Skip to content

armgit / Pulse

Public Imported from GitHub
0

Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.

Skip false health alerts for Samsung 980/990 SSDs and improve Docker CPU calculation

rcourtmanb44084af3c3d
diff --git a/internal/alerts/alerts.go b/internal/alerts/alerts.go
index 139539396d..ea5371ebff 100644
--- a/internal/alerts/alerts.go
+++ b/internal/alerts/alerts.go
@@ -7902,6 +7902,34 @@ func (m *Manager) periodicSaveAlerts() {
}
}
+// hasKnownFirmwareBug checks if a disk model is known to have firmware bugs that cause
+// false health status reports. These drives may report FAILED or other error states
+// due to firmware issues (e.g., incorrect temperature thresholds) even when the drive
+// is actually healthy. This prevents false alerts while still monitoring wearout.
+//
+// Related to GitHub issue #547: Samsung 980/990 SSDs report false health failures
+func hasKnownFirmwareBug(model string) bool {
+ normalizedModel := strings.ToUpper(strings.TrimSpace(model))
+
+ // Samsung 980/990 series drives have known firmware bugs causing false health reports
+ // These drives report incorrect health status due to temperature threshold bugs
+ // even when functioning normally. Users should update firmware to latest version.
+ knownProblematicModels := []string{
+ "SAMSUNG SSD 980",
+ "SAMSUNG 980",
+ "SAMSUNG SSD 990",
+ "SAMSUNG 990",
+ }
+
+ for _, problematic := range knownProblematicModels {
+ if strings.Contains(normalizedModel, problematic) {
+ return true
+ }
+ }
+
+ return false
+}
+
// CheckDiskHealth checks disk health and creates alerts if needed
func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {
// Create unique alert ID for this disk
@@ -7913,6 +7941,23 @@ func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {
// Check if disk health is not PASSED
normalizedHealth := strings.ToUpper(strings.TrimSpace(disk.Health))
if normalizedHealth != "" && normalizedHealth != "UNKNOWN" && normalizedHealth != "PASSED" && normalizedHealth != "OK" {
+ // Skip health alerts for drives with known firmware bugs that cause false reports
+ // These drives may report FAILED status due to firmware issues even when healthy
+ // We still monitor wearout below, which is more reliable for these drives
+ if hasKnownFirmwareBug(disk.Model) {
+ log.Debug().
+ Str("node", node).
+ Str("disk", disk.DevPath).
+ Str("model", disk.Model).
+ Str("health", disk.Health).
+ Msg("Skipping health alert for drive with known firmware bug - health status unreliable")
+
+ // Clear any existing health alert since we now recognize this is a false positive
+ m.clearAlertNoLock(alertID)
+
+ // Continue to wearout check below - wearout monitoring is still valid
+ goto checkWearout
+ }
// Check if alert already exists
if _, exists := m.activeAlerts[alertID]; !exists {
// Create new health alert
@@ -7959,6 +8004,7 @@ func (m *Manager) CheckDiskHealth(instance, node string, disk proxmox.Disk) {
m.clearAlertNoLock(alertID)
}
+checkWearout:
// Check for low wearout (SSD life remaining)
if disk.Wearout > 0 && disk.Wearout < 10 {
wearoutAlertID := fmt.Sprintf("disk-wearout-%s-%s-%s", instance, node, disk.DevPath)
diff --git a/internal/alerts/alerts_test.go b/internal/alerts/alerts_test.go
index 0d30fce6ac..db5394a49d 100644
--- a/internal/alerts/alerts_test.go
+++ b/internal/alerts/alerts_test.go
@@ -9,6 +9,7 @@ import (
"time"
"github.com/rcourtman/pulse-go-rewrite/internal/models"
+ "github.com/rcourtman/pulse-go-rewrite/pkg/proxmox"
)
func TestAcknowledgePersistsThroughCheckMetric(t *testing.T) {
@@ -1543,3 +1544,114 @@ func TestDockerResourceID(t *testing.T) {
})
}
}
+
+func TestHasKnownFirmwareBug(t *testing.T) {
+ t.Parallel()
+
+ tests := []struct {
+ name string
+ model string
+ want bool
+ }{
+ {name: "Samsung 980 with SSD prefix", model: "Samsung SSD 980 1TB", want: true},
+ {name: "Samsung 980 without SSD prefix", model: "Samsung 980 PRO 2TB", want: true},
+ {name: "Samsung 990 with SSD prefix", model: "Samsung SSD 990 PRO 2TB", want: true},
+ {name: "Samsung 990 without SSD prefix", model: "Samsung 990 EVO 1TB", want: true},
+ {name: "Samsung 980 lowercase", model: "samsung ssd 980 1tb", want: true},
+ {name: "Samsung 990 mixed case", model: "SAMSUNG 990 PRO", want: true},
+ {name: "Samsung 970 (not affected)", model: "Samsung SSD 970 EVO Plus", want: false},
+ {name: "Samsung 870 (not affected)", model: "Samsung 870 QVO", want: false},
+ {name: "Other manufacturer", model: "WD Blue SN570", want: false},
+ {name: "Empty model", model: "", want: false},
+ }
+
+ for _, tc := range tests {
+ tc := tc
+ t.Run(tc.name, func(t *testing.T) {
+ t.Parallel()
+
+ if got := hasKnownFirmwareBug(tc.model); got != tc.want {
+ t.Fatalf("hasKnownFirmwareBug(%q) = %v, want %v", tc.model, got, tc.want)
+ }
+ })
+ }
+}
+
+func TestCheckDiskHealthSkipsSamsung980FalseAlerts(t *testing.T) {
+ m := NewManager()
+ m.ClearActiveAlerts()
+
+ // Samsung 980 reporting FAILED health (firmware bug) but actually healthy
+ disk := proxmox.Disk{
+ DevPath: "/dev/nvme0n1",
+ Model: "Samsung SSD 980 1TB",
+ Serial: "S649NF0R123456",
+ Type: "nvme",
+ Health: "FAILED", // False report due to firmware bug
+ Wearout: 99, // Drive is actually healthy with 99% life remaining
+ Size: 1000204886016,
+ }
+
+ // Should not create an alert for health status
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ healthAlertID := "disk-health-test-instance-pve-node1-/dev/nvme0n1"
+ if _, exists := m.activeAlerts[healthAlertID]; exists {
+ m.mu.RUnlock()
+ t.Fatalf("expected no health alert for Samsung 980 with known firmware bug")
+ }
+ m.mu.RUnlock()
+
+ // Now test that wearout alerts still work for these drives
+ disk.Wearout = 5 // Low wearout should still trigger alert
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ wearoutAlertID := "disk-wearout-test-instance-pve-node1-/dev/nvme0n1"
+ if _, exists := m.activeAlerts[wearoutAlertID]; !exists {
+ m.mu.RUnlock()
+ t.Fatalf("expected wearout alert to still work for Samsung 980")
+ }
+ m.mu.RUnlock()
+}
+
+func TestCheckDiskHealthClearsExistingSamsung980Alerts(t *testing.T) {
+ m := NewManager()
+ m.ClearActiveAlerts()
+
+ disk := proxmox.Disk{
+ DevPath: "/dev/nvme0n1",
+ Model: "Samsung SSD 990 PRO 2TB",
+ Serial: "S6Z0NF0R654321",
+ Type: "nvme",
+ Health: "FAILED",
+ Wearout: 98,
+ Size: 2000398934016,
+ }
+
+ alertID := "disk-health-test-instance-pve-node1-/dev/nvme0n1"
+
+ // Manually create an existing alert (simulating alert from before the fix)
+ m.mu.Lock()
+ m.activeAlerts[alertID] = &Alert{
+ ID: alertID,
+ Type: "disk-health",
+ Level: AlertLevelCritical,
+ ResourceID: "pve-node1-/dev/nvme0n1",
+ ResourceName: "Samsung SSD 990 PRO 2TB (/dev/nvme0n1)",
+ Node: "pve-node1",
+ Instance: "test-instance",
+ Message: "Disk health check failed: FAILED",
+ }
+ m.mu.Unlock()
+
+ // Check disk health - should clear the existing false alert
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ defer m.mu.RUnlock()
+ if _, exists := m.activeAlerts[alertID]; exists {
+ t.Fatalf("expected existing Samsung 990 health alert to be cleared")
+ }
+}
diff --git a/internal/dockeragent/agent.go b/internal/dockeragent/agent.go
index 38a152c926..1048619bbe 100644
--- a/internal/dockeragent/agent.go
+++ b/internal/dockeragent/agent.go
@@ -95,8 +95,9 @@ type Agent struct {
targets []TargetConfig
allowedStates map[string]struct{}
stateFilters []string
- hostID string
- prevContainerCPU map[string]cpuSample
+ hostID string
+ prevContainerCPU map[string]cpuSample
+ preCPUStatsFailures int
}
// ErrStopRequested indicates the agent should terminate gracefully after acknowledging a stop command.
@@ -1291,18 +1292,40 @@ func (a *Agent) calculateContainerCPUPercent(id string, stats containertypes.Sta
read: stats.Read,
}
+ // Try to use PreCPUStats if available
percent := calculateCPUPercent(stats, a.cpuCount)
if percent > 0 {
a.prevContainerCPU[id] = current
+ a.logger.Debug().
+ Str("container_id", id[:12]).
+ Float64("cpu_percent", percent).
+ Msg("CPU calculated from PreCPUStats")
return percent
}
+ // PreCPUStats not available or invalid, use manual tracking
+ a.preCPUStatsFailures++
+ if a.preCPUStatsFailures == 10 {
+ a.logger.Warn().
+ Str("runtime", string(a.runtime)).
+ Msg("PreCPUStats consistently unavailable from Docker API - using manual CPU tracking (this is normal for one-shot stats)")
+ }
prev, ok := a.prevContainerCPU[id]
- a.prevContainerCPU[id] = current
if !ok {
+ // First time seeing this container - store current sample and return 0
+ // On next collection cycle we'll have a previous sample to compare against
+ a.prevContainerCPU[id] = current
+ a.logger.Debug().
+ Str("container_id", id[:12]).
+ Uint64("total_usage", current.totalUsage).
+ Uint64("system_usage", current.systemUsage).
+ Msg("First CPU sample collected, no previous data for delta calculation")
return 0
}
+ // We have a previous sample - update it after calculation
+ a.prevContainerCPU[id] = current
+
var totalDelta float64
if current.totalUsage >= prev.totalUsage {
totalDelta = float64(current.totalUsage - prev.totalUsage)
@@ -1334,20 +1357,44 @@ func (a *Agent) calculateContainerCPUPercent(id string, stats containertypes.Sta
}
if systemDelta > 0 {
- return safeFloat((totalDelta / systemDelta) * float64(onlineCPUs) * 100.0)
+ cpuPercent := safeFloat((totalDelta / systemDelta) * float64(onlineCPUs) * 100.0)
+ a.logger.Debug().
+ Str("container_id", id[:12]).
+ Float64("cpu_percent", cpuPercent).
+ Float64("total_delta", totalDelta).
+ Float64("system_delta", systemDelta).
+ Uint32("online_cpus", onlineCPUs).
+ Msg("CPU calculated from system delta")
+ return cpuPercent
}
+ // Fall back to time-based calculation
if !prev.read.IsZero() && !current.read.IsZero() {
elapsed := current.read.Sub(prev.read).Seconds()
if elapsed > 0 {
denominator := elapsed * float64(onlineCPUs) * 1e9
if denominator > 0 {
cpuPercent := (totalDelta / denominator) * 100.0
- return safeFloat(cpuPercent)
+ result := safeFloat(cpuPercent)
+ a.logger.Debug().
+ Str("container_id", id[:12]).
+ Float64("cpu_percent", result).
+ Float64("total_delta", totalDelta).
+ Float64("elapsed_seconds", elapsed).
+ Uint32("online_cpus", onlineCPUs).
+ Msg("CPU calculated from time-based delta")
+ return result
}
}
}
+ a.logger.Debug().
+ Str("container_id", id[:12]).
+ Float64("total_delta", totalDelta).
+ Float64("system_delta", systemDelta).
+ Bool("prev_read_zero", prev.read.IsZero()).
+ Bool("current_read_zero", current.read.IsZero()).
+ Msg("CPU calculation failed: no valid delta method available")
return 0
}