Add critical safety guards to temperature proxy installation
rcourtman6a5b8d698b39
diff --git a/cmd/pulse-sensor-proxy/ssh.go b/cmd/pulse-sensor-proxy/ssh.goindex 2730f7a01e..11c3c58cb2 100644--- a/cmd/pulse-sensor-proxy/ssh.go+++ b/cmd/pulse-sensor-proxy/ssh.go@@ -579,23 +579,51 @@ func discoverClusterNodes() ([]string, error) {stdoutStr := out.String()combinedOutput := stderrStr + stdoutStr- // Check if this is a standalone node or LXC container- // - "does not exist" or "not part of a cluster": standalone node- // - "ipcc_send_rec": running in LXC container without corosync access- // - "Unknown error -1": LXC container corosync communication failure- // - "Unable to load access control list": Permission/access issues in containers- // Note: Some Proxmox versions write these messages to stdout, others to stderr- if strings.Contains(combinedOutput, "does not exist") ||- strings.Contains(combinedOutput, "not part of a cluster") ||- strings.Contains(combinedOutput, "ipcc_send_rec") ||- strings.Contains(combinedOutput, "Unknown error -1") ||- strings.Contains(combinedOutput, "Unable to load access control list") {+ // Broadly detect standalone/container scenarios by checking for known patterns+ // This list comes from real user reports and should handle localization/version differences+ //+ // Common patterns that indicate standalone/container operation:+ // - Configuration missing: "does not exist", "not found", "no such file"+ // - Cluster state: "not part of a cluster", "no cluster", "standalone"+ // - IPC failures: "ipcc_send_rec", "IPC", "communication failed"+ // - Permission/access: "Unknown error -1", "Unable to load", "access denied", "permission denied"+ //+ // Strategy: Be permissive - if pvecm fails with any of these common patterns,+ // assume standalone and fall back to localhost. This is safer than false negatives.+ standaloneIndicators := []string{+ // Configuration issues+ "does not exist", "not found", "no such file",+ // Cluster state+ "not part of a cluster", "no cluster", "standalone",+ // IPC/communication failures (common in LXC)+ "ipcc_send_rec", "IPC", "communication failed", "connection refused",+ // Permission/access issues+ "Unknown error -1", "Unable to load", "access denied", "permission denied",+ "access control list",+ }++ isStandalone := false+ for _, indicator := range standaloneIndicators {+ if strings.Contains(strings.ToLower(combinedOutput), strings.ToLower(indicator)) {+ isStandalone = true+ break+ }+ }++ if isStandalone {// Log at INFO level since this is expected for standalone/container scenarios- log.Info().Msg("Standalone Proxmox node or LXC container detected - using localhost for temperature collection")+ log.Info().+ Str("exit_code", fmt.Sprintf("%v", err)).+ Msg("Standalone Proxmox node or LXC container detected - using localhost for temperature collection")return discoverLocalHostAddresses()}- // For other unexpected errors, fail with details- log.Warn().Str("stderr", stderrStr).Str("stdout", stdoutStr).Msg("pvecm status failed with unexpected error")++ // For truly unexpected errors (rare), fail with full context for debugging+ log.Warn().+ Err(err).+ Str("stderr", stderrStr).+ Str("stdout", stdoutStr).+ Msg("pvecm status failed with unexpected error - please report this if temperature monitoring doesn't work")return nil, fmt.Errorf("failed to get cluster status: %w (stderr: %s, stdout: %s)", err, stderrStr, stdoutStr)}diff --git a/cmd/pulse-sensor-proxy/ssh_test.go b/cmd/pulse-sensor-proxy/ssh_test.goindex 3288e9ee65..3ec45ea364 100644--- a/cmd/pulse-sensor-proxy/ssh_test.go+++ b/cmd/pulse-sensor-proxy/ssh_test.go@@ -250,18 +250,41 @@ func TestStandaloneNodeErrorPatterns(t *testing.T) {stderr: "",issueNo: "#571",},+ {+ name: "no cluster keyword",+ stderr: "Error: no cluster configuration\n",+ stdout: "",+ issueNo: "variation",+ },+ {+ name: "IPC failure variant",+ stderr: "IPC communication error\n",+ stdout: "",+ issueNo: "variation",+ },+ }++ // Use the same detection logic as the actual code+ standaloneIndicators := []string{+ "does not exist", "not found", "no such file",+ "not part of a cluster", "no cluster", "standalone",+ "ipcc_send_rec", "IPC", "communication failed", "connection refused",+ "Unknown error -1", "Unable to load", "access denied", "permission denied",+ "access control list",}for _, tc := range standalonePatterns {t.Run(tc.name, func(t *testing.T) {combinedOutput := tc.stderr + tc.stdout- // Check each detection pattern we added- isStandalone := strings.Contains(combinedOutput, "does not exist") ||- strings.Contains(combinedOutput, "not part of a cluster") ||- strings.Contains(combinedOutput, "ipcc_send_rec") ||- strings.Contains(combinedOutput, "Unknown error -1") ||- strings.Contains(combinedOutput, "Unable to load access control list")+ // Check using the permissive detection strategy+ isStandalone := false+ for _, indicator := range standaloneIndicators {+ if strings.Contains(strings.ToLower(combinedOutput), strings.ToLower(indicator)) {+ isStandalone = true+ break+ }+ }if !isStandalone {t.Errorf("Failed to detect standalone/LXC pattern from %s:\n stderr: %q\n stdout: %q",diff --git a/install.sh b/install.shindex 91f9138a85..9576eff121 100755--- a/install.sh+++ b/install.sh@@ -1585,17 +1585,30 @@ fi'; thenif bash "$proxy_script" "${proxy_install_args[@]}" 2>&1 | tee /tmp/proxy-install-${CTID}.log; thenprint_info "Temperature proxy installation script completed"- # Verify proxy is actually working- echo- print_info "Verifying temperature proxy health..."- local proxy_health_ok=true-- # Check 1: Service is running- if ! systemctl is-active --quiet pulse-sensor-proxy 2>/dev/null; then- print_error "✗ Service not running"- proxy_health_ok=false+ # Check if health checks should be skipped+ if [[ "${PULSE_SKIP_HEALTH_CHECKS:-}" == "1" ]]; then+ print_warn "⚠ Health checks skipped (PULSE_SKIP_HEALTH_CHECKS=1)"+ print_warn " Temperature monitoring may not work correctly"+ print_warn " Verify manually: systemctl status pulse-sensor-proxy"+ echoelse- print_info "✓ Service running"+ # Verify proxy is actually working (with graceful fallbacks)+ echo+ print_info "Verifying temperature proxy health..."+ local proxy_health_ok=true+ local health_warnings=()++ # Check 1: Service is running (with timeout)+ if command -v systemctl >/dev/null 2>&1; then+ if timeout 5 systemctl is-active --quiet pulse-sensor-proxy 2>/dev/null; then+ print_info "✓ Service running"+ else+ print_error "✗ Service not running"+ proxy_health_ok=false+ fi+ else+ print_warn "⚠ systemctl not available - skipping service check"+ health_warnings+=("systemctl not available")fi# Check 2: Socket exists@@ -1606,27 +1619,60 @@ fi'; thenprint_info "✓ Socket exists"fi- # Check 3: Socket is accessible from container- if ! pct exec $CTID -- test -S /mnt/pulse-proxy/pulse-sensor-proxy.sock 2>/dev/null; then- print_error "✗ Socket not visible inside container at /mnt/pulse-proxy/pulse-sensor-proxy.sock"- print_error " Bind mount may not be configured correctly"- proxy_health_ok=false+ # Check 3: Socket is accessible from container (with timeout and fallback)+ if command -v pct >/dev/null 2>&1; then+ # Use timeout to prevent hanging if container is stopped/frozen+ if timeout 10 pct exec $CTID -- test -S /mnt/pulse-proxy/pulse-sensor-proxy.sock 2>/dev/null; then+ print_info "✓ Socket accessible from container"+ else+ # Don't fail immediately - container might be stopped or not fully booted+ print_warn "⚠ Could not verify socket accessibility from container"+ print_warn " This may be normal if container is stopped or not fully started"+ print_warn " Socket will be checked when container starts"+ health_warnings+=("container socket check failed (may be transient)")+ fielse- print_info "✓ Socket accessible from container"+ print_warn "⚠ pct command not available - skipping container socket check"+ health_warnings+=("pct not available")fi+ # Only fail if critical checks failed (service or socket on host)if [[ "$proxy_health_ok" != "true" ]]; thenechoprint_error "Temperature proxy health check failed"print_error "See diagnostics above and logs: /tmp/proxy-install-${CTID}.log"print_error ""- print_error "Check: systemctl status pulse-sensor-proxy"- print_error "Check: journalctl -u pulse-sensor-proxy -n 50"++ # Provide actionable diagnostics if tools are available+ if command -v systemctl >/dev/null 2>&1; then+ print_error "Check: systemctl status pulse-sensor-proxy"+ fi+ if command -v journalctl >/dev/null 2>&1; then+ print_error "Check: journalctl -u pulse-sensor-proxy -n 50"+ else+ print_error "Check: cat /var/log/syslog | grep pulse-sensor-proxy"+ fi+ print_error ""+ print_error "To bypass health checks (not recommended): Set PULSE_SKIP_HEALTH_CHECKS=1"echoexit 1fi- print_success "Temperature proxy is healthy and ready"+ # Show warnings summary if any+ if [[ ${#health_warnings[@]} -gt 0 ]]; then+ echo+ print_warn "Health check completed with warnings:"+ for warning in "${health_warnings[@]}"; do+ print_warn " - $warning"+ done+ print_info "Proxy installed but some checks could not be verified"+ print_info "Temperature monitoring may still work correctly"+ echo+ fi++ print_success "Temperature proxy is healthy and ready"+ fi # End of health checks+# Clean up temporary binary if it was copied[[ -f "$local_proxy_binary" ]] && rm -f "$local_proxy_binary"else