Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
fix(alerts): confirm physical-disk wearout recovery
pulse-triage[bot]322e5f04d24c
diff --git a/docs/release-control/v6/internal/subsystems/alerts.md b/docs/release-control/v6/internal/subsystems/alerts.mdindex 549454680e..c3d2879a0f 100644--- a/docs/release-control/v6/internal/subsystems/alerts.md+++ b/docs/release-control/v6/internal/subsystems/alerts.md@@ -279,6 +279,17 @@ own inline boundary. A wearout arm keyed on `> 0` silently exempts the singleworst reading a disk can publish, which let a spent SSD read critical on thePhysical Disks surface while raising no alert at all.+Proxmox wearout recovery requires three consecutive reported readings of at+least 10% remaining life. An absent reading does not prove recovery, and a+new low reading resets the recovery run; until recovery is confirmed the+existing alert retains its low-life value and occurrence. This bounds the+resolved-then-refired notification loop when endurance data briefly looks+healthy (#2112), while a sustained replacement/corrected reading can still+resolve. `TestCheckDiskHealthWearoutFlappingDoesNotRepeatNotifications` and+`TestCheckDiskHealthWearoutRecoveryAlertCleared` pin dispatch/history+deduplication and confirmed recovery. This is synthetic source proof, not a+claim that the reporter's installed image has been repaired.+Host SMART counter growth is an event boundary rather than a warning on everyhistorical non-zero value. For an agent-only disk, the first reported UDMA CRCerror count establishes an in-memory baseline and raises no alert. A laterdiff --git a/internal/alerts/alerts_test.go b/internal/alerts/alerts_test.goindex 9de3a49844..7e78fb8377 100644--- a/internal/alerts/alerts_test.go+++ b/internal/alerts/alerts_test.go@@ -4322,6 +4322,12 @@ func TestCheckDiskHealthWearoutRecoveryAlertCleared(t *testing.T) {// Wearout recovers (replaced drive, or misread corrected)disk.Wearout = 95+ for range 2 {+ m.CheckDiskHealth("test-instance", "pve-node1", disk)+ if !testHasActiveAlert(t, m, wearoutAlertID) {+ t.Fatal("wearout alert resolved on an unconfirmed recovery reading")+ }+ }m.CheckDiskHealth("test-instance", "pve-node1", disk)m.mu.RLock()diff --git a/internal/alerts/canonical_lifecycle.go b/internal/alerts/canonical_lifecycle.goindex 3a36d3f60b..d1c8e738b5 100644--- a/internal/alerts/canonical_lifecycle.go+++ b/internal/alerts/canonical_lifecycle.go@@ -40,6 +40,7 @@ type canonicalLifecycleAlertParams struct {type canonicalStatefulAlertParams struct {Spec alertspecs.ResourceAlertSpecEvidence alertspecs.AlertEvidence+ RecoveryConfirmations intAlertID stringAlertType stringResourceID string@@ -675,8 +676,9 @@ func (m *Manager) evaluateCanonicalStatefulAlert(params canonicalStatefulAlertPaSeverity: severity,ObservedAt: params.Evidence.ObservedAt,}, reducer.DiscreteRule{- Confirmations: specConfirmationsRequired(params.Spec),- Disabled: params.Spec.Disabled,+ Confirmations: specConfirmationsRequired(params.Spec),+ RecoveryConfirmations: params.RecoveryConfirmations,+ Disabled: params.Spec.Disabled,})primary := reducer.EventType("")if len(events) > 0 {@@ -722,6 +724,12 @@ func (m *Manager) evaluateCanonicalStatefulAlert(params canonicalStatefulAlertParesult.State.ConsecutiveMatches = incident.Confirmationsresult.State.FirstMatchedAt = incident.StartedAtresult.State.ActiveSince = incident.StartedAt+ // A recovery still inside its confirmation window is not new failing+ // evidence. Keep the previous alert value and message rather than+ // projecting a healthy reading onto a still-active warning.+ if !matched {+ return result, true+ }switch {case existing == nil:result.Transition = transition(alertspecs.EvaluationTransitionActivated, alertspecs.AlertStatePending, alertspecs.AlertStateFiring)diff --git a/internal/alerts/canonical_stateful_test.go b/internal/alerts/canonical_stateful_test.goindex 8bf50a00e3..8f7f41e9aa 100644--- a/internal/alerts/canonical_stateful_test.go+++ b/internal/alerts/canonical_stateful_test.go@@ -9,6 +9,7 @@ import ("github.com/rcourtman/pulse-go-rewrite/internal/models""github.com/rcourtman/pulse-go-rewrite/internal/storagehealth""github.com/rcourtman/pulse-go-rewrite/internal/unifiedresources"+ "github.com/rcourtman/pulse-go-rewrite/pkg/proxmox")func TestCanonicalLifecycleCopiesValidatedAlertCorrelation(t *testing.T) {@@ -323,3 +324,72 @@ func TestHealthAssessmentEscalationDelivery(t *testing.T) {t.Fatalf("rate-limited incident failed to update: %v", a.Level)}}++// A single optimistic endurance reading must not close a still-worn disk's+// occurrence. Otherwise the next physical-disk poll fires and notifies again,+// as reported in #2112 after the host-agent SMART merge correction shipped.+func TestCheckDiskHealthWearoutFlappingDoesNotRepeatNotifications(t *testing.T) {+ m := newEventLogManager(t)+ m.SetAlertCallback(func(*Alert) {})+ disk := proxmox.Disk{+ DevPath: "/dev/sda", Model: "KINGSTON SA400", Serial: "stable-serial",+ Type: "ssd", Health: "PASSED", Wearout: 0,+ }+ check := func(wearout int) {+ disk.Wearout = wearout+ m.CheckDiskHealth("pve", "rocket", disk)+ }++ check(0)+ active := m.GetActiveAlerts()+ if len(active) != 1 || active[0].Type != "disk-wearout" {+ t.Fatalf("spent SSD did not open its wearout alert: %+v", active)+ }+ initialID := active[0].ID+ for range 12 {+ check(100) // intermittent healthy-looking reading+ if held := m.GetActiveAlerts(); len(held) != 1 || held[0].Value != 0 || held[0].Message != active[0].Message {+ t.Fatalf("unconfirmed recovery rewrote the worn-disk warning: %+v", held)+ }+ check(0) // unchanged worn drive on the next poll+ }+ active = m.GetActiveAlerts()+ if len(active) != 1 || active[0].ID != initialID || active[0].Value != 0 {+ t.Fatalf("flapping reading changed the worn disk occurrence: %+v", active)+ }+ if got := len(m.historyManager.GetAllHistory(100)); got != 1 {+ t.Fatalf("flapping produced %d history entries, want one", got)+ }+ if got := len(queryAlertEvents(t, m, eventlog.Filter{Types: []string{eventlog.TypeNotificationDispatched}})); got != 1 {+ t.Fatalf("flapping produced %d dispatches, want one", got)+ }+ if got := len(m.GetRecentlyResolved()); got != 0 {+ t.Fatalf("flapping produced %d resolved occurrences, want none", got)+ }+ check(-1)+ if got := len(m.GetActiveAlerts()); got != 1 {+ t.Fatalf("unreported wearout incorrectly proved recovery: %d active", got)+ }++ // A genuinely sustained high reading still resolves; this is a recovery+ // confirmation, not a permanent wearout-alert latch.+ check(100)+ check(100)+ if got := len(m.GetActiveAlerts()); got != 1 {+ t.Fatalf("alert recovered before the third healthy reading: %d", got)+ }+ check(100)+ if got := len(m.GetActiveAlerts()); got != 0 {+ t.Fatalf("alert did not recover after three healthy readings: %d", got)+ }+ if got := len(m.GetRecentlyResolved()); got != 1 {+ t.Fatalf("sustained recovery produced %d resolved occurrences, want one", got)+ }+ check(0)+ if got := len(m.GetActiveAlerts()); got != 1 {+ t.Fatalf("new low-life reading after confirmed recovery did not alert: %d", got)+ }+ if got := len(queryAlertEvents(t, m, eventlog.Filter{Types: []string{eventlog.TypeNotificationDispatched}})); got != 2 {+ t.Fatalf("genuine recurrence produced %d total dispatches, want two", got)+ }+}diff --git a/internal/alerts/disk_health.go b/internal/alerts/disk_health.goindex eea484d24c..db41da7cb3 100644--- a/internal/alerts/disk_health.go+++ b/internal/alerts/disk_health.go@@ -36,7 +36,6 @@ func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {canonicalResourceID := proxmoxDiskCanonicalResourceID(instance, node, disk.DevPath)resourceType := unifiedresources.ResourceType("proxmox-disk")canonicalHealthAlertID := buildCanonicalStateID(canonicalResourceID, canonicalResourceID+"-health")- canonicalWearoutAlertID := buildCanonicalStateID(canonicalResourceID, canonicalResourceID+"-wearout")clearDiskAlert := func(ids ...string) {seen := make(map[string]struct{}, len(ids))@@ -119,11 +118,10 @@ func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {clearDiskAlert(alertID, canonicalHealthAlertID)}- // Check for low wearout (SSD life remaining). Gate on the same predicate- // the risk assessment uses so a disk cannot read critical in the UI while- // staying silent here: 0 from an SSD means no endurance left and must- // alert, while -1 and a rotational 0 are absent evidence.- if storagehealth.WearoutReported(disk.Wearout, disk.Type) && disk.Wearout < 10 {+ // Check wearout only when the disk reports endurance. Unknown readings+ // cannot prove recovery; 0 from an SSD is a real, fully spent reading,+ // whereas -1 and rotational 0 are absent evidence.+ if storagehealth.WearoutReported(disk.Wearout, disk.Type) {message := fmt.Sprintf("SSD has less than 10%% life remaining (%d%% wearout)", disk.Wearout)spec, err := buildCanonicalSeverityThresholdSpecWithDirection(canonicalResourceID+"-wearout", canonicalResourceID, resourceName, resourceType, "wearout-remaining", alertspecs.ThresholdDirectionBelow, 10, 0, false)if err != nil {@@ -138,6 +136,10 @@ func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {_, _ = m.evaluateCanonicalStatefulAlert(canonicalStatefulAlertParams{Spec: spec,+ // Endurance cannot normally improve on the same disk. Require+ // sustained healthy-looking polls before resolving a worn-disk+ // occurrence; a new low reading resets the recovery run (#2112).+ RecoveryConfirmations: 3,Evidence: alertspecs.AlertEvidence{ObservedAt: time.Now(),SeverityThreshold: &alertspecs.SeverityThresholdEvidence{@@ -160,15 +162,14 @@ func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {AddToHistory: true,})- log.Warn().- Str("node", node).- Str("disk", disk.DevPath).- Str("model", disk.Model).- Int("wearout", disk.Wearout).- Msg("Disk wearout alert created")+ if disk.Wearout < 10 {+ log.Warn().+ Str("node", node).+ Str("disk", disk.DevPath).+ Str("model", disk.Model).+ Int("wearout", disk.Wearout).+ Msg("Disk wearout alert observed")+ }}- } else if disk.Wearout >= 10 {- // Wearout is acceptable, clear alert if it exists- clearDiskAlert(wearoutAlertID, canonicalWearoutAlertID)}}