Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
fix(unifiedresources): merge PVE and agent rows for the same RAID array volume
Pulse Test674ca18968e7
diff --git a/internal/unifiedresources/registry.go b/internal/unifiedresources/registry.goindex a0752e604d..3a4ab82f41 100644--- a/internal/unifiedresources/registry.go+++ b/internal/unifiedresources/registry.go@@ -3050,9 +3050,10 @@ func (rr *ResourceRegistry) resolveLinkedPhysicalDisk(source DataSource, incomincontinue}- identityMatch :=- (incomingSerial != "" && strings.EqualFold(incomingSerial, existing.PhysicalDisk.Serial)) ||- (incomingWWN != "" && strings.EqualFold(incomingWWN, existing.PhysicalDisk.WWN))+ identityMatch := diskinventory.HardwareIdentityMatch(+ incomingSerial, incomingWWN,+ existing.PhysicalDisk.Serial, existing.PhysicalDisk.WWN,+ )existingDevice := strings.ToLower(normalizePhysicalDiskDeviceToken(existing.PhysicalDisk.DevPath))agentReportsSAS := (source == SourceProxmox && strings.EqualFold(existing.PhysicalDisk.DiskType, "sas")) ||(source == SourceAgent && strings.EqualFold(incoming.PhysicalDisk.DiskType, "sas"))diff --git a/internal/unifiedresources/registry_test.go b/internal/unifiedresources/registry_test.goindex 38a5c1ef55..fbf1b9c109 100644--- a/internal/unifiedresources/registry_test.go+++ b/internal/unifiedresources/registry_test.go@@ -6296,3 +6296,116 @@ func TestIssue1720AgentControllerMembersInheritOwningProxmoxScope(t *testing.T)t.Fatalf("controller members collapsed or disappeared: %v", targets)}}++// Follow-up regression on issue #1720: the PVE disks/list poll and the agent+// SMART report both observe the same RAID array volume, but PVE surfaces the+// NAA identifier as a bare-hex serial while smartctl reports it as a+// naa.-prefixed WWN with no serial at all. The two observations must join into+// one resource instead of rendering the volume twice with split histories.+// Sibling volumes on one controller share their truncated udev ID_WWN+// (0x + leading 16 hex), so the join must never match on truncated forms.+func TestIssue1720ArrayVolumeMergesBareSerialWithPrefixedWWN(t *testing.T) {+ now := time.Date(2026, 8, 27, 10, 0, 0, 0, time.UTC)+ registry := NewRegistry(nil)+ registry.IngestSnapshot(models.StateSnapshot{+ Nodes: []models.Node{{+ ID: "cluster-a-indus",+ Name: "indus",+ Instance: "cluster-a",+ ClusterName: "cluster-a",+ LinkedAgentID: "host-1",+ Status: "online",+ LastSeen: now,+ }},+ PhysicalDisks: []models.PhysicalDisk{+ {+ ID: "cluster-a-indus--dev-sda",+ Node: "indus",+ Instance: "cluster-a",+ DevPath: "/dev/sda",+ Model: "PERC_H730_Mini",+ Serial: "61866da053481f002f58a43b22f964a7",+ WWN: "0x61866da053481f00",+ Type: "sata",+ Health: "UNKNOWN",+ Size: 479_559_942_144,+ LastChecked: now,+ },+ {+ ID: "cluster-a-indus--dev-sdb",+ Node: "indus",+ Instance: "cluster-a",+ DevPath: "/dev/sdb",+ Model: "PERC_H730_Mini",+ Serial: "61866da053481f0030543ecb1d3b4cca",+ WWN: "0x61866da053481f00",+ Type: "sata",+ Health: "UNKNOWN",+ Size: 3_000_034_656_256,+ LastChecked: now,+ },+ },+ Hosts: []models.Host{{+ ID: "host-1",+ Hostname: "indus",+ LinkedNodeID: "cluster-a-indus",+ Status: "online",+ LastSeen: now,+ Sensors: models.HostSensorSummary{SMART: []models.HostDiskSMART{+ {+ Device: "sda",+ Model: "PERC H730 Mini",+ WWN: "naa.61866da053481f002f58a43b22f964a7",+ Type: "sata",+ Controller: "0000:02:00.0",+ Target: "0:2:0:0",+ SizeBytes: 479_559_942_144,+ Health: "UNKNOWN",+ Standby: true,+ },+ {+ Device: "sdb",+ Model: "PERC H730 Mini",+ WWN: "naa.61866da053481f0030543ecb1d3b4cca",+ Type: "sata",+ Controller: "0000:02:00.0",+ Target: "0:2:1:0",+ SizeBytes: 3_000_034_656_256,+ Health: "UNKNOWN",+ Standby: true,+ },+ }},+ }},+ })++ disks := registry.ListByType(ResourceTypePhysicalDisk)+ if len(disks) != 2 {+ devs := make([]string, 0, len(disks))+ for _, disk := range disks {+ if disk.PhysicalDisk != nil {+ devs = append(devs, disk.PhysicalDisk.DevPath)+ }+ }+ t.Fatalf("physical disk resources = %d (%v), want 2 merged volumes", len(disks), devs)+ }++ byPath := make(map[string]Resource, len(disks))+ for _, disk := range disks {+ if disk.PhysicalDisk == nil {+ t.Fatalf("disk %q has no physical-disk facet", disk.ID)+ }+ byPath[disk.PhysicalDisk.DevPath] = disk+ }+ for _, devPath := range []string{"/dev/sda", "/dev/sdb"} {+ disk, ok := byPath[devPath]+ if !ok {+ t.Fatalf("no merged resource kept canonical devPath %q: %v", devPath, byPath)+ }+ if !containsDataSource(disk.Sources, SourceAgent) || !containsDataSource(disk.Sources, SourceProxmox) {+ t.Fatalf("disk %q sources = %v, want merged proxmox+agent", devPath, disk.Sources)+ }+ }+ if byPath["/dev/sda"].PhysicalDisk.SizeBytes == byPath["/dev/sdb"].PhysicalDisk.SizeBytes {+ t.Fatalf("sibling volumes collapsed into one identity: %+v", byPath)+ }+}diff --git a/pkg/diskinventory/identity.go b/pkg/diskinventory/identity.goindex 62d47ac42b..36ef7cba64 100644--- a/pkg/diskinventory/identity.go+++ b/pkg/diskinventory/identity.go@@ -66,6 +66,54 @@ func IsUsableHardwareID(value string) bool {return !allZero && !allF}+// normalizeHardwareID canonicalizes a serial or WWN for cross-source+// comparison. Reporters disagree on framing, not identity: smartctl emits+// naa./eui.-prefixed WWNs, udev emits wwn-0x tokens, and PVE surfaces bare+// hex. Values are only ever prefix-stripped and case-folded, never truncated:+// sibling volumes on one RAID controller share their leading WWN bytes, so a+// truncated form must stay unequal to the full identifier.+func normalizeHardwareID(value string) string {+ value = strings.ToLower(strings.TrimSpace(value))+ if !IsUsableHardwareID(value) {+ return ""+ }+ for {+ trimmed := value+ for _, prefix := range []string{"naa.", "eui.", "wwn-", "0x"} {+ trimmed = strings.TrimPrefix(trimmed, prefix)+ }+ if trimmed == value {+ break+ }+ value = trimmed+ }+ if !IsUsableHardwareID(value) {+ return ""+ }+ return value+}++// HardwareIdentityMatch reports whether two disk observations carry the same+// stable hardware identity. Serial and WWN are folded together because+// sources disagree on which field holds the durable identifier: PVE reports a+// RAID array volume's NAA identifier as its serial while smartctl reports the+// same value as a naa.-prefixed WWN with no serial at all.+func HardwareIdentityMatch(leftSerial, leftWWN, rightSerial, rightWWN string) bool {+ left := [2]string{normalizeHardwareID(leftSerial), normalizeHardwareID(leftWWN)}+ right := [2]string{normalizeHardwareID(rightSerial), normalizeHardwareID(rightWWN)}+ for _, l := range left {+ if l == "" {+ continue+ }+ for _, r := range right {+ if r != "" && l == r {+ return true+ }+ }+ }+ return false+}+// IsControllerMemberTarget reports whether target addresses one member behind// a shared controller block path. Controller grammars vary after the numeric// member prefix (for example megaraid,7, areca,1/1, and sssraid,0,1).diff --git a/pkg/diskinventory/identity_test.go b/pkg/diskinventory/identity_test.goindex b130141c7e..f3477f7384 100644--- a/pkg/diskinventory/identity_test.go+++ b/pkg/diskinventory/identity_test.go@@ -54,3 +54,74 @@ func TestPreferredIDRejectsPlaceholderHardwareIdentity(t *testing.T) {t.Fatal("real disk serial/WWN was rejected")}}++func TestHardwareIdentityMatch(t *testing.T) {+ cases := []struct {+ name string+ aSerial, aWWN string+ bSerial, bWWN string+ want bool+ }{+ {+ name: "pve bare-hex serial matches smartctl naa wwn",+ aSerial: "61866da053481f002f58a43b22f964a7",+ aWWN: "0x61866da053481f00",+ bWWN: "naa.61866da053481f002f58a43b22f964a7",+ want: true,+ },+ {+ name: "same serial different case",+ aSerial: "zr5dlayj",+ bSerial: "ZR5DLAYJ",+ want: true,+ },+ {+ name: "udev wwn-0x token matches naa wwn",+ aWWN: "wwn-0x5000c500abcdef01",+ bWWN: "naa.5000c500abcdef01",+ want: true,+ },+ {+ name: "eui prefix matches bare nvme id",+ aWWN: "eui.0025385b91501234",+ bWWN: "0025385b91501234",+ want: true,+ },+ {+ name: "truncated udev wwn never matches full sibling identifier",+ aWWN: "0x61866da053481f00",+ bSerial: "61866da053481f0030543ecb1d3b4cca",+ bWWN: "naa.61866da053481f0030543ecb1d3b4cca",+ want: false,+ },+ {+ name: "placeholder serials do not match each other",+ aSerial: "UNKNOWN",+ bSerial: "UNKNOWN",+ want: false,+ },+ {+ name: "distinct disks stay distinct",+ aSerial: "9410A0FWFVL9",+ bSerial: "35C0A39YFVL9",+ want: false,+ },+ {+ name: "empty observations never match",+ want: false,+ },+ }+ for _, tc := range cases {+ t.Run(tc.name, func(t *testing.T) {+ got := HardwareIdentityMatch(tc.aSerial, tc.aWWN, tc.bSerial, tc.bWWN)+ if got != tc.want {+ t.Fatalf("HardwareIdentityMatch(%q,%q,%q,%q) = %v, want %v",+ tc.aSerial, tc.aWWN, tc.bSerial, tc.bWWN, got, tc.want)+ }+ mirrored := HardwareIdentityMatch(tc.bSerial, tc.bWWN, tc.aSerial, tc.aWWN)+ if mirrored != tc.want {+ t.Fatalf("match is not symmetric: mirrored = %v, want %v", mirrored, tc.want)+ }+ })+ }+}