Strip nvme namespace suffixes in the server disk-to-pool matcher

rcourtmanea524c9229cd
diff --git a/internal/monitoring/physical_disk_pool_membership.go b/internal/monitoring/physical_disk_pool_membership.go
index 209317309f..7f38710918 100644
--- a/internal/monitoring/physical_disk_pool_membership.go
+++ b/internal/monitoring/physical_disk_pool_membership.go
@@ -204,6 +204,9 @@ func serialFromByID(raw string) string {
if strings.HasPrefix(name, "nvme-eui.") {
return strings.TrimPrefix(name, "nvme-eui.")
}
+ // systemd's nvme by-id links can carry a trailing _<n> namespace suffix
+ // (nvme-MODEL_SERIAL_1); the serial is the token before it (#1540).
+ name = stripNVMeNamespaceSuffix(name)
// The last underscore-separated token is typically the serial.
if idx := strings.LastIndex(name, "_"); idx > 0 {
return name[idx+1:]
@@ -217,6 +220,28 @@ func serialFromByID(raw string) string {
return ""
}
+// stripNVMeNamespaceSuffix removes the trailing _<n> namespace token systemd
+// appends to nvme by-id link names (nvme-MODEL_SERIAL_1). Only short all-digit
+// tokens are stripped, and only when another underscore token remains, so a
+// genuine serial is never truncated.
+func stripNVMeNamespaceSuffix(name string) string {
+ if !strings.HasPrefix(name, "nvme-") {
+ return name
+ }
+ idx := strings.LastIndex(name, "_")
+ if idx <= 0 {
+ return name
+ }
+ suffix := name[idx+1:]
+ if len(suffix) == 0 || len(suffix) > 3 || !allDigits(suffix) {
+ return name
+ }
+ if !strings.Contains(name[:idx], "_") {
+ return name
+ }
+ return name[:idx]
+}
+
func allDigits(s string) bool {
for i := 0; i < len(s); i++ {
if !isDigit(s[i]) {
diff --git a/internal/monitoring/physical_disk_pool_membership_test.go b/internal/monitoring/physical_disk_pool_membership_test.go
index 4cebdf6cc3..2a766cf4b9 100644
--- a/internal/monitoring/physical_disk_pool_membership_test.go
+++ b/internal/monitoring/physical_disk_pool_membership_test.go
@@ -40,6 +40,14 @@ func TestDiskPoolAssignmentLookup(t *testing.T) {
{Name: "/dev/disk/by-id/nvme-eui.0025385b91501234-part3", Leaf: 1},
},
},
+ {
+ Name: "local-zfs",
+ Devices: []proxmox.ZFSPoolDevice{
+ // systemd nvme by-id link with a trailing _1 namespace suffix,
+ // as reported on #1540's pve01.
+ {Name: "/dev/disk/by-id/nvme-Samsung_SSD_990_PRO_4TB_S7DPNF0Y316714T_1-part1", Leaf: 1},
+ },
+ },
}
assignment := buildDiskPoolAssignment(pools)
@@ -64,6 +72,11 @@ func TestDiskPoolAssignmentLookup(t *testing.T) {
disk: models.PhysicalDisk{DevPath: "/dev/nvme0n1", WWN: "0x0025385b91501234"},
want: "flash",
},
+ {
+ label: "nvme by-id leaf with namespace suffix matches disk serial",
+ disk: models.PhysicalDisk{DevPath: "/dev/nvme2n1", Serial: "S7DPNF0Y316714T"},
+ want: "local-zfs",
+ },
{
label: "short leaf name matches partition-stripped devpath",
disk: models.PhysicalDisk{DevPath: "/dev/sdc"},