Skip to content

armgit / Pulse

Public Imported from GitHub
0

Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.

test: Add CheckDiskHealth normal path tests

rcourtmane644c38071b8
diff --git a/internal/alerts/alerts_test.go b/internal/alerts/alerts_test.go
index 460b4509a7..b09086f5ba 100644
--- a/internal/alerts/alerts_test.go
+++ b/internal/alerts/alerts_test.go
@@ -1715,6 +1715,292 @@ func TestCheckDiskHealthClearsExistingSamsung980Alerts(t *testing.T) {
}
}
+func TestCheckDiskHealthHealthyDiskNoAlert(t *testing.T) {
+ m := newTestManager(t)
+ m.ClearActiveAlerts()
+
+ // Non-Samsung disk with PASSED health should not create alert
+ disk := proxmox.Disk{
+ DevPath: "/dev/sda",
+ Model: "Western Digital WD40EFZX",
+ Serial: "WD-WCC4E0123456",
+ Type: "hdd",
+ Health: "PASSED",
+ Wearout: 0, // N/A for HDD
+ Size: 4000787030016,
+ }
+
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ healthAlertID := "disk-health-test-instance-pve-node1-/dev/sda"
+ if _, exists := m.activeAlerts[healthAlertID]; exists {
+ m.mu.RUnlock()
+ t.Fatalf("expected no health alert for healthy disk with PASSED status")
+ }
+ m.mu.RUnlock()
+
+ // Also test with "OK" status
+ disk.Health = "OK"
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ defer m.mu.RUnlock()
+ if _, exists := m.activeAlerts[healthAlertID]; exists {
+ t.Fatalf("expected no health alert for healthy disk with OK status")
+ }
+}
+
+func TestCheckDiskHealthFailedDiskCreatesAlert(t *testing.T) {
+ m := newTestManager(t)
+ m.ClearActiveAlerts()
+
+ // Non-Samsung disk with FAILED health should create alert
+ disk := proxmox.Disk{
+ DevPath: "/dev/sdb",
+ Model: "Seagate ST2000DM008",
+ Serial: "ZA123456",
+ Type: "hdd",
+ Health: "FAILED",
+ Wearout: 0,
+ Size: 2000398934016,
+ }
+
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ defer m.mu.RUnlock()
+
+ healthAlertID := "disk-health-test-instance-pve-node1-/dev/sdb"
+ alert, exists := m.activeAlerts[healthAlertID]
+ if !exists {
+ t.Fatalf("expected health alert to be created for failed disk")
+ }
+
+ if alert.Level != AlertLevelCritical {
+ t.Errorf("expected critical alert level, got %s", alert.Level)
+ }
+ if alert.Type != "disk-health" {
+ t.Errorf("expected type disk-health, got %s", alert.Type)
+ }
+ if alert.Node != "pve-node1" {
+ t.Errorf("expected node pve-node1, got %s", alert.Node)
+ }
+ if alert.Instance != "test-instance" {
+ t.Errorf("expected instance test-instance, got %s", alert.Instance)
+ }
+}
+
+func TestCheckDiskHealthRecoveryAlertCleared(t *testing.T) {
+ m := newTestManager(t)
+ m.ClearActiveAlerts()
+
+ disk := proxmox.Disk{
+ DevPath: "/dev/sdc",
+ Model: "Intel SSDSC2BB480G4",
+ Serial: "BTWL123456789",
+ Type: "ssd",
+ Health: "FAILED",
+ Wearout: 50,
+ Size: 480103981056,
+ }
+
+ // First check creates alert
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ healthAlertID := "disk-health-test-instance-pve-node1-/dev/sdc"
+ m.mu.RLock()
+ if _, exists := m.activeAlerts[healthAlertID]; !exists {
+ m.mu.RUnlock()
+ t.Fatalf("expected health alert to be created")
+ }
+ m.mu.RUnlock()
+
+ // Disk health recovers
+ disk.Health = "PASSED"
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ defer m.mu.RUnlock()
+ if _, exists := m.activeAlerts[healthAlertID]; exists {
+ t.Fatalf("expected health alert to be cleared after recovery")
+ }
+}
+
+func TestCheckDiskHealthLowWearoutCreatesAlert(t *testing.T) {
+ m := newTestManager(t)
+ m.ClearActiveAlerts()
+
+ // SSD with low wearout (less than 10% life remaining)
+ disk := proxmox.Disk{
+ DevPath: "/dev/nvme1n1",
+ Model: "Crucial CT1000MX500",
+ Serial: "12345678ABCD",
+ Type: "nvme",
+ Health: "PASSED",
+ Wearout: 5, // Only 5% life remaining
+ Size: 1000204886016,
+ }
+
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ defer m.mu.RUnlock()
+
+ wearoutAlertID := "disk-wearout-test-instance-pve-node1-/dev/nvme1n1"
+ alert, exists := m.activeAlerts[wearoutAlertID]
+ if !exists {
+ t.Fatalf("expected wearout alert to be created for disk with low life remaining")
+ }
+
+ if alert.Level != AlertLevelWarning {
+ t.Errorf("expected warning alert level, got %s", alert.Level)
+ }
+ if alert.Type != "disk-wearout" {
+ t.Errorf("expected type disk-wearout, got %s", alert.Type)
+ }
+ if alert.Value != 5 {
+ t.Errorf("expected value 5, got %f", alert.Value)
+ }
+ if alert.Threshold != 10.0 {
+ t.Errorf("expected threshold 10.0, got %f", alert.Threshold)
+ }
+}
+
+func TestCheckDiskHealthWearoutAlertUpdatesOnSubsequentChecks(t *testing.T) {
+ m := newTestManager(t)
+ m.ClearActiveAlerts()
+
+ disk := proxmox.Disk{
+ DevPath: "/dev/nvme2n1",
+ Model: "Kingston SA2000M8",
+ Serial: "50026B768A123456",
+ Type: "nvme",
+ Health: "PASSED",
+ Wearout: 8,
+ Size: 500107862016,
+ }
+
+ // First check creates alert
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ wearoutAlertID := "disk-wearout-test-instance-pve-node1-/dev/nvme2n1"
+ m.mu.RLock()
+ alert, exists := m.activeAlerts[wearoutAlertID]
+ if !exists {
+ m.mu.RUnlock()
+ t.Fatalf("expected wearout alert to be created")
+ }
+ firstLastSeen := alert.LastSeen
+ m.mu.RUnlock()
+
+ // Wait a moment to ensure time difference
+ time.Sleep(10 * time.Millisecond)
+
+ // Wearout decreases further
+ disk.Wearout = 6
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ defer m.mu.RUnlock()
+
+ alert, exists = m.activeAlerts[wearoutAlertID]
+ if !exists {
+ t.Fatalf("expected wearout alert to still exist")
+ }
+
+ if !alert.LastSeen.After(firstLastSeen) {
+ t.Errorf("expected LastSeen to be updated, got %v (original: %v)", alert.LastSeen, firstLastSeen)
+ }
+ if alert.Value != 6 {
+ t.Errorf("expected value to be updated to 6, got %f", alert.Value)
+ }
+}
+
+func TestCheckDiskHealthWearoutRecoveryAlertCleared(t *testing.T) {
+ m := newTestManager(t)
+ m.ClearActiveAlerts()
+
+ disk := proxmox.Disk{
+ DevPath: "/dev/sdd",
+ Model: "ADATA SU800",
+ Serial: "2J012345678",
+ Type: "ssd",
+ Health: "PASSED",
+ Wearout: 5,
+ Size: 256060514304,
+ }
+
+ // First check creates wearout alert
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ wearoutAlertID := "disk-wearout-test-instance-pve-node1-/dev/sdd"
+ m.mu.RLock()
+ if _, exists := m.activeAlerts[wearoutAlertID]; !exists {
+ m.mu.RUnlock()
+ t.Fatalf("expected wearout alert to be created")
+ }
+ m.mu.RUnlock()
+
+ // Wearout recovers (replaced drive, or misread corrected)
+ disk.Wearout = 95
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ defer m.mu.RUnlock()
+ if _, exists := m.activeAlerts[wearoutAlertID]; exists {
+ t.Fatalf("expected wearout alert to be cleared after recovery")
+ }
+}
+
+func TestCheckDiskHealthEmptyOrUnknownHealthNoAlert(t *testing.T) {
+ m := newTestManager(t)
+ m.ClearActiveAlerts()
+
+ disk := proxmox.Disk{
+ DevPath: "/dev/sde",
+ Model: "Generic USB Storage",
+ Serial: "USB123456",
+ Type: "hdd",
+ Health: "", // Empty health - SMART not supported
+ Wearout: 0,
+ Size: 128043712512,
+ }
+
+ healthAlertID := "disk-health-test-instance-pve-node1-/dev/sde"
+
+ // Empty health should not create alert
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ if _, exists := m.activeAlerts[healthAlertID]; exists {
+ m.mu.RUnlock()
+ t.Fatalf("expected no health alert for disk with empty health status")
+ }
+ m.mu.RUnlock()
+
+ // UNKNOWN health should not create alert
+ disk.Health = "UNKNOWN"
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ if _, exists := m.activeAlerts[healthAlertID]; exists {
+ m.mu.RUnlock()
+ t.Fatalf("expected no health alert for disk with UNKNOWN health status")
+ }
+ m.mu.RUnlock()
+
+ // Lowercase "unknown" should also not create alert (normalized to uppercase)
+ disk.Health = "unknown"
+ m.CheckDiskHealth("test-instance", "pve-node1", disk)
+
+ m.mu.RLock()
+ defer m.mu.RUnlock()
+ if _, exists := m.activeAlerts[healthAlertID]; exists {
+ t.Fatalf("expected no health alert for disk with lowercase unknown health status")
+ }
+}
+
func TestDisableAllStorageClearsExistingAlerts(t *testing.T) {
m := newTestManager(t)