chore(monitoring): record agent-lifecycle contract and disk-life proof

pulse-triage[bot]8bc6aa3c867c
diff --git a/docs/release-control/v6/internal/subsystems/agent-lifecycle.md b/docs/release-control/v6/internal/subsystems/agent-lifecycle.md
index 3be657745e..f1a834635e 100644
--- a/docs/release-control/v6/internal/subsystems/agent-lifecycle.md
+++ b/docs/release-control/v6/internal/subsystems/agent-lifecycle.md
@@ -8105,3 +8105,19 @@ install token clears the block and heals to the base identity, while a token
already bound to its own derived identity (an established distinct host sharing
a hostname or machine ID, #1753) is left untouched. Focused proof lives in
`internal/monitoring/monitor_host_agents_test.go`.
+
+### Agent endurance evidence cannot raise a disk's remaining life
+
+The physical-disk SMART merge treats a linked host agent's `PercentageUsed` as
+more precise than the Proxmox inventory, but it must not make a disk look
+healthier than Proxmox already reports. An intermittent NVMe endurance reading
+of `PercentageUsed` 0 previously raised the merged remaining life to 100, which
+resolved a genuine low-life disk-wearout alert and let it re-fire on the next
+physical-disk poll with a fresh resolved notification every poll interval
+(#2112). The merge now takes the agent value only when the Proxmox value is
+unreported or more pessimistic, never raising a reported remaining-life value,
+while still recording the agent's SMART attributes. This does not change agent
+admission, token binding or removal-block behaviour. Focused proof lives in
+`internal/monitoring/physical_disk_roundtrip_test.go`
+(`TestMergeHostAgentSMARTIntoDisks_AgentWearoutDoesNotHideLowPVELife` and
+`TestMergeHostAgentSMARTIntoDisks_AgentWearoutFillsUnreportedPVELife`).
diff --git a/docs/release-control/v6/internal/subsystems/monitoring.md b/docs/release-control/v6/internal/subsystems/monitoring.md
index 2afeefc878..5d8c706cc3 100644
--- a/docs/release-control/v6/internal/subsystems/monitoring.md
+++ b/docs/release-control/v6/internal/subsystems/monitoring.md
@@ -4116,7 +4116,7 @@ now takes the agent value when the Proxmox value is unreported (`-1`) or when
the agent value is lower (more pessimistic); it never raises a reported
remaining-life value. `PercentageUsed` and the other merged SMART attributes are
still recorded. Focused proof lives in
-`internal/monitoring/monitor_integration_test.go`
+`internal/monitoring/physical_disk_roundtrip_test.go`
(`TestMergeHostAgentSMARTIntoDisks_AgentWearoutDoesNotHideLowPVELife` and
`TestMergeHostAgentSMARTIntoDisks_AgentWearoutFillsUnreportedPVELife`). This is
synthetic merge evidence, not reporter acceptance or hardware confirmation.
diff --git a/internal/monitoring/monitor_integration_test.go b/internal/monitoring/monitor_integration_test.go
index dfd24180b5..db2dd0d5ad 100644
--- a/internal/monitoring/monitor_integration_test.go
+++ b/internal/monitoring/monitor_integration_test.go
@@ -217,73 +217,6 @@ func TestMergeHostAgentSMARTIntoDisks_SMARTFailureAndWearoutOverrideCoarsePVEVal
}
}
-func TestMergeHostAgentSMARTIntoDisks_AgentWearoutDoesNotHideLowPVELife(t *testing.T) {
- // A worn drive whose NVMe endurance log intermittently reads
- // PercentageUsed 0 must not have its Proxmox-reported remaining life
- // raised to 100. That resolved the low-life alert and let it re-fire on the
- // next poll, producing repeated notifications (#2112).
- disks := []models.PhysicalDisk{{
- ID: "d1",
- Node: "pve1",
- Serial: "SER1",
- Type: "nvme",
- Health: "PASSED",
- Wearout: 0,
- }}
- nodes := []models.Node{{Name: "pve1", LinkedAgentID: "host-1"}}
- used := 0
- hosts := []models.Host{{
- ID: "host-1",
- Sensors: models.HostSensorSummary{
- SMART: []models.HostDiskSMART{{
- Device: "/dev/nvme0n1",
- Serial: "SER1",
- Health: "PASSED",
- Attributes: &models.SMARTAttributes{
- PercentageUsed: &used,
- },
- }},
- },
- }}
-
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
- if result[0].Wearout != 0 {
- t.Fatalf("agent endurance reading raised the remaining life of a worn disk: wearout=%d", result[0].Wearout)
- }
- if result[0].SmartAttributes == nil || result[0].SmartAttributes.PercentageUsed == nil || *result[0].SmartAttributes.PercentageUsed != 0 {
- t.Fatalf("agent SMART attributes were not merged: %+v", result[0].SmartAttributes)
- }
-}
-
-func TestMergeHostAgentSMARTIntoDisks_AgentWearoutFillsUnreportedPVELife(t *testing.T) {
- disks := []models.PhysicalDisk{{
- ID: "d1",
- Node: "pve1",
- Serial: "SER1",
- Type: "nvme",
- Wearout: -1,
- }}
- nodes := []models.Node{{Name: "pve1", LinkedAgentID: "host-1"}}
- used := 40
- hosts := []models.Host{{
- ID: "host-1",
- Sensors: models.HostSensorSummary{
- SMART: []models.HostDiskSMART{{
- Device: "/dev/nvme0n1",
- Serial: "SER1",
- Attributes: &models.SMARTAttributes{
- PercentageUsed: &used,
- },
- }},
- },
- }}
-
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
- if result[0].Wearout != 60 {
- t.Fatalf("agent endurance did not fill unreported PVE life: wearout=%d", result[0].Wearout)
- }
-}
-
func TestMergeHostAgentSMARTIntoDisks_DoesNotReplaceFailureWithPassed(t *testing.T) {
disks := []models.PhysicalDisk{{ID: "d1", Node: "pve1", Serial: "SER1", Health: "FAILED"}}
nodes := []models.Node{{Name: "pve1", LinkedAgentID: "host-1"}}
diff --git a/internal/monitoring/physical_disk_roundtrip_test.go b/internal/monitoring/physical_disk_roundtrip_test.go
index 4f00d814ad..3d85327069 100644
--- a/internal/monitoring/physical_disk_roundtrip_test.go
+++ b/internal/monitoring/physical_disk_roundtrip_test.go
@@ -120,3 +120,72 @@ func TestPhysicalDiskReadbackSourceIDFallback(t *testing.T) {
t.Fatal("nil resource has a source ID")
}
}
+
+// TestMergeHostAgentSMARTIntoDisks_AgentWearoutDoesNotHideLowPVELife pins the
+// #2112 regression: a worn drive whose NVMe endurance log intermittently reads
+// PercentageUsed 0 must not have its Proxmox-reported remaining life raised to
+// 100, which resolved the low-life alert and let it re-fire on the next poll.
+func TestMergeHostAgentSMARTIntoDisks_AgentWearoutDoesNotHideLowPVELife(t *testing.T) {
+ disks := []models.PhysicalDisk{{
+ ID: "d1",
+ Node: "pve1",
+ Serial: "SER1",
+ Type: "nvme",
+ Health: "PASSED",
+ Wearout: 0,
+ }}
+ nodes := []models.Node{{Name: "pve1", LinkedAgentID: "host-1"}}
+ used := 0
+ hosts := []models.Host{{
+ ID: "host-1",
+ Sensors: models.HostSensorSummary{
+ SMART: []models.HostDiskSMART{{
+ Device: "/dev/nvme0n1",
+ Serial: "SER1",
+ Health: "PASSED",
+ Attributes: &models.SMARTAttributes{
+ PercentageUsed: &used,
+ },
+ }},
+ },
+ }}
+
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ if result[0].Wearout != 0 {
+ t.Fatalf("agent endurance reading raised the remaining life of a worn disk: wearout=%d", result[0].Wearout)
+ }
+ if result[0].SmartAttributes == nil || result[0].SmartAttributes.PercentageUsed == nil || *result[0].SmartAttributes.PercentageUsed != 0 {
+ t.Fatalf("agent SMART attributes were not merged: %+v", result[0].SmartAttributes)
+ }
+}
+
+// TestMergeHostAgentSMARTIntoDisks_AgentWearoutFillsUnreportedPVELife confirms
+// the agent still supplies endurance when the Proxmox inventory reports none.
+func TestMergeHostAgentSMARTIntoDisks_AgentWearoutFillsUnreportedPVELife(t *testing.T) {
+ disks := []models.PhysicalDisk{{
+ ID: "d1",
+ Node: "pve1",
+ Serial: "SER1",
+ Type: "nvme",
+ Wearout: -1,
+ }}
+ nodes := []models.Node{{Name: "pve1", LinkedAgentID: "host-1"}}
+ used := 40
+ hosts := []models.Host{{
+ ID: "host-1",
+ Sensors: models.HostSensorSummary{
+ SMART: []models.HostDiskSMART{{
+ Device: "/dev/nvme0n1",
+ Serial: "SER1",
+ Attributes: &models.SMARTAttributes{
+ PercentageUsed: &used,
+ },
+ }},
+ },
+ }}
+
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ if result[0].Wearout != 60 {
+ t.Fatalf("agent endurance did not fill unreported PVE life: wearout=%d", result[0].Wearout)
+ }
+}