, _, _, err := mon.pollPVENode(context.Background(), "test", &mon.config.PVEInstances[0], client, node, "healthy", nil)
+ if err != nil {
+ t.Fatalf("first pollPVENode() error = %v", err)
+ }
+ if !first.Memory.HasKnownUsage() || first.Memory.Used != int64(8*gib) || first.Memory.Cache == 0 {
+ t.Fatalf("first.Memory = %+v, want 8 GiB used with reclaimable cache split out", first.Memory)
+ }
+ mon.state.UpdateNodesForInstance("test", []models.Node{first})
+ snapshot := mon.state.GetSnapshot()
+ snapshot.Hosts = []models.Host{{
+ ID: "agent-1", Hostname: "node1", Status: "online", LinkedNodeID: first.ID, IntervalSeconds: 30, LastSeen: time.Now(),
+ Memory: models.Memory{Total: int64(16 * gib), Used: int64(3 * gib), Free: int64(13 * gib), Usage: 18.75},
+ }}
+ adapter.PopulateFromSnapshot(snapshot)
+
+ client.nodeStatus = nil
+ second, _, _, err := mon.pollPVENode(context.Background(), "test", &mon.config.PVEInstances[0], client, node, "healthy", mon.snapshotPrevNodes("test"))
+ if err != nil {
+ t.Fatalf("second pollPVENode() error = %v", err)
+ }
+ if second.Memory.Used != first.Memory.Used || second.Memory.Cache != first.Memory.Cache || second.Memory.Free != first.Memory.Free {
+ t.Fatalf("second.Memory = %+v, want the poller's own reading %+v", second.Memory, first.Memory)
+ }
+ if second.Memory.Used+second.Memory.Cache+second.Memory.Free != second.Memory.Total {
+ t.Fatalf("second.Memory = %+v, want used + cache + free = total", second.Memory)
+ }
+ if snap := mon.nodeSnapshots[makeNodeSnapshotKey("test", "node1")]; snap.MemorySource != "previous-snapshot" {
+ t.Fatalf("snapshot.MemorySource = %q, want previous-snapshot", snap.MemorySource)
+ }
+}
+
+// Authoritative cluster membership writes previous nodes back too. Read from
+// the unified store, an offline member keeps its source ID and agent link but
+// stops presenting a temperature, and a member missing from /nodes keeps a
+// reading only inside the carry window.
+func TestPVEMembershipReconcileKeepsPreviousNodeIdentity(t *testing.T) {
+ cfg := &config.Config{PVEInstances: []config.PVEInstance{{
+ Name: "cluster-api", Host: "https://pve-a:8006", IsCluster: true, ClusterName: "production",
+ }}}
+ m := newUnreachableTestMonitor(t, cfg)
+ adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(nil))
+ m.resourceStore = adapter
+ instanceCfg := &cfg.PVEInstances[0]
+ now := time.Now()
+ polled := func(name string, tempAge time.Duration) models.Node {
+ node := m.placeholderNodeForInstance("cluster-api", instanceCfg, name)
+ node.Status = "online"
+ node.ConnectionHealth = "healthy"
+ node.LastSeen = now
+ node.Temperature = &models.Temperature{CPUPackage: 60, Available: true, HasCPU: true, LastUpdate: now.Add(-tempAge)}
+ return node
+ }
+ offlineMember := polled("pve-a", 0)
+ offlineMember.LinkedAgentID = "agent-pve-a"
+ m.state.UpdateNodesForInstance("cluster-api", []models.Node{
+ offlineMember, polled("pve-b", 0), polled("pve-c", m.nodeTemperatureCarryWindow()+time.Minute),
+ })
+ adapter.PopulateFromSnapshot(m.state.GetSnapshot())
+
+ client := &membershipPVEClient{statuses: []proxmox.ClusterStatus{
+ {Type: "cluster", Name: "production", Quorate: 1},
+ {Type: "node", Name: "pve-a", Online: 0},
+ {Type: "node", Name: "pve-b", Online: 1},
+ {Type: "node", Name: "pve-c", Online: 1},
+ }}
+ got := pveNodeByName(m.reconcilePVENodeInventory(
+ context.Background(), "cluster-api", instanceCfg, client, nil, m.snapshotPrevNodes("cluster-api"),
+ ))
+
+ if node := got["pve-a"]; node.ID != "production-pve-a" || node.Status != "offline" || node.Temperature != nil || node.LinkedAgentID != "agent-pve-a" {
+ t.Fatalf("offline member = %#v, want production-pve-a offline with its agent link and no temperature", node)
+ }
+ if node := got["pve-b"]; node.ID != "production-pve-b" || node.Status != "unknown" || node.Temperature == nil {
+ t.Fatalf("unobserved member = %#v, want production-pve-b unknown with its recent temperature", node)
+ }
+ if node := got["pve-c"]; node.ID != "production-pve-c" || node.Status != "unknown" || node.Temperature != nil {
+ t.Fatalf("unobserved member = %#v, want production-pve-c unknown without its stale temperature", node)
+ }
+
+ // Writing the reconciled inventory back keeps every member the same
+ // unified resource.
+ unifiedIDs := func() map[string]string {
+ ids := make(map[string]string)
+ for _, node := range adapter.Nodes() {
+ ids[node.NodeName()] = node.ID()
+ }
+ return ids
+ }
+ before := unifiedIDs()
+ m.state.UpdateNodesForInstance("cluster-api", sortedPVENodeInventory(got))
+ adapter.PopulateFromSnapshot(m.state.GetSnapshot())
+ if after := unifiedIDs(); len(after) != 3 || after["pve-a"] != before["pve-a"] || after["pve-b"] != before["pve-b"] || after["pve-c"] != before["pve-c"] {
+ t.Fatalf("unified IDs after writeback = %v, want %v", after, before)
+ }
+}
+
+// A temperature carried over from an earlier poll keeps a lapsed host agent's
+// lease: a reading the agent supplied (stamped no later than its last report)
+// is dropped once the agent stops reporting, even when its latest report had
+// no sensors, while a reading taken after that report keeps the carry window.
+// The same rule bounds what an instance outage preserves within node grace.
+func TestNodeTemperatureCarryRespectsAgentLease(t *testing.T) {
+ now := time.Now()
+ silentSince := now.Add(-hostAgentHealthWindow(30) - time.Minute)
+ instanceCfg := config.PVEInstance{Name: "pve1", Host: "https://10.0.0.1:8006"}
+ base := models.Node{ID: "pve1-node1", NodeIdentity: "pve1-node1", Name: "node1", Instance: "pve1", Status: "online", Type: "node", LastSeen: now}
+
+ for _, tc := range []struct {
+ name string
+ readingAt time.Time
+ agentSensors bool
+ wantCarried bool
+ }{
+ {name: "reading from the silent agent", readingAt: silentSince, agentSensors: true},
+ {name: "silent agent whose last report had no sensors", readingAt: silentSince.Add(-30 * time.Second)},
+ {name: "SSH reading taken after the agent went silent", readingAt: now.Add(-time.Minute), agentSensors: true, wantCarried: true},
+ } {
+ t.Run(tc.name, func(t *testing.T) {
+ adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(nil))
+ m := &Monitor{
+ config: &config.Config{TemperatureMonitoringEnabled: true, PVEInstances: []config.PVEInstance{instanceCfg}},
+ state: models.NewState(),
+ resourceStore: adapter,
+ nodeLastOnline: map[string]time.Time{base.ID: now},
+ }
+ agent := models.Host{ID: "agent-1", Hostname: "node1", Status: "offline", LinkedNodeID: base.ID, IntervalSeconds: 30, LastSeen: silentSince}
+ if tc.agentSensors {
+ agent.Sensors = models.HostSensorSummary{TemperatureCelsius: map[string]float64{"cpu_package": 92}}
+ }
+ published := base
+ published.Temperature = &models.Temperature{CPUPackage: 92, CPUMin: 92, CPUMaxRecord: 92, Available: true, HasCPU: true, LastUpdate: tc.readingAt}
+ m.state.UpdateNodesForInstance("pve1", []models.Node{published})
+ snapshot := m.state.GetSnapshot()
+ snapshot.Hosts = []models.Host{agent}
+ adapter.PopulateFromSnapshot(snapshot)
+
+ polled := base
+ m.collectNodeTemperatureData(context.Background(), "pve1", &instanceCfg, proxmox.Node{Node: "node1"}, &polled, m.snapshotPrevNodes("pve1"), "online")
+ if carried := polled.Temperature != nil; carried != tc.wantCarried {
+ t.Fatalf("failed collection carried = %v (%#v), want %v", carried, polled.Temperature, tc.wantCarried)
+ }
+
+ preserved := m.preserveOrExpireNodes(m.snapshotPrevNodes("pve1"))
+ if len(preserved) != 1 || preserved[0].Status != "online" {
+ t.Fatalf("preserved = %#v, want the node online within grace", preserved)
+ }
+ if kept := preserved[0].Temperature != nil; kept != tc.wantCarried {
+ t.Fatalf("outage preservation kept temperature = %v, want %v", kept, tc.wantCarried)
+ }
+ })
+ }
+}
+
+// A carried node reading keeps the node's CPU temperature steady through a
+// failed collection, but never its disk temperatures: those also stamp the
+// node's physical disks, which have their own freshness and standby state.
+// Here a current agent whose only sensor is a SMART disk reports that disk in
+// standby, so collection returns nothing; the disk must not be re-stamped with
+// its pre-sleep reading through the carry.
+func TestCarriedNodeTemperatureLeavesDiskReadingsOut(t *testing.T) {
+ now := time.Now()
+ instanceCfg := config.PVEInstance{Name: "pve1", Host: "https://10.0.0.1:8006"}
+ base := models.Node{ID: "pve1-node1", NodeIdentity: "pve1-node1", Name: "node1", Instance: "pve1", Status: "online", Type: "node", LastSeen: now}
+ disk := models.PhysicalDisk{ID: "pve1-node1-sda", Node: "node1", Instance: "pve1", DevPath: "/dev/sda", Serial: "WD-STANDBY", Type: "hdd"}
+
+ for _, tc := range []struct {
+ name string
+ previous models.Temperature
+ wantCPU bool
+ }{
+ {
+ name: "CPU and disk reading",
+ previous: models.Temperature{
+ Available: true, HasCPU: true, CPUPackage: 50, HasSMART: true, HasNVMe: true,
+ SMART: []models.DiskTemp{{Device: "/dev/sda", Serial: "WD-STANDBY", Temperature: 38}},
+ NVMe: []models.NVMeTemp{{Device: "nvme0", Temp: 44}},
+ },
+ wantCPU: true,
+ },
+ {
+ name: "disk-only reading",
+ previous: models.Temperature{
+ Available: true, HasSMART: true,
+ SMART: []models.DiskTemp{{Device: "/dev/sda", Serial: "WD-STANDBY", Temperature: 38}},
+ },
+ },
+ } {
+ t.Run(tc.name, func(t *testing.T) {
+ adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(nil))
+ m := &Monitor{
+ config: &config.Config{TemperatureMonitoringEnabled: true, PVEInstances: []config.PVEInstance{instanceCfg}},
+ state: models.NewState(),
+ resourceStore: adapter,
+ nodeLastOnline: map[string]time.Time{base.ID: now},
+ }
+ published := base
+ previous := tc.previous
+ previous.LastUpdate = now.Add(-time.Minute)
+ published.Temperature = &previous
+ m.state.UpdateNodesForInstance("pve1", []models.Node{published})
+ snapshot := m.state.GetSnapshot()
+ snapshot.Hosts = []models.Host{{
+ ID: "agent-1", Hostname: "node1", Status: "online", LinkedNodeID: base.ID, IntervalSeconds: 30, LastSeen: now,
+ Sensors: models.HostSensorSummary{SMART: []models.HostDiskSMART{{Device: "sda", Serial: "WD-STANDBY", Standby: true}}},
+ }}
+ adapter.PopulateFromSnapshot(snapshot)
+
+ polled := base
+ m.collectNodeTemperatureData(context.Background(), "pve1", &instanceCfg, proxmox.Node{Node: "node1"}, &polled, m.snapshotPrevNodes("pve1"), "online")
+ if tc.wantCPU {
+ if polled.Temperature == nil || polled.Temperature.CPUPackage != 50 || !polled.Temperature.LastUpdate.Equal(previous.LastUpdate) {
+ t.Fatalf("carried temperature = %#v, want CPU 50 with its original timestamp", polled.Temperature)
+ }
+ if len(polled.Temperature.SMART) != 0 || len(polled.Temperature.NVMe) != 0 || polled.Temperature.HasSMART || polled.Temperature.HasNVMe {
+ t.Fatalf("carried temperature kept disk readings: %#v", polled.Temperature)
+ }
+ } else if polled.Temperature != nil {
+ t.Fatalf("carried temperature = %#v, want none when only disk readings were left", polled.Temperature)
+ }
+ if stamped := mergeNVMeTempsIntoDisks([]models.PhysicalDisk{disk}, []models.Node{polled}); stamped[0].Temperature != 0 {
+ t.Fatalf("standby disk stamped with %d°C from a carried reading, want no reading", stamped[0].Temperature)
+ }
+
+ // Outage preservation follows the same rule.
+ preserved := m.preserveOrExpireNodes(m.snapshotPrevNodes("pve1"))
+ if len(preserved) != 1 {
+ t.Fatalf("preserved = %#v, want one node", preserved)
+ }
+ if got := preserved[0].Temperature; (got != nil) != tc.wantCPU || (got != nil && (len(got.SMART) != 0 || len(got.NVMe) != 0)) {
+ t.Fatalf("preserved temperature = %#v, want CPU only (%v)", got, tc.wantCPU)
+ }
+ })
+ }
+}
diff --git a/internal/monitoring/monitor_alert_handling_test.go b/internal/monitoring/monitor_alert_handling_test.go
index 8ecdeb2250..1e84d90190 100644
--- a/internal/monitoring/monitor_alert_handling_test.go
+++ b/internal/monitoring/monitor_alert_handling_test.go
@@ -1547,22 +1547,24 @@ func TestSilentLinkedAgentStopsRefreshingNodeTemperatureAlert(t *testing.T) {
alertConfig.NodeDefaults.Temperature = &alerts.HysteresisThreshold{Trigger: 80, Clear: 75}
manager.UpdateConfig(alertConfig)
- registry := unifiedresources.NewRegistry(nil)
+ adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(nil))
monitor := &Monitor{
config: &config.Config{TemperatureMonitoringEnabled: true},
state: models.NewState(),
- resourceStore: unifiedresources.NewMonitorAdapter(registry),
+ resourceStore: adapter,
}
node := models.Node{
ID: "pve1-node1", Name: "node1", Instance: "pve1", Status: "online",
ConnectionHealth: "healthy", LinkedAgentID: "agent-1",
}
- // ingest records a PVE poll that just saw the node, plus the agent as of its
- // last report.
+ // ingest rebuilds the store, as each monitor refresh does, from the last PVE
+ // poll's node (with the temperature it published, which the next poll reads
+ // back as its previous node) plus the agent as of its last report.
+ lastPolled := node
ingest := func(agentLastReport time.Time, agentStatus string) {
- polledNode := node
+ polledNode := lastPolled
polledNode.LastSeen = time.Now()
- registry.IngestSnapshot(models.StateSnapshot{
+ adapter.PopulateFromSnapshot(models.StateSnapshot{
Nodes: []models.Node{polledNode},
Hosts: []models.Host{{
ID: "agent-1", Hostname: "node1", Status: agentStatus, LinkedNodeID: node.ID,
@@ -1574,13 +1576,14 @@ func TestSilentLinkedAgentStopsRefreshingNodeTemperatureAlert(t *testing.T) {
// poll runs the node temperature step of a PVE poll (no SSH collector) and
// evaluates the node's alerts with the result.
poll := func() *models.Temperature {
- _, prevNodes := monitor.snapshotPrevNodes("pve1")
+ prevNodes := monitor.snapshotPrevNodes("pve1")
polled := node
monitor.collectNodeTemperatureData(
context.Background(), "pve1", &config.PVEInstance{Name: "pve1"}, proxmox.Node{Node: node.Name},
&polled, prevNodes, "online",
)
manager.CheckNode(polled)
+ lastPolled = polled
return polled.Temperature
}
temperatureAlert := func() alerts.Alert {
@@ -1605,8 +1608,15 @@ func TestSilentLinkedAgentStopsRefreshingNodeTemperatureAlert(t *testing.T) {
opened := temperatureAlert()
// The agent goes silent while PVE polling continues: the merged row stays
- // fresh, but the agent's retained sensors no longer count as a reading.
- ingest(time.Now().Add(-hostAgentHealthWindow(30)-time.Minute), "offline")
+ // fresh, but the agent's retained sensors no longer count as a reading, and
+ // the poller does not carry the agent's last reading past its lease. With no
+ // clock to advance, age the agent's last report and the reading it produced
+ // by the same amount.
+ silence := hostAgentHealthWindow(30) + time.Minute
+ agedReading := *lastPolled.Temperature
+ agedReading.LastUpdate = agedReading.LastUpdate.Add(-silence)
+ lastPolled.Temperature = &agedReading
+ ingest(agentReport.Add(-silence), "offline")
time.Sleep(5 * time.Millisecond)
require.Nil(t, poll(), "a silent agent's retained sensors must not be presented as a current reading")
held := temperatureAlert()
diff --git a/internal/monitoring/monitor_extra_coverage_test.go b/internal/monitoring/monitor_extra_coverage_test.go
index 4060fc88cc..23caafd87e 100644
--- a/internal/monitoring/monitor_extra_coverage_test.go
+++ b/internal/monitoring/monitor_extra_coverage_test.go
@@ -2132,22 +2132,32 @@ func TestMonitor_PreviousNodesForInstance_Extra(t *testing.T) {
registry := unifiedresources.NewRegistry(nil)
registry.IngestSnapshot(models.StateSnapshot{
Nodes: []models.Node{
- {ID: "node-1", Instance: "pve1", Name: "a", DisplayName: "a", Memory: models.Memory{Total: 100}},
+ {
+ ID: "node-1", Instance: "pve1", Name: "a", DisplayName: "a", ClusterName: "lab",
+ Memory: models.Memory{Total: 100, Used: 40, Free: 60, Usage: 40},
+ Temperature: &models.Temperature{CPUPackage: 52, CPUMin: 41, CPUMaxRecord: 70, Available: true, HasCPU: true},
+ },
{ID: "node-2", Instance: "pve2", Name: "b", DisplayName: "b", Memory: models.Memory{Total: 200}},
},
})
m.resourceStore = unifiedresources.NewMonitorAdapter(registry)
- prevNodeMemory, prevNodes := m.previousNodesForInstance("pve1")
+ prevNodes := m.previousNodesForInstance("pve1")
if len(prevNodes) != 1 || prevNodes[0].Instance != "pve1" || prevNodes[0].DisplayName != "a" {
t.Fatalf("expected only pve1 nodes, got %#v", prevNodes)
}
- if mem, ok := prevNodeMemory[prevNodes[0].ID]; !ok || mem.Total != 100 {
- t.Fatalf("expected node memory for node-1, got %#v", prevNodeMemory)
+ // The poller matches previous nodes by its own source ID, never the
+ // registry's unified resource ID.
+ if prevNodes[0].ID != "node-1" || prevNodes[0].NodeIdentity != "node-1" {
+ t.Fatalf("previous node ID = %q / identity %q, want source ID node-1", prevNodes[0].ID, prevNodes[0].NodeIdentity)
+ }
+ if prevNodes[0].ClusterName != "lab" || prevNodes[0].Memory.Total != 100 || prevNodes[0].Memory.Used != 40 {
+ t.Fatalf("previous node lost cluster or memory: %#v", prevNodes[0])
}
- if len(prevNodeMemory) != 1 {
- t.Fatalf("expected node-2 to be filtered out, got %#v", prevNodeMemory)
+ temp := prevNodes[0].Temperature
+ if temp == nil || temp.CPUPackage != 52 || temp.CPUMin != 41 || temp.CPUMaxRecord != 70 {
+ t.Fatalf("previous node temperature = %#v, want the stored reading with its min/max records", temp)
}
}
diff --git a/internal/monitoring/monitor_memory_test.go b/internal/monitoring/monitor_memory_test.go
index df2a659a1b..84042d56fd 100644
--- a/internal/monitoring/monitor_memory_test.go
+++ b/internal/monitoring/monitor_memory_test.go
@@ -366,6 +366,11 @@ func TestPollPVEInstanceMarksStaleNodesOfflineWhenGetNodesReturnsEmpty(t *testin
staleNode := first.Nodes[0]
staleNode.LastSeen = time.Now().Add(-nodeOfflineGracePeriod - 2*time.Second)
mon.state.UpdateNodesForInstance("test", []models.Node{staleNode})
+ // The grace policy also counts this process's own online sighting, keyed
+ // by the node's source ID, so age that too.
+ mon.mu.Lock()
+ mon.nodeLastOnline[staleNode.ID] = staleNode.LastSeen
+ mon.mu.Unlock()
client.nodes = nil
mon.pollPVEInstance(context.Background(), "test", client)
diff --git a/internal/monitoring/monitor_polling_node.go b/internal/monitoring/monitor_polling_node.go
index 035897cdc3..a2b301f63a 100644
--- a/internal/monitoring/monitor_polling_node.go
+++ b/internal/monitoring/monitor_polling_node.go
@@ -96,26 +96,31 @@ func collectPVENodeNetworkInterfaces(
return mapPVENodeNetworkInterfaces(interfaces)
}
-func (m *Monitor) canCarryForwardNodeMemory(instance, node string, now time.Time) bool {
+// carryForwardNodeMemory returns the node's last memory reading from this
+// poller's own snapshot when that reading came from a trusted source recently
+// enough to stand in for one failed status read. The unified read state is not
+// used here: on a node merged with a host agent it holds the agent's reading,
+// not the Proxmox value this snapshot vouches for.
+func (m *Monitor) carryForwardNodeMemory(instance, node string, now time.Time) (models.Memory, bool) {
if m == nil {
- return false
+ return models.Memory{}, false
}
m.diagMu.RLock()
snapshot, ok := m.nodeSnapshots[makeNodeSnapshotKey(instance, node)]
m.diagMu.RUnlock()
if !ok || !snapshot.Memory.HasKnownUsage() || snapshot.RetrievedAt.IsZero() {
- return false
+ return models.Memory{}, false
}
age := now.Sub(snapshot.RetrievedAt)
if age < 0 || age > nodeMemoryCarryForwardMaxAge {
- return false
+ return models.Memory{}, false
}
switch CanonicalMemorySource(snapshot.MemorySource) {
case "available-field", "derived-free-buffers-cached", "derived-total-minus-used",
"rrd-memavailable", "rrd-memused":
- return true
+ return snapshot.Memory, true
default:
- return false
+ return models.Memory{}, false
}
}
@@ -126,7 +131,6 @@ func (m *Monitor) pollPVENode(
client PVEClientInterface,
node proxmox.Node,
connectionHealthStr string,
- prevNodeMemory map[string]models.Memory,
prevInstanceNodes []models.Node,
) (models.Node, string, string, error) {
nodeStart := time.Now()
@@ -314,10 +318,8 @@ func (m *Monitor) pollPVENode(
}
// If we couldn't update memory metrics using detailed status, preserve previous accurate values if available
- if !memoryUpdated &&
- effectiveStatus == "online" &&
- m.canCarryForwardNodeMemory(instanceName, node.Node, time.Now()) {
- if prevMem, exists := prevNodeMemory[modelNode.ID]; exists && prevMem.HasKnownUsage() {
+ if !memoryUpdated && effectiveStatus == "online" {
+ if prevMem, ok := m.carryForwardNodeMemory(instanceName, node.Node, time.Now()); ok {
total := int64(node.MaxMem)
if total == 0 {
total = prevMem.Total
@@ -326,14 +328,14 @@ func (m *Monitor) pollPVENode(
if total > 0 && used > total {
used = total
}
- free := total - used
- if free < 0 {
- free = 0
- }
+ // Keep the snapshot's used | cache | free split summing to total.
+ cache := min(max(prevMem.Cache, 0), max(total-used, 0))
+ free := max(total-used-cache, 0)
preserved := prevMem
preserved.Total = total
preserved.Used = used
+ preserved.Cache = cache
preserved.Free = free
preserved.Usage = safePercentage(float64(used), float64(total))
diff --git a/internal/monitoring/monitor_polling_node_helpers.go b/internal/monitoring/monitor_polling_node_helpers.go
index ced65961a2..e8ef1e849a 100644
--- a/internal/monitoring/monitor_polling_node_helpers.go
+++ b/internal/monitoring/monitor_polling_node_helpers.go
@@ -331,7 +331,15 @@ func (m *Monitor) collectNodeTemperatureData(
}
}
- if prevTemp != nil && time.Since(prevTemp.LastUpdate) > m.nodeTemperatureCarryWindow() {
+ if m.carriedTemperatureOutlivesAgentLease(modelNode.ID, node.Node, prevTemp, time.Now()) {
+ // The reading came from a host agent that has stopped reporting.
+ // Its reporting lease already rode out transient gaps, so
+ // carrying it would outlive that lease.
+ log.Debug().
+ Str("node", node.Node).
+ Time("lastUpdate", prevTemp.LastUpdate).
+ Msg("Dropped temperature data (host agent stopped reporting)")
+ } else if prevTemp != nil && time.Since(prevTemp.LastUpdate) > m.nodeTemperatureCarryWindow() {
// Collection has stayed broken past the carry window. Re-presenting
// the old reading would let alerts, history and the UI treat it as
// a live measurement forever, so the node has no reading now.
@@ -340,11 +348,9 @@ func (m *Monitor) collectNodeTemperatureData(
Bool("isCluster", modelNode.IsClusterMember).
Time("lastUpdate", prevTemp.LastUpdate).
Msg("Dropped stale temperature data (collection has not returned a reading within the carry window)")
- } else if prevTemp != nil {
- // Clone the previous temperature to avoid modifying historical data
- preserved := *prevTemp
- preserved.LastUpdate = prevTemp.LastUpdate // Keep original update time to indicate staleness
- modelNode.Temperature = &preserved
+ } else if preserved := carriedNodeTemperature(prevTemp); preserved != nil {
+ // The carried copy keeps its original LastUpdate to indicate staleness.
+ modelNode.Temperature = preserved
log.Debug().
Str("node", node.Node).
Bool("isCluster", modelNode.IsClusterMember).
@@ -361,6 +367,30 @@ func (m *Monitor) collectNodeTemperatureData(
}
}
+// carriedNodeTemperature returns the part of an earlier reading a node may
+// keep presenting while collection fails: its CPU and GPU temperatures, with
+// the original LastUpdate. Disk temperatures (SMART, NVMe) are left out. They
+// also stamp the node's physical disks, which have their own freshness and
+// standby state that a carried copy cannot follow: a disk that spun down would
+// be stamped, and recorded, with its pre-sleep reading. Returns nil when the
+// earlier reading held nothing else.
+func carriedNodeTemperature(prev *models.Temperature) *models.Temperature {
+ if prev == nil || !prev.Available {
+ return nil
+ }
+ carried := *prev
+ carried.Cores = append([]models.CoreTemp(nil), prev.Cores...)
+ carried.GPU = append([]models.GPUTemp(nil), prev.GPU...)
+ carried.SMART = []models.DiskTemp{}
+ carried.HasSMART = false
+ carried.NVMe = []models.NVMeTemp{}
+ carried.HasNVMe = false
+ if !hasUsableTemperatureReading(&carried) {
+ return nil
+ }
+ return &carried
+}
+
func (m *Monitor) applyNodePendingUpdates(ctx context.Context, instanceName string, client PVEClientInterface, node proxmox.Node, nodeID string, effectiveStatus string, modelNode *models.Node) {
if modelNode == nil {
return
diff --git a/internal/monitoring/monitor_previous_state.go b/internal/monitoring/monitor_previous_state.go
index bfd30496c9..79568436ef 100644
--- a/internal/monitoring/monitor_previous_state.go
+++ b/internal/monitoring/monitor_previous_state.go
@@ -3,6 +3,7 @@ package monitoring
import (
"strings"
+ "github.com/rcourtman/pulse-go-rewrite/internal/config"
"github.com/rcourtman/pulse-go-rewrite/internal/models"
"github.com/rcourtman/pulse-go-rewrite/internal/unifiedresources"
)
@@ -89,24 +90,31 @@ func (m *Monitor) previousGuestContextForInstance(instanceName string) previousG
return ctx
}
-func (m *Monitor) previousNodesForInstance(instanceName string) (map[string]models.Memory, []models.Node) {
- prevNodeMemory := make(map[string]models.Memory)
+func (m *Monitor) previousNodesForInstance(instanceName string) []models.Node {
prevInstanceNodes := make([]models.Node, 0)
readState := m.GetUnifiedReadStateOrSnapshot()
if readState == nil {
- return prevNodeMemory, prevInstanceNodes
+ return prevInstanceNodes
}
+ // The registry keeps no copy of the identity stamps pollPVENode derives
+ // from configuration, so restore them the same way. Nodes preserved through
+ // an instance outage are written back to state, and without these the
+ // registry would derive a different canonical identity for them.
+ instanceCfg := m.getInstanceConfig(instanceName)
+ providerScoped := m.pveNodeUsesProviderScopedIdentity(instanceName, instanceCfg)
for _, existingNode := range readState.Nodes() {
if existingNode == nil || existingNode.Instance() != instanceName {
continue
}
modelNode := previousNodeFromView(existingNode)
- prevNodeMemory[modelNode.ID] = modelNode.Memory
+ modelNode.ProviderScopedIdentity = providerScoped
+ modelNode.NativeNameAliases = config.PVEClusterNodeNativeAliases(instanceCfg, modelNode.Name)
+ modelNode.TLSFingerprint = pveNodeTLSFingerprint(instanceCfg, modelNode.Name)
prevInstanceNodes = append(prevInstanceNodes, modelNode)
}
- return prevNodeMemory, prevInstanceNodes
+ return prevInstanceNodes
}
func previousVMFromView(vm *unifiedresources.VMView) models.VM {
@@ -199,20 +207,33 @@ func previousNodeFromView(node *unifiedresources.NodeView) models.Node {
if node == nil {
return models.Node{}
}
+ // The poller keys nodes by their Proxmox source ID (nodeLastOnline, the
+ // temperature carry, state writes). The unified resource ID is a separate
+ // registry key, so returning it would match nothing, and writing it back
+ // during an outage would re-key the node on every failed poll.
+ id := node.SourceID()
+ if id == "" {
+ id = node.ID()
+ }
return models.Node{
- ID: node.ID(),
+ ID: id,
+ NodeIdentity: id,
Name: node.NodeName(),
DisplayName: node.Name(),
Instance: node.Instance(),
Host: node.HostURL(),
Status: string(node.Status()),
+ Type: "node",
Uptime: node.Uptime(),
IsClusterMember: node.IsClusterMember(),
+ ClusterName: node.ClusterName(),
LastSeen: node.LastSeen(),
LoadAverage: node.LoadAverage(),
PVEVersion: node.PVEVersion(),
KernelVersion: node.KernelVersion(),
NetworkInterfaces: hostNetworkInterfacesFromReadStateView(node.NetworkInterfaces()),
+ Temperature: node.TemperatureDetails(),
+ LinkedAgentID: node.LinkedAgentID(),
Memory: models.Memory{
Used: node.MemoryUsed(),
Total: node.MemoryTotal(),
diff --git a/internal/monitoring/monitor_pve.go b/internal/monitoring/monitor_pve.go
index 1394b9a20d..7f5405f896 100644
--- a/internal/monitoring/monitor_pve.go
+++ b/internal/monitoring/monitor_pve.go
@@ -587,7 +587,7 @@ func (m *Monitor) updatePVEConnectionHealth(ctx context.Context, instanceName st
return connectionHealthStr
}
-func (m *Monitor) snapshotPrevNodes(instanceName string) (map[string]models.Memory, []models.Node) {
+func (m *Monitor) snapshotPrevNodes(instanceName string) []models.Node {
return m.previousNodesForInstance(instanceName)
}
@@ -598,7 +598,6 @@ func (m *Monitor) pollPVENodesParallel(
client PVEClientInterface,
nodes []proxmox.Node,
connectionHealthStr string,
- prevNodeMemory map[string]models.Memory,
prevInstanceNodes []models.Node,
debugEnabled bool,
) ([]models.Node, map[string]string, map[string]string) {
@@ -627,7 +626,7 @@ func (m *Monitor) pollPVENodesParallel(
go func(node proxmox.Node) {
defer wg.Done()
- modelNode, effectiveStatus, diskSource, _ := m.pollPVENode(ctx, instanceName, instanceCfg, client, node, connectionHealthStr, prevNodeMemory, prevInstanceNodes)
+ modelNode, effectiveStatus, diskSource, _ := m.pollPVENode(ctx, instanceName, instanceCfg, client, node, connectionHealthStr, prevInstanceNodes)
resultChan <- nodePollResult{
node: modelNode,
@@ -655,7 +654,7 @@ func (m *Monitor) pollPVENodesParallel(
// leaves the last successful snapshot in state forever, so a shut-down host
// keeps showing its final online status (#1441).
func (m *Monitor) markPVEInstanceNodesUnreachable(instanceName string) {
- _, prevInstanceNodes := m.snapshotPrevNodes(instanceName)
+ prevInstanceNodes := m.snapshotPrevNodes(instanceName)
if len(prevInstanceNodes) == 0 {
// Never polled successfully this process lifetime (e.g. Pulse
// started while the host was already down). Synthesize offline
@@ -762,6 +761,7 @@ func (m *Monitor) preserveOrExpireNodes(prevInstanceNodes []models.Node) []model
if nodeCopy.ConnectionHealth == "" || strings.EqualFold(nodeCopy.ConnectionHealth, "error") {
nodeCopy.ConnectionHealth = "degraded"
}
+ m.boundCarriedNodeTemperature(&nodeCopy, now)
preserved = append(preserved, nodeCopy)
continue
}
@@ -770,11 +770,28 @@ func (m *Monitor) preserveOrExpireNodes(prevInstanceNodes []models.Node) []model
nodeCopy.ConnectionHealth = "error"
nodeCopy.Uptime = 0
nodeCopy.CPU = 0
+ nodeCopy.Temperature = nil
preserved = append(preserved, nodeCopy)
}
return preserved
}
+// boundCarriedNodeTemperature applies the rules a failed live collection's
+// carry follows to a temperature a node keeps from an earlier poll: the carry
+// window, a lapsed host agent's lease for a reading that agent supplied, and
+// no disk temperatures (carriedNodeTemperature).
+func (m *Monitor) boundCarriedNodeTemperature(node *models.Node, now time.Time) {
+ if node.Temperature == nil {
+ return
+ }
+ if now.Sub(node.Temperature.LastUpdate) > m.nodeTemperatureCarryWindow() ||
+ m.carriedTemperatureOutlivesAgentLease(node.ID, node.Name, node.Temperature, now) {
+ node.Temperature = nil
+ return
+ }
+ node.Temperature = carriedNodeTemperature(node.Temperature)
+}
+
func (m *Monitor) seedNodeDisplayNames(modelNodes []models.Node) {
for i := range modelNodes {
if modelNodes[i].DisplayName != "" {
@@ -1466,8 +1483,9 @@ func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, clie
// Check if client is a ClusterClient to determine health status
connectionHealthStr := m.updatePVEConnectionHealth(ctx, instanceName, client)
- // Capture previous memory metrics so we can preserve them if detailed status fails
- prevNodeMemory, prevInstanceNodes := m.snapshotPrevNodes(instanceName)
+ // Capture the previous poll's nodes for network, temperature and
+ // inventory continuity when this poll cannot read them.
+ prevInstanceNodes := m.snapshotPrevNodes(instanceName)
// Convert to models
modelNodes, nodeEffectiveStatus, nodeDiskSources := m.pollPVENodesParallel(
@@ -1477,7 +1495,6 @@ func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, clie
client,
nodes,
connectionHealthStr,
- prevNodeMemory,
prevInstanceNodes,
debugEnabled,
)
diff --git a/internal/monitoring/monitor_pve_cluster.go b/internal/monitoring/monitor_pve_cluster.go
index 083948619f..d03383f925 100644
--- a/internal/monitoring/monitor_pve_cluster.go
+++ b/internal/monitoring/monitor_pve_cluster.go
@@ -431,11 +431,13 @@ func (m *Monitor) reconcilePVENodeInventory(
node.ConnectionHealth = "error"
node.CPU = 0
node.Uptime = 0
+ node.Temperature = nil
} else if _, observed := currentByName[key]; !observed {
node.Status = "unknown"
node.ConnectionHealth = "degraded"
node.CPU = 0
node.Uptime = 0
+ m.boundCarriedNodeTemperature(&node, time.Now())
}
reconciled[key] = node
}
diff --git a/internal/monitoring/node_memory_sources_test.go b/internal/monitoring/node_memory_sources_test.go
index 70687c67d0..5e93730088 100644
--- a/internal/monitoring/node_memory_sources_test.go
+++ b/internal/monitoring/node_memory_sources_test.go
@@ -242,7 +242,6 @@ func TestPollPVENodePrefersLinkedHostDiskOverRootFS(t *testing.T) {
},
"healthy",
nil,
- nil,
)
if err != nil {
t.Fatalf("pollPVENode() error = %v", err)