Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Normalize typed SMART device labels for temperature merge
rcourtman97c6cad01cd8
diff --git a/internal/monitoring/merge_temps_test.go b/internal/monitoring/merge_temps_test.goindex 2b5d9a6895..4b6f5f5bae 100644--- a/internal/monitoring/merge_temps_test.go+++ b/internal/monitoring/merge_temps_test.go@@ -331,3 +331,22 @@ func TestMergeNVMeTempsIntoDisks_OriginalSliceUnchanged(t *testing.T) {t.Errorf("original disk temperature was modified: got %d, want 0", original[0].Temperature)}}++func TestNormalizeSMARTDeviceIdentifier(t *testing.T) {+ cases := []struct {+ in string+ want string+ }{+ {"sdd [scsi]", "sdd"},+ {"/dev/sdd [scsi]", "sdd"},+ {"/dev/nvme0n1", "nvme0n1"},+ {"sda", "sda"},+ {" sdb [ata] ", "sdb"},+ {"", ""},+ }+ for _, tc := range cases {+ if got := normalizeSMARTDeviceIdentifier(tc.in); got != tc.want {+ t.Errorf("normalizeSMARTDeviceIdentifier(%q) = %q, want %q", tc.in, got, tc.want)+ }+ }+}diff --git a/internal/monitoring/monitor.go b/internal/monitoring/monitor.goindex 00d1929c8a..2cf6c0f105 100644--- a/internal/monitoring/monitor.go+++ b/internal/monitoring/monitor.go@@ -274,6 +274,23 @@ func (m *Monitor) getPMGClient(name string) (*pmg.Client, bool) {return client, ok}+// normalizeSMARTDeviceIdentifier strips a trailing type annotation (e.g.+// "sdd [scsi]" -> "sdd") and the /dev/ prefix so SMART temperatures match disks+// by device path even when smartctl reports a typed label.+func normalizeSMARTDeviceIdentifier(device string) string {+ normalized := strings.TrimSpace(device)+ if normalized == "" {+ return ""+ }++ if base, suffix, found := strings.Cut(normalized, " ["); found && strings.HasSuffix(suffix, "]") {+ normalized = base+ }++ normalized = strings.TrimSpace(normalized)+ return strings.TrimPrefix(normalized, "/dev/")+}+func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) []models.PhysicalDisk {if len(disks) == 0 || len(nodes) == 0 {return disks@@ -387,10 +404,10 @@ func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) [// Last resort: match by device path (normalized)if updated[i].Temperature == 0 {- normalizedDevPath := strings.TrimPrefix(updated[i].DevPath, "/dev/")+ normalizedDevPath := normalizeSMARTDeviceIdentifier(updated[i].DevPath)for _, temp := range smartTemps {- normalizedTempDev := strings.TrimPrefix(temp.Device, "/dev/")- if normalizedTempDev == normalizedDevPath {+ normalizedTempDev := normalizeSMARTDeviceIdentifier(temp.Device)+ if normalizedTempDev != "" && normalizedTempDev == normalizedDevPath {if temp.Temperature > 0 && !temp.StandbySkipped {updated[i].Temperature = temp.Temperaturelog.Debug().@@ -513,10 +530,10 @@ func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.No// Last resort: match by device pathif matched == nil {- normalizedDevPath := strings.TrimPrefix(updated[i].DevPath, "/dev/")+ normalizedDevPath := normalizeSMARTDeviceIdentifier(updated[i].DevPath)for j := range smartData {- normalizedDiskDev := strings.TrimPrefix(smartData[j].Device, "/dev/")- if normalizedDiskDev == normalizedDevPath {+ normalizedDiskDev := normalizeSMARTDeviceIdentifier(smartData[j].Device)+ if normalizedDiskDev != "" && normalizedDiskDev == normalizedDevPath {matched = &smartData[j]break}