Make existing extra-temperature and fan readings discoverable

pulse-triage[bot]6549ea6921e9
diff --git a/docs/TEMPERATURE_MONITORING.md b/docs/TEMPERATURE_MONITORING.md
index 7ea4b53d52..f6d1b598d9 100644
--- a/docs/TEMPERATURE_MONITORING.md
+++ b/docs/TEMPERATURE_MONITORING.md
@@ -35,6 +35,32 @@ Notes:
before changing its setup. A current server does not upgrade every agent.
- When a Proxmox host has recent usable agent temperature data, Pulse treats the agent as the source of truth and does not also try SSH temperature collection for that host.
+### Other Linux sensors and fan readings
+
+The overview's CPU temperature is not the full agent sensor list. On
+**Machines**, open the affected machine, expand **Details**, then **Machine →
+Show details**, and look for **Thermals**. For a merged Proxmox entry, the
+inner section is labelled **Host → Show host** instead. This card can show
+other temperatures and current fan RPM already present in the agent report;
+no SSH setup, driver change or additional permission is needed to open it.
+
+With usable `sensors -j` output, the Linux agent also retains positive
+non-CPU temperatures below 150 °C and positive fan RPM. Labels combine the
+chip type and sensor label: an applesmc `TB0T` reading can appear as
+**Applesmc Tb0t**, rather than **Battery**. Interpret chip-specific labels
+using that hardware's documentation; Pulse does not identify every sensor's
+physical location. A missing row is not a zero reading, and this is not an
+inventory of every `hwmon` file: the direct sysfs fallback is CPU/SoC-only.
+
+The card is a reading list, not a sensor picker. It does not offer friendly-name
+editing, fan min/max, a separate History series or an alert threshold for each
+extra sensor, or selection of a different sensor for the CPU row. CPU
+temperature History and CPU alerts remain CPU readings; a battery temperature
+must not be treated as CPU temperature. Seeing a battery reading here does not
+mean Pulse will alert on it. If a needed reading is absent, use the
+[existing-reading guidance](#check-existing-linux-readings-safely), not another
+agent install or wider host access.
+
### Check existing Linux readings safely
Use the monitored host's trusted local console, not the Pulse LXC or container.
diff --git a/frontend-modern/public/docs/TEMPERATURE_MONITORING.md b/frontend-modern/public/docs/TEMPERATURE_MONITORING.md
index 7ea4b53d52..f6d1b598d9 100644
--- a/frontend-modern/public/docs/TEMPERATURE_MONITORING.md
+++ b/frontend-modern/public/docs/TEMPERATURE_MONITORING.md
@@ -35,6 +35,32 @@ Notes:
before changing its setup. A current server does not upgrade every agent.
- When a Proxmox host has recent usable agent temperature data, Pulse treats the agent as the source of truth and does not also try SSH temperature collection for that host.
+### Other Linux sensors and fan readings
+
+The overview's CPU temperature is not the full agent sensor list. On
+**Machines**, open the affected machine, expand **Details**, then **Machine →
+Show details**, and look for **Thermals**. For a merged Proxmox entry, the
+inner section is labelled **Host → Show host** instead. This card can show
+other temperatures and current fan RPM already present in the agent report;
+no SSH setup, driver change or additional permission is needed to open it.
+
+With usable `sensors -j` output, the Linux agent also retains positive
+non-CPU temperatures below 150 °C and positive fan RPM. Labels combine the
+chip type and sensor label: an applesmc `TB0T` reading can appear as
+**Applesmc Tb0t**, rather than **Battery**. Interpret chip-specific labels
+using that hardware's documentation; Pulse does not identify every sensor's
+physical location. A missing row is not a zero reading, and this is not an
+inventory of every `hwmon` file: the direct sysfs fallback is CPU/SoC-only.
+
+The card is a reading list, not a sensor picker. It does not offer friendly-name
+editing, fan min/max, a separate History series or an alert threshold for each
+extra sensor, or selection of a different sensor for the CPU row. CPU
+temperature History and CPU alerts remain CPU readings; a battery temperature
+must not be treated as CPU temperature. Seeing a battery reading here does not
+mean Pulse will alert on it. If a needed reading is absent, use the
+[existing-reading guidance](#check-existing-linux-readings-safely), not another
+agent install or wider host access.
+
### Check existing Linux readings safely
Use the monitored host's trusted local console, not the Pulse LXC or container.
diff --git a/frontend-modern/src/features/docs/__tests__/temperatureFAQ.test.ts b/frontend-modern/src/features/docs/__tests__/temperatureFAQ.test.ts
index 5343c8c2f5..6c4a87f311 100644
--- a/frontend-modern/src/features/docs/__tests__/temperatureFAQ.test.ts
+++ b/frontend-modern/src/features/docs/__tests__/temperatureFAQ.test.ts
@@ -96,4 +96,34 @@ describe('shipped temperature FAQ', () => {
);
}
});
+
+ it('makes the existing extra-sensor view findable without promising battery alerts', () => {
+ const guide = document.createElement('article');
+ guide.innerHTML = renderDocMarkdown(
+ readFileSync(path.join(servedDocs, 'TEMPERATURE_MONITORING.md'), 'utf8'),
+ 'TEMPERATURE_MONITORING',
+ );
+ const heading = guide.querySelector('#other-linux-sensors-and-fan-readings');
+ expect(heading).not.toBeNull();
+ const section = document.createElement('section');
+ for (let next = heading!.nextElementSibling; next; next = next.nextElementSibling) {
+ if (/^H[1-6]$/.test(next.tagName)) break;
+ section.appendChild(next.cloneNode(true));
+ }
+ const text = prose(section);
+ expect(text).toContain('Machines');
+ expect(text).toContain('Machine → Show details');
+ expect(text).toContain('Host → Show host');
+ expect(text).toContain('Thermals');
+ expect(text).toContain('Applesmc Tb0t');
+ expect(text).toContain('direct sysfs fallback is CPU/SoC-only');
+ expect(text).toContain('not a sensor picker');
+ expect(text).toContain('fan min/max');
+ expect(text).toContain('does not mean Pulse will alert on it');
+ expect(section.querySelector('pre, table')).toBeNull();
+ expect(section.querySelector('a')?.getAttribute('href')).toBe(
+ '/docs/TEMPERATURE_MONITORING#check-existing-linux-readings-safely',
+ );
+ expect(section.querySelector('a')?.hasAttribute('data-doc-link')).toBe(true);
+ });
});