Forward-port Proxmox SMART disk merge semantics

rcourtman77d18aed4dd0
diff --git a/docs/release-control/v6/internal/subsystems/monitoring.md b/docs/release-control/v6/internal/subsystems/monitoring.md
index fc280e4cc3..01450aad8b 100644
--- a/docs/release-control/v6/internal/subsystems/monitoring.md
+++ b/docs/release-control/v6/internal/subsystems/monitoring.md
@@ -282,6 +282,15 @@ Physical-disk refresh/merge logic now derives physical disks, nodes, and linked
host-agent context from canonical `ReadState` before applying NVMe temperature
and SMART merges, so skipped or background disk refresh no longer treats the
snapshot as internal truth for that path.
+That same monitoring-owned disk merge path must also treat host-agent SMART
+attributes as canonical fill data for the Proxmox disk view. When a linked
+host agent reports SMART health or NVMe `percentage_used` for a physical disk
+that Proxmox itself exposes without trustworthy health or wearout, the merge
+path in `internal/monitoring/monitor.go` must promote that data into the
+canonical physical-disk model and the Proxmox polling runtime in
+`internal/monitoring/monitor_pve.go` must evaluate disk alerts only after that
+merged disk view exists, so controller-backed disks do not lose health and
+endurance coverage between collection and alerting.
Backup polling and recovery guest identity assembly now derive workload node,
name, and type context from canonical `ReadState` instead of from
diff --git a/internal/monitoring/canonical_guardrails_test.go b/internal/monitoring/canonical_guardrails_test.go
index fc9be53029..fda09603bd 100644
--- a/internal/monitoring/canonical_guardrails_test.go
+++ b/internal/monitoring/canonical_guardrails_test.go
@@ -440,6 +440,43 @@ func TestUnifiedPhysicalDiskMetricsUseCanonicalDiskHistoryPath(t *testing.T) {
}
}
+func TestProxmoxDiskAlertsRunOnMergedDiskState(t *testing.T) {
+ cases := []struct {
+ file string
+ snippets []string
+ }{
+ {
+ file: "monitor.go",
+ snippets: []string{
+ "func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.Node, hosts []models.Host) []models.PhysicalDisk {",
+ "deriveWearoutFromSMARTAttributes(matched.Attributes)",
+ `strings.EqualFold(updated[i].Health, "unknown")`,
+ },
+ },
+ {
+ file: "monitor_pve.go",
+ snippets: []string{
+ "allDisks = mergeHostAgentSMARTIntoDisks(allDisks, nodesFromState, hosts)",
+ "m.alertManager.CheckDiskHealth(inst, disk.Node, proxmoxDiskFromPhysicalDisk(disk))",
+ "func proxmoxDiskFromPhysicalDisk(disk models.PhysicalDisk) proxmox.Disk {",
+ },
+ },
+ }
+
+ for _, tc := range cases {
+ data, err := os.ReadFile(tc.file)
+ if err != nil {
+ t.Fatalf("failed to read %s: %v", tc.file, err)
+ }
+ source := string(data)
+ for _, snippet := range tc.snippets {
+ if !strings.Contains(source, snippet) {
+ t.Fatalf("%s must contain %q", tc.file, snippet)
+ }
+ }
+ }
+}
+
func TestUnifiedPhysicalDiskMetricsAllowNativeHistoryProviders(t *testing.T) {
monitorData, err := os.ReadFile("monitor.go")
if err != nil {
diff --git a/internal/monitoring/monitor.go b/internal/monitoring/monitor.go
index 4eb1323c72..af363dbfe4 100644
--- a/internal/monitoring/monitor.go
+++ b/internal/monitoring/monitor.go
@@ -526,13 +526,37 @@ func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.No
// Always merge SMART attributes from host agent
if matched.Attributes != nil {
- updated[i].SmartAttributes = matched.Attributes
+ updated[i].SmartAttributes = smartAttributesCopy(matched.Attributes)
+ if updated[i].Wearout < 0 {
+ if derivedWearout := deriveWearoutFromSMARTAttributes(matched.Attributes); derivedWearout >= 0 {
+ updated[i].Wearout = derivedWearout
+ }
+ }
+ }
+
+ if (strings.TrimSpace(updated[i].Health) == "" || strings.EqualFold(updated[i].Health, "unknown")) && strings.TrimSpace(matched.Health) != "" {
+ updated[i].Health = matched.Health
}
}
return updated
}
+func deriveWearoutFromSMARTAttributes(attrs *models.SMARTAttributes) int {
+ if attrs == nil || attrs.PercentageUsed == nil {
+ return -1
+ }
+
+ used := *attrs.PercentageUsed
+ if used < 0 {
+ used = 0
+ }
+ if used > 100 {
+ used = 100
+ }
+ return 100 - used
+}
+
func physicalDiskFromReadStateView(view *unifiedresources.PhysicalDiskView) models.PhysicalDisk {
if view == nil {
return models.PhysicalDisk{}
diff --git a/internal/monitoring/monitor_integration_test.go b/internal/monitoring/monitor_integration_test.go
index 6b60cea599..88446cb92e 100644
--- a/internal/monitoring/monitor_integration_test.go
+++ b/internal/monitoring/monitor_integration_test.go
@@ -148,6 +148,65 @@ func TestMergeHostAgentSMARTIntoDisks_MergesSMARTAttributes(t *testing.T) {
}
}
+func TestMergeHostAgentSMARTIntoDisks_DerivesWearoutFromSMARTAttributes(t *testing.T) {
+ disks := []models.PhysicalDisk{
+ {ID: "d1", Node: "pve1", Serial: "SER1", Wearout: -1},
+ }
+ nodes := []models.Node{
+ {Name: "pve1", LinkedAgentID: "host-1"},
+ }
+ used := 6
+ hosts := []models.Host{
+ {
+ ID: "host-1",
+ Sensors: models.HostSensorSummary{
+ SMART: []models.HostDiskSMART{
+ {
+ Device: "/dev/sda [megaraid,7]",
+ Serial: "SER1",
+ Health: "PASSED",
+ Attributes: &models.SMARTAttributes{
+ PercentageUsed: &used,
+ },
+ },
+ },
+ },
+ },
+ }
+
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ if result[0].Wearout != 94 {
+ t.Fatalf("expected wearout derived from PercentageUsed, got %d", result[0].Wearout)
+ }
+ if result[0].SmartAttributes == nil || result[0].SmartAttributes.PercentageUsed == nil || *result[0].SmartAttributes.PercentageUsed != 6 {
+ t.Fatalf("expected merged PercentageUsed, got %+v", result[0].SmartAttributes)
+ }
+}
+
+func TestMergeHostAgentSMARTIntoDisks_FillsMissingHealthFromHostSMART(t *testing.T) {
+ disks := []models.PhysicalDisk{
+ {ID: "d1", Node: "pve1", Serial: "SER1", Health: "UNKNOWN"},
+ }
+ nodes := []models.Node{
+ {Name: "pve1", LinkedAgentID: "host-1"},
+ }
+ hosts := []models.Host{
+ {
+ ID: "host-1",
+ Sensors: models.HostSensorSummary{
+ SMART: []models.HostDiskSMART{
+ {Device: "/dev/sda", Serial: "SER1", Health: "FAILED"},
+ },
+ },
+ },
+ }
+
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ if result[0].Health != "FAILED" {
+ t.Fatalf("expected host SMART health to fill unknown disk health, got %q", result[0].Health)
+ }
+}
+
func TestMergeHostAgentSMARTIntoDisks_NoAgentLink(t *testing.T) {
disks := []models.PhysicalDisk{
{ID: "d1", Node: "pve1", Serial: "SER1", Temperature: 0},
diff --git a/internal/monitoring/monitor_pve.go b/internal/monitoring/monitor_pve.go
index 9dd33f12f3..dc6061c6a9 100644
--- a/internal/monitoring/monitor_pve.go
+++ b/internal/monitoring/monitor_pve.go
@@ -807,9 +807,9 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
// Mark this node as successfully polled
polledNodes[node.Node] = true
- // Check each disk for health issues and add to state
+ // Record each disk; alert evaluation happens after host-agent SMART merges
+ // so the canonical disk view includes post-merge health/wearout data.
for _, disk := range disks {
- // Create PhysicalDisk model
diskID := fmt.Sprintf("%s-%s-%s", inst, node.Node, strings.ReplaceAll(disk.DevPath, "/", "-"))
physicalDisk := models.PhysicalDisk{
ID: diskID,
@@ -829,53 +829,6 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
}
allDisks = append(allDisks, physicalDisk)
-
- log.Debug().
- Str("node", node.Node).
- Str("disk", disk.DevPath).
- Str("model", disk.Model).
- Str("health", disk.Health).
- Int("wearout", disk.Wearout).
- Msg("Checking disk health")
-
- // If the linked host agent has --disk-exclude patterns that match
- // this disk, send a synthetic healthy status to clear any existing
- // alerts and skip normal health/wearout checks.
- if excludePatterns, ok := diskExcludeByNode[node.Node]; ok {
- if fsfilters.MatchesDeviceExclude(disk.DevPath, excludePatterns) {
- healthyDisk := disk
- healthyDisk.Health = "PASSED"
- healthyDisk.Wearout = 100
- m.alertManager.CheckDiskHealth(inst, node.Node, healthyDisk)
- continue
- }
- }
-
- normalizedHealth := strings.ToUpper(strings.TrimSpace(disk.Health))
- if normalizedHealth != "" && normalizedHealth != "UNKNOWN" && normalizedHealth != "PASSED" && normalizedHealth != "OK" {
- // Disk has failed or is failing - alert manager will handle this
- log.Warn().
- Str("node", node.Node).
- Str("disk", disk.DevPath).
- Str("model", disk.Model).
- Str("health", disk.Health).
- Int("wearout", disk.Wearout).
- Msg("Disk health issue detected")
-
- // Pass disk info to alert manager
- m.alertManager.CheckDiskHealth(inst, node.Node, disk)
- } else if disk.Wearout > 0 && disk.Wearout < 10 {
- // Low wearout warning (less than 10% life remaining)
- log.Warn().
- Str("node", node.Node).
- Str("disk", disk.DevPath).
- Str("model", disk.Model).
- Int("wearout", disk.Wearout).
- Msg("SSD wearout critical - less than 10% life remaining")
-
- // Pass to alert manager for wearout alert
- m.alertManager.CheckDiskHealth(inst, node.Node, disk)
- }
}
}
@@ -894,6 +847,29 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
allDisks = mergeNVMeTempsIntoDisks(allDisks, nodesFromState)
allDisks = mergeHostAgentSMARTIntoDisks(allDisks, nodesFromState, hosts)
+ for _, disk := range allDisks {
+ if !polledNodes[disk.Node] {
+ continue
+ }
+
+ log.Debug().
+ Str("node", disk.Node).
+ Str("disk", disk.DevPath).
+ Str("model", disk.Model).
+ Str("health", disk.Health).
+ Int("wearout", disk.Wearout).
+ Msg("Checking disk health")
+
+ if excludePatterns, ok := diskExcludeByNode[disk.Node]; ok && fsfilters.MatchesDeviceExclude(disk.DevPath, excludePatterns) {
+ healthyDisk := proxmoxDiskFromPhysicalDisk(disk)
+ healthyDisk.Health = "PASSED"
+ healthyDisk.Wearout = 100
+ m.alertManager.CheckDiskHealth(inst, disk.Node, healthyDisk)
+ continue
+ }
+
+ m.alertManager.CheckDiskHealth(inst, disk.Node, proxmoxDiskFromPhysicalDisk(disk))
+ }
// Write SMART metrics to persistent store
if m.metricsStore != nil {
@@ -913,6 +889,21 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
}(instanceName, client, nodes, nodeEffectiveStatus, modelNodes)
}
+func proxmoxDiskFromPhysicalDisk(disk models.PhysicalDisk) proxmox.Disk {
+ return proxmox.Disk{
+ DevPath: disk.DevPath,
+ Model: disk.Model,
+ Serial: disk.Serial,
+ Type: disk.Type,
+ Health: disk.Health,
+ Wearout: disk.Wearout,
+ Size: disk.Size,
+ RPM: disk.RPM,
+ Used: disk.Used,
+ WWN: disk.WWN,
+ }
+}
+
// pollPVEInstance polls a single PVE instance
func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, client PVEClientInterface) {
defer recoverFromPanic(fmt.Sprintf("pollPVEInstance-%s", instanceName))