Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Ignore read-only guest filesystems in disk aggregation
rcourtman78889ffedca3
diff --git a/docs/VM_DISK_MONITORING.md b/docs/VM_DISK_MONITORING.mdindex dce6bb7fa5..3cfc823b1b 100644--- a/docs/VM_DISK_MONITORING.md+++ b/docs/VM_DISK_MONITORING.md@@ -243,7 +243,7 @@ The agent reports all mounted filesystems. Pulse automatically filters out:- Special filesystems (proc, sys, tmpfs, devtmpfs, etc.)- Special Windows partitions ("System Reserved")- Bind mounts and overlays-- CD/DVD filesystems (iso9660, CDFS)+- Read-only appliance or optical images (squashfs, erofs, iso9660, CDFS, UDF, cramfs, romfs, fuse.cdfs)Only local disk usage is counted toward the VM's total.diff --git a/internal/monitoring/fs_filters.go b/internal/monitoring/fs_filters.goindex e0bd355da2..efddb19c4a 100644--- a/internal/monitoring/fs_filters.go+++ b/internal/monitoring/fs_filters.go@@ -2,6 +2,19 @@ package monitoringimport "strings"+var readOnlyFilesystemPatterns = []struct {+ reason string+ substrings []string+}{+ {reason: "erofs", substrings: []string{"erofs"}},+ {reason: "squashfs", substrings: []string{"squashfs", "squash-fs"}},+ {reason: "iso9660", substrings: []string{"iso9660"}},+ {reason: "cdfs", substrings: []string{"cdfs"}},+ {reason: "udf", substrings: []string{"udf"}},+ {reason: "cramfs", substrings: []string{"cramfs"}},+ {reason: "romfs", substrings: []string{"romfs"}},+}+// readOnlyFilesystemReason returns a label explaining why a filesystem should be// ignored for usage calculations, along with a boolean indicating whether it is// a read-only filesystem that always reports full usage. This helps us avoid@@ -14,23 +27,12 @@ func readOnlyFilesystemReason(fsType string, totalBytes, usedBytes uint64) (stri}// Common read-only filesystem types used for immutable system partitions.- if strings.Contains(ft, "erofs") {- return "erofs", true- }- if strings.Contains(ft, "squashfs") || strings.Contains(ft, "squash-fs") {- return "squashfs", true- }- if strings.Contains(ft, "iso9660") {- return "iso9660", true- }- if strings.Contains(ft, "udf") {- return "udf", true- }- if strings.Contains(ft, "cramfs") {- return "cramfs", true- }- if strings.Contains(ft, "romfs") {- return "romfs", true+ for _, pattern := range readOnlyFilesystemPatterns {+ for _, needle := range pattern.substrings {+ if strings.Contains(ft, needle) {+ return pattern.reason, true+ }+ }}// Overlay-style filesystems can report 100% usage even though writes arediff --git a/internal/monitoring/fs_filters_test.go b/internal/monitoring/fs_filters_test.goindex e309eab65f..352f19a76b 100644--- a/internal/monitoring/fs_filters_test.go+++ b/internal/monitoring/fs_filters_test.go@@ -51,6 +51,54 @@ func TestReadOnlyFilesystemReason(t *testing.T) {reason: "squashfs",skip: true,},+ {+ name: "iso9660 filesystem",+ fsType: "iso9660",+ totalBytes: 700 * 1024 * 1024,+ usedBytes: 700 * 1024 * 1024,+ reason: "iso9660",+ skip: true,+ },+ {+ name: "cdfs filesystem",+ fsType: "CDFS",+ totalBytes: 600 * 1024 * 1024,+ usedBytes: 600 * 1024 * 1024,+ reason: "cdfs",+ skip: true,+ },+ {+ name: "udf optical media",+ fsType: "udf",+ totalBytes: 4 * 1024 * 1024 * 1024,+ usedBytes: 4 * 1024 * 1024 * 1024,+ reason: "udf",+ skip: true,+ },+ {+ name: "cramfs image",+ fsType: "cramfs",+ totalBytes: 128 * 1024 * 1024,+ usedBytes: 128 * 1024 * 1024,+ reason: "cramfs",+ skip: true,+ },+ {+ name: "romfs firmware partition",+ fsType: "romfs",+ totalBytes: 16 * 1024 * 1024,+ usedBytes: 16 * 1024 * 1024,+ reason: "romfs",+ skip: true,+ },+ {+ name: "fuse iso image",+ fsType: "fuse.cdfs",+ totalBytes: 700 * 1024 * 1024,+ usedBytes: 700 * 1024 * 1024,+ reason: "cdfs",+ skip: true,+ },{name: "overlay below capacity",fsType: "overlay",