Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Handle AMD Tctl temperature readings (refs #586)
rcourtman30879c3b7bb5
diff --git a/internal/monitoring/temperature.go b/internal/monitoring/temperature.goindex 256ef9fffd..0a921c7e50 100644--- a/internal/monitoring/temperature.go+++ b/internal/monitoring/temperature.go@@ -297,11 +297,18 @@ func (tc *TemperatureCollector) parseCPUTemps(chipMap map[string]interface{}, tecontinue}- // Look for Package id (Intel) or Tdie (AMD)- if strings.Contains(sensorName, "Package id") || strings.Contains(sensorName, "Tdie") {+ sensorNameLower := strings.ToLower(sensorName)++ // Look for Package id (Intel) or Tdie/Tctl (AMD control loop temperature)+ if strings.Contains(sensorName, "Package id") ||+ strings.Contains(sensorName, "Tdie") ||+ strings.Contains(sensorNameLower, "tctl") {if tempVal := extractTempInput(sensorMap); !math.IsNaN(tempVal) {temp.CPUPackage = tempValfoundPackageTemp = true+ if tempVal > temp.CPUMax {+ temp.CPUMax = tempVal+ }}}diff --git a/internal/monitoring/temperature_test.go b/internal/monitoring/temperature_test.goindex d2d58ebc30..5712f6b5f0 100644--- a/internal/monitoring/temperature_test.go+++ b/internal/monitoring/temperature_test.go@@ -133,6 +133,36 @@ func TestParseSensorsJSON_WithCpuAndNvmeData(t *testing.T) {}}+func TestParseSensorsJSON_WithAmdTctlOnly(t *testing.T) {+ collector := &TemperatureCollector{}++ jsonStr := `{+ "k10temp-pci-00c3": {+ "Tctl": {"temp1_input": 55.4}+ }+ }`++ temp, err := collector.parseSensorsJSON(jsonStr)+ if err != nil {+ t.Fatalf("unexpected error parsing sensors output: %v", err)+ }+ if temp == nil {+ t.Fatalf("expected temperature struct, got nil")+ }+ if !temp.Available {+ t.Fatalf("expected temperature to be available when Tctl reading present")+ }+ if !temp.HasCPU {+ t.Fatalf("expected HasCPU to be true when AMD Tctl is present")+ }+ if temp.CPUPackage != 55.4 {+ t.Fatalf("expected cpu package temperature 55.4, got %.2f", temp.CPUPackage)+ }+ if temp.CPUMax != 55.4 {+ t.Fatalf("expected cpu max temperature to follow Tctl value, got %.2f", temp.CPUMax)+ }+}+func TestParseSensorsJSON_RPiWrapper(t *testing.T) {collector := &TemperatureCollector{}