Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Keep LXC filesystem paths native-proof
pulse-triage[bot]8fde82b8a242
diff --git a/docs/release-control/v6/internal/subsystems/agent-lifecycle.md b/docs/release-control/v6/internal/subsystems/agent-lifecycle.mdindex f654949d24..ad07738db5 100644--- a/docs/release-control/v6/internal/subsystems/agent-lifecycle.md+++ b/docs/release-control/v6/internal/subsystems/agent-lifecycle.md@@ -54,13 +54,22 @@ standby evidence. Enumeration and each device probe have independent boundeddeadlines so one slow disk cannot consume the complete SMART pass, whilecommand errors retain bounded stderr for compatibility diagnosis.On a PVE node, the Unified Agent may also report the mounted filesystem-capacity of running LXCs through the fixed local `pct list` and-`pct df <vmid>` command set. This collector is automatic when `pct` is-available, uses one shared deadline plus per-command byte ceilings, caps guest-and disk counts, never accepts an unvalidated VMID as an argument, and does not-invoke `pct df` for guests the preceding list reported stopped. The report-carries VMID and exact container name so monitoring can reject stale migration-or rename correlations.+capacity of running LXCs. The collector uses the fixed local `pct list` command+to admit only node-local running guests, reads each admitted guest's main+`/etc/pve/lxc/<vmid>.conf` mount declarations, resolves its init PID through+the fixed `lxc-info -n <vmid> -p` shape, and probes usage through the Linux+`/proc/<pid>/root` namespace. A configured path that resolves to the same+device as its parent is not a live mount and must be omitted instead of+borrowing the parent's capacity. Least-privilege installs that cannot read the+config, resolve the PID, or traverse `/proc` may fall back to the fixed+`pct df <vmid>` query for that container only. The complete pass has a bounded+collection window, every container has an independent deadline, command output+has byte ceilings, guest and disk counts are capped, unvalidated VMIDs never+become arguments, and stopped guests are never queried. Linux namespace paths+remain slash-canonical in every native build so cross-platform verification+cannot accidentally test only the fallback. The report carries VMID and exact+container name so monitoring can reject stale migration or rename+correlations.`internal/monitoring/monitor.go` also serializes shared unified-resourcewebsocket payloads. Carrying plural availability facets through that serializeris an adjacent monitoring/API projection and does not change agent enrollment,diff --git a/internal/hostagent/agent_metrics_test.go b/internal/hostagent/agent_metrics_test.goindex f63984a8d2..dd895994e3 100644--- a/internal/hostagent/agent_metrics_test.go+++ b/internal/hostagent/agent_metrics_test.go@@ -58,6 +58,12 @@ func TestAgentMetricsSMARTProbeAttemptsRetryExplicitSAT(t *testing.T) {}}+func TestProxmoxLXCConfigPathRemainsLinuxNative(t *testing.T) {+ if got, want := proxmoxLXCConfigPath(100), "/etc/pve/lxc/100.conf"; got != want {+ t.Fatalf("proxmoxLXCConfigPath(100) = %q, want %q", got, want)+ }+}+func TestBuildReport(t *testing.T) {// Setup mocksfixedTime := time.Date(2025, 1, 1, 12, 0, 0, 0, time.UTC)diff --git a/internal/hostagent/proxmox_lxc_filesystems.go b/internal/hostagent/proxmox_lxc_filesystems.goindex bf2b6bcad7..aa3f194881 100644--- a/internal/hostagent/proxmox_lxc_filesystems.go+++ b/internal/hostagent/proxmox_lxc_filesystems.go@@ -219,7 +219,7 @@ func (a *Agent) collectProxmoxLXCContainerDisksFast(lxcInfoPath string,vmid int,) ([]agentshost.Disk, error) {- raw, err := a.collector.ReadFile(filepath.Join(proxmoxLXCConfigDir, strconv.Itoa(vmid)+".conf"))+ raw, err := a.collector.ReadFile(proxmoxLXCConfigPath(vmid))if err != nil {return nil, fmt.Errorf("read container config: %w", err)}@@ -315,6 +315,13 @@ func (a *Agent) collectProxmoxLXCContainerDisksFast(return result, nil}+func proxmoxLXCConfigPath(vmid int) string {+ // The collector reads the Linux Proxmox namespace even when native tests+ // exercise this path from another GOOS. filepath.Join would turn this into+ // a Windows path and silently force the slower pct fallback.+ return path.Join(proxmoxLXCConfigDir, strconv.Itoa(vmid)+".conf")+}+// parseProxmoxLXCConfigMounts extracts rootfs and mpN entries from the main// section of a container config. Parsing stops at the first section header so// snapshot and pending sections can never contribute mounts.