Skip to content

armgit / Pulse

Public Imported from GitHub
0

Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.

feat: Merge linked host agent SMART temps into Physical Disks

rcourtman5ad1f5e84717
diff --git a/internal/monitoring/monitor.go b/internal/monitoring/monitor.go
index 5a5361016a..3dbdb6a14a 100644
--- a/internal/monitoring/monitor.go
+++ b/internal/monitoring/monitor.go
@@ -322,6 +322,111 @@ func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) [
return updated
}
+// mergeHostAgentSMARTIntoDisks merges SMART temperature data from linked host agents
+// into physical disks for Proxmox nodes. This allows disk temps collected by the
+// pulse-agent running on a PVE node to populate the Physical Disks view.
+func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.Node, hosts []models.Host) []models.PhysicalDisk {
+ if len(disks) == 0 || len(nodes) == 0 || len(hosts) == 0 {
+ return disks
+ }
+
+ // Build a map of host ID to host for quick lookup
+ hostByID := make(map[string]*models.Host, len(hosts))
+ for i := range hosts {
+ hostByID[hosts[i].ID] = &hosts[i]
+ }
+
+ // Build a map of node name to linked host's SMART data
+ smartByNodeName := make(map[string][]models.HostDiskSMART)
+ for _, node := range nodes {
+ if node.LinkedHostAgentID == "" {
+ continue
+ }
+ host, ok := hostByID[node.LinkedHostAgentID]
+ if !ok || len(host.Sensors.SMART) == 0 {
+ continue
+ }
+ smartByNodeName[node.Name] = host.Sensors.SMART
+ log.Debug().
+ Str("nodeName", node.Name).
+ Str("hostAgentID", node.LinkedHostAgentID).
+ Int("smartDiskCount", len(host.Sensors.SMART)).
+ Msg("mergeHostAgentSMARTIntoDisks: found linked host agent with SMART data")
+ }
+
+ if len(smartByNodeName) == 0 {
+ return disks
+ }
+
+ updated := make([]models.PhysicalDisk, len(disks))
+ copy(updated, disks)
+
+ for i := range updated {
+ // Skip if temperature is already populated
+ if updated[i].Temperature > 0 {
+ continue
+ }
+
+ smartData, ok := smartByNodeName[updated[i].Node]
+ if !ok || len(smartData) == 0 {
+ continue
+ }
+
+ // Try to match by WWN (most reliable)
+ if updated[i].WWN != "" {
+ for _, disk := range smartData {
+ if disk.WWN != "" && strings.EqualFold(disk.WWN, updated[i].WWN) {
+ if disk.Temperature > 0 && !disk.Standby {
+ updated[i].Temperature = disk.Temperature
+ log.Debug().
+ Str("device", updated[i].DevPath).
+ Str("wwn", updated[i].WWN).
+ Int("temp", disk.Temperature).
+ Msg("Matched host agent SMART temperature by WWN")
+ }
+ break
+ }
+ }
+ }
+
+ // Fall back to serial number match
+ if updated[i].Serial != "" && updated[i].Temperature == 0 {
+ for _, disk := range smartData {
+ if disk.Serial != "" && strings.EqualFold(disk.Serial, updated[i].Serial) {
+ if disk.Temperature > 0 && !disk.Standby {
+ updated[i].Temperature = disk.Temperature
+ log.Debug().
+ Str("device", updated[i].DevPath).
+ Str("serial", updated[i].Serial).
+ Int("temp", disk.Temperature).
+ Msg("Matched host agent SMART temperature by serial")
+ }
+ break
+ }
+ }
+ }
+
+ // Last resort: match by device path
+ if updated[i].Temperature == 0 {
+ normalizedDevPath := strings.TrimPrefix(updated[i].DevPath, "/dev/")
+ for _, disk := range smartData {
+ normalizedDiskDev := strings.TrimPrefix(disk.Device, "/dev/")
+ if normalizedDiskDev == normalizedDevPath {
+ if disk.Temperature > 0 && !disk.Standby {
+ updated[i].Temperature = disk.Temperature
+ log.Debug().
+ Str("device", updated[i].DevPath).
+ Int("temp", disk.Temperature).
+ Msg("Matched host agent SMART temperature by device path")
+ }
+ break
+ }
+ }
+ }
+ }
+
+ return updated
+}
func lookupClusterEndpointLabel(instance *config.PVEInstance, nodeName string) string {
if instance == nil {
return ""
@@ -5539,6 +5644,8 @@ func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, clie
}
if len(existing) > 0 {
updated := mergeNVMeTempsIntoDisks(existing, modelNodes)
+ // Also merge SMART data from linked host agents
+ updated = mergeHostAgentSMARTIntoDisks(updated, modelNodes, currentState.Hosts)
m.state.UpdatePhysicalDisks(instanceName, updated)
}
} else {
@@ -5690,6 +5797,8 @@ func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, clie
}
allDisks = mergeNVMeTempsIntoDisks(allDisks, modelNodesCopy)
+ // Also merge SMART data from linked host agents
+ allDisks = mergeHostAgentSMARTIntoDisks(allDisks, modelNodesCopy, currentState.Hosts)
// Update physical disks in state