Skip to content

armgit / Pulse

Public Imported from GitHub
0

Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.

Chart the Unraid temperature an agent disk shows

Richard Courtman7b884bc98afc
diff --git a/docs/release-control/v6/internal/subsystems/agent-lifecycle.md b/docs/release-control/v6/internal/subsystems/agent-lifecycle.md
index faec9ec737..1e47117003 100644
--- a/docs/release-control/v6/internal/subsystems/agent-lifecycle.md
+++ b/docs/release-control/v6/internal/subsystems/agent-lifecycle.md
@@ -8806,6 +8806,25 @@ in `internal/monitoring/monitor_host_agents_test.go`
`internal/monitoring/issue1595_collection_trust_test.go`
(`TestAgentDiskHistoryFollowsTheSerialItsUnraidRowReports`).
+### Unraid temperatures chart agent disk history
+
+`internal/monitoring/monitor_agents.go` changed only so the SMART history
+writer charts the temperature a host agent's disk shows. A SMART row without
+its own reading shows the one the host's Unraid inventory reports for the disk,
+when that inventory row describes the disk (`HostSMARTDiskTemperature`), and a
+disk only the Unraid inventory reports,
+such as a member the agent's SMART collection skips under `--disk-exclude`,
+shows that row's reading (`HostUnraidDiskTemperature`). Both are now written
+as `smart_temp` under the key the disk's metrics target reads
+(`HostSMARTDiskMetricID`, `HostUnraidDiskMetricID`); a reading the disk does
+not show as collected, a spun-down disk's or an expired host's, is not. Agent
+registration, enrolment, install, update, removal, report identity and disk
+source IDs are unchanged. Focused proof lives in
+`internal/monitoring/monitor_host_agents_test.go`
+(`TestApplyHostReportChartsUnraidTemperatureOfDiskWithoutSMART`) and
+`internal/monitoring/issue1595_collection_trust_test.go`
+(`TestAgentDiskChartsTheUnraidTemperatureItShows`).
+
### Windows braced MachineGuid does not abort agent startup
The Windows unified agent resolves host information through gopsutil's combined
diff --git a/docs/release-control/v6/internal/subsystems/monitoring.md b/docs/release-control/v6/internal/subsystems/monitoring.md
index 796fc46ca0..1285052caa 100644
--- a/docs/release-control/v6/internal/subsystems/monitoring.md
+++ b/docs/release-control/v6/internal/subsystems/monitoring.md
@@ -4800,8 +4800,10 @@ timeline instead of creating a second drawer-only or mock-only disk history
path.
The SMART-resolved id is the serial the disk resource carries: when a SMART row
reports none, `HostSMARTDiskMetricID` takes the one the host's Unraid inventory
-reports for that disk, as the unified-resources adapter does, unless several
-SMART rows share the disk's device path, and `hostDiskIOMetricResourceID` keys
+reports for that disk, as the unified-resources adapter does, unless the Unraid
+row does not describe the disk (`unraidDiskDescribesSMARTRow`: a controller
+member, or several SMART rows on the disk's device path), and
+`hostDiskIOMetricResourceID` keys
a device with no non-standby SMART row by its Unraid serial
(`HostUnraidDeviceMetricID`, which refuses a device several Unraid rows name)
before the linked Proxmox node's disks and the `<host>:<device>` fallback.
@@ -4812,6 +4814,21 @@ their counter under no member.
Proof:
`TestAgentDiskHistoryFollowsTheSerialItsUnraidRowReports` and
`TestHostDiskIOMetricResourceIDFallbacks`.
+The agent's `smart_temp` series holds the reading the disk resource shows,
+not only the SMART row's own. `writeHostSMARTMetrics` writes
+`HostSMARTDiskTemperature`, which falls back to the host's Unraid inventory
+reading when the row has none, and `writeHostUnraidDiskTemperatures` writes
+`HostUnraidDiskTemperature` under `HostUnraidDiskMetricID` for each Unraid row
+whose key is not one of the host's SMART rows' keys, such as a `--disk-exclude`
+member, so an Unraid reading never overwrites a SMART row's own at the same
+timestamp.
+Unraid rows sharing a key are one disk in the registry, which shows the latest
+of their readings, so the last row with a reading decides that key's single
+sample. `diskinventory.TemperatureCollected` keeps a spun-down disk's or an
+expired host's leftover reading out of history.
+Proof:
+`TestAgentDiskChartsTheUnraidTemperatureItShows` and
+`TestApplyHostReportChartsUnraidTemperatureOfDiskWithoutSMART`.
That same monitoring-owned disk-health boundary also includes shared storage
risk assessment in `internal/storagehealth/`. When providers or host agents
emit structured storage topology such as Unraid per-disk state, the shared
diff --git a/docs/release-control/v6/internal/subsystems/unified-resources.md b/docs/release-control/v6/internal/subsystems/unified-resources.md
index 84269fbcce..826a91d7c7 100644
--- a/docs/release-control/v6/internal/subsystems/unified-resources.md
+++ b/docs/release-control/v6/internal/subsystems/unified-resources.md
@@ -5432,6 +5432,26 @@ A row's own serial is kept even when it is a placeholder, as the
adapter keeps it, and the Unraid row then stays a disk of its own. Proof:
`TestHostSMARTDiskMetricIDTakesTheSerialItsUnraidRowReports`,
`TestAgentDiskHistoryFollowsTheSerialItsUnraidRowReports`.
+The adapters' disk temperature rule is shared with the agent disk history
+writer. `HostSMARTDiskTemperature` returns the temperature and collection state
+a SMART row's disk shows: the row's own reading, or, when it has none, its
+Unraid row's under `unraidDiskTemperatureStatus`. `matchUnraidDisk` finds that
+Unraid row by the SMART row's usable serial anywhere in the inventory before
+any device path, and a placeholder serial matches nothing. The fallback, like
+the serial a row without one takes (`hostSMARTDiskSerial`), comes only from an
+Unraid row that describes the row's disk (`unraidDiskDescribesSMARTRow`): one
+carrying the row's usable serial, or one naming the row's device path when the
+row is that whole kernel block device. A controller member, even the only one
+reported, and a row sharing its path with other SMART rows are not, because
+the Unraid row describes the block device as a whole. `HostUnraidDiskTemperature`
+returns what a disk built from an Unraid row alone shows, and
+`HostUnraidDiskMetricID` returns the key that disk's metrics target reads: its
+usable serial, else its `HostUnraidDiskSourceID`, and nothing for a row without
+a device, which is not ingested. The writer used to take only the SMART row's
+own reading, so a temperature shown from the Unraid inventory, for a disk whose
+SMART probe returned none or one excluded from SMART collection, was never
+charted. Proof: `TestAgentDiskChartsTheUnraidTemperatureItShows` and
+`TestHostUnraidDiskMetricIDMatchesItsDiskMetricsTarget`.
That same canonical physical-disk view must also expose source-independent host
context. When a disk is API-backed rather than node-backed, typed views should
fall back to canonical host identity such as `identity.hostnames` instead of
diff --git a/internal/monitoring/issue1595_collection_trust_test.go b/internal/monitoring/issue1595_collection_trust_test.go
index 7486e493af..0da88b9821 100644
--- a/internal/monitoring/issue1595_collection_trust_test.go
+++ b/internal/monitoring/issue1595_collection_trust_test.go
@@ -681,6 +681,167 @@ func TestAgentDiskHistoryFollowsTheSerialItsUnraidRowReports(t *testing.T) {
}
}
+// An Unraid host's disk can show a temperature only its Unraid inventory
+// reports: a member the agent's SMART collection skips (--disk-exclude), or
+// one Unraid reads with its own per-disk SMART settings while the agent's
+// probe returns no temperature. The chart must hold the reading the disk
+// shows, under the key its metrics target reads, and nothing for a reading the
+// disk does not show as collected (a spun-down disk, a host past its lease) or
+// does not show at all (a controller member behind the device Unraid reads).
+func TestAgentDiskChartsTheUnraidTemperatureItShows(t *testing.T) {
+ storeConfig := metrics.DefaultConfig(t.TempDir())
+ storeConfig.FlushInterval = time.Hour
+ store, err := metrics.NewStore(storeConfig)
+ if err != nil {
+ t.Fatal(err)
+ }
+ t.Cleanup(func() { _ = store.Close() })
+ m := &Monitor{metricsStore: store, rateTracker: NewRateTracker()}
+
+ now := time.Now().UTC().Truncate(time.Second)
+ host := models.Host{ID: "host-tower", Hostname: "tower", MachineID: "machine-tower", Status: "online", LastSeen: now}
+ host.Sensors.SMART = []models.HostDiskSMART{
+ // The agent's identity-only row for a disk its probe got nothing from.
+ {Device: "sdb", Serial: "SER-B", Health: "UNKNOWN", Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("smartctl", "SMART probe returned no usable temperature data")}},
+ // A row with its own reading keeps it; the Unraid one is not written too.
+ {Device: "sdc", WWN: "0x5000c500aaaa0003", Health: "PASSED", Temperature: 41, Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Available("smartctl")}},
+ // The agent's native standby row for a disk Unraid reports spun down.
+ {Device: "sdd", Serial: "SER-D", Health: "UNKNOWN", Standby: true, Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("unraid", "disk is reported spun down")}},
+ // Controller members behind one kernel block device, which the Unraid
+ // row describes as a whole: neither member takes its temperature.
+ {Device: "sdh", Controller: "sdh", Target: "megaraid,0", WWN: "0x5000c500bbbb0001", Health: "PASSED", Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("smartctl", "SMART probe returned no usable temperature data")}},
+ {Device: "sdh", Controller: "sdh", Target: "megaraid,1", WWN: "0x5000c500bbbb0002", Health: "PASSED", Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("smartctl", "SMART probe returned no usable temperature data")}},
+ // A member whose own serial is the Unraid row's is the disk that row
+ // describes, though its path is shared.
+ {Device: "sdi", Controller: "sdi", Target: "megaraid,0", Serial: "SER-I", Health: "UNKNOWN", Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("smartctl", "SMART probe returned no usable temperature data")}},
+ {Device: "sdi", Controller: "sdi", Target: "megaraid,1", Serial: "SER-I2", Health: "UNKNOWN", Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("smartctl", "SMART probe returned no usable temperature data")}},
+ // A placeholder serial is no evidence of which member the row is.
+ {Device: "sdn", Controller: "sdn", Target: "megaraid,0", Serial: "UNKNOWN", WWN: "0x5000c500cccc0001", Health: "UNKNOWN", Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("smartctl", "SMART probe returned no usable temperature data")}},
+ {Device: "sdn", Controller: "sdn", Target: "megaraid,1", Serial: "UNKNOWN", WWN: "0x5000c500cccc0002", Health: "UNKNOWN", Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("smartctl", "SMART probe returned no usable temperature data")}},
+ // A placeholder serial matches no Unraid row; the row's path finds its own.
+ {Device: "sdo", Serial: "0123456789", WWN: "0x5000c500eeee0001", Health: "UNKNOWN", Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("smartctl", "SMART probe returned no usable temperature data")}},
+ // The only reported member behind a controller path is still a member.
+ {Device: "sdq", Controller: "sdq", Target: "megaraid,0", WWN: "0x5000c500ffff0001", Health: "UNKNOWN", Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("smartctl", "SMART probe returned no usable temperature data")}},
+ // Without a serial or WWN, a member charts its own reading under its
+ // topology key.
+ {Device: "sdr", Controller: "sdr", Target: "megaraid,0", Health: "PASSED", Temperature: 35, Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Available("smartctl")}},
+ // A SMART row's key is its own: the merged disk shows the row's reading,
+ // here not collected, and the Unraid one is not charted over it.
+ {Device: "sdm", WWN: "0x5000c500dddd0001", Health: "PASSED", Temperature: 40, Collection: &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Unavailable("smartctl", "disk is in standby")}},
+ }
+ host.Unraid = &models.HostUnraidStorage{ArrayStarted: true, Disks: []models.HostUnraidDisk{
+ {Device: "sdb", Serial: "SER-B", Name: "disk1", Role: "data", Status: "online", Temperature: 38},
+ {Device: "sdc", Serial: "SER-C", Name: "disk2", Role: "data", Status: "online", Temperature: 39},
+ {Device: "sdd", Serial: "SER-D", Name: "disk3", Role: "data", Status: "online", Temperature: 35, SpunDown: true},
+ // Members with no SMART row at all.
+ {Device: "sde", Serial: "SER-E", Name: "disk4", Role: "data", Status: "online", Temperature: 36},
+ {Device: "sdf", Serial: "SER-F", Name: "disk5", Role: "data", Status: "online", Temperature: 33, SpunDown: true},
+ {Device: "sdg", Name: "disk6", Role: "data", Status: "online", Temperature: 37},
+ {Device: "sdh", Serial: "SER-H", Name: "disk7", Role: "data", Status: "online", Temperature: 42},
+ {Device: "sdi", Serial: "SER-I", Name: "disk8", Role: "data", Status: "online", Temperature: 44},
+ // Rows sharing one history key are one disk, showing the latest reading.
+ {Device: "sdj", Name: "disk9", Role: "data", Status: "online"},
+ {Device: "sdj", Name: "disk10", Role: "data", Status: "online", Temperature: 43},
+ {Device: "sdk", Name: "disk11", Role: "data", Status: "online", Temperature: 38},
+ {Device: "sdk", Name: "disk12", Role: "data", Status: "online", Temperature: 39},
+ {Device: "sdl", Name: "disk13", Role: "data", Status: "online", Temperature: 40},
+ {Device: "sdl", Name: "disk14", Role: "data", Status: "online", Temperature: 32, SpunDown: true},
+ {Device: "sdn", Serial: "UNKNOWN", Name: "disk15", Role: "data", Status: "online", Temperature: 45},
+ {Device: "sdm", Serial: "SER-M", Name: "disk16", Role: "data", Status: "online", Temperature: 37},
+ {Device: "sdp", Serial: "0123456789", Name: "disk17", Role: "data", Status: "online", Temperature: 30},
+ {Device: "sdo", Serial: "0123456789", Name: "disk18", Role: "data", Status: "online", Temperature: 46},
+ {Device: "sdq", Serial: "SER-Q", Name: "disk19", Role: "data", Status: "online", Temperature: 47},
+ {Device: "sdr", Serial: "SER-R", Name: "disk20", Role: "data", Status: "online", Temperature: 36},
+ }}
+ // Disks by usable serial, else WWN, else device path, and the reading each
+ // shows as collected.
+ want := map[string]float64{
+ "SER-B": 38, "SER-C": 41, "SER-D": 0, "SER-E": 36, "SER-F": 0, "sdg": 37,
+ "SER-H": 42, "0x5000c500bbbb0001": 0, "0x5000c500bbbb0002": 0,
+ "SER-I": 44, "SER-I2": 0, "sdj": 43, "sdk": 39, "sdl": 0,
+ "sdn": 45, "0x5000c500cccc0001": 0, "0x5000c500cccc0002": 0, "SER-M": 0,
+ "0x5000c500eeee0001": 46, "sdo": 46, "sdp": 30, "0x5000c500ffff0001": 0, "SER-Q": 47,
+ "sdr": 35, "SER-R": 36,
+ }
+
+ m.writeHostSMARTMetrics(host, now)
+ // Once the host's lease expires its last report is kept, offline, as
+ // context; nothing it carries is a current reading.
+ reported := host
+ reported.Sensors.SMART = append([]models.HostDiskSMART(nil), host.Sensors.SMART...)
+ state := &models.State{Hosts: []models.Host{reported}}
+ offline, expired := state.ExpireHostTelemetry(host.ID, host.LastSeen)
+ if !expired {
+ t.Fatal("host telemetry did not expire")
+ }
+ m.writeHostSMARTMetrics(offline, now.Add(30*time.Second))
+ store.Flush()
+
+ live := unifiedresources.NewRegistry(nil)
+ live.IngestSnapshot(models.StateSnapshot{Hosts: []models.Host{host}})
+ rehydrated := unifiedresources.NewRegistry(nil)
+ rehydrated.IngestResources(live.List())
+ for _, tc := range []struct {
+ name string
+ registry *unifiedresources.ResourceRegistry
+ }{{"live", live}, {"rehydrated", rehydrated}} {
+ disks := tc.registry.ListByType(unifiedresources.ResourceTypePhysicalDisk)
+ if len(disks) != len(want) {
+ t.Fatalf("%s: disks = %d, want %d", tc.name, len(disks), len(want))
+ }
+ for _, disk := range disks {
+ device := disk.PhysicalDisk.Serial
+ if !diskinventory.IsUsableHardwareID(device) {
+ device = ""
+ }
+ if device == "" {
+ device = disk.PhysicalDisk.WWN
+ }
+ if device == "" {
+ device = disk.PhysicalDisk.DevPath
+ }
+ wantTemp, ok := want[device]
+ if !ok {
+ t.Fatalf("%s: unexpected disk %s at %q", tc.name, disk.ID, device)
+ }
+ shown := 0.0
+ if diskinventory.TemperatureCollected(disk.PhysicalDisk.Temperature, disk.PhysicalDisk.Collection) {
+ shown = float64(disk.PhysicalDisk.Temperature)
+ }
+ if shown != wantTemp {
+ t.Fatalf("%s: disk %s shows %v°C as collected, want %v°C", tc.name, device, shown, wantTemp)
+ }
+ target := tc.registry.MetricsTarget(disk.ID)
+ if target == nil {
+ t.Fatalf("%s: disk %s has no metrics target", tc.name, device)
+ }
+ points, err := store.Query(target.ResourceType, target.ResourceID, "smart_temp", now.Add(-time.Minute), now.Add(time.Minute), 0)
+ if err != nil {
+ t.Fatal(err)
+ }
+ switch {
+ case wantTemp == 0 && len(points) != 0:
+ t.Errorf("%s: disk %s shows no collected temperature but target %+v charts %+v", tc.name, device, *target, points)
+ case wantTemp > 0 && (len(points) != 1 || points[0].Value != wantTemp || !points[0].Timestamp.Equal(now)):
+ t.Errorf("%s: disk %s shows %v°C but target %+v charts %+v, want one sample at the online report", tc.name, device, wantTemp, *target, points)
+ }
+ }
+ }
+}
+
// A SMART row found only by device path may describe the slot's previous
// occupant. It is refused when its identity contradicts the Proxmox disk's,
// judged only on what both producers report like for like: WWNs for every
diff --git a/internal/monitoring/monitor_agents.go b/internal/monitoring/monitor_agents.go
index 85599d39e7..598c6b3bd5 100644
--- a/internal/monitoring/monitor_agents.go
+++ b/internal/monitoring/monitor_agents.go
@@ -4081,14 +4081,18 @@ func (m *Monitor) writeHostSMARTMetrics(host models.Host, now time.Time) {
return
}
+ smartMetricIDs := make(map[string]struct{}, len(host.Sensors.SMART))
for _, disk := range host.Sensors.SMART {
resourceID := unifiedresources.HostSMARTDiskMetricID(host, disk)
if resourceID == "" {
continue
}
+ smartMetricIDs[resourceID] = struct{}{}
- if diskinventory.TemperatureCollected(disk.Temperature, disk.Collection) {
- m.metricsStore.Write("disk", resourceID, "smart_temp", float64(disk.Temperature), now)
+ // Chart the reading the disk shows: a row without its own carries the
+ // host's Unraid reading for the disk.
+ if temperature, collection := unifiedresources.HostSMARTDiskTemperature(host, disk); diskinventory.TemperatureCollected(temperature, collection) {
+ m.metricsStore.Write("disk", resourceID, "smart_temp", float64(temperature), now)
}
attrs := disk.Attributes
@@ -4127,6 +4131,50 @@ func (m *Monitor) writeHostSMARTMetrics(host models.Host, now time.Time) {
m.metricsStore.Write("disk", resourceID, "smart_unsafe_shutdowns", float64(*attrs.UnsafeShutdowns), now)
}
}
+
+ m.writeHostUnraidDiskTemperatures(host, smartMetricIDs, now)
+}
+
+// writeHostUnraidDiskTemperatures charts the temperature of each disk only the
+// host's Unraid inventory reports, such as a member the agent's SMART
+// collection skips under --disk-exclude. smartMetricIDs holds the history keys
+// of the host's SMART rows. A disk under one of those keys is that row's to
+// chart, and the row already carries the Unraid reading when it has none of
+// its own. Unraid rows sharing a key are one disk in the registry, which keeps
+// the latest of their readings, so the last row with a reading decides that
+// key's sample.
+func (m *Monitor) writeHostUnraidDiskTemperatures(host models.Host, smartMetricIDs map[string]struct{}, now time.Time) {
+ if host.Unraid == nil {
+ return
+ }
+ type reading struct {
+ temperature int
+ collection *diskinventory.CollectionStatus
+ }
+ var keys []string
+ readings := make(map[string]reading, len(host.Unraid.Disks))
+ for _, disk := range host.Unraid.Disks {
+ resourceID := unifiedresources.HostUnraidDiskMetricID(host, disk)
+ if resourceID == "" {
+ continue
+ }
+ if _, ok := smartMetricIDs[resourceID]; ok {
+ continue
+ }
+ temperature, collection := unifiedresources.HostUnraidDiskTemperature(host, disk)
+ if temperature <= 0 {
+ continue
+ }
+ if _, ok := readings[resourceID]; !ok {
+ keys = append(keys, resourceID)
+ }
+ readings[resourceID] = reading{temperature: temperature, collection: collection}
+ }
+ for _, resourceID := range keys {
+ if r := readings[resourceID]; diskinventory.TemperatureCollected(r.temperature, r.collection) {
+ m.metricsStore.Write("disk", resourceID, "smart_temp", float64(r.temperature), now)
+ }
+ }
}
func normalizeHostDiskDevice(device string) string {
diff --git a/internal/monitoring/monitor_host_agents_test.go b/internal/monitoring/monitor_host_agents_test.go
index baef427792..600be586b6 100644
--- a/internal/monitoring/monitor_host_agents_test.go
+++ b/internal/monitoring/monitor_host_agents_test.go
@@ -3017,6 +3017,71 @@ func TestApplyHostReportPersistsSMARTMetricsForAgentDisks(t *testing.T) {
}
}
+// An Unraid member the agent sends no SMART row for (a --disk-exclude match)
+// still shows the temperature its Unraid inventory row reports, so the report
+// charts it under the disk's serial. A disk with its own SMART reading keeps
+// it, and a spun-down member's leftover reading is not charted.
+func TestApplyHostReportChartsUnraidTemperatureOfDiskWithoutSMART(t *testing.T) {
+ storeCfg := metrics.DefaultConfig(t.TempDir())
+ storeCfg.WriteBufferSize = 1
+ store, err := metrics.NewStore(storeCfg)
+ if err != nil {
+ t.Fatalf("NewStore: %v", err)
+ }
+ defer store.Close()
+
+ monitor := &Monitor{
+ state: models.NewState(),
+ alertManager: alerts.NewManager(),
+ hostTokenBindings: make(map[string]string),
+ config: &config.Config{},
+ rateTracker: NewRateTracker(),
+ metricsStore: store,
+ }
+ t.Cleanup(func() { monitor.alertManager.Stop() })
+
+ report := agentshost.Report{
+ Agent: agentshost.AgentInfo{ID: "agent-tower", Version: "1.0.0", IntervalSeconds: 30},
+ Host: agentshost.HostInfo{ID: "machine-tower", Hostname: "tower", MachineID: "machine-tower"},
+ Metrics: agentshost.Metrics{
+ Memory: agentshost.MemoryMetric{TotalBytes: 1024, UsedBytes: 512, FreeBytes: 512, Usage: 50},
+ },
+ Sensors: agentshost.Sensors{
+ SMART: []agentshost.DiskSMART{
+ {Device: "/dev/sda", Model: "IronWolf", Serial: "SERIAL-TOWER-1", Temperature: 41},
+ },
+ },
+ Unraid: &agentshost.UnraidStorage{ArrayStarted: true, Disks: []agentshost.UnraidDisk{
+ {Name: "disk1", Device: "sda", Role: "data", Status: "online", Serial: "SERIAL-TOWER-1", Temperature: 40},
+ {Name: "disk2", Device: "sdb", Role: "data", Status: "online", Serial: "SERIAL-TOWER-2", Temperature: 36},
+ {Name: "disk3", Device: "sdc", Role: "data", Status: "online", Serial: "SERIAL-TOWER-3", Temperature: 34, SpunDown: true},
+ }},
+ Timestamp: time.Now().UTC(),
+ }
+
+ if _, err := monitor.ApplyHostReport(report, nil); err != nil {
+ t.Fatalf("ApplyHostReport: %v", err)
+ }
+ store.Flush()
+
+ points := waitForStoredDiskMetric(t, store, "SERIAL-TOWER-2", "smart_temp")
+ if len(points) != 1 || points[0].Value != 36 {
+ t.Fatalf("SERIAL-TOWER-2 smart_temp = %+v, want the Unraid reading 36", points)
+ }
+ points = waitForStoredDiskMetric(t, store, "SERIAL-TOWER-1", "smart_temp")
+ if len(points) != 1 || points[0].Value != 41 {
+ t.Fatalf("SERIAL-TOWER-1 smart_temp = %+v, want its own SMART reading 41", points)
+ }
+ now := time.Now().UTC()
+ points, err = store.Query("disk", "SERIAL-TOWER-3", "smart_temp", now.Add(-time.Hour), now.Add(time.Hour), 60)
+ if err != nil {
+ t.Fatalf("Query smart_temp: %v", err)
+ }
+ if len(points) != 0 {
+ t.Fatalf("spun-down SERIAL-TOWER-3 smart_temp = %+v, want none", points)
+ }
+}
+
func TestApplyHostReportPersistsAgentTemperatureMetric(t *testing.T) {
t.Helper()
diff --git a/internal/unifiedresources/adapters.go b/internal/unifiedresources/adapters.go
index 167af4c6b1..e5220c3800 100644
--- a/internal/unifiedresources/adapters.go
+++ b/internal/unifiedresources/adapters.go
@@ -806,10 +806,7 @@ func resourceFromHostUnraidPhysicalDisk(host models.Host, disk models.HostUnraid
health := unraidPhysicalDiskHealth(disk)
assessment := assessUnraidPhysicalDisk(disk)
sizeBytes := unraidDiskSizeBytes(host, disk)
- var collection *diskinventory.CollectionStatus
- if status := unraidDiskTemperatureStatus(host, disk); status.State != "" {
- collection = &diskinventory.CollectionStatus{Temperature: status}
- }
+ temperature, collection := HostUnraidDiskTemperature(host, disk)
resource := Resource{
Type: ResourceTypePhysicalDisk,
Name: name,
@@ -824,7 +821,7 @@ func resourceFromHostUnraidPhysicalDisk(host models.Host, disk models.HostUnraid
SizeBytes: sizeBytes,
Health: health,
Wearout: -1,
- Temperature: disk.Temperature,
+ Temperature: temperature,
Used: unraidDiskMountPath(disk),
StorageRole: unraidDiskRole(&disk),
StorageGroup: unraidDiskGroup(&disk),
@@ -869,6 +866,46 @@ func unraidDiskTemperatureStatus(host models.Host, disk models.HostUnraidDisk) d
}
}
+// HostUnraidDiskTemperature returns the temperature the disk resource built
+// from a host's Unraid inventory row shows, with its collection state. The
+// agent disk history writer charts this reading.
+func HostUnraidDiskTemperature(host models.Host, disk models.HostUnraidDisk) (int, *diskinventory.CollectionStatus) {
+ status := unraidDiskTemperatureStatus(host, disk)
+ if status.State == "" {
+ return disk.Temperature, nil
+ }
+ return disk.Temperature, &diskinventory.CollectionStatus{Temperature: status}
+}
+
+// HostSMARTDiskTemperature returns the temperature the disk resource built
+// from a host agent's SMART row shows, with its collection state. The agent
+// disk history writer charts this reading.
+func HostSMARTDiskTemperature(host models.Host, disk models.HostDiskSMART) (int, *diskinventory.CollectionStatus) {
+ return hostSMARTDiskTemperature(host, disk, matchUnraidDisk(host.Unraid, disk))
+}
+
+// hostSMARTDiskTemperature returns the temperature the disk resource built
+// from a host agent's SMART row shows, with the row's collection state: the
+// row's own reading, or, when the row has none, the one the host's Unraid
+// inventory reports for the disk. Unraid reads its members' temperatures with
+// its own per-disk SMART settings, so it can have one when the agent's probe
+// returned none. The reading is taken only from an Unraid row that describes
+// the row's disk (unraidDiskDescribesSMARTRow).
+func hostSMARTDiskTemperature(host models.Host, disk models.HostDiskSMART, unraidDisk *models.HostUnraidDisk) (int, *diskinventory.CollectionStatus) {
+ collection := diskinventory.CloneStatus(disk.Collection)
+ if disk.Temperature > 0 || !unraidDiskDescribesSMARTRow(host, disk, unraidDisk) {
+ return disk.Temperature, collection
+ }
+ // The reading is now the Unraid inventory's, and so is its state.
+ if status := unraidDiskTemperatureStatus(host, *unraidDisk); status.State != "" {
+ if collection == nil {
+ collection = &diskinventory.CollectionStatus{}
+ }
+ collection.Temperature = status
+ }
+ return unraidDisk.Temperature, collection
+}
+
func resourceFromHostSMARTDisk(host models.Host, disk models.HostDiskSMART) (Resource, ResourceIdentity) {
name := strings.TrimSpace(disk.Model)
if name == "" {
@@ -907,8 +944,7 @@ func resourceFromHostSMARTDisk(host models.Host, disk models.HostDiskSMART) (Res
model := strings.TrimSpace(disk.Model)
serial := hostSMARTDiskSerial(host, disk, unraidDisk)
diskType := strings.TrimSpace(disk.Type)
- temperature := disk.Temperature
- collection := diskinventory.CloneStatus(disk.Collection)
+ temperature, collection := hostSMARTDiskTemperature(host, disk, unraidDisk)
health := strings.TrimSpace(disk.Health)
if unraidDisk != nil {
if model == "" {
@@ -920,16 +956,6 @@ func resourceFromHostSMARTDisk(host models.Host, disk models.HostDiskSMART) (Res
if sizeBytes <= 0 {
sizeBytes = unraidDiskSizeBytes(host, *unraidDisk)
}
- if temperature <= 0 {
- temperature = unraidDisk.Temperature
- // The reading is now the Unraid inventory's, and so is its state.
- if status := unraidDiskTemperatureStatus(host, *unraidDisk); status.State != "" {
- if collection == nil {
- collection = &diskinventory.CollectionStatus{}
- }
- collection.Temperature = status
- }
- }
if health == "" || strings.EqualFold(health, "UNKNOWN") {
health = unraidPhysicalDiskHealth(*unraidDisk)
}
@@ -1219,21 +1245,30 @@ func maxInt64() int64 {
return int64(^uint64(0) >> 1)
}
+// matchUnraidDisk returns the host's Unraid row for a SMART row: the one
+// carrying the row's usable serial, else the one at its device path. A serial
+// names the drive and a path only where the kernel put it, so a serial match
+// anywhere in the inventory outranks a path match. A placeholder serial, which
+// several bridges report alike, is no match at all.
func matchUnraidDisk(unraid *models.HostUnraidStorage, disk models.HostDiskSMART) *models.HostUnraidDisk {
if unraid == nil || len(unraid.Disks) == 0 {
return nil
}
+ if serial := strings.TrimSpace(disk.Serial); diskinventory.IsUsableHardwareID(serial) {
+ for i := range unraid.Disks {
+ if strings.EqualFold(strings.TrimSpace(unraid.Disks[i].Serial), serial) {
+ return &unraid.Disks[i]
+ }
+ }
+ }
normalizedDevice := strings.ToLower(normalizePhysicalDiskDeviceToken(disk.Device))
- normalizedSerial := strings.TrimSpace(strings.ToLower(disk.Serial))
+ if normalizedDevice == "" {
+ return nil
+ }
for i := range unraid.Disks {
- candidate := &unraid.Disks[i]
- if normalizedSerial != "" && strings.EqualFold(strings.TrimSpace(candidate.Serial), normalizedSerial) {
- return candidate
- }
- candidateDevice := strings.ToLower(normalizePhysicalDiskDeviceToken(candidate.Device))
- if normalizedDevice != "" && candidateDevice != "" && candidateDevice == normalizedDevice {
- return candidate
+ if strings.ToLower(normalizePhysicalDiskDeviceToken(unraid.Disks[i].Device)) == normalizedDevice {
+ return &unraid.Disks[i]
}
}
return nil
diff --git a/internal/unifiedresources/canonical_ids_types_test.go b/internal/unifiedresources/canonical_ids_types_test.go
index c8ed1bedb5..edd8be0863 100644
--- a/internal/unifiedresources/canonical_ids_types_test.go
+++ b/internal/unifiedresources/canonical_ids_types_test.go
@@ -503,6 +503,50 @@ func TestHostUnraidDiskSourceIDNormalizesDeviceAndPrefersSerial(t *testing.T) {
}
}
+// An Unraid inventory row's history key is the one the metrics target of the
+// disk resource built from it reads: its usable serial, unscoped like every
+// physical-disk history key, or else its host/device source ID. A row without
+// a device is not ingested as a disk and has no key.
+func TestHostUnraidDiskMetricIDMatchesItsDiskMetricsTarget(t *testing.T) {
+ host := models.Host{ID: "host-tower", Hostname: "tower"}
+ tests := []struct {
+ name string
+ disk models.HostUnraidDisk
+ want string
+ }{
+ {"serial", models.HostUnraidDisk{Device: "/dev/sdb", Serial: "SERIAL-DATA"}, "SERIAL-DATA"},
+ {"placeholder serial", models.HostUnraidDisk{Device: "sdc", Serial: "N/A"}, "host-tower:sdc"},
+ {"no serial", models.HostUnraidDisk{Device: "sdd [sat]"}, "host-tower:sdd"},
+ {"no device", models.HostUnraidDisk{Name: "disk9", Serial: "SERIAL-MISSING"}, ""},
+ }
+ for _, tt := range tests {
+ t.Run(tt.name, func(t *testing.T) {
+ got := HostUnraidDiskMetricID(host, tt.disk)
+ if got != tt.want {
+ t.Fatalf("HostUnraidDiskMetricID(%+v) = %q, want %q", tt.disk, got, tt.want)
+ }
+ if tt.want == "" {
+ return
+ }
+ disk := tt.disk
+ disk.Name, disk.Role, disk.Status = "disk1", "data", "online"
+ registry := NewRegistry(nil)
+ registry.IngestSnapshot(models.StateSnapshot{Hosts: []models.Host{{
+ ID: host.ID, Hostname: host.Hostname, Status: "online",
+ Unraid: &models.HostUnraidStorage{ArrayStarted: true, Disks: []models.HostUnraidDisk{disk}},
+ }}})
+ disks := registry.ListByType(ResourceTypePhysicalDisk)
+ if len(disks) != 1 {
+ t.Fatalf("disks = %d, want 1", len(disks))
+ }
+ target := registry.MetricsTarget(disks[0].ID)
+ if target == nil || target.ResourceType != "disk" || target.ResourceID != got {
+ t.Fatalf("metrics target = %+v, want disk %q", target, got)
+ }
+ })
+ }
+}
+
// An agent disk's source ID carries its host, because a usable serial or WWN
// names the drive but not the machine; its metrics key is the hardware ID
// alone. Without hardware identity the two keep one host/device/topology key.
diff --git a/internal/unifiedresources/physical_disk_ids.go b/internal/unifiedresources/physical_disk_ids.go
index 4ba7cefa98..9d210e9e8c 100644
--- a/internal/unifiedresources/physical_disk_ids.go
+++ b/internal/unifiedresources/physical_disk_ids.go
@@ -61,17 +61,37 @@ func hostSMARTDiskKey(host models.Host, disk models.HostDiskSMART, serial, wwn s
// row's own, or, when the row reports none, the one the host's Unraid
// inventory reports for the disk. smartctl reports no serial for a disk in
// standby, and the Unraid row still names it. A row without a serial matches
-// its Unraid row by device path alone, so it takes no serial from a path
-// several of the host's rows share: controller members behind one kernel block
-// device, which the Unraid row describes as a whole.
+// its Unraid row by device path alone, so it takes the serial only where that
+// row describes its disk (unraidDiskDescribesSMARTRow).
func hostSMARTDiskSerial(host models.Host, disk models.HostDiskSMART, unraidDisk *models.HostUnraidDisk) string {
serial := strings.TrimSpace(disk.Serial)
- if serial != "" || unraidDisk == nil || hostSMARTDevicePathShared(host, disk) {
+ if serial != "" || !unraidDiskDescribesSMARTRow(host, disk, unraidDisk) {
return serial
}
return strings.TrimSpace(unraidDisk.Serial)
}
+// unraidDiskDescribesSMARTRow reports whether the Unraid row matched to a SMART
+// row (matchUnraidDisk) describes that row's disk. An Unraid row describes a
+// kernel block device as a whole, so it describes the row when it carries the
+// row's usable serial, or when it names the row's device path and the row is
+// that whole device: not a controller member behind it, even the only one
+// reported, nor one of several rows sharing the path.
+func unraidDiskDescribesSMARTRow(host models.Host, disk models.HostDiskSMART, unraidDisk *models.HostUnraidDisk) bool {
+ if unraidDisk == nil {
+ return false
+ }
+ if serial := strings.TrimSpace(disk.Serial); diskinventory.IsUsableHardwareID(serial) &&
+ strings.EqualFold(serial, strings.TrimSpace(unraidDisk.Serial)) {
+ return true
+ }
+ device := strings.ToLower(normalizePhysicalDiskDeviceToken(disk.Device))
+ if device == "" || device != strings.ToLower(normalizePhysicalDiskDeviceToken(unraidDisk.Device)) {
+ return false
+ }
+ return !diskinventory.IsControllerMemberTarget(disk.Target) && !hostSMARTDevicePathShared(host, disk)
+}
+
// hostSMARTDevicePathShared reports whether more than one of the host's SMART
// rows, the row itself among them, names the row's device path.
func hostSMARTDevicePathShared(host models.Host, disk models.HostDiskSMART) bool {
@@ -130,6 +150,17 @@ func HostUnraidDiskSourceID(host models.Host, disk models.HostUnraidDisk) string
return ""
}
+// HostUnraidDiskMetricID returns the history key of the disk resource built
+// from a host's Unraid inventory row: the key its metrics target reads, the
+// row's usable serial or else its source ID. It returns "" for a row the
+// registry does not ingest as a disk, one without a device.
+func HostUnraidDiskMetricID(host models.Host, disk models.HostUnraidDisk) string {
+ if strings.TrimSpace(disk.Device) == "" {
+ return ""
+ }
+ return PreferredPhysicalDiskMetricID(disk.Serial, "", HostUnraidDiskSourceID(host, disk))
+}
+
const hostPhysicalDiskSourceIDMarker = "/physical-disk:"
func hostPhysicalDiskSourceID(hostID, hardwareID string) string {