Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Keep platform metric alerts through Proxmox node cleanup
rcourtman7a8376c055a4
diff --git a/docs/release-control/v6/internal/subsystems/alerts.md b/docs/release-control/v6/internal/subsystems/alerts.mdindex 2690c5f5ea..3509cfddf1 100644--- a/docs/release-control/v6/internal/subsystems/alerts.md+++ b/docs/release-control/v6/internal/subsystems/alerts.md@@ -1842,6 +1842,23 @@ well as its alerts.`internal/alerts/host_unraid_lifecycle_test.go` pins the clear, the holds, therestarted count and the pending-run and count cleanup.+### Proxmox node cleanup keeps platform metric alerts++`CleanupAlertsForNodes` runs on every Proxmox node poll (and every mock alert+tick) and removes alerts whose `Node` is not a current Proxmox node or PBS+instance. Kubernetes, TrueNAS and vSphere metric alerts carry a cluster or+platform host in `Node` and a display label such as `TrueNAS Disk` or+`Kubernetes Pod` in `metadata.resourceType`, which the preserve list's+platform words never matched. The cleanup used to delete them silently on+each poll while their reducer incident stayed firing, so the next evaluation+re-created each one and handed it to the alert callback again as a new+alert. `shouldPreserveAlertOutsideNodeCleanup` now keeps any alert carrying+`metadata.platformType`, or whose label maps through+`CanonicalAlertResourceType` to a Kubernetes, TrueNAS or vSphere type.+`TestCleanupAlertsForNodesKeepsPlatformMetricAlerts` in+`internal/alerts/alerts_test.go` pins both signals, and its+sibling pins that a guest alert on a removed Proxmox node is still removed.+### Configured flapping thresholds remain reachableEvery accepted positive `FlappingThreshold`, including values above ten, mustdiff --git a/internal/alerts/active_cleanup.go b/internal/alerts/active_cleanup.goindex 4da24fa05d..2fdfcd34fc 100644--- a/internal/alerts/active_cleanup.go+++ b/internal/alerts/active_cleanup.go@@ -4,6 +4,7 @@ import ("strings""time"+ alertconfig "github.com/rcourtman/pulse-go-rewrite/internal/alerts/config"alertspecs "github.com/rcourtman/pulse-go-rewrite/internal/alerts/specs""github.com/rcourtman/pulse-go-rewrite/internal/unifiedresources""github.com/rs/zerolog/log"@@ -264,6 +265,15 @@ func shouldPreserveAlertOutsideNodeCleanup(alertID string, alert *Alert) bool {if alert.CanonicalKind == string(alertspecs.AlertSpecKindProviderIncident) {return true}+ // Kubernetes, TrueNAS and vSphere metric alerts carry a display label such+ // as "TrueNAS Disk" or "Kubernetes Pod" in resourceType, which the platform+ // words below never matched, and a cluster or host in Node rather than a+ // Proxmox node. Every Proxmox poll used to delete them silently, and the+ // next evaluation raised them again as new alerts.+ if metadataStringValue(alert.Metadata, alertPlatformTypeKey) != "" ||+ isUnifiedModernPlatformAlertType(alertconfig.CanonicalAlertResourceType(alertMetadataResourceType(alert))) {+ return true+ }switch alertMetadataResourceType(alert) {case string(unifiedresources.ResourceTypeAgent),diff --git a/internal/alerts/alerts_test.go b/internal/alerts/alerts_test.goindex f4c4463c5e..f0ad060e0f 100644--- a/internal/alerts/alerts_test.go+++ b/internal/alerts/alerts_test.go@@ -12628,6 +12628,82 @@ func TestCleanupAlertsForNodes(t *testing.T) {})}+// TestCleanupAlertsForNodesKeepsPlatformMetricAlerts pins that the Proxmox+// node cleanup, which runs on every Proxmox poll, leaves Kubernetes, TrueNAS+// and vSphere metric alerts alone. Their Node is a cluster or platform host,+// never a Proxmox node, and their resourceType is a display label.+func TestCleanupAlertsForNodesKeepsPlatformMetricAlerts(t *testing.T) {+ m := newTestManager(t)+ configureUnifiedEvalManager(t, m, unifiedEvalBaseConfig())++ inputs := []*UnifiedResourceInput{+ {ID: "physical-disk:truenas-main/sda", Type: "truenas-disk", Name: "sda", Node: "truenas-main", Instance: "TrueNAS", Temperature: &UnifiedResourceMetric{Value: 80, Percent: 80}},+ {ID: "storage:truenas-main/pool:tank", Type: "truenas-pool", Name: "tank", Node: "truenas-main", Instance: "TrueNAS", Disk: &UnifiedResourceMetric{Percent: 95}},+ {ID: "k8s:prod:pod:api", Type: "pod", Name: "api", Node: "k8s-node-1", Instance: "prod", CPU: &UnifiedResourceMetric{Percent: 99}},+ {ID: "vmware:vc:vm:app-01", Type: "vmware-vm", Name: "app-01", Node: "esxi-01", Instance: "vc", CPU: &UnifiedResourceMetric{Percent: 99}},+ }+ for _, input := range inputs {+ m.CheckUnifiedResource(input)+ }+ platformAlerts := alertKeys(m)+ if len(platformAlerts) != len(inputs) {+ t.Fatalf("expected one alert per platform resource, got %v", platformAlerts)+ }++ m.CleanupAlertsForNodes(map[string]bool{"pve1": true})++ for _, alertID := range platformAlerts {+ if _, exists := testLookupActiveAlert(t, m, alertID); !exists {+ t.Fatalf("Proxmox node cleanup removed platform alert %q; remaining %v", alertID, alertKeys(m))+ }+ }++ // The platform id alone keeps an alert whose label is not recognised.+ m.mu.Lock()+ labels := make(map[*Alert]interface{}, len(m.activeAlerts))+ for _, alert := range m.activeAlerts {+ labels[alert] = alert.Metadata["resourceType"]+ alert.Metadata["resourceType"] = "Unrecognised"+ }+ m.mu.Unlock()+ m.CleanupAlertsForNodes(map[string]bool{"pve1": true})+ if got := alertKeys(m); len(got) != len(platformAlerts) {+ t.Fatalf("platform alerts removed despite their platformType: %v", got)+ }+ m.mu.Lock()+ for alert, label := range labels {+ alert.Metadata["resourceType"] = label+ }+ m.mu.Unlock()++ // A legacy-shaped alert whose metadata predates platformType is still kept+ // by its display label.+ m.mu.Lock()+ for _, alert := range m.activeAlerts {+ delete(alert.Metadata, alertPlatformTypeKey)+ }+ m.mu.Unlock()+ m.CleanupAlertsForNodes(map[string]bool{"pve1": true})+ if got := alertKeys(m); len(got) != len(platformAlerts) {+ t.Fatalf("display-label platform alerts removed without platformType: %v", got)+ }+}++// The cleanup still removes a Proxmox guest alert whose node left the estate.+func TestCleanupAlertsForNodesStillRemovesMissingProxmoxNodeAlerts(t *testing.T) {+ m := newTestManager(t)+ configureUnifiedEvalManager(t, m, unifiedEvalBaseConfig())++ m.CheckUnifiedResource(&UnifiedResourceInput{ID: "pve-gone:node-gone:101", Type: "vm", Name: "vm-101", Node: "node-gone", Instance: "pve-gone", CPU: &UnifiedResourceMetric{Percent: 99}})+ if len(alertKeys(m)) != 1 {+ t.Fatalf("expected the guest CPU alert, got %v", alertKeys(m))+ }+ m.CleanupAlertsForNodes(map[string]bool{"pve1": true})+ if got := alertKeys(m); len(got) != 0 {+ t.Fatalf("guest alert on a removed node survived cleanup: %v", got)+ }+}+func TestCheckZFSPoolHealth(t *testing.T) {// t.Parallel()poolStateAlertID := buildCanonicalStateID("local-zfs/zfs-pool:rpool", "local-zfs/zfs-pool:rpool-state")