Skip to content

armgit / Pulse

Public Imported from GitHub
0

Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.

Seed disk temperature type defaults

rcourtman3cecf9576d39
diff --git a/internal/alerts/default_config.go b/internal/alerts/default_config.go
index cbae0e30f2..28f1bcf7b2 100644
--- a/internal/alerts/default_config.go
+++ b/internal/alerts/default_config.go
@@ -82,6 +82,11 @@ func defaultAlertConfig() AlertConfig {
"sata": {Trigger: 90, Clear: 85},
"hdd": {Trigger: 85, Clear: 80},
},
+ DiskTempByType: map[string]HysteresisThreshold{
+ "nvme": {Trigger: 70, Clear: 65},
+ "sas": {Trigger: 65, Clear: 60},
+ "sata": {Trigger: 55, Clear: 50},
+ },
MinimumDelta: 2.0, // 2% minimum change
SuppressionWindow: 5, // 5 minutes
HysteresisMargin: 5.0, // 5% default margin
diff --git a/internal/alerts/default_normalization_test.go b/internal/alerts/default_normalization_test.go
index 89f30fe605..852db656db 100644
--- a/internal/alerts/default_normalization_test.go
+++ b/internal/alerts/default_normalization_test.go
@@ -395,3 +395,22 @@ func TestNormalizeDiskTempByType(t *testing.T) {
}
})
}
+
+func TestDefaultAlertConfigSeedsDiskTempByType(t *testing.T) {
+ cfg := defaultAlertConfig()
+ if cfg.DiskTempByType == nil {
+ t.Fatal("expected defaultAlertConfig to seed DiskTempByType, got nil")
+ }
+ if nvme, ok := cfg.DiskTempByType["nvme"]; !ok || nvme.Trigger != 70 || nvme.Clear != 65 {
+ t.Fatalf("nvme = %+v ok=%v, want {Trigger:70 Clear:65}", nvme, ok)
+ }
+ if sas, ok := cfg.DiskTempByType["sas"]; !ok || sas.Trigger != 65 || sas.Clear != 60 {
+ t.Fatalf("sas = %+v ok=%v, want {Trigger:65 Clear:60}", sas, ok)
+ }
+ if sata, ok := cfg.DiskTempByType["sata"]; !ok || sata.Trigger != 55 || sata.Clear != 50 {
+ t.Fatalf("sata = %+v ok=%v, want {Trigger:55 Clear:50}", sata, ok)
+ }
+ if _, ok := cfg.DiskTempByType["hdd"]; ok {
+ t.Fatalf("hdd key should not be seeded for SMART temperature, map=%+v", cfg.DiskTempByType)
+ }
+}