Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Forward-port Proxmox SMART disk merge semantics
rcourtman77d18aed4dd0
diff --git a/docs/release-control/v6/internal/subsystems/monitoring.md b/docs/release-control/v6/internal/subsystems/monitoring.mdindex fc280e4cc3..01450aad8b 100644--- a/docs/release-control/v6/internal/subsystems/monitoring.md+++ b/docs/release-control/v6/internal/subsystems/monitoring.md@@ -282,6 +282,15 @@ Physical-disk refresh/merge logic now derives physical disks, nodes, and linkedhost-agent context from canonical `ReadState` before applying NVMe temperatureand SMART merges, so skipped or background disk refresh no longer treats thesnapshot as internal truth for that path.+That same monitoring-owned disk merge path must also treat host-agent SMART+attributes as canonical fill data for the Proxmox disk view. When a linked+host agent reports SMART health or NVMe `percentage_used` for a physical disk+that Proxmox itself exposes without trustworthy health or wearout, the merge+path in `internal/monitoring/monitor.go` must promote that data into the+canonical physical-disk model and the Proxmox polling runtime in+`internal/monitoring/monitor_pve.go` must evaluate disk alerts only after that+merged disk view exists, so controller-backed disks do not lose health and+endurance coverage between collection and alerting.Backup polling and recovery guest identity assembly now derive workload node,name, and type context from canonical `ReadState` instead of fromdiff --git a/internal/monitoring/canonical_guardrails_test.go b/internal/monitoring/canonical_guardrails_test.goindex fc9be53029..fda09603bd 100644--- a/internal/monitoring/canonical_guardrails_test.go+++ b/internal/monitoring/canonical_guardrails_test.go@@ -440,6 +440,43 @@ func TestUnifiedPhysicalDiskMetricsUseCanonicalDiskHistoryPath(t *testing.T) {}}+func TestProxmoxDiskAlertsRunOnMergedDiskState(t *testing.T) {+ cases := []struct {+ file string+ snippets []string+ }{+ {+ file: "monitor.go",+ snippets: []string{+ "func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.Node, hosts []models.Host) []models.PhysicalDisk {",+ "deriveWearoutFromSMARTAttributes(matched.Attributes)",+ `strings.EqualFold(updated[i].Health, "unknown")`,+ },+ },+ {+ file: "monitor_pve.go",+ snippets: []string{+ "allDisks = mergeHostAgentSMARTIntoDisks(allDisks, nodesFromState, hosts)",+ "m.alertManager.CheckDiskHealth(inst, disk.Node, proxmoxDiskFromPhysicalDisk(disk))",+ "func proxmoxDiskFromPhysicalDisk(disk models.PhysicalDisk) proxmox.Disk {",+ },+ },+ }++ for _, tc := range cases {+ data, err := os.ReadFile(tc.file)+ if err != nil {+ t.Fatalf("failed to read %s: %v", tc.file, err)+ }+ source := string(data)+ for _, snippet := range tc.snippets {+ if !strings.Contains(source, snippet) {+ t.Fatalf("%s must contain %q", tc.file, snippet)+ }+ }+ }+}+func TestUnifiedPhysicalDiskMetricsAllowNativeHistoryProviders(t *testing.T) {monitorData, err := os.ReadFile("monitor.go")if err != nil {diff --git a/internal/monitoring/monitor.go b/internal/monitoring/monitor.goindex 4eb1323c72..af363dbfe4 100644--- a/internal/monitoring/monitor.go+++ b/internal/monitoring/monitor.go@@ -526,13 +526,37 @@ func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.No// Always merge SMART attributes from host agentif matched.Attributes != nil {- updated[i].SmartAttributes = matched.Attributes+ updated[i].SmartAttributes = smartAttributesCopy(matched.Attributes)+ if updated[i].Wearout < 0 {+ if derivedWearout := deriveWearoutFromSMARTAttributes(matched.Attributes); derivedWearout >= 0 {+ updated[i].Wearout = derivedWearout+ }+ }+ }++ if (strings.TrimSpace(updated[i].Health) == "" || strings.EqualFold(updated[i].Health, "unknown")) && strings.TrimSpace(matched.Health) != "" {+ updated[i].Health = matched.Health}}return updated}+func deriveWearoutFromSMARTAttributes(attrs *models.SMARTAttributes) int {+ if attrs == nil || attrs.PercentageUsed == nil {+ return -1+ }++ used := *attrs.PercentageUsed+ if used < 0 {+ used = 0+ }+ if used > 100 {+ used = 100+ }+ return 100 - used+}+func physicalDiskFromReadStateView(view *unifiedresources.PhysicalDiskView) models.PhysicalDisk {if view == nil {return models.PhysicalDisk{}diff --git a/internal/monitoring/monitor_integration_test.go b/internal/monitoring/monitor_integration_test.goindex 6b60cea599..88446cb92e 100644--- a/internal/monitoring/monitor_integration_test.go+++ b/internal/monitoring/monitor_integration_test.go@@ -148,6 +148,65 @@ func TestMergeHostAgentSMARTIntoDisks_MergesSMARTAttributes(t *testing.T) {}}+func TestMergeHostAgentSMARTIntoDisks_DerivesWearoutFromSMARTAttributes(t *testing.T) {+ disks := []models.PhysicalDisk{+ {ID: "d1", Node: "pve1", Serial: "SER1", Wearout: -1},+ }+ nodes := []models.Node{+ {Name: "pve1", LinkedAgentID: "host-1"},+ }+ used := 6+ hosts := []models.Host{+ {+ ID: "host-1",+ Sensors: models.HostSensorSummary{+ SMART: []models.HostDiskSMART{+ {+ Device: "/dev/sda [megaraid,7]",+ Serial: "SER1",+ Health: "PASSED",+ Attributes: &models.SMARTAttributes{+ PercentageUsed: &used,+ },+ },+ },+ },+ },+ }++ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)+ if result[0].Wearout != 94 {+ t.Fatalf("expected wearout derived from PercentageUsed, got %d", result[0].Wearout)+ }+ if result[0].SmartAttributes == nil || result[0].SmartAttributes.PercentageUsed == nil || *result[0].SmartAttributes.PercentageUsed != 6 {+ t.Fatalf("expected merged PercentageUsed, got %+v", result[0].SmartAttributes)+ }+}++func TestMergeHostAgentSMARTIntoDisks_FillsMissingHealthFromHostSMART(t *testing.T) {+ disks := []models.PhysicalDisk{+ {ID: "d1", Node: "pve1", Serial: "SER1", Health: "UNKNOWN"},+ }+ nodes := []models.Node{+ {Name: "pve1", LinkedAgentID: "host-1"},+ }+ hosts := []models.Host{+ {+ ID: "host-1",+ Sensors: models.HostSensorSummary{+ SMART: []models.HostDiskSMART{+ {Device: "/dev/sda", Serial: "SER1", Health: "FAILED"},+ },+ },+ },+ }++ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)+ if result[0].Health != "FAILED" {+ t.Fatalf("expected host SMART health to fill unknown disk health, got %q", result[0].Health)+ }+}+func TestMergeHostAgentSMARTIntoDisks_NoAgentLink(t *testing.T) {disks := []models.PhysicalDisk{{ID: "d1", Node: "pve1", Serial: "SER1", Temperature: 0},diff --git a/internal/monitoring/monitor_pve.go b/internal/monitoring/monitor_pve.goindex 9dd33f12f3..dc6061c6a9 100644--- a/internal/monitoring/monitor_pve.go+++ b/internal/monitoring/monitor_pve.go@@ -807,9 +807,9 @@ func (m *Monitor) maybePollPhysicalDisksAsync(// Mark this node as successfully polledpolledNodes[node.Node] = true- // Check each disk for health issues and add to state+ // Record each disk; alert evaluation happens after host-agent SMART merges+ // so the canonical disk view includes post-merge health/wearout data.for _, disk := range disks {- // Create PhysicalDisk modeldiskID := fmt.Sprintf("%s-%s-%s", inst, node.Node, strings.ReplaceAll(disk.DevPath, "/", "-"))physicalDisk := models.PhysicalDisk{ID: diskID,@@ -829,53 +829,6 @@ func (m *Monitor) maybePollPhysicalDisksAsync(}allDisks = append(allDisks, physicalDisk)-- log.Debug().- Str("node", node.Node).- Str("disk", disk.DevPath).- Str("model", disk.Model).- Str("health", disk.Health).- Int("wearout", disk.Wearout).- Msg("Checking disk health")-- // If the linked host agent has --disk-exclude patterns that match- // this disk, send a synthetic healthy status to clear any existing- // alerts and skip normal health/wearout checks.- if excludePatterns, ok := diskExcludeByNode[node.Node]; ok {- if fsfilters.MatchesDeviceExclude(disk.DevPath, excludePatterns) {- healthyDisk := disk- healthyDisk.Health = "PASSED"- healthyDisk.Wearout = 100- m.alertManager.CheckDiskHealth(inst, node.Node, healthyDisk)- continue- }- }-- normalizedHealth := strings.ToUpper(strings.TrimSpace(disk.Health))- if normalizedHealth != "" && normalizedHealth != "UNKNOWN" && normalizedHealth != "PASSED" && normalizedHealth != "OK" {- // Disk has failed or is failing - alert manager will handle this- log.Warn().- Str("node", node.Node).- Str("disk", disk.DevPath).- Str("model", disk.Model).- Str("health", disk.Health).- Int("wearout", disk.Wearout).- Msg("Disk health issue detected")-- // Pass disk info to alert manager- m.alertManager.CheckDiskHealth(inst, node.Node, disk)- } else if disk.Wearout > 0 && disk.Wearout < 10 {- // Low wearout warning (less than 10% life remaining)- log.Warn().- Str("node", node.Node).- Str("disk", disk.DevPath).- Str("model", disk.Model).- Int("wearout", disk.Wearout).- Msg("SSD wearout critical - less than 10% life remaining")-- // Pass to alert manager for wearout alert- m.alertManager.CheckDiskHealth(inst, node.Node, disk)- }}}@@ -894,6 +847,29 @@ func (m *Monitor) maybePollPhysicalDisksAsync(allDisks = mergeNVMeTempsIntoDisks(allDisks, nodesFromState)allDisks = mergeHostAgentSMARTIntoDisks(allDisks, nodesFromState, hosts)+ for _, disk := range allDisks {+ if !polledNodes[disk.Node] {+ continue+ }++ log.Debug().+ Str("node", disk.Node).+ Str("disk", disk.DevPath).+ Str("model", disk.Model).+ Str("health", disk.Health).+ Int("wearout", disk.Wearout).+ Msg("Checking disk health")++ if excludePatterns, ok := diskExcludeByNode[disk.Node]; ok && fsfilters.MatchesDeviceExclude(disk.DevPath, excludePatterns) {+ healthyDisk := proxmoxDiskFromPhysicalDisk(disk)+ healthyDisk.Health = "PASSED"+ healthyDisk.Wearout = 100+ m.alertManager.CheckDiskHealth(inst, disk.Node, healthyDisk)+ continue+ }++ m.alertManager.CheckDiskHealth(inst, disk.Node, proxmoxDiskFromPhysicalDisk(disk))+ }// Write SMART metrics to persistent storeif m.metricsStore != nil {@@ -913,6 +889,21 @@ func (m *Monitor) maybePollPhysicalDisksAsync(}(instanceName, client, nodes, nodeEffectiveStatus, modelNodes)}+func proxmoxDiskFromPhysicalDisk(disk models.PhysicalDisk) proxmox.Disk {+ return proxmox.Disk{+ DevPath: disk.DevPath,+ Model: disk.Model,+ Serial: disk.Serial,+ Type: disk.Type,+ Health: disk.Health,+ Wearout: disk.Wearout,+ Size: disk.Size,+ RPM: disk.RPM,+ Used: disk.Used,+ WWN: disk.WWN,+ }+}+// pollPVEInstance polls a single PVE instancefunc (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, client PVEClientInterface) {defer recoverFromPanic(fmt.Sprintf("pollPVEInstance-%s", instanceName))