Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Refine Proxmox node memory fallback (#582)
rcourtman7ae393c8ec09
diff --git a/internal/monitoring/diagnostic_snapshots.go b/internal/monitoring/diagnostic_snapshots.goindex 9f02aa2103..db8a937073 100644--- a/internal/monitoring/diagnostic_snapshots.go+++ b/internal/monitoring/diagnostic_snapshots.go@@ -21,6 +21,9 @@ type NodeMemoryRaw struct {Cached uint64 `json:"cached"`Shared uint64 `json:"shared"`EffectiveAvailable uint64 `json:"effectiveAvailable"`+ RRDAvailable uint64 `json:"rrdAvailable,omitempty"`+ RRDUsed uint64 `json:"rrdUsed,omitempty"`+ RRDTotal uint64 `json:"rrdTotal,omitempty"`TotalMinusUsed uint64 `json:"totalMinusUsed,omitempty"`FallbackTotal uint64 `json:"fallbackTotal,omitempty"`FallbackUsed uint64 `json:"fallbackUsed,omitempty"`@@ -138,6 +141,15 @@ func (m *Monitor) logNodeMemorySource(instance, node string, snapshot NodeMemoryif snapshot.Raw.TotalMinusUsed > 0 {evt = evt.Uint64("rawTotalMinusUsed", snapshot.Raw.TotalMinusUsed)}+ if snapshot.Raw.RRDAvailable > 0 {+ evt = evt.Uint64("rrdAvailable", snapshot.Raw.RRDAvailable)+ }+ if snapshot.Raw.RRDUsed > 0 {+ evt = evt.Uint64("rrdUsed", snapshot.Raw.RRDUsed)+ }+ if snapshot.Raw.RRDTotal > 0 {+ evt = evt.Uint64("rrdTotal", snapshot.Raw.RRDTotal)+ }if snapshot.Memory.Total > 0 {evt = evt.Int64("total", snapshot.Memory.Total)}diff --git a/internal/monitoring/monitor.go b/internal/monitoring/monitor.goindex 48d1bd1ad3..6f597e9cec 100644--- a/internal/monitoring/monitor.go+++ b/internal/monitoring/monitor.go@@ -475,7 +475,9 @@ type Monitor struct {}type rrdMemCacheEntry struct {- value uint64+ available uint64+ used uint64+ total uint64fetchedAt time.Time}@@ -569,9 +571,9 @@ type taskOutcome struct {recordedAt time.Time}-func (m *Monitor) getNodeRRDMemAvailable(ctx context.Context, client PVEClientInterface, nodeName string) (uint64, error) {+func (m *Monitor) getNodeRRDMetrics(ctx context.Context, client PVEClientInterface, nodeName string) (rrdMemCacheEntry, error) {if client == nil || nodeName == "" {- return 0, fmt.Errorf("invalid arguments for RRD lookup")+ return rrdMemCacheEntry{}, fmt.Errorf("invalid arguments for RRD lookup")}now := time.Now()@@ -579,51 +581,67 @@ func (m *Monitor) getNodeRRDMemAvailable(ctx context.Context, client PVEClientInm.rrdCacheMu.RLock()if entry, ok := m.nodeRRDMemCache[nodeName]; ok && now.Sub(entry.fetchedAt) < nodeRRDCacheTTL {m.rrdCacheMu.RUnlock()- return entry.value, nil+ return entry, nil}m.rrdCacheMu.RUnlock()requestCtx, cancel := context.WithTimeout(ctx, nodeRRDRequestTimeout)defer cancel()- points, err := client.GetNodeRRDData(requestCtx, nodeName, "hour", "AVERAGE", []string{"memavailable", "memtotal"})+ points, err := client.GetNodeRRDData(requestCtx, nodeName, "hour", "AVERAGE", []string{"memavailable", "memused", "memtotal"})if err != nil {- return 0, err+ return rrdMemCacheEntry{}, err}var memAvailable uint64+ var memUsed uint64var memTotal uint64for i := len(points) - 1; i >= 0; i-- {point := points[i]- if point.MemTotal != nil && !math.IsNaN(*point.MemTotal) && *point.MemTotal > 0 {++ if memTotal == 0 && point.MemTotal != nil && !math.IsNaN(*point.MemTotal) && *point.MemTotal > 0 {memTotal = uint64(math.Round(*point.MemTotal))}- if point.MemAvailable == nil || math.IsNaN(*point.MemAvailable) || *point.MemAvailable <= 0 {- continue+ if memAvailable == 0 && point.MemAvailable != nil && !math.IsNaN(*point.MemAvailable) && *point.MemAvailable > 0 {+ memAvailable = uint64(math.Round(*point.MemAvailable))+ }++ if memUsed == 0 && point.MemUsed != nil && !math.IsNaN(*point.MemUsed) && *point.MemUsed > 0 {+ memUsed = uint64(math.Round(*point.MemUsed))}- memAvailable = uint64(math.Round(*point.MemAvailable))- break+ if memTotal > 0 && (memAvailable > 0 || memUsed > 0) {+ break+ }}- if memAvailable == 0 {- return 0, fmt.Errorf("rrd memavailable not present")+ if memTotal > 0 {+ if memAvailable > memTotal {+ memAvailable = memTotal+ }+ if memUsed > memTotal {+ memUsed = memTotal+ }}- if memTotal > 0 && memAvailable > memTotal {- memAvailable = memTotal+ if memAvailable == 0 && memUsed == 0 {+ return rrdMemCacheEntry{}, fmt.Errorf("rrd mem metrics not present")}- m.rrdCacheMu.Lock()- m.nodeRRDMemCache[nodeName] = rrdMemCacheEntry{- value: memAvailable,+ entry := rrdMemCacheEntry{+ available: memAvailable,+ used: memUsed,+ total: memTotal,fetchedAt: now,}++ m.rrdCacheMu.Lock()+ m.nodeRRDMemCache[nodeName] = entrym.rrdCacheMu.Unlock()- return memAvailable, nil+ return entry, nil}// RemoveDockerHost removes a docker host from the shared state and clears related alerts.@@ -3670,7 +3688,6 @@ func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, clieif nodeInfo.Memory != nil && nodeInfo.Memory.Total > 0 {var actualUsed uint64effectiveAvailable := nodeInfo.Memory.EffectiveAvailable()- usedRRDFallback := falsecomponentAvailable := nodeInfo.Memory.Freeif nodeInfo.Memory.Buffers > 0 {if math.MaxUint64-componentAvailable < nodeInfo.Memory.Buffers {@@ -3701,10 +3718,22 @@ func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, clienodeInfo.Memory.Buffers == 0 &&nodeInfo.Memory.Cached == 0+ var rrdMetrics rrdMemCacheEntry+ haveRRDMetrics := false+ usedRRDAvailableFallback := false+ rrdMemUsedFallback := false+if effectiveAvailable == 0 && missingCacheMetrics {- if memAvail, err := m.getNodeRRDMemAvailable(ctx, client, node.Node); err == nil && memAvail > 0 {- effectiveAvailable = memAvail- usedRRDFallback = true+ if metrics, err := m.getNodeRRDMetrics(ctx, client, node.Node); err == nil {+ haveRRDMetrics = true+ rrdMetrics = metrics+ if metrics.available > 0 {+ effectiveAvailable = metrics.available+ usedRRDAvailableFallback = true+ }+ if metrics.used > 0 {+ rrdMemUsedFallback = true+ }} else if err != nil {log.Debug().Err(err).@@ -3723,7 +3752,7 @@ func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, clie}}- derivedFromTotalMinusUsed := !usedRRDFallback &&+ derivedFromTotalMinusUsed := !usedRRDAvailableFallback &&missingCacheMetrics &&availableFromUsed > 0 &&gapGreaterThanComponents &&@@ -3743,7 +3772,10 @@ func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, clieUint64("effectiveAvailable", effectiveAvailable).Uint64("actualUsed", actualUsed).Float64("usage", safePercentage(float64(actualUsed), float64(nodeInfo.Memory.Total)))- if usedRRDFallback {+ if usedRRDAvailableFallback {+ if haveRRDMetrics && rrdMetrics.available > 0 {+ logCtx = logCtx.Uint64("rrdAvailable", rrdMetrics.available)+ }logCtx.Msg("Node memory: using RRD memavailable fallback (excludes reclaimable cache)")nodeMemorySource = "rrd-memavailable"nodeFallbackReason = "rrd-memavailable"@@ -3775,20 +3807,44 @@ func (m *Monitor) pollPVEInstance(ctx context.Context, instanceName string, clienodeMemorySource = "derived-free-buffers-cached"}default:- // Fallback to traditional used memory if no cache-aware data is exposed- actualUsed = nodeInfo.Memory.Used- if actualUsed > nodeInfo.Memory.Total {- actualUsed = nodeInfo.Memory.Total+ switch {+ case rrdMemUsedFallback && haveRRDMetrics && rrdMetrics.used > 0:+ actualUsed = rrdMetrics.used+ if actualUsed > nodeInfo.Memory.Total {+ actualUsed = nodeInfo.Memory.Total+ }+ log.Debug().+ Str("node", node.Node).+ Uint64("total", nodeInfo.Memory.Total).+ Uint64("rrdUsed", rrdMetrics.used).+ Msg("Node memory: using RRD memused fallback (excludes reclaimable cache)")+ nodeMemorySource = "rrd-memused"+ if nodeFallbackReason == "" {+ nodeFallbackReason = "rrd-memused"+ }+ nodeSnapshotRaw.FallbackCalculated = true+ nodeSnapshotRaw.ProxmoxMemorySource = "rrd-memused"+ default:+ // Fallback to traditional used memory if no cache-aware data is exposed+ actualUsed = nodeInfo.Memory.Used+ if actualUsed > nodeInfo.Memory.Total {+ actualUsed = nodeInfo.Memory.Total+ }+ log.Debug().+ Str("node", node.Node).+ Uint64("total", nodeInfo.Memory.Total).+ Uint64("used", actualUsed).+ Msg("Node memory: no cache-aware metrics - using traditional calculation (includes cache)")+ nodeMemorySource = "node-status-used"}- log.Debug().- Str("node", node.Node).- Uint64("total", nodeInfo.Memory.Total).- Uint64("used", actualUsed).- Msg("Node memory: no cache-aware metrics - using traditional calculation (includes cache)")- nodeMemorySource = "node-status-used"}nodeSnapshotRaw.EffectiveAvailable = effectiveAvailable+ if haveRRDMetrics {+ nodeSnapshotRaw.RRDAvailable = rrdMetrics.available+ nodeSnapshotRaw.RRDUsed = rrdMetrics.used+ nodeSnapshotRaw.RRDTotal = rrdMetrics.total+ }free := int64(nodeInfo.Memory.Total - actualUsed)if free < 0 {diff --git a/internal/monitoring/monitor_memory_test.go b/internal/monitoring/monitor_memory_test.gonew file mode 100644index 0000000000..2f35070487--- /dev/null+++ b/internal/monitoring/monitor_memory_test.go@@ -0,0 +1,178 @@+package monitoring++import (+ "context"+ "math"+ "testing"+ "time"++ "github.com/rcourtman/pulse-go-rewrite/internal/alerts"+ "github.com/rcourtman/pulse-go-rewrite/internal/config"+ "github.com/rcourtman/pulse-go-rewrite/internal/models"+ "github.com/rcourtman/pulse-go-rewrite/internal/notifications"+ "github.com/rcourtman/pulse-go-rewrite/pkg/proxmox"+)++type stubPVEClient struct {+ nodes []proxmox.Node+ nodeStatus *proxmox.NodeStatus+ rrdPoints []proxmox.NodeRRDPoint+}++var _ PVEClientInterface = (*stubPVEClient)(nil)++func (s *stubPVEClient) GetNodes(ctx context.Context) ([]proxmox.Node, error) {+ return s.nodes, nil+}++func (s *stubPVEClient) GetNodeStatus(ctx context.Context, node string) (*proxmox.NodeStatus, error) {+ return s.nodeStatus, nil+}++func (s *stubPVEClient) GetNodeRRDData(ctx context.Context, node string, timeframe string, cf string, ds []string) ([]proxmox.NodeRRDPoint, error) {+ return s.rrdPoints, nil+}++func (s *stubPVEClient) GetVMs(ctx context.Context, node string) ([]proxmox.VM, error) {+ return nil, nil+}+func (s *stubPVEClient) GetContainers(ctx context.Context, node string) ([]proxmox.Container, error) {+ return nil, nil+}+func (s *stubPVEClient) GetStorage(ctx context.Context, node string) ([]proxmox.Storage, error) {+ return nil, nil+}+func (s *stubPVEClient) GetAllStorage(ctx context.Context) ([]proxmox.Storage, error) {+ return nil, nil+}+func (s *stubPVEClient) GetBackupTasks(ctx context.Context) ([]proxmox.Task, error) { return nil, nil }+func (s *stubPVEClient) GetStorageContent(ctx context.Context, node, storage string) ([]proxmox.StorageContent, error) {+ return nil, nil+}+func (s *stubPVEClient) GetVMSnapshots(ctx context.Context, node string, vmid int) ([]proxmox.Snapshot, error) {+ return nil, nil+}+func (s *stubPVEClient) GetContainerSnapshots(ctx context.Context, node string, vmid int) ([]proxmox.Snapshot, error) {+ return nil, nil+}+func (s *stubPVEClient) GetVMStatus(ctx context.Context, node string, vmid int) (*proxmox.VMStatus, error) {+ return nil, nil+}+func (s *stubPVEClient) GetContainerStatus(ctx context.Context, node string, vmid int) (*proxmox.Container, error) {+ return nil, nil+}+func (s *stubPVEClient) GetClusterResources(ctx context.Context, resourceType string) ([]proxmox.ClusterResource, error) {+ return nil, nil+}+func (s *stubPVEClient) IsClusterMember(ctx context.Context) (bool, error) { return false, nil }+func (s *stubPVEClient) GetVMFSInfo(ctx context.Context, node string, vmid int) ([]proxmox.VMFileSystem, error) {+ return nil, nil+}+func (s *stubPVEClient) GetVMNetworkInterfaces(ctx context.Context, node string, vmid int) ([]proxmox.VMNetworkInterface, error) {+ return nil, nil+}+func (s *stubPVEClient) GetVMAgentInfo(ctx context.Context, node string, vmid int) (map[string]interface{}, error) {+ return map[string]interface{}{}, nil+}+func (s *stubPVEClient) GetZFSPoolStatus(ctx context.Context, node string) ([]proxmox.ZFSPoolStatus, error) {+ return nil, nil+}+func (s *stubPVEClient) GetZFSPoolsWithDetails(ctx context.Context, node string) ([]proxmox.ZFSPoolInfo, error) {+ return nil, nil+}+func (s *stubPVEClient) GetDisks(ctx context.Context, node string) ([]proxmox.Disk, error) {+ return nil, nil+}+func (s *stubPVEClient) GetCephStatus(ctx context.Context) (*proxmox.CephStatus, error) {+ return nil, nil+}+func (s *stubPVEClient) GetCephDF(ctx context.Context) (*proxmox.CephDF, error) { return nil, nil }++func floatPtr(v float64) *float64 { return &v }++func TestPollPVEInstanceUsesRRDMemUsedFallback(t *testing.T) {+ t.Setenv("PULSE_DATA_DIR", t.TempDir())++ total := uint64(16 * 1024 * 1024 * 1024)+ actualUsed := total / 3++ client := &stubPVEClient{+ nodes: []proxmox.Node{+ {+ Node: "node1",+ Status: "online",+ CPU: 0.15,+ MaxCPU: 8,+ Mem: total,+ MaxMem: total,+ Disk: 0,+ MaxDisk: 0,+ Uptime: 3600,+ },+ },+ nodeStatus: &proxmox.NodeStatus{+ Memory: &proxmox.MemoryStatus{+ Total: total,+ Used: total,+ Free: 0,+ },+ },+ rrdPoints: []proxmox.NodeRRDPoint{+ {+ MemTotal: floatPtr(float64(total)),+ MemUsed: floatPtr(float64(actualUsed)),+ },+ },+ }++ mon := &Monitor{+ config: &config.Config{+ PVEInstances: []config.PVEInstance{+ {+ Name: "test",+ Host: "https://pve",+ },+ },+ },+ state: models.NewState(),+ alertManager: alerts.NewManager(),+ notificationMgr: notifications.NewNotificationManager(""),+ metricsHistory: NewMetricsHistory(32, time.Hour),+ nodeSnapshots: make(map[string]NodeMemorySnapshot),+ guestSnapshots: make(map[string]GuestMemorySnapshot),+ nodeRRDMemCache: make(map[string]rrdMemCacheEntry),+ lastClusterCheck: make(map[string]time.Time),+ lastPhysicalDiskPoll: make(map[string]time.Time),+ }+ defer mon.alertManager.Stop()++ mon.pollPVEInstance(context.Background(), "test", client)++ snapshot := mon.state.GetSnapshot()+ if len(snapshot.Nodes) != 1 {+ t.Fatalf("expected one node in state, got %d", len(snapshot.Nodes))+ }++ node := snapshot.Nodes[0]+ expectedUsage := (float64(actualUsed) / float64(total)) * 100+ if diff := math.Abs(node.Memory.Usage - expectedUsage); diff > 0.5 {+ t.Fatalf("memory usage mismatch: got %.2f want %.2f (diff %.2f)", node.Memory.Usage, expectedUsage, diff)+ }+ if node.Memory.Used != int64(actualUsed) {+ t.Fatalf("memory used mismatch: got %d want %d", node.Memory.Used, actualUsed)+ }++ snapKey := makeNodeSnapshotKey("test", "node1")+ mon.diagMu.RLock()+ snap, ok := mon.nodeSnapshots[snapKey]+ mon.diagMu.RUnlock()+ if !ok {+ t.Fatal("expected node snapshot entry to be recorded")+ }+ if snap.MemorySource != "rrd-memused" {+ t.Fatalf("expected memory source rrd-memused, got %q", snap.MemorySource)+ }+ if snap.Raw.RRDUsed != actualUsed {+ t.Fatalf("expected snapshot RRD used %d, got %d", actualUsed, snap.Raw.RRDUsed)+ }+}