Parse smartctl 7.5 power_mode object on guarded probes

rcourtmana39935182de6
diff --git a/internal/hostagent/issue1690_smartctl75_power_mode_test.go b/internal/hostagent/issue1690_smartctl75_power_mode_test.go
new file mode 100644
index 0000000000..cb6204a11b
--- /dev/null
+++ b/internal/hostagent/issue1690_smartctl75_power_mode_test.go
@@ -0,0 +1,111 @@
+package hostagent
+
+// Discussion #1690: smartmontools 7.5 started emitting power_mode as a JSON
+// object whenever the -n power guard runs, which is every rotational-disk
+// probe. The parser declared the field as a string, so json.Unmarshal failed
+// for the entire document and healthy spinning disks behind a SAS HBA were
+// reported as having no usable SMART data while guard-free SSD probes kept
+// working. These tests pin the smartctl 7.5 shapes end to end.
+
+import (
+ "errors"
+ "testing"
+)
+
+func TestIssue1690PowerModeObjectActiveDiskParsesFully(t *testing.T) {
+ result, err := parseSMARTOutput([]byte(`{
+ "device":{"name":"/dev/sda","type":"sat","protocol":"ATA"},
+ "model_name":"Hitachi HUA722020ALA330",
+ "serial_number":"JK11A1YAJNX41V",
+ "power_mode":{"ata_value":255,"name":"ACTIVE or IDLE"},
+ "smart_status":{"passed":true},
+ "temperature":{"current":60},
+ "ata_smart_attributes":{"table":[
+ {"id":194,"raw":{"value":60,"string":"60 (Min/Max 22/68)"}}
+ ]}
+ }`), smartctlTarget{Path: "/dev/sda", DeviceType: "sat"})
+ if err != nil {
+ t.Fatalf("parse smartctl 7.5 output with power_mode object: %v", err)
+ }
+ if result.Health != "PASSED" || result.Temperature != 60 {
+ t.Fatalf("active disk lost SMART data behind power_mode object: %+v", result)
+ }
+ if result.Standby {
+ t.Fatalf("ACTIVE or IDLE misread as standby: %+v", result)
+ }
+ if result.Serial != "JK11A1YAJNX41V" {
+ t.Fatalf("serial lost behind power_mode object: %+v", result)
+ }
+}
+
+func TestIssue1690PowerModeObjectStandbyAbortReportsStandby(t *testing.T) {
+ for _, name := range []string{"STANDBY", "STANDBY_Y", "SLEEP"} {
+ result, err := parseSMARTOutput([]byte(`{
+ "device":{"name":"/dev/sda","type":"sat","protocol":"ATA"},
+ "power_mode":{"ata_value":0,"name":"`+name+`"}
+ }`), smartctlTarget{Path: "/dev/sda", DeviceType: "sat"})
+ if err != nil {
+ t.Fatalf("power_mode %s: aborted probe dropped instead of standby: %v", name, err)
+ }
+ if !result.Standby {
+ t.Fatalf("power_mode %s not reported as standby: %+v", name, result)
+ }
+ }
+}
+
+func TestIssue1690PowerModeLegacyStringStillAccepted(t *testing.T) {
+ result, err := parseSMARTOutput([]byte(`{
+ "device":{"name":"/dev/sda","type":"sat","protocol":"ATA"},
+ "power_mode":"STANDBY"
+ }`), smartctlTarget{Path: "/dev/sda", DeviceType: "sat"})
+ if err != nil {
+ t.Fatalf("legacy string power_mode rejected: %v", err)
+ }
+ if !result.Standby {
+ t.Fatalf("legacy string power_mode not reported as standby: %+v", result)
+ }
+}
+
+func TestIssue1690PowerModeUnknownShapeCostsOnlyTheField(t *testing.T) {
+ result, err := parseSMARTOutput([]byte(`{
+ "device":{"name":"/dev/sda","type":"sat","protocol":"ATA"},
+ "model_name":"Hitachi HUA722020ALA330",
+ "serial_number":"JK11A1YAJNX41V",
+ "power_mode":42,
+ "smart_status":{"passed":true},
+ "temperature":{"current":60}
+ }`), smartctlTarget{Path: "/dev/sda", DeviceType: "sat"})
+ if err != nil {
+ t.Fatalf("numeric power_mode failed the whole document: %v", err)
+ }
+ if result.Health != "PASSED" || result.Temperature != 60 || result.Standby {
+ t.Fatalf("unknown power_mode shape corrupted the result: %+v", result)
+ }
+}
+
+func TestIssue1690TextFallbackCatchesEPCStandbyVariants(t *testing.T) {
+ for _, line := range []string{
+ "Device is in STANDBY mode, exit(3)",
+ "Device is in STANDBY_Y mode, exit(3)",
+ "Device is in STANDBY (OS) mode, exit(3)",
+ "Device is in SLEEP mode, exit(3)",
+ } {
+ fallback := parseSMARTTextFallback(line)
+ if !fallback.Standby {
+ t.Fatalf("text fallback missed standby line %q", line)
+ }
+ }
+
+ if parseSMARTTextFallback("SMART overall-health self-assessment test result: PASSED").Standby {
+ t.Fatal("text fallback fabricated standby from a healthy line")
+ }
+}
+
+func TestIssue1690EmptyDocumentStillUnavailable(t *testing.T) {
+ _, err := parseSMARTOutput([]byte(`{
+ "device":{"name":"/dev/sda","type":"sat","protocol":"ATA"}
+ }`), smartctlTarget{Path: "/dev/sda", DeviceType: "sat"})
+ if !errors.Is(err, errSMARTDataUnavailable) {
+ t.Fatalf("document with no SMART evidence must stay unavailable, got %v", err)
+ }
+}
diff --git a/internal/hostagent/smartctl.go b/internal/hostagent/smartctl.go
index 30f2a813b3..80db514ab7 100644
--- a/internal/hostagent/smartctl.go
+++ b/internal/hostagent/smartctl.go
@@ -206,7 +206,38 @@ type smartctlJSON struct {
} `json:"current"`
} `json:"ata_sct_status"`
NVMeSmartHealthInformationLog *nvmeSmartHealthInformationLogJSON `json:"nvme_smart_health_information_log"`
- PowerMode string `json:"power_mode"`
+ PowerMode smartctlPowerModeJSON `json:"power_mode"`
+}
+
+// smartctlPowerModeJSON absorbs every shape smartctl has used for the JSON
+// power_mode field. smartmontools 7.5 introduced it as an object,
+// {"ata_value": 255, "name": "ACTIVE or IDLE"}, emitted whenever the -n
+// guard runs CHECK POWER MODE — which is every rotational-disk probe here.
+// Decoding it into a plain string failed json.Unmarshal for the whole
+// document, so healthy output from spinning disks degraded to the lossy text
+// fallback and was dropped as "no usable SMART data" (discussion #1690). The
+// decoder never propagates an error: an unrecognized future shape must cost
+// only this field, never the document.
+type smartctlPowerModeJSON struct {
+ Name string `json:"name"`
+ ATAValue int `json:"ata_value"`
+}
+
+func (p *smartctlPowerModeJSON) UnmarshalJSON(data []byte) error {
+ var object struct {
+ Name string `json:"name"`
+ ATAValue int `json:"ata_value"`
+ }
+ if err := json.Unmarshal(data, &object); err == nil {
+ p.Name = object.Name
+ p.ATAValue = object.ATAValue
+ return nil
+ }
+ var name string
+ if err := json.Unmarshal(data, &name); err == nil {
+ p.Name = name
+ }
+ return nil
}
type smartTextFallback struct {
@@ -1862,7 +1893,7 @@ func parseSMARTOutput(output []byte, target smartctlTarget) (*DiskSMART, error)
Model: smartData.ModelName,
Serial: smartData.SerialNumber,
Type: detectDiskType(smartData),
- Standby: isStandbyPowerMode(smartData.PowerMode),
+ Standby: isStandbyPowerMode(smartData.PowerMode.Name),
LastUpdated: timeNow(),
Collection: &diskinventory.CollectionStatus{},
}
@@ -2044,8 +2075,12 @@ func parseSMARTTextFallback(text string) smartTextFallback {
}
case strings.HasPrefix(lower, "serial number:"):
fallback.Serial = strings.TrimSpace(line[len("Serial Number:"):])
- case strings.Contains(lower, "device is in standby mode"),
+ case strings.Contains(lower, "device is in standby"),
+ strings.Contains(lower, "device is in sleep"),
strings.Contains(lower, "standby (os)"):
+ // "device is in standby" deliberately drops the " mode" suffix:
+ // smartctl names EPC states STANDBY_Y / STANDBY (OS), and the
+ // suffixed match silently missed both (discussion #1690).
fallback.Standby = true
case strings.HasPrefix(lower, "smart overall-health self-assessment test result:"):
fallback.Health = parseSMARTHealthText(line)
diff --git a/internal/hostagent/smartctl_test.go b/internal/hostagent/smartctl_test.go
index 2c4380d478..5705f813f2 100644
--- a/internal/hostagent/smartctl_test.go
+++ b/internal/hostagent/smartctl_test.go
@@ -423,7 +423,7 @@ func TestParseSMARTOutputStandbyPowerMode(t *testing.T) {
payload := smartctlJSON{
ModelName: "WDC WD40EFRX",
SerialNumber: "WD-123",
- PowerMode: "STANDBY",
+ PowerMode: smartctlPowerModeJSON{Name: "STANDBY"},
}
payload.Device.Protocol = "ATA"