Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Add SMART temperature collection for physical disks (related to #652)
rcourtman2a79d57f7301
diff --git a/internal/models/models.go b/internal/models/models.goindex 6c6061c798..8a64817c16 100644--- a/internal/models/models.go+++ b/internal/models/models.go@@ -491,6 +491,7 @@ type PhysicalDisk struct {DevPath string `json:"devPath"` // /dev/nvme0n1, /dev/sdaModel string `json:"model"`Serial string `json:"serial"`+ WWN string `json:"wwn"` // World Wide NameType string `json:"type"` // nvme, sata, sasSize int64 `json:"size"` // bytesHealth string `json:"health"` // PASSED, FAILED, UNKNOWN@@ -774,11 +775,13 @@ type Temperature struct {MaxRecorded time.Time `json:"maxRecorded,omitempty"` // When maximum temperature was recordedCores []CoreTemp `json:"cores,omitempty"` // Individual core temperaturesGPU []GPUTemp `json:"gpu,omitempty"` // GPU temperatures- NVMe []NVMeTemp `json:"nvme,omitempty"` // NVMe drive temperatures+ NVMe []NVMeTemp `json:"nvme,omitempty"` // NVMe drive temperatures (legacy, from sensor proxy)+ SMART []DiskTemp `json:"smart,omitempty"` // Physical disk temperatures from SMART dataAvailable bool `json:"available"` // Whether any temperature data is availableHasCPU bool `json:"hasCPU"` // Whether CPU temperature data is availableHasGPU bool `json:"hasGPU"` // Whether GPU temperature data is availableHasNVMe bool `json:"hasNVMe"` // Whether NVMe temperature data is available+ HasSMART bool `json:"hasSMART"` // Whether SMART disk temperature data is availableLastUpdate time.Time `json:"lastUpdate"` // When this data was collected}@@ -802,6 +805,18 @@ type NVMeTemp struct {Temp float64 `json:"temp"`}+// DiskTemp represents a physical disk temperature from SMART data+type DiskTemp struct {+ Device string `json:"device"` // Device path (e.g., /dev/sda)+ Serial string `json:"serial,omitempty"` // Disk serial number+ WWN string `json:"wwn,omitempty"` // World Wide Name+ Model string `json:"model,omitempty"` // Disk model+ Type string `json:"type,omitempty"` // Transport type (sata, sas, nvme)+ Temperature int `json:"temperature"` // Temperature in Celsius+ LastUpdated time.Time `json:"lastUpdated"` // When this reading was taken+ StandbySkipped bool `json:"standbySkipped,omitempty"` // True if disk was in standby and not queried+}+// Metric represents a time-series metrictype Metric struct {Timestamp time.Time `json:"timestamp"`diff --git a/internal/monitoring/monitor.go b/internal/monitoring/monitor.goindex 86b53f187d..f2ef55fffe 100644--- a/internal/monitoring/monitor.go+++ b/internal/monitoring/monitor.go@@ -121,31 +121,104 @@ func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) [return disks}+ // Build temperature maps by node for both SMART and legacy NVMe data+ smartTempsByNode := make(map[string][]models.DiskTemp)nvmeTempsByNode := make(map[string][]models.NVMeTemp)+for _, node := range nodes {- if node.Temperature == nil || !node.Temperature.Available || len(node.Temperature.NVMe) == 0 {+ if node.Temperature == nil || !node.Temperature.Available {continue}- temps := make([]models.NVMeTemp, len(node.Temperature.NVMe))- copy(temps, node.Temperature.NVMe)- sort.Slice(temps, func(i, j int) bool {- return temps[i].Device < temps[j].Device- })+ // Collect SMART temps (preferred source)+ if len(node.Temperature.SMART) > 0 {+ temps := make([]models.DiskTemp, len(node.Temperature.SMART))+ copy(temps, node.Temperature.SMART)+ smartTempsByNode[node.Name] = temps+ }- nvmeTempsByNode[node.Name] = temps+ // Collect legacy NVMe temps as fallback+ if len(node.Temperature.NVMe) > 0 {+ temps := make([]models.NVMeTemp, len(node.Temperature.NVMe))+ copy(temps, node.Temperature.NVMe)+ sort.Slice(temps, func(i, j int) bool {+ return temps[i].Device < temps[j].Device+ })+ nvmeTempsByNode[node.Name] = temps+ }}- if len(nvmeTempsByNode) == 0 {+ if len(smartTempsByNode) == 0 && len(nvmeTempsByNode) == 0 {return disks}updated := make([]models.PhysicalDisk, len(disks))copy(updated, disks)+ // Process SMART temperatures first (preferred method)+ for i := range updated {+ smartTemps, ok := smartTempsByNode[updated[i].Node]+ if !ok || len(smartTemps) == 0 {+ continue+ }++ // Try to match by WWN (most reliable)+ if updated[i].WWN != "" {+ for _, temp := range smartTemps {+ if temp.WWN != "" && strings.EqualFold(temp.WWN, updated[i].WWN) {+ if temp.Temperature > 0 && !temp.StandbySkipped {+ updated[i].Temperature = temp.Temperature+ log.Debug().+ Str("disk", updated[i].DevPath).+ Str("wwn", updated[i].WWN).+ Int("temp", temp.Temperature).+ Msg("Matched SMART temperature by WWN")+ }+ continue+ }+ }+ }++ // Fall back to serial number match (case-insensitive)+ if updated[i].Serial != "" && updated[i].Temperature == 0 {+ for _, temp := range smartTemps {+ if temp.Serial != "" && strings.EqualFold(temp.Serial, updated[i].Serial) {+ if temp.Temperature > 0 && !temp.StandbySkipped {+ updated[i].Temperature = temp.Temperature+ log.Debug().+ Str("disk", updated[i].DevPath).+ Str("serial", updated[i].Serial).+ Int("temp", temp.Temperature).+ Msg("Matched SMART temperature by serial")+ }+ continue+ }+ }+ }++ // Last resort: match by device path (normalized)+ if updated[i].Temperature == 0 {+ normalizedDevPath := strings.TrimPrefix(updated[i].DevPath, "/dev/")+ for _, temp := range smartTemps {+ normalizedTempDev := strings.TrimPrefix(temp.Device, "/dev/")+ if normalizedTempDev == normalizedDevPath {+ if temp.Temperature > 0 && !temp.StandbySkipped {+ updated[i].Temperature = temp.Temperature+ log.Debug().+ Str("disk", updated[i].DevPath).+ Int("temp", temp.Temperature).+ Msg("Matched SMART temperature by device path")+ }+ break+ }+ }+ }+ }++ // Process legacy NVMe temperatures for disks that didn't get SMART datadisksByNode := make(map[string][]int)for i := range updated {- if strings.EqualFold(updated[i].Type, "nvme") {+ if strings.EqualFold(updated[i].Type, "nvme") && updated[i].Temperature == 0 {disksByNode[updated[i].Node] = append(disksByNode[updated[i].Node], i)}}@@ -153,9 +226,6 @@ func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) [for nodeName, diskIndexes := range disksByNode {temps, ok := nvmeTempsByNode[nodeName]if !ok || len(temps) == 0 {- for _, idx := range diskIndexes {- updated[idx].Temperature = 0- }continue}@@ -163,10 +233,6 @@ func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) [return updated[diskIndexes[i]].DevPath < updated[diskIndexes[j]].DevPath})- for _, idx := range diskIndexes {- updated[idx].Temperature = 0- }-for idx, diskIdx := range diskIndexes {if idx >= len(temps) {break@@ -178,6 +244,10 @@ func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) [}updated[diskIdx].Temperature = int(math.Round(tempVal))+ log.Debug().+ Str("disk", updated[diskIdx].DevPath).+ Int("temp", updated[diskIdx].Temperature).+ Msg("Matched legacy NVMe temperature by index")}}@@ -5787,6 +5857,7 @@ func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, clieDevPath: disk.DevPath,Model: disk.Model,Serial: disk.Serial,+ WWN: disk.WWN,Type: disk.Type,Size: disk.Size,Health: disk.Health,diff --git a/internal/monitoring/temperature.go b/internal/monitoring/temperature.goindex 241d17854a..83dd5d2260 100644--- a/internal/monitoring/temperature.go+++ b/internal/monitoring/temperature.go@@ -302,32 +302,41 @@ func (tc *TemperatureCollector) disableLegacySSHOnAuthFailure(err error, nodeNamreturn true}-// parseSensorsJSON parses the JSON output from `sensors -j`+// parseSensorsJSON parses the JSON output from the sensor wrapperfunc (tc *TemperatureCollector) parseSensorsJSON(jsonStr string) (*models.Temperature, error) {if strings.TrimSpace(jsonStr) == "" {return nil, fmt.Errorf("empty sensors output")}- // sensors -j output structure:- // {- // "coretemp-isa-0000": {- // "Package id 0": {"temp1_input": 45.0},- // "Core 0": {"temp2_input": 43.0},- // ...- // },- // "nvme-pci-0400": {- // "Composite": {"temp1_input": 38.9}- // }- // }+ // Try to parse as wrapper format first: {sensors: {...}, smart: [...]}+ // Fall back to legacy format for backward compatibility+ var wrapperData struct {+ Sensors map[string]interface{} `json:"sensors"`+ SMART []models.DiskTemp `json:"smart"`+ }var sensorsData map[string]interface{}- if err := json.Unmarshal([]byte(jsonStr), &sensorsData); err != nil {- return nil, fmt.Errorf("failed to parse sensors JSON: %w", err)+ var smartData []models.DiskTemp++ if err := json.Unmarshal([]byte(jsonStr), &wrapperData); err == nil && wrapperData.Sensors != nil {+ // New wrapper format+ sensorsData = wrapperData.Sensors+ smartData = wrapperData.SMART+ log.Debug().+ Int("smartDisks", len(smartData)).+ Msg("Parsed new wrapper format with SMART data")+ } else {+ // Legacy format: direct sensors -j output+ if err := json.Unmarshal([]byte(jsonStr), &sensorsData); err != nil {+ return nil, fmt.Errorf("failed to parse sensors JSON: %w", err)+ }+ log.Debug().Msg("Parsed legacy sensors format (no SMART data)")}temp := &models.Temperature{Cores: []models.CoreTemp{},NVMe: []models.NVMeTemp{},+ SMART: smartData,}foundCPUChip := false@@ -405,9 +414,10 @@ func (tc *TemperatureCollector) parseSensorsJSON(jsonStr string) (*models.Tempertemp.HasCPU = foundCPUChiptemp.HasNVMe = len(temp.NVMe) > 0temp.HasGPU = len(temp.GPU) > 0+ temp.HasSMART = len(temp.SMART) > 0// Available means any temperature data exists (backward compatibility)- temp.Available = temp.HasCPU || temp.HasNVMe || temp.HasGPU+ temp.Available = temp.HasCPU || temp.HasNVMe || temp.HasGPU || temp.HasSMART// Log summary of what was detectedif !foundCPUChip {@@ -424,11 +434,13 @@ func (tc *TemperatureCollector) parseSensorsJSON(jsonStr string) (*models.TemperBool("hasCPU", temp.HasCPU).Bool("hasNVMe", temp.HasNVMe).Bool("hasGPU", temp.HasGPU).+ Bool("hasSMART", temp.HasSMART).Float64("cpuPackage", temp.CPUPackage).Float64("cpuMax", temp.CPUMax).Int("coreCount", len(temp.Cores)).Int("nvmeCount", len(temp.NVMe)).Int("gpuCount", len(temp.GPU)).+ Int("smartCount", len(temp.SMART)).Msg("Temperature data parsed successfully")}diff --git a/scripts/install-sensor-proxy.sh b/scripts/install-sensor-proxy.shindex 29cde817bb..df2401b70b 100755--- a/scripts/install-sensor-proxy.sh+++ b/scripts/install-sensor-proxy.sh@@ -61,6 +61,7 @@ configure_local_authorized_key() {}BINARY_PATH="/usr/local/bin/pulse-sensor-proxy"+WRAPPER_SCRIPT="/usr/local/bin/pulse-sensor-wrapper.sh"SERVICE_PATH="/etc/systemd/system/pulse-sensor-proxy.service"RUNTIME_DIR="/run/pulse-sensor-proxy"SOCKET_PATH="${RUNTIME_DIR}/pulse-sensor-proxy.sock"@@ -783,6 +784,165 @@ fiprint_info "Socket ready at $SOCKET_PATH"+# Install sensor wrapper script for combined sensor and SMART data collection+print_info "Installing sensor wrapper script..."+cat > "$WRAPPER_SCRIPT" << 'WRAPPER_EOF'+#!/bin/bash+#+# pulse-sensor-wrapper.sh+# Combined sensor and SMART temperature collection for Pulse monitoring+#+# This script is deployed as the SSH forced command for the sensor proxy.+# It collects CPU/GPU temps via sensors and disk temps via smartctl,+# returning a unified JSON payload.++set -euo pipefail++# Configuration+CACHE_DIR="/var/cache/pulse-sensor-proxy"+SMART_CACHE_TTL=1800 # 30 minutes+MAX_SMARTCTL_TIME=5 # seconds per disk++# Ensure cache directory exists+mkdir -p "$CACHE_DIR" 2>/dev/null || true++# Function to get cached SMART data+get_cached_smart() {+ local cache_file="$CACHE_DIR/smart-temps.json"+ local now=$(date +%s)++ # Check if cache exists and is fresh+ if [[ -f "$cache_file" ]]; then+ local mtime=$(stat -c %Y "$cache_file" 2>/dev/null || echo 0)+ local age=$((now - mtime))++ if [[ $age -lt $SMART_CACHE_TTL ]]; then+ cat "$cache_file"+ return 0+ fi+ fi++ # Cache miss or stale - return empty array and trigger background refresh+ echo "[]"++ # Trigger async refresh if not already running+ if ! pgrep -f "pulse-sensor-wrapper-refresh" >/dev/null 2>&1; then+ (refresh_smart_cache &)+ fi++ return 0+}++# Function to refresh SMART cache in background+refresh_smart_cache() {+ # Mark this process for detection+ exec -a pulse-sensor-wrapper-refresh bash++ local cache_file="$CACHE_DIR/smart-temps.json"+ local temp_file="${cache_file}.tmp.$$"+ local disks=()++ # Find all physical disks (skip partitions, loop devices, etc.)+ while IFS= read -r dev; do+ [[ -b "$dev" ]] && disks+=("$dev")+ done < <(lsblk -nd -o NAME,TYPE | awk '$2=="disk" {print "/dev/"$1}')++ local results=()++ for dev in "${disks[@]}"; do+ # Use smartctl with standby check to avoid waking sleeping drives+ # -n standby: skip if drive is in standby/sleep mode+ # --json=o: output original smartctl JSON format+ # timeout: prevent hanging on problematic drives++ local output+ if output=$(timeout ${MAX_SMARTCTL_TIME}s smartctl -n standby,after -A --json=o "$dev" 2>/dev/null); then+ # Parse the JSON output+ local temp=$(echo "$output" | jq -r '+ .temperature.current //+ (.ata_smart_attributes.table[] | select(.id == 194) | .raw.value) //+ (.nvme_smart_health_information_log.temperature // empty)+ ' 2>/dev/null)++ local serial=$(echo "$output" | jq -r '.serial_number // empty' 2>/dev/null)+ local wwn=$(echo "$output" | jq -r '.wwn.naa // .wwn.oui // empty' 2>/dev/null)+ local model=$(echo "$output" | jq -r '.model_name // .model_family // empty' 2>/dev/null)+ local transport=$(echo "$output" | jq -r '.device.type // empty' 2>/dev/null)++ # Only include if we got a valid temperature+ if [[ -n "$temp" && "$temp" != "null" && "$temp" =~ ^[0-9]+$ ]]; then+ local entry=$(jq -n \+ --arg dev "$dev" \+ --arg serial "$serial" \+ --arg wwn "$wwn" \+ --arg model "$model" \+ --arg transport "$transport" \+ --argjson temp "$temp" \+ --arg updated "$(date -Iseconds)" \+ '{+ device: $dev,+ serial: $serial,+ wwn: $wwn,+ model: $model,+ type: $transport,+ temperature: $temp,+ lastUpdated: $updated,+ standbySkipped: false+ }')+ results+=("$entry")+ fi+ elif echo "$output" | grep -q "standby"; then+ # Drive is in standby - record it but don't wake it+ local entry=$(jq -n \+ --arg dev "$dev" \+ --arg updated "$(date -Iseconds)" \+ '{+ device: $dev,+ temperature: null,+ lastUpdated: $updated,+ standbySkipped: true+ }')+ results+=("$entry")+ fi++ # Small delay between disks to avoid saturating SATA controller+ sleep 0.1+ done++ # Build final JSON array+ if [[ ${#results[@]} -gt 0 ]]; then+ local json=$(printf '%s\n' "${results[@]}" | jq -s '.')+ else+ local json="[]"+ fi++ # Atomic write to cache+ echo "$json" > "$temp_file"+ mv "$temp_file" "$cache_file"+ chmod 644 "$cache_file" 2>/dev/null || true+}++# Main execution++# Collect sensor data (CPU, GPU temps)+sensors_data=$(sensors -j 2>/dev/null || echo '{}')++# Get SMART data from cache+smart_data=$(get_cached_smart)++# Combine into unified payload+jq -n \+ --argjson sensors "$sensors_data" \+ --argjson smart "$smart_data" \+ '{+ sensors: $sensors,+ smart: $smart+ }'+WRAPPER_EOF++chmod +x "$WRAPPER_SCRIPT"+print_success "Sensor wrapper installed at $WRAPPER_SCRIPT"+# Install cleanup system for automatic SSH key removal when nodes are deletedprint_info "Installing cleanup system..."@@ -1022,7 +1182,7 @@ if command -v pvecm >/dev/null 2>&1; thenprint_info "Discovered cluster nodes: $(echo $CLUSTER_NODES | tr '\n' ' ')"# Configure SSH key with forced command restriction- FORCED_CMD='command="sensors -j",no-port-forwarding,no-X11-forwarding,no-agent-forwarding,no-pty'+ FORCED_CMD='command="/usr/local/bin/pulse-sensor-wrapper.sh",no-port-forwarding,no-X11-forwarding,no-agent-forwarding,no-pty'AUTH_LINE="${FORCED_CMD} ${PROXY_PUBLIC_KEY} # pulse-managed-key"# Track SSH key push results@@ -1099,7 +1259,7 @@ if command -v pvecm >/dev/null 2>&1; thenprint_info "No cluster detected, configuring standalone node..."# Configure SSH key with forced command restriction- FORCED_CMD='command="sensors -j",no-port-forwarding,no-X11-forwarding,no-agent-forwarding,no-pty'+ FORCED_CMD='command="/usr/local/bin/pulse-sensor-wrapper.sh",no-port-forwarding,no-X11-forwarding,no-agent-forwarding,no-pty'AUTH_LINE="${FORCED_CMD} ${PROXY_PUBLIC_KEY} # pulse-managed-key"print_info "Authorizing proxy key on localhost..."@@ -1113,7 +1273,7 @@ elseprint_info "Configuring SSH key for localhost..."# Configure localhost as fallback- FORCED_CMD='command="sensors -j",no-port-forwarding,no-X11-forwarding,no-agent-forwarding,no-pty'+ FORCED_CMD='command="/usr/local/bin/pulse-sensor-wrapper.sh",no-port-forwarding,no-X11-forwarding,no-agent-forwarding,no-pty'AUTH_LINE="${FORCED_CMD} ${PROXY_PUBLIC_KEY} # pulse-managed-key"configure_local_authorized_key "$AUTH_LINE"