Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Skip false health alerts for Samsung 980/990 SSDs and improve Docker CPU calculation
rcourtmanb44084af3c3d
diff --git a/internal/alerts/alerts.go b/internal/alerts/alerts.goindex 139539396d..ea5371ebff 100644--- a/internal/alerts/alerts.go+++ b/internal/alerts/alerts.go@@ -7902,6 +7902,34 @@ func (m *Manager) periodicSaveAlerts() {}}+// hasKnownFirmwareBug checks if a disk model is known to have firmware bugs that cause+// false health status reports. These drives may report FAILED or other error states+// due to firmware issues (e.g., incorrect temperature thresholds) even when the drive+// is actually healthy. This prevents false alerts while still monitoring wearout.+//+// Related to GitHub issue #547: Samsung 980/990 SSDs report false health failures+func hasKnownFirmwareBug(model string) bool {+ normalizedModel := strings.ToUpper(strings.TrimSpace(model))++ // Samsung 980/990 series drives have known firmware bugs causing false health reports+ // These drives report incorrect health status due to temperature threshold bugs+ // even when functioning normally. Users should update firmware to latest version.+ knownProblematicModels := []string{+ "SAMSUNG SSD 980",+ "SAMSUNG 980",+ "SAMSUNG SSD 990",+ "SAMSUNG 990",+ }++ for _, problematic := range knownProblematicModels {+ if strings.Contains(normalizedModel, problematic) {+ return true+ }+ }++ return false+}+// CheckDiskHealth checks disk health and creates alerts if neededfunc (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {// Create unique alert ID for this disk@@ -7913,6 +7941,23 @@ func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {// Check if disk health is not PASSEDnormalizedHealth := strings.ToUpper(strings.TrimSpace(disk.Health))if normalizedHealth != "" && normalizedHealth != "UNKNOWN" && normalizedHealth != "PASSED" && normalizedHealth != "OK" {+ // Skip health alerts for drives with known firmware bugs that cause false reports+ // These drives may report FAILED status due to firmware issues even when healthy+ // We still monitor wearout below, which is more reliable for these drives+ if hasKnownFirmwareBug(disk.Model) {+ log.Debug().+ Str("node", node).+ Str("disk", disk.DevPath).+ Str("model", disk.Model).+ Str("health", disk.Health).+ Msg("Skipping health alert for drive with known firmware bug - health status unreliable")++ // Clear any existing health alert since we now recognize this is a false positive+ m.clearAlertNoLock(alertID)++ // Continue to wearout check below - wearout monitoring is still valid+ goto checkWearout+ }// Check if alert already existsif _, exists := m.activeAlerts[alertID]; !exists {// Create new health alert@@ -7959,6 +8004,7 @@ func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {m.clearAlertNoLock(alertID)}+checkWearout:// Check for low wearout (SSD life remaining)if disk.Wearout > 0 && disk.Wearout < 10 {wearoutAlertID := fmt.Sprintf("disk-wearout-%s-%s-%s", instance, node, disk.DevPath)diff --git a/internal/alerts/alerts_test.go b/internal/alerts/alerts_test.goindex 0d30fce6ac..db5394a49d 100644--- a/internal/alerts/alerts_test.go+++ b/internal/alerts/alerts_test.go@@ -9,6 +9,7 @@ import ("time""github.com/rcourtman/pulse-go-rewrite/internal/models"+ "github.com/rcourtman/pulse-go-rewrite/pkg/proxmox")func TestAcknowledgePersistsThroughCheckMetric(t *testing.T) {@@ -1543,3 +1544,114 @@ func TestDockerResourceID(t *testing.T) {})}}++func TestHasKnownFirmwareBug(t *testing.T) {+ t.Parallel()++ tests := []struct {+ name string+ model string+ want bool+ }{+ {name: "Samsung 980 with SSD prefix", model: "Samsung SSD 980 1TB", want: true},+ {name: "Samsung 980 without SSD prefix", model: "Samsung 980 PRO 2TB", want: true},+ {name: "Samsung 990 with SSD prefix", model: "Samsung SSD 990 PRO 2TB", want: true},+ {name: "Samsung 990 without SSD prefix", model: "Samsung 990 EVO 1TB", want: true},+ {name: "Samsung 980 lowercase", model: "samsung ssd 980 1tb", want: true},+ {name: "Samsung 990 mixed case", model: "SAMSUNG 990 PRO", want: true},+ {name: "Samsung 970 (not affected)", model: "Samsung SSD 970 EVO Plus", want: false},+ {name: "Samsung 870 (not affected)", model: "Samsung 870 QVO", want: false},+ {name: "Other manufacturer", model: "WD Blue SN570", want: false},+ {name: "Empty model", model: "", want: false},+ }++ for _, tc := range tests {+ tc := tc+ t.Run(tc.name, func(t *testing.T) {+ t.Parallel()++ if got := hasKnownFirmwareBug(tc.model); got != tc.want {+ t.Fatalf("hasKnownFirmwareBug(%q) = %v, want %v", tc.model, got, tc.want)+ }+ })+ }+}++func TestCheckDiskHealthSkipsSamsung980FalseAlerts(t *testing.T) {+ m := NewManager()+ m.ClearActiveAlerts()++ // Samsung 980 reporting FAILED health (firmware bug) but actually healthy+ disk := proxmox.Disk{+ DevPath: "/dev/nvme0n1",+ Model: "Samsung SSD 980 1TB",+ Serial: "S649NF0R123456",+ Type: "nvme",+ Health: "FAILED", // False report due to firmware bug+ Wearout: 99, // Drive is actually healthy with 99% life remaining+ Size: 1000204886016,+ }++ // Should not create an alert for health status+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ healthAlertID := "disk-health-test-instance-pve-node1-/dev/nvme0n1"+ if _, exists := m.activeAlerts[healthAlertID]; exists {+ m.mu.RUnlock()+ t.Fatalf("expected no health alert for Samsung 980 with known firmware bug")+ }+ m.mu.RUnlock()++ // Now test that wearout alerts still work for these drives+ disk.Wearout = 5 // Low wearout should still trigger alert+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ wearoutAlertID := "disk-wearout-test-instance-pve-node1-/dev/nvme0n1"+ if _, exists := m.activeAlerts[wearoutAlertID]; !exists {+ m.mu.RUnlock()+ t.Fatalf("expected wearout alert to still work for Samsung 980")+ }+ m.mu.RUnlock()+}++func TestCheckDiskHealthClearsExistingSamsung980Alerts(t *testing.T) {+ m := NewManager()+ m.ClearActiveAlerts()++ disk := proxmox.Disk{+ DevPath: "/dev/nvme0n1",+ Model: "Samsung SSD 990 PRO 2TB",+ Serial: "S6Z0NF0R654321",+ Type: "nvme",+ Health: "FAILED",+ Wearout: 98,+ Size: 2000398934016,+ }++ alertID := "disk-health-test-instance-pve-node1-/dev/nvme0n1"++ // Manually create an existing alert (simulating alert from before the fix)+ m.mu.Lock()+ m.activeAlerts[alertID] = &Alert{+ ID: alertID,+ Type: "disk-health",+ Level: AlertLevelCritical,+ ResourceID: "pve-node1-/dev/nvme0n1",+ ResourceName: "Samsung SSD 990 PRO 2TB (/dev/nvme0n1)",+ Node: "pve-node1",+ Instance: "test-instance",+ Message: "Disk health check failed: FAILED",+ }+ m.mu.Unlock()++ // Check disk health - should clear the existing false alert+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ defer m.mu.RUnlock()+ if _, exists := m.activeAlerts[alertID]; exists {+ t.Fatalf("expected existing Samsung 990 health alert to be cleared")+ }+}diff --git a/internal/dockeragent/agent.go b/internal/dockeragent/agent.goindex 38a152c926..1048619bbe 100644--- a/internal/dockeragent/agent.go+++ b/internal/dockeragent/agent.go@@ -95,8 +95,9 @@ type Agent struct {targets []TargetConfigallowedStates map[string]struct{}stateFilters []string- hostID string- prevContainerCPU map[string]cpuSample+ hostID string+ prevContainerCPU map[string]cpuSample+ preCPUStatsFailures int}// ErrStopRequested indicates the agent should terminate gracefully after acknowledging a stop command.@@ -1291,18 +1292,40 @@ func (a *Agent) calculateContainerCPUPercent(id string, stats containertypes.Staread: stats.Read,}+ // Try to use PreCPUStats if availablepercent := calculateCPUPercent(stats, a.cpuCount)if percent > 0 {a.prevContainerCPU[id] = current+ a.logger.Debug().+ Str("container_id", id[:12]).+ Float64("cpu_percent", percent).+ Msg("CPU calculated from PreCPUStats")return percent}+ // PreCPUStats not available or invalid, use manual tracking+ a.preCPUStatsFailures+++ if a.preCPUStatsFailures == 10 {+ a.logger.Warn().+ Str("runtime", string(a.runtime)).+ Msg("PreCPUStats consistently unavailable from Docker API - using manual CPU tracking (this is normal for one-shot stats)")+ }prev, ok := a.prevContainerCPU[id]- a.prevContainerCPU[id] = currentif !ok {+ // First time seeing this container - store current sample and return 0+ // On next collection cycle we'll have a previous sample to compare against+ a.prevContainerCPU[id] = current+ a.logger.Debug().+ Str("container_id", id[:12]).+ Uint64("total_usage", current.totalUsage).+ Uint64("system_usage", current.systemUsage).+ Msg("First CPU sample collected, no previous data for delta calculation")return 0}+ // We have a previous sample - update it after calculation+ a.prevContainerCPU[id] = current+var totalDelta float64if current.totalUsage >= prev.totalUsage {totalDelta = float64(current.totalUsage - prev.totalUsage)@@ -1334,20 +1357,44 @@ func (a *Agent) calculateContainerCPUPercent(id string, stats containertypes.Sta}if systemDelta > 0 {- return safeFloat((totalDelta / systemDelta) * float64(onlineCPUs) * 100.0)+ cpuPercent := safeFloat((totalDelta / systemDelta) * float64(onlineCPUs) * 100.0)+ a.logger.Debug().+ Str("container_id", id[:12]).+ Float64("cpu_percent", cpuPercent).+ Float64("total_delta", totalDelta).+ Float64("system_delta", systemDelta).+ Uint32("online_cpus", onlineCPUs).+ Msg("CPU calculated from system delta")+ return cpuPercent}+ // Fall back to time-based calculationif !prev.read.IsZero() && !current.read.IsZero() {elapsed := current.read.Sub(prev.read).Seconds()if elapsed > 0 {denominator := elapsed * float64(onlineCPUs) * 1e9if denominator > 0 {cpuPercent := (totalDelta / denominator) * 100.0- return safeFloat(cpuPercent)+ result := safeFloat(cpuPercent)+ a.logger.Debug().+ Str("container_id", id[:12]).+ Float64("cpu_percent", result).+ Float64("total_delta", totalDelta).+ Float64("elapsed_seconds", elapsed).+ Uint32("online_cpus", onlineCPUs).+ Msg("CPU calculated from time-based delta")+ return result}}}+ a.logger.Debug().+ Str("container_id", id[:12]).+ Float64("total_delta", totalDelta).+ Float64("system_delta", systemDelta).+ Bool("prev_read_zero", prev.read.IsZero()).+ Bool("current_read_zero", current.read.IsZero()).+ Msg("CPU calculation failed: no valid delta method available")return 0}