Skip to content

armgit / Pulse

Public Imported from GitHub
0

Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.

fix(alerts): resolve PVE disk alerts to physical-disk policy

pulse-triage[bot]5817c9515334
diff --git a/docs/release-control/v6/internal/subsystems/alerts.md b/docs/release-control/v6/internal/subsystems/alerts.md
index c3d2879a0f..9df72c3422 100644
--- a/docs/release-control/v6/internal/subsystems/alerts.md
+++ b/docs/release-control/v6/internal/subsystems/alerts.md
@@ -1664,6 +1664,18 @@ Proxmox disk health alert evaluation now lives in
identity, disk health assessment alerts, known-firmware health suppression, and
SSD wearout alerts; future Proxmox disk-health behavior should extend that
checker owner rather than expanding the central Manager file.
+PVE disk-health and wearout occurrences retain the existing
+`instance:node:disk:sanitized-device-path` resource reference. The shared
+constructor in unified resources must produce the same identity as the alert
+checker; changing occurrence IDs to match registry source IDs would reopen
+historical incidents and can re-notify a worn disk. The registry resolves this
+reference as an alias of the exact physical disk for operator-state lookups.
+Muting one physical disk therefore resolves its active wearout alert and blocks
+later writes and notifications without muting another disk or changing the
+wearout recovery rules. `TestProxmoxDiskCanonicalResourceIDTrimsIdentity` pins
+the persisted identity shape; monitoring's registry-backed
+`TestProxmoxPhysicalDiskMuteResolvesAndSuppressesWearoutAlert` pins the policy
+path. These are source invariants, not evidence of installed field relief.
Shared metric threshold runtime now lives in
`internal/alerts/metric_runtime.go`. That file owns metric threshold lookup,
per-metric delay and intent resolution, reducer input composition, active-alert
diff --git a/docs/release-control/v6/internal/subsystems/unified-resources.md b/docs/release-control/v6/internal/subsystems/unified-resources.md
index 96831c9796..f54532363e 100644
--- a/docs/release-control/v6/internal/subsystems/unified-resources.md
+++ b/docs/release-control/v6/internal/subsystems/unified-resources.md
@@ -4483,6 +4483,15 @@ Canonical physical-disk views now expose the full disk identity and SMART
metadata needed by monitoring refresh paths, so physical-disk temperature and
SMART merges can run from unified `ReadState` instead of from snapshot-owned
disk arrays.
+For a Proxmox physical disk with a complete instance, node and device path,
+canonical aliases include the persisted PVE disk-alert reference
+`instance:node:disk:sanitized-device-path`. The alert checker and registry use
+one constructor for that legacy reference. It is a lookup alias, never the
+disk's primary canonical ID or source ID, and must not leak across nodes,
+instances or non-disk resources. Ambiguous alias claims still fail closed under
+normal reference resolution. `TestProxmoxDiskAlertAliasIsScopedAndNotPrimaryIdentity`
+pins the identity boundary, and the registry-backed monitoring mute test pins
+its operator-state consumer.
When host-agent SMART and Proxmox physical-disk rows merge, the unified
resource must preserve both the enriched `PhysicalDiskMeta` and the Proxmox
source payload (`ProxmoxData.NodeName`, `Instance`, and source id). A
diff --git a/internal/alerts/alerts_test.go b/internal/alerts/alerts_test.go
index 7e78fb8377..257841ce14 100644
--- a/internal/alerts/alerts_test.go
+++ b/internal/alerts/alerts_test.go
@@ -423,9 +423,18 @@ func TestBuildBackupPVETemplateSubjectKeyTrimsParts(t *testing.T) {
}
func TestProxmoxDiskCanonicalResourceIDTrimsIdentity(t *testing.T) {
- got := proxmoxDiskCanonicalResourceID(" inst ", " node ", "/dev/sda")
- if got != "inst:node:disk:dev-sda" {
- t.Fatalf("proxmoxDiskCanonicalResourceID() = %q, want %q", got, "inst:node:disk:dev-sda")
+ for _, tt := range []struct {
+ name, instance, node, path, want string
+ }{
+ {"trimmed source identity", " inst ", " node ", "/dev/sda", "inst:node:disk:dev-sda"},
+ {"nested device path", "inst", "node", "/dev/disk/by-id/ATA_DISK", "inst:node:disk:dev-disk-by-id-ata-disk"},
+ {"root path", "inst", "node", "/", "inst:node:disk:root"},
+ } {
+ t.Run(tt.name, func(t *testing.T) {
+ if got := proxmoxDiskCanonicalResourceID(tt.instance, tt.node, tt.path); got != tt.want {
+ t.Fatalf("proxmoxDiskCanonicalResourceID() = %q, want %q", got, tt.want)
+ }
+ })
}
}
diff --git a/internal/alerts/disk_health.go b/internal/alerts/disk_health.go
index db41da7cb3..4afe7de5c4 100644
--- a/internal/alerts/disk_health.go
+++ b/internal/alerts/disk_health.go
@@ -13,7 +13,7 @@ import (
)
func proxmoxDiskCanonicalResourceID(instance, node, devPath string) string {
- return fmt.Sprintf("%s:%s:disk:%s", strings.TrimSpace(instance), strings.TrimSpace(node), sanitizeAlertKey(devPath))
+ return unifiedresources.ProxmoxPhysicalDiskAlertResourceID(instance, node, devPath)
}
func proxmoxDiskAlertMetadata(disk proxmox.Disk) map[string]interface{} {
diff --git a/internal/monitoring/monitor_alert_intent_test.go b/internal/monitoring/monitor_alert_intent_test.go
index 71d6fcbddc..6832ec92ce 100644
--- a/internal/monitoring/monitor_alert_intent_test.go
+++ b/internal/monitoring/monitor_alert_intent_test.go
@@ -39,6 +39,59 @@ func TestInstallOperatorIntentResolverProjectsCanonicalResourcePolicy(t *testing
}
}
+func TestProxmoxPhysicalDiskMuteResolvesAndSuppressesWearoutAlert(t *testing.T) {
+ store := unifiedresources.NewMemoryStore()
+ registry := unifiedresources.NewRegistry(store)
+ instance, node := "pve", "rocket"
+ makeDisk := func(path string) models.PhysicalDisk {
+ return models.PhysicalDisk{
+ ID: unifiedresources.ProxmoxPhysicalDiskSourceID(instance, node, path, "", ""),
+ Instance: instance, Node: node, DevPath: path,
+ Model: "KINGSTON SA400", Type: "ssd", Health: "PASSED", Wearout: 0,
+ LastChecked: time.Now().UTC(),
+ }
+ }
+ registry.IngestSnapshot(models.StateSnapshot{
+ PhysicalDisks: []models.PhysicalDisk{makeDisk("/dev/sda"), makeDisk("/dev/sdb")},
+ })
+ diskID := unifiedresources.ProxmoxPhysicalDiskAlertResourceID(instance, node, "/dev/sda")
+ canonicalID, found := registry.ResolveReferenceID(diskID)
+ if !found {
+ t.Fatalf("PVE wearout alert resource %q did not resolve to a physical disk", diskID)
+ }
+ otherID := unifiedresources.ProxmoxPhysicalDiskAlertResourceID(instance, node, "/dev/sdb")
+ if other, ok := registry.ResolveReferenceID(otherID); !ok || other == canonicalID {
+ t.Fatalf("other PVE disk identity = %q, %v; want a different disk", other, ok)
+ }
+
+ manager := alerts.NewManagerWithDataDir(t.TempDir())
+ t.Cleanup(manager.Stop)
+ worn := proxmox.Disk{DevPath: "/dev/sda", Model: "KINGSTON SA400", Type: "ssd", Health: "PASSED", Wearout: 0}
+ manager.CheckDiskHealth(instance, node, worn)
+ if got := len(manager.GetActiveAlerts()); got != 1 {
+ t.Fatalf("unmuted worn disk raised %d alerts, want one", got)
+ }
+ if err := store.SetResourceOperatorState(unifiedresources.ResourceOperatorState{
+ CanonicalID: canonicalID, MonitoringMode: unifiedresources.MonitoringModeMuted,
+ }); err != nil {
+ t.Fatal(err)
+ }
+ monitor := &Monitor{alertManager: manager}
+ monitor.installOperatorIntentResolver(unifiedresources.NewMonitorAdapter(registry))
+ if got := len(manager.GetActiveAlerts()); got != 0 {
+ t.Fatalf("mute left %d existing PVE wearout alerts active", got)
+ }
+ manager.CheckDiskHealth(instance, node, worn)
+ if got := len(manager.GetActiveAlerts()); got != 0 {
+ t.Fatalf("muted PVE disk raised %d new wearout alerts", got)
+ }
+ worn.DevPath = "/dev/sdb"
+ manager.CheckDiskHealth(instance, node, worn)
+ if got := len(manager.GetActiveAlerts()); got != 1 {
+ t.Fatalf("other PVE disk raised %d alerts, want one", got)
+ }
+}
+
func TestInstallOperatorIntentResolverInheritsScopedMaintenanceFromParent(t *testing.T) {
store := unifiedresources.NewMemoryStore()
registry := unifiedresources.NewRegistry(store)
diff --git a/internal/unifiedresources/canonical_identity.go b/internal/unifiedresources/canonical_identity.go
index e86011b9a2..bc89842669 100644
--- a/internal/unifiedresources/canonical_identity.go
+++ b/internal/unifiedresources/canonical_identity.go
@@ -117,6 +117,16 @@ func canonicalAliases(resource Resource, primaryID, platformID, hostname string)
strings.TrimSpace(resource.Proxmox.NodeName),
)
values = append(values, resource.Proxmox.NodeAliases...)
+ // PVE disk alerts predate the unified resource registry and retain a
+ // path-shaped resource reference. Resolve it to this exact physical
+ // disk so a UI mute reaches both new and restored occurrences (#2112).
+ if CanonicalResourceType(resource.Type) == ResourceTypePhysicalDisk && resource.PhysicalDisk != nil &&
+ strings.TrimSpace(resource.Proxmox.Instance) != "" && strings.TrimSpace(resource.Proxmox.NodeName) != "" &&
+ strings.TrimSpace(resource.PhysicalDisk.DevPath) != "" {
+ values = append(values, ProxmoxPhysicalDiskAlertResourceID(
+ resource.Proxmox.Instance, resource.Proxmox.NodeName, resource.PhysicalDisk.DevPath,
+ ))
+ }
}
return uniqueTrimmed(values...)
diff --git a/internal/unifiedresources/canonical_identity_test.go b/internal/unifiedresources/canonical_identity_test.go
index 519de9d994..b99ed9bfae 100644
--- a/internal/unifiedresources/canonical_identity_test.go
+++ b/internal/unifiedresources/canonical_identity_test.go
@@ -143,6 +143,36 @@ func TestRefreshCanonicalIdentityKeepsProxmoxPresentationSeparateFromNativeAlias
}
}
+func TestProxmoxDiskAlertAliasIsScopedAndNotPrimaryIdentity(t *testing.T) {
+ resource := Resource{
+ ID: "physical-disk-1", Type: ResourceTypePhysicalDisk,
+ Proxmox: &ProxmoxData{Instance: "pve-a", NodeName: "node-1"},
+ PhysicalDisk: &PhysicalDiskMeta{DevPath: "/dev/sda"},
+ }
+ assertAlias := func(want string, present bool) {
+ t.Helper()
+ RefreshCanonicalIdentity(&resource)
+ if resource.Canonical == nil || resource.Canonical.PrimaryID != resource.ID {
+ t.Fatalf("disk alert alias changed primary identity: %+v", resource.Canonical)
+ }
+ found := false
+ for _, alias := range resource.Canonical.Aliases {
+ found = found || alias == want
+ }
+ if found != present {
+ t.Fatalf("alias %q present = %v, want %v; aliases = %v", want, found, present, resource.Canonical.Aliases)
+ }
+ }
+
+ alertID := ProxmoxPhysicalDiskAlertResourceID("pve-a", "node-1", "/dev/sda")
+ assertAlias(alertID, true)
+ resource.Proxmox.NodeName = "node-2"
+ assertAlias(alertID, false)
+ assertAlias(ProxmoxPhysicalDiskAlertResourceID("pve-a", "node-2", "/dev/sda"), true)
+ resource.Type = ResourceTypeStorage
+ assertAlias(ProxmoxPhysicalDiskAlertResourceID("pve-a", "node-2", "/dev/sda"), false)
+}
+
func TestUnavailableMemoryFacetsDoNotChangeCanonicalIdentity(t *testing.T) {
total := int64(8 << 30)
resource := Resource{
diff --git a/internal/unifiedresources/physical_disk_ids.go b/internal/unifiedresources/physical_disk_ids.go
index 7e2642d5a7..517a8bb8f2 100644
--- a/internal/unifiedresources/physical_disk_ids.go
+++ b/internal/unifiedresources/physical_disk_ids.go
@@ -64,6 +64,42 @@ func ProxmoxPhysicalDiskSourceID(instance, node, device, controller, target stri
return legacy
}
+// ProxmoxPhysicalDiskAlertResourceID is the persisted resource reference used
+// by PVE disk-health and wearout alerts. Keep this distinct from the disk's
+// source ID: existing alert occurrences use this shape, while the registry
+// needs it as an alias to apply per-disk operator intent.
+func ProxmoxPhysicalDiskAlertResourceID(instance, node, device string) string {
+ return fmt.Sprintf("%s:%s:disk:%s", strings.TrimSpace(instance), strings.TrimSpace(node), physicalDiskAlertKey(device))
+}
+
+func physicalDiskAlertKey(device string) string {
+ trimmed := strings.TrimSpace(device)
+ if trimmed == "/" {
+ return "root"
+ }
+ trimmed = strings.Trim(trimmed, "/\\ ")
+ if trimmed == "" {
+ trimmed = "root"
+ }
+ var builder strings.Builder
+ previousDash := false
+ for _, r := range strings.ToLower(trimmed) {
+ switch {
+ case r >= 'a' && r <= 'z', r >= '0' && r <= '9', r == '.':
+ builder.WriteRune(r)
+ previousDash = false
+ case !previousDash:
+ builder.WriteByte('-')
+ previousDash = true
+ }
+ }
+ key := strings.Trim(builder.String(), "-.")
+ if key == "" {
+ return "disk"
+ }
+ return key
+}
+
func PhysicalDiskMetricID(disk models.PhysicalDisk) string {
if diskinventory.IsUsableHardwareID(disk.Serial) || diskinventory.IsUsableHardwareID(disk.WWN) {
return PreferredPhysicalDiskMetricID(disk.Serial, disk.WWN, "")