Real-time monitoring dashboard for Proxmox VE, PBS, Docker, Kubernetes, TrueNAS and vSphere. Self-hosted, with alerts for failed backups, full disks, unhealthy containers and offline nodes.
Go aialertsdashboarddockerdocker-monitoringgohomelabinfrastructure-monitoringkubernetesmonitoringmspproxmoxproxmox-backup-serverproxmox-mail-gatewayproxmox-veself-hostedtruenastypescriptvspherewebhooks
test: Add CheckDiskHealth normal path tests
rcourtmane644c38071b8
diff --git a/internal/alerts/alerts_test.go b/internal/alerts/alerts_test.goindex 460b4509a7..b09086f5ba 100644--- a/internal/alerts/alerts_test.go+++ b/internal/alerts/alerts_test.go@@ -1715,6 +1715,292 @@ func TestCheckDiskHealthClearsExistingSamsung980Alerts(t *testing.T) {}}+func TestCheckDiskHealthHealthyDiskNoAlert(t *testing.T) {+ m := newTestManager(t)+ m.ClearActiveAlerts()++ // Non-Samsung disk with PASSED health should not create alert+ disk := proxmox.Disk{+ DevPath: "/dev/sda",+ Model: "Western Digital WD40EFZX",+ Serial: "WD-WCC4E0123456",+ Type: "hdd",+ Health: "PASSED",+ Wearout: 0, // N/A for HDD+ Size: 4000787030016,+ }++ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ healthAlertID := "disk-health-test-instance-pve-node1-/dev/sda"+ if _, exists := m.activeAlerts[healthAlertID]; exists {+ m.mu.RUnlock()+ t.Fatalf("expected no health alert for healthy disk with PASSED status")+ }+ m.mu.RUnlock()++ // Also test with "OK" status+ disk.Health = "OK"+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ defer m.mu.RUnlock()+ if _, exists := m.activeAlerts[healthAlertID]; exists {+ t.Fatalf("expected no health alert for healthy disk with OK status")+ }+}++func TestCheckDiskHealthFailedDiskCreatesAlert(t *testing.T) {+ m := newTestManager(t)+ m.ClearActiveAlerts()++ // Non-Samsung disk with FAILED health should create alert+ disk := proxmox.Disk{+ DevPath: "/dev/sdb",+ Model: "Seagate ST2000DM008",+ Serial: "ZA123456",+ Type: "hdd",+ Health: "FAILED",+ Wearout: 0,+ Size: 2000398934016,+ }++ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ defer m.mu.RUnlock()++ healthAlertID := "disk-health-test-instance-pve-node1-/dev/sdb"+ alert, exists := m.activeAlerts[healthAlertID]+ if !exists {+ t.Fatalf("expected health alert to be created for failed disk")+ }++ if alert.Level != AlertLevelCritical {+ t.Errorf("expected critical alert level, got %s", alert.Level)+ }+ if alert.Type != "disk-health" {+ t.Errorf("expected type disk-health, got %s", alert.Type)+ }+ if alert.Node != "pve-node1" {+ t.Errorf("expected node pve-node1, got %s", alert.Node)+ }+ if alert.Instance != "test-instance" {+ t.Errorf("expected instance test-instance, got %s", alert.Instance)+ }+}++func TestCheckDiskHealthRecoveryAlertCleared(t *testing.T) {+ m := newTestManager(t)+ m.ClearActiveAlerts()++ disk := proxmox.Disk{+ DevPath: "/dev/sdc",+ Model: "Intel SSDSC2BB480G4",+ Serial: "BTWL123456789",+ Type: "ssd",+ Health: "FAILED",+ Wearout: 50,+ Size: 480103981056,+ }++ // First check creates alert+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ healthAlertID := "disk-health-test-instance-pve-node1-/dev/sdc"+ m.mu.RLock()+ if _, exists := m.activeAlerts[healthAlertID]; !exists {+ m.mu.RUnlock()+ t.Fatalf("expected health alert to be created")+ }+ m.mu.RUnlock()++ // Disk health recovers+ disk.Health = "PASSED"+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ defer m.mu.RUnlock()+ if _, exists := m.activeAlerts[healthAlertID]; exists {+ t.Fatalf("expected health alert to be cleared after recovery")+ }+}++func TestCheckDiskHealthLowWearoutCreatesAlert(t *testing.T) {+ m := newTestManager(t)+ m.ClearActiveAlerts()++ // SSD with low wearout (less than 10% life remaining)+ disk := proxmox.Disk{+ DevPath: "/dev/nvme1n1",+ Model: "Crucial CT1000MX500",+ Serial: "12345678ABCD",+ Type: "nvme",+ Health: "PASSED",+ Wearout: 5, // Only 5% life remaining+ Size: 1000204886016,+ }++ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ defer m.mu.RUnlock()++ wearoutAlertID := "disk-wearout-test-instance-pve-node1-/dev/nvme1n1"+ alert, exists := m.activeAlerts[wearoutAlertID]+ if !exists {+ t.Fatalf("expected wearout alert to be created for disk with low life remaining")+ }++ if alert.Level != AlertLevelWarning {+ t.Errorf("expected warning alert level, got %s", alert.Level)+ }+ if alert.Type != "disk-wearout" {+ t.Errorf("expected type disk-wearout, got %s", alert.Type)+ }+ if alert.Value != 5 {+ t.Errorf("expected value 5, got %f", alert.Value)+ }+ if alert.Threshold != 10.0 {+ t.Errorf("expected threshold 10.0, got %f", alert.Threshold)+ }+}++func TestCheckDiskHealthWearoutAlertUpdatesOnSubsequentChecks(t *testing.T) {+ m := newTestManager(t)+ m.ClearActiveAlerts()++ disk := proxmox.Disk{+ DevPath: "/dev/nvme2n1",+ Model: "Kingston SA2000M8",+ Serial: "50026B768A123456",+ Type: "nvme",+ Health: "PASSED",+ Wearout: 8,+ Size: 500107862016,+ }++ // First check creates alert+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ wearoutAlertID := "disk-wearout-test-instance-pve-node1-/dev/nvme2n1"+ m.mu.RLock()+ alert, exists := m.activeAlerts[wearoutAlertID]+ if !exists {+ m.mu.RUnlock()+ t.Fatalf("expected wearout alert to be created")+ }+ firstLastSeen := alert.LastSeen+ m.mu.RUnlock()++ // Wait a moment to ensure time difference+ time.Sleep(10 * time.Millisecond)++ // Wearout decreases further+ disk.Wearout = 6+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ defer m.mu.RUnlock()++ alert, exists = m.activeAlerts[wearoutAlertID]+ if !exists {+ t.Fatalf("expected wearout alert to still exist")+ }++ if !alert.LastSeen.After(firstLastSeen) {+ t.Errorf("expected LastSeen to be updated, got %v (original: %v)", alert.LastSeen, firstLastSeen)+ }+ if alert.Value != 6 {+ t.Errorf("expected value to be updated to 6, got %f", alert.Value)+ }+}++func TestCheckDiskHealthWearoutRecoveryAlertCleared(t *testing.T) {+ m := newTestManager(t)+ m.ClearActiveAlerts()++ disk := proxmox.Disk{+ DevPath: "/dev/sdd",+ Model: "ADATA SU800",+ Serial: "2J012345678",+ Type: "ssd",+ Health: "PASSED",+ Wearout: 5,+ Size: 256060514304,+ }++ // First check creates wearout alert+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ wearoutAlertID := "disk-wearout-test-instance-pve-node1-/dev/sdd"+ m.mu.RLock()+ if _, exists := m.activeAlerts[wearoutAlertID]; !exists {+ m.mu.RUnlock()+ t.Fatalf("expected wearout alert to be created")+ }+ m.mu.RUnlock()++ // Wearout recovers (replaced drive, or misread corrected)+ disk.Wearout = 95+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ defer m.mu.RUnlock()+ if _, exists := m.activeAlerts[wearoutAlertID]; exists {+ t.Fatalf("expected wearout alert to be cleared after recovery")+ }+}++func TestCheckDiskHealthEmptyOrUnknownHealthNoAlert(t *testing.T) {+ m := newTestManager(t)+ m.ClearActiveAlerts()++ disk := proxmox.Disk{+ DevPath: "/dev/sde",+ Model: "Generic USB Storage",+ Serial: "USB123456",+ Type: "hdd",+ Health: "", // Empty health - SMART not supported+ Wearout: 0,+ Size: 128043712512,+ }++ healthAlertID := "disk-health-test-instance-pve-node1-/dev/sde"++ // Empty health should not create alert+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ if _, exists := m.activeAlerts[healthAlertID]; exists {+ m.mu.RUnlock()+ t.Fatalf("expected no health alert for disk with empty health status")+ }+ m.mu.RUnlock()++ // UNKNOWN health should not create alert+ disk.Health = "UNKNOWN"+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ if _, exists := m.activeAlerts[healthAlertID]; exists {+ m.mu.RUnlock()+ t.Fatalf("expected no health alert for disk with UNKNOWN health status")+ }+ m.mu.RUnlock()++ // Lowercase "unknown" should also not create alert (normalized to uppercase)+ disk.Health = "unknown"+ m.CheckDiskHealth("test-instance", "pve-node1", disk)++ m.mu.RLock()+ defer m.mu.RUnlock()+ if _, exists := m.activeAlerts[healthAlertID]; exists {+ t.Fatalf("expected no health alert for disk with lowercase unknown health status")+ }+}+func TestDisableAllStorageClearsExistingAlerts(t *testing.T) {m := newTestManager(t)