Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
Document cross-source disk identity contract
pulse-triage[bot]b9d69d029a5a
diff --git a/docs/release-control/v6/internal/subsystems/monitoring.md b/docs/release-control/v6/internal/subsystems/monitoring.mdindex a6141c7b9e..6fa2aee574 100644--- a/docs/release-control/v6/internal/subsystems/monitoring.md+++ b/docs/release-control/v6/internal/subsystems/monitoring.md@@ -328,9 +328,13 @@ permission-denied `disks/list` call must remain an error so the monitor can uselinked host-agent inventory or retain same-instance, same-node prior evidence;it must never become a successful empty inventory that removes valid boot ordata disks. SMART enrichment matches serial, WWN, device path, and controller-member topology uniquely and fail-closed, rejects placeholder hardware-identifiers, preserves explicit failure over a later coarse healthy value, and-lets explicit SMART endurance replace contradictory Proxmox wearout. Missing+member topology uniquely and fail-closed. Serial and WWN are interchangeable+hardware-identity carriers across reporters: comparison may case-fold and+remove only `naa.`, `eui.`, `wwn-`, and `0x` framing, but must reject+placeholders and must not truncate values, because sibling RAID volumes can+share a shortened WWN prefix. Enrichment preserves explicit failure over a+later coarse healthy value and lets explicit SMART endurance replace+contradictory Proxmox wearout. Missingpermission, ambiguous identity, standby, and absent SMART fields remainneutral rather than borrowing telemetry from another disk.Negative percentage-used counters remain unknown; values above 100 clamp to@@ -1170,6 +1174,18 @@ cleanup so readers cannot retain orphaned runtime or alert projections.## Current State+### Proxmox and agent disk observations share full hardware identity++PVE may publish a RAID array volume's full NAA value as a bare serial while+smartctl publishes the same value as an `naa.`-prefixed WWN. Monitoring's+cross-source join compares those serial/WWN carriers after framing-only+normalization, preserving full-length equality so a controller's sibling+volumes cannot collapse through a common truncated udev WWN. Placeholder+identifiers remain non-evidence. `pkg/diskinventory/identity_test.go`+(`TestHardwareIdentityMatch`) and `internal/unifiedresources/registry_test.go`+(`TestIssue1720ArrayVolumeMergesBareSerialWithPrefixedWWN`) are the focused+proofs.+### Proxmox node network inventory is secondary and continuity-safeOnline PVE node polls read `/nodes/{node}/network` through an optional clientdiff --git a/docs/release-control/v6/internal/subsystems/unified-resources.md b/docs/release-control/v6/internal/subsystems/unified-resources.mdindex c2de2772dc..31ef4f61fe 100644--- a/docs/release-control/v6/internal/subsystems/unified-resources.md+++ b/docs/release-control/v6/internal/subsystems/unified-resources.md@@ -110,7 +110,13 @@ misrepresented as Proxmox disk telemetry.Physical-disk matching is parent-scoped and topology-aware: persisted sourcemappings survive registry rebuilds, controller members sharing a block pathremain distinct, placeholder serials/WWNs never become canonical or metrics-identity, and ambiguous matches fail closed. SMART counter metadata preserves+identity, and ambiguous matches fail closed. Serial and WWN are alternate+representations of the same durable hardware identity across reporters, so a+value in either field may match a value in either field after case folding and+removing only reporter framing (`naa.`, `eui.`, `wwn-`, and `0x`). Matching+must never truncate an identifier or accept a placeholder: a shortened WWN+shared by sibling RAID volumes is not proof that either full identifier is the+same device. SMART counter metadata preservespresence through pointer-valued JSON fields, so reported zero is distinct frommissing. The canonical disk payload also carries provider vendor metadata anduses explicit SMART health, temperature, and wearout ahead of coarser@@ -2516,6 +2522,15 @@ the five field statuses for serial, temperature, I/O, controller, and pool.continuity, but the state and reason must survive so the consumer cannot claimfresh evidence or synthesize controller-level activity for one member.+Cross-source correlation compares normalized serial and WWN values across+fields without truncation, allowing a PVE bare-hex array-volume serial to join+the same smartctl `naa.` WWN while keeping sibling volumes with a common short+WWN distinct. `pkg/diskinventory/identity_test.go` (`TestHardwareIdentityMatch`)+pins framing, symmetry, placeholder, and no-truncation behavior;+`internal/unifiedresources/registry_test.go`+(`TestIssue1720ArrayVolumeMergesBareSerialWithPrefixedWWN`) pins the merged+Proxmox-plus-agent resource boundary.+### Canonical identity successionConnection-backed TrueNAS systems keep connection-scoped canonical IDs across