Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Use guest meminfo available for VM memory usage
rcourtman2163d6f5a827
diff --git a/internal/monitoring/diagnostic_snapshots.go b/internal/monitoring/diagnostic_snapshots.goindex c88e97f36c..5667c883bd 100644--- a/internal/monitoring/diagnostic_snapshots.go+++ b/internal/monitoring/diagnostic_snapshots.go@@ -39,18 +39,22 @@ type NodeMemorySnapshot struct {// VMMemoryRaw captures both the listing and detailed status memory fields for a VM/CT.type VMMemoryRaw struct {- ListingMem uint64 `json:"listingMem"`- ListingMaxMem uint64 `json:"listingMaxmem"`- StatusMem uint64 `json:"statusMem,omitempty"`- StatusFreeMem uint64 `json:"statusFreemem,omitempty"`- StatusMaxMem uint64 `json:"statusMaxmem,omitempty"`- Balloon uint64 `json:"balloon,omitempty"`- BalloonMin uint64 `json:"balloonMin,omitempty"`- MemInfoUsed uint64 `json:"meminfoUsed,omitempty"`- MemInfoFree uint64 `json:"meminfoFree,omitempty"`- MemInfoTotal uint64 `json:"meminfoTotal,omitempty"`- Agent int `json:"agent,omitempty"`- DerivedFromBall bool `json:"derivedFromBalloon,omitempty"`+ ListingMem uint64 `json:"listingMem"`+ ListingMaxMem uint64 `json:"listingMaxmem"`+ StatusMem uint64 `json:"statusMem,omitempty"`+ StatusFreeMem uint64 `json:"statusFreemem,omitempty"`+ StatusMaxMem uint64 `json:"statusMaxmem,omitempty"`+ Balloon uint64 `json:"balloon,omitempty"`+ BalloonMin uint64 `json:"balloonMin,omitempty"`+ MemInfoUsed uint64 `json:"meminfoUsed,omitempty"`+ MemInfoFree uint64 `json:"meminfoFree,omitempty"`+ MemInfoTotal uint64 `json:"meminfoTotal,omitempty"`+ MemInfoAvailable uint64 `json:"meminfoAvailable,omitempty"`+ MemInfoBuffers uint64 `json:"meminfoBuffers,omitempty"`+ MemInfoCached uint64 `json:"meminfoCached,omitempty"`+ MemInfoShared uint64 `json:"meminfoShared,omitempty"`+ Agent int `json:"agent,omitempty"`+ DerivedFromBall bool `json:"derivedFromBalloon,omitempty"`}// GuestMemorySnapshot records the memory calculation for a guest (VM/LXC).diff --git a/internal/monitoring/monitor.go b/internal/monitoring/monitor.goindex f2b8999373..9b3ec41850 100644--- a/internal/monitoring/monitor.go+++ b/internal/monitoring/monitor.go@@ -2527,10 +2527,28 @@ func (m *Monitor) pollVMsAndContainersEfficient(ctx context.Context, instanceNamguestRaw.Balloon = detailedStatus.BalloonguestRaw.BalloonMin = detailedStatus.BalloonMinguestRaw.Agent = detailedStatus.Agent+ memAvailable := uint64(0)if detailedStatus.MemInfo != nil {guestRaw.MemInfoUsed = detailedStatus.MemInfo.UsedguestRaw.MemInfoFree = detailedStatus.MemInfo.FreeguestRaw.MemInfoTotal = detailedStatus.MemInfo.Total+ guestRaw.MemInfoAvailable = detailedStatus.MemInfo.Available+ guestRaw.MemInfoBuffers = detailedStatus.MemInfo.Buffers+ guestRaw.MemInfoCached = detailedStatus.MemInfo.Cached+ guestRaw.MemInfoShared = detailedStatus.MemInfo.Shared++ switch {+ case detailedStatus.MemInfo.Available > 0:+ memAvailable = detailedStatus.MemInfo.Available+ memorySource = "meminfo-available"+ case detailedStatus.MemInfo.Free > 0 ||+ detailedStatus.MemInfo.Buffers > 0 ||+ detailedStatus.MemInfo.Cached > 0:+ memAvailable = detailedStatus.MemInfo.Free ++ detailedStatus.MemInfo.Buffers ++ detailedStatus.MemInfo.Cached+ memorySource = "meminfo-derived"+ }}// Use actual disk I/O values from detailed status@@ -2547,10 +2565,16 @@ func (m *Monitor) pollVMsAndContainersEfficient(ctx context.Context, instanceNamguestRaw.DerivedFromBall = false}- if detailedStatus.FreeMem > 0 && memTotal >= detailedStatus.FreeMem {+ switch {+ case memAvailable > 0:+ if memAvailable > memTotal {+ memAvailable = memTotal+ }+ memUsed = memTotal - memAvailable+ case detailedStatus.FreeMem > 0 && memTotal >= detailedStatus.FreeMem:memUsed = memTotal - detailedStatus.FreeMemmemorySource = "status-freemem"- } else if detailedStatus.Mem > 0 {+ case detailedStatus.Mem > 0:memUsed = detailedStatus.MemmemorySource = "status-mem"}@@ -3180,10 +3204,28 @@ func (m *Monitor) pollVMsWithNodes(ctx context.Context, instanceName string, cliguestRaw.Balloon = status.BalloonguestRaw.BalloonMin = status.BalloonMinguestRaw.Agent = status.Agent+ memAvailable := uint64(0)if status.MemInfo != nil {guestRaw.MemInfoUsed = status.MemInfo.UsedguestRaw.MemInfoFree = status.MemInfo.FreeguestRaw.MemInfoTotal = status.MemInfo.Total+ guestRaw.MemInfoAvailable = status.MemInfo.Available+ guestRaw.MemInfoBuffers = status.MemInfo.Buffers+ guestRaw.MemInfoCached = status.MemInfo.Cached+ guestRaw.MemInfoShared = status.MemInfo.Shared++ switch {+ case status.MemInfo.Available > 0:+ memAvailable = status.MemInfo.Available+ memorySource = "meminfo-available"+ case status.MemInfo.Free > 0 ||+ status.MemInfo.Buffers > 0 ||+ status.MemInfo.Cached > 0:+ memAvailable = status.MemInfo.Free ++ status.MemInfo.Buffers ++ status.MemInfo.Cached+ memorySource = "meminfo-derived"+ }}// Use actual disk I/O values from detailed status@@ -3201,18 +3243,28 @@ func (m *Monitor) pollVMsWithNodes(ctx context.Context, instanceName string, cli}// If we have free memory from guest agent, calculate actual usage- if status.FreeMem > 0 {+ switch {+ case memAvailable > 0:+ if memAvailable > memTotal {+ memAvailable = memTotal+ }+ memUsed = memTotal - memAvailable+ case status.FreeMem > 0:// Guest agent reports free memory, so calculate usedmemUsed = memTotal - status.FreeMemmemorySource = "status-freemem"- } else if status.Mem > 0 {+ case status.Mem > 0:// No guest agent free memory data, but we have actual memory usage// Use the reported memory usage from ProxmoxmemUsed = status.MemmemorySource = "status-mem"- } else {+ default:// No memory data available at all - show 0% usagememUsed = 0+ memorySource = "status-unavailable"+ }+ if memUsed > memTotal {+ memUsed = memTotal}guestIPs, guestIfaces, guestOSName, guestOSVersion := fetchGuestAgentMetadata(ctx, client, instanceName, node.Node, vm.Name, vm.VMID, status)@@ -3456,6 +3508,25 @@ func (m *Monitor) pollVMsWithNodes(ctx context.Context, instanceName string, cli}diskReadRate, diskWriteRate, netInRate, netOutRate := m.rateTracker.CalculateRates(guestID, currentMetrics)+ memTotalBytes := clampToInt64(memTotal)+ memUsedBytes := clampToInt64(memUsed)+ if memTotalBytes > 0 && memUsedBytes > memTotalBytes {+ memUsedBytes = memTotalBytes+ }+ memFreeBytes := memTotalBytes - memUsedBytes+ if memFreeBytes < 0 {+ memFreeBytes = 0+ }+ memory := models.Memory{+ Total: memTotalBytes,+ Used: memUsedBytes,+ Free: memFreeBytes,+ Usage: safePercentage(float64(memUsed), float64(memTotal)),+ }+ if guestRaw.Balloon > 0 {+ memory.Balloon = clampToInt64(guestRaw.Balloon)+ }+modelVM := models.VM{ID: guestID,VMID: vm.VMID,@@ -3466,12 +3537,7 @@ func (m *Monitor) pollVMsWithNodes(ctx context.Context, instanceName string, cliType: "qemu",CPU: cpuUsage, // Already in percentageCPUs: vm.CPUs,- Memory: models.Memory{- Total: int64(memTotal),- Used: int64(memUsed),- Free: int64(memTotal - memUsed),- Usage: safePercentage(float64(memUsed), float64(memTotal)),- },+ Memory: memory,Disk: models.Disk{Total: int64(diskTotal),Used: int64(diskUsed),diff --git a/internal/monitoring/monitor_optimized.go b/internal/monitoring/monitor_optimized.goindex 0c7125d4b4..2e4c99879f 100644--- a/internal/monitoring/monitor_optimized.go+++ b/internal/monitoring/monitor_optimized.go@@ -163,21 +163,51 @@ func (m *Monitor) pollVMsWithNodesOptimized(ctx context.Context, instanceName stguestRaw.Balloon = status.BalloonguestRaw.BalloonMin = status.BalloonMinguestRaw.Agent = status.Agent+ memAvailable := uint64(0)if status.MemInfo != nil {guestRaw.MemInfoUsed = status.MemInfo.UsedguestRaw.MemInfoFree = status.MemInfo.FreeguestRaw.MemInfoTotal = status.MemInfo.Total+ guestRaw.MemInfoAvailable = status.MemInfo.Available+ guestRaw.MemInfoBuffers = status.MemInfo.Buffers+ guestRaw.MemInfoCached = status.MemInfo.Cached+ guestRaw.MemInfoShared = status.MemInfo.Shared++ switch {+ case status.MemInfo.Available > 0:+ memAvailable = status.MemInfo.Available+ memorySource = "meminfo-available"+ case status.MemInfo.Free > 0 ||+ status.MemInfo.Buffers > 0 ||+ status.MemInfo.Cached > 0:+ memAvailable = status.MemInfo.Free ++ status.MemInfo.Buffers ++ status.MemInfo.Cached+ memorySource = "meminfo-derived"+ }}if vmStatus.Balloon > 0 && vmStatus.Balloon < vmStatus.MaxMem {memTotal = vmStatus.BalloonguestRaw.DerivedFromBall = true}- if vmStatus.FreeMem > 0 {+ switch {+ case memAvailable > 0:+ if memAvailable > memTotal {+ memAvailable = memTotal+ }+ memUsed = memTotal - memAvailable+ case vmStatus.FreeMem > 0:memUsed = memTotal - vmStatus.FreeMemmemorySource = "status-freemem"- } else if vmStatus.Mem > 0 {+ case vmStatus.Mem > 0:memUsed = vmStatus.MemmemorySource = "status-mem"+ default:+ memUsed = 0+ memorySource = "status-unavailable"+ }+ if memUsed > memTotal {+ memUsed = memTotal}// Use actual disk I/O values from detailed statusdiskReadBytes = int64(vmStatus.DiskRead)@@ -461,14 +491,23 @@ func (m *Monitor) pollVMsWithNodesOptimized(ctx context.Context, instanceName stdiskStatusReason = "no-status"}+ memTotalBytes := clampToInt64(memTotal)+ memUsedBytes := clampToInt64(memUsed)+ if memTotalBytes > 0 && memUsedBytes > memTotalBytes {+ memUsedBytes = memTotalBytes+ }+ memFreeBytes := memTotalBytes - memUsedBytes+ if memFreeBytes < 0 {+ memFreeBytes = 0+ }memory := models.Memory{- Total: int64(memTotal),- Used: int64(memUsed),- Free: int64(memTotal - memUsed),+ Total: memTotalBytes,+ Used: memUsedBytes,+ Free: memFreeBytes,Usage: safePercentage(float64(memUsed), float64(memTotal)),}- if vmStatus != nil && vmStatus.Balloon > 0 {- memory.Balloon = int64(vmStatus.Balloon)+ if guestRaw.Balloon > 0 {+ memory.Balloon = clampToInt64(guestRaw.Balloon)}// Create VM modeldiff --git a/pkg/proxmox/client.go b/pkg/proxmox/client.goindex 872b3b2d2e..7586011cad 100644--- a/pkg/proxmox/client.go+++ b/pkg/proxmox/client.go@@ -1243,28 +1243,39 @@ type ZFSPoolDevice struct {}// VMStatus represents detailed VM status+// VMMemInfo describes memory statistics reported by the guest agent.+// Proxmox surfaces guest /proc/meminfo values (in bytes). The available+// field is only present on newer agent versions, so we keep the raw+// components to reconstruct it when missing.+type VMMemInfo struct {+ Total uint64 `json:"total,omitempty"`+ Used uint64 `json:"used,omitempty"`+ Free uint64 `json:"free,omitempty"`+ Available uint64 `json:"available,omitempty"`+ Buffers uint64 `json:"buffers,omitempty"`+ Cached uint64 `json:"cached,omitempty"`+ Shared uint64 `json:"shared,omitempty"`+}++// VMStatus represents detailed VM status returned by Proxmox.type VMStatus struct {- Status string `json:"status"`- CPU float64 `json:"cpu"`- CPUs int `json:"cpus"`- Mem uint64 `json:"mem"`- MaxMem uint64 `json:"maxmem"`- Balloon uint64 `json:"balloon"`- BalloonMin uint64 `json:"balloon_min"`- FreeMem uint64 `json:"freemem"`- MemInfo *struct {- Used uint64 `json:"used"`- Free uint64 `json:"free"`- Total uint64 `json:"total"`- } `json:"meminfo,omitempty"`- Disk uint64 `json:"disk"`- MaxDisk uint64 `json:"maxdisk"`- DiskRead uint64 `json:"diskread"`- DiskWrite uint64 `json:"diskwrite"`- NetIn uint64 `json:"netin"`- NetOut uint64 `json:"netout"`- Uptime uint64 `json:"uptime"`- Agent int `json:"agent"`+ Status string `json:"status"`+ CPU float64 `json:"cpu"`+ CPUs int `json:"cpus"`+ Mem uint64 `json:"mem"`+ MaxMem uint64 `json:"maxmem"`+ Balloon uint64 `json:"balloon"`+ BalloonMin uint64 `json:"balloon_min"`+ FreeMem uint64 `json:"freemem"`+ MemInfo *VMMemInfo `json:"meminfo,omitempty"`+ Disk uint64 `json:"disk"`+ MaxDisk uint64 `json:"maxdisk"`+ DiskRead uint64 `json:"diskread"`+ DiskWrite uint64 `json:"diskwrite"`+ NetIn uint64 `json:"netin"`+ NetOut uint64 `json:"netout"`+ Uptime uint64 `json:"uptime"`+ Agent int `json:"agent"`}// GetZFSPoolStatus gets the status of ZFS pools on a node