Keep a split PVE disk off the agent's SMART row

rcourtmanec5075897413
diff --git a/docs/release-control/v6/internal/subsystems/agent-lifecycle.md b/docs/release-control/v6/internal/subsystems/agent-lifecycle.md
index a089e0f234..2625c04957 100644
--- a/docs/release-control/v6/internal/subsystems/agent-lifecycle.md
+++ b/docs/release-control/v6/internal/subsystems/agent-lifecycle.md
@@ -401,6 +401,20 @@ wire contract and Agent authority are unchanged;
`internal/monitoring/physical_disk_roundtrip_test.go` and
`TestPhysicalDiskAgentSMARTReportedStaysInternal` in
`internal/models/deepcopy_test.go` pin the marker.
+A PVE disk the operator split from the Agent's disk (report-merge on the merged
+disk) is paired with no SMART row of the linked Agent and, from the first full
+disk poll that matches the Agent's row, shows none of the Agent's temperature,
+including the node sensor reading the node poll took from that Agent's report
+while it is reporting, so the Agent's `CheckHost` owns the temperature alert of
+the Agent's own disk only and the PVE disk check has no Agent-supplied reading
+of the Proxmox disk to alert on beside it: the split disk is marked `AgentSMARTSplit` (internal poll
+evidence on `models.PhysicalDisk`, never serialized) instead of
+`AgentSMARTReported`. Report admission, the SMART wire contract and Agent
+authority are unchanged: the Agent still reports the row, and the split only
+decides whose disk it is on the server;
+`TestOperatorSplitKeepsAgentSMARTOffTheProxmoxDisk` in
+`internal/monitoring/physical_disk_roundtrip_test.go` and
+`TestPhysicalDiskAgentSMARTReportedStaysInternal` pin it.
Assistant historical metric wiring uses the current monitor's retained store
and registry metrics coordinates. Historical reads do not alter enrollment,
diff --git a/docs/release-control/v6/internal/subsystems/monitoring.md b/docs/release-control/v6/internal/subsystems/monitoring.md
index df749fdb7f..d74eb5f09d 100644
--- a/docs/release-control/v6/internal/subsystems/monitoring.md
+++ b/docs/release-control/v6/internal/subsystems/monitoring.md
@@ -2434,6 +2434,48 @@ merge, so on a mock estate every hot disk on an online node alerts.
`internal/monitoring/physical_disk_roundtrip_test.go` pin the marker,
the collected reading, agent ownership and exclusion.
+A disk the operator split from the agent's disk (report-merge on the merged
+disk) is not paired with the agent's row. `mergeHostAgentSMARTIntoDisks` asks
+the resource store, through `diskAgentSplitStore`
+(`unifiedresources.MonitorAdapter.ProxmoxDiskAgentSMARTSplit`), once per disk
+it matches a row to, on the full poll and on the skipped polls between, and a
+split disk takes nothing from the row: no attributes, I/O, health, identity,
+type or temperature, and no `AgentSMARTReported`. It takes no agent-supplied
+node-sensor temperature either: the node poll takes the node's SMART list from
+the linked agent when the agent's report carries a usable temperature
+(`mergeTemperatureData`; `hostSuppliesNodeSMARTTemperatures` mirrors that
+rule), and its legacy NVMe list is matched by order, so
+`dropNodeSensorTemperature` removes a reading `mergeNVMeTempsIntoDisks` took
+from either, leaving the PVE disk check no such reading to judge beside the
+agent's own alert, while a reading from the SSH collector's list stays (the
+rule needs the agent still reporting). The
+split disk is still evaluated by `checkPhysicalDiskAlerts` whenever its node
+is polled. It is marked
+`AgentSMARTSplit` (internal poll evidence, never serialized), so the poll's
+retention of unavailable evidence restores nothing into it. The decider is
+asked about the observation under its own ID, as the registry holds it. The
+Proxmox-query-failure fallback omits the rows the operator split from the disk
+in their slot, so while the query fails that disk's Proxmox record is not
+listed (a node every row of which is split keeps its last records, and is not
+evaluated by `checkPhysicalDiskAlerts`, as any unqueried node). A store that holds no
+decisions, or none for the pair, leaves the merge as it was. The decision
+comes from the registry generation the monitor last built, so a split applies
+from the first full disk poll that collects the node from Proxmox and matches
+the agent's row after the rebuild that loaded it; the skipped polls before then
+mark the record and drop its node-sensor temperature but leave what an earlier
+poll merged into it.
+`TestMergeHostAgentSMARTIntoDisksLeavesDisksTheOperatorSplitAlone`,
+`TestHostAgentSMARTFallbackSkipsRowsTheOperatorSplit`,
+`TestFailedDiskQueryListsOnlyTheRowsTheOperatorDidNotSplit`,
+`TestMergeHostAgentSMARTIntoDisksKeepsSSHNodeSensorReadingOfSplitDisk`,
+`TestDropNodeSensorTemperatureRemovesOnlyAgentSuppliedReadings`,
+`TestMergeNVMeTempsLabelsReadingsWithTheNodeSensorSources`,
+`TestHostSuppliesNodeSMARTTemperaturesFollowsUsableReadings` and
+`TestOperatorSplitKeepsAgentSMARTOffTheProxmoxDisk` in
+`internal/monitoring/physical_disk_roundtrip_test.go` pin the merge, the
+fallback and the poller end to end, and `TestProxmoxDiskAlertsRunOnMergedDiskState`
+in `canonical_guardrails_test.go` pins the signature and call.
+
Switching mock mode fences the alert evaluations that read mode-dependent data
(`mockModeFence`, `internal/monitoring/mock_mode_fence.go`). `GetState`, the
fixture graph, the unified read view, the recovery rollups and the connection
diff --git a/docs/release-control/v6/internal/subsystems/unified-resources.md b/docs/release-control/v6/internal/subsystems/unified-resources.md
index 33200622df..eb6b8fd3a7 100644
--- a/docs/release-control/v6/internal/subsystems/unified-resources.md
+++ b/docs/release-control/v6/internal/subsystems/unified-resources.md
@@ -7252,13 +7252,68 @@ every merged source. The monitor rebuild and a resources API registry built from
snapshot apply the split on their next build; the registry seeded from the
monitor's listing follows once the monitor has rebuilt.
-What the split does not reach. The PVE disk poller's
-`mergeHostAgentSMARTIntoDisks` pairs the linked agent's SMART rows with
-Proxmox disks by WWN, serial or path before the registry sees them and reads
-no exclusions, so the split Proxmox row still carries the agent's SMART
-attributes and I/O, its health where it reports a failure or Proxmox none,
-and any serial, WWN, type or temperature it filled, and the agent keeps the
-disk's temperature alert while it reports (`AgentSMARTReported`). Two split
+The PVE disk poller honours the split too. `mergeHostAgentSMARTIntoDisks`
+pairs the linked agent's SMART rows with Proxmox disks by WWN, serial or path
+before the registry sees either, and asks
+`MonitorAdapter.ProxmoxDiskAgentSMARTSplit`
+(`internal/unifiedresources/physical_disk_agent_split.go`) about each pair it
+is about to make. The answer is `physicalDiskSplitLocked`'s, applied to the
+agent's disk as the registry generation holds it (as its row would key it
+when the generation does not hold it) and to the Proxmox observation by its
+slot's source-specific candidate ID, so the exclusions that keep the
+registry's rows apart keep the poller's pair apart, in the same forms: one
+naming only the agent's candidate splits nothing, a replacement in the slot
+inherits no split recorded against the disk it replaced, and a manual link
+that leaves the generation holding both observations as one disk is the
+operator's later decision, so the poller pairs them again while it stands. The
+decision reads the exclusions and that mapping, never what the pairing would
+fill into the Proxmox row, whose serial it re-keys. A split Proxmox row takes
+nothing from the agent's row: not its SMART attributes or I/O, health, serial,
+WWN, type, controller, pool or temperature, whether from the row or from the
+node's sensor lists. The node poll takes the SMART list from the linked agent
+while the agent is reporting and its report carries a usable temperature (the
+SSH collector's otherwise), and `mergeNVMeTempsIntoDisks` matches a list's rows
+to the disk by the same identity, so `dropNodeSensorTemperature` drops a
+reading taken from the agent's list, and the legacy NVMe list's guess by order,
+which names no disk, while a reading from the SSH collector's list stays. The
+rule is read from the agent's report as the disk poll sees it, so a report that
+changed since the node poll can misjudge one poll. Nor does the disk
+keep the agent's claim on its temperature alert (`AgentSMARTReported`): the
+agent's `CheckHost` alerts on the agent's own disk and the PVE disk check has
+no agent-supplied reading of the split disk to judge, so one reading never
+alerts twice, and Proxmox's own health and wearout verdicts of the disk are
+evaluated as for any disk. A refused row never makes another row match. The
+record is marked `AgentSMARTSplit`, so the poll's evidence retention
+(`preserveUnavailablePhysicalDiskEvidence`) restores nothing into it: nothing
+records which retained value Proxmox collected and which the agent filled, so
+its serial or ZFS pool is absent for a poll that cannot collect it and returns
+with the next that can, and a Proxmox serial that goes unreported for a poll
+can move the disk to a WWN- or slot-keyed ID, and its history to that key,
+until it returns. The decider is asked once per matched row, about the
+observation under its own ID, the key the registry holds it by, so the poller
+follows the registry exactly: a split recorded under another key of the same
+disk (a controller member's stand-in is keyed by its target, a Proxmox poll's
+record by device alone) names an observation the other key's rows do not
+carry, as for the registry. When the Proxmox disk query fails,
+`physicalDisksFromHostAgentSMART` stands in for the node's disks except for
+the rows the operator split from the Proxmox disk in their slot, judged under
+the stand-in's own ID. Such a disk gets no stand-in, which would be the
+agent's disk again, so while the query fails its Proxmox record is not listed
+unless every row of the node is split, when the node keeps its last records as
+any node Proxmox cannot be queried for does.
+
+What the split does not reach. The poller applies a split on the first full
+disk poll that collects the node from Proxmox and matches the agent's row
+after the registry generation holds it. Until then a Proxmox record already
+merged keeps the agent's data (the next full poll, five minutes by default,
+`PhysicalDiskPollingMinutes`): the skipped polls between mark the record split
+and drop its node-sensor temperature but leave the rest as it is, a node
+Proxmox cannot be queried for keeps its last records, and a poll in which
+the agent does not list the disk marks nothing, so retention restores the
+earlier record's temperature, I/O, controller, target, serial and pool as
+last-known evidence. The query-failure fallback judges its stand-in row by the
+row's own identity, so it does not apply a split that names identity only the
+Proxmox disk carries (an agent disk in standby reports no serial). Two split
rows that share a serial read one serial-keyed history
(`PhysicalDiskMetaMetricID`), and a PVE disk alert lifecycle row whose
recorded identity matches both, with no WWN only one of them shares, stays
@@ -7287,7 +7342,13 @@ the rebuilt listing or built from the snapshot, plain and for presentation;
then a relink of the split rows, the exclusions report-merge records on the
relinked disk (the link's own pair and both candidates), the agent's disk in
standby, a same-serial disk appearing on another machine, and a split
-recorded while such a disk was present that holds once it leaves.
+recorded while such a disk was present that holds once it leaves. At each of
+those steps the test also asks `ProxmoxDiskAgentSMARTSplit` what the poller
+would, and `TestOperatorSplitKeepsAgentSMARTOffTheProxmoxDisk` in
+`internal/monitoring/physical_disk_roundtrip_test.go` drives the poller itself
+through the same four requests for a SAS disk paired by path and an NVMe disk
+paired by serial, with an open PVE temperature alert, the health alert the
+agent's failure raised, and a failing Proxmox disk query.
### Seeded slot mapping refuses a replaced disk
diff --git a/internal/models/deepcopy_test.go b/internal/models/deepcopy_test.go
index e412d86406..9cbaaf038f 100644
--- a/internal/models/deepcopy_test.go
+++ b/internal/models/deepcopy_test.go
@@ -515,21 +515,24 @@ func TestCloneHostXCPNGInventoryIsolation(t *testing.T) {
}
}
-// AgentSMARTReported is internal poll evidence: a state snapshot copy keeps it
-// for the alert check, and it never reaches an API or websocket payload.
+// AgentSMARTReported and AgentSMARTSplit are internal poll evidence: a state
+// snapshot copy keeps them for the alert check and the poll's evidence
+// retention, and neither reaches an API or websocket payload.
func TestPhysicalDiskAgentSMARTReportedStaysInternal(t *testing.T) {
- disk := PhysicalDisk{ID: "lab-pve1-sda", DevPath: "/dev/sda", AgentSMARTReported: true}
- if clone := clonePhysicalDisk(disk); !clone.AgentSMARTReported {
- t.Fatalf("clone dropped AgentSMARTReported")
+ disk := PhysicalDisk{ID: "lab-pve1-sda", DevPath: "/dev/sda", AgentSMARTReported: true, AgentSMARTSplit: true}
+ if clone := clonePhysicalDisk(disk); !clone.AgentSMARTReported || !clone.AgentSMARTSplit {
+ t.Fatalf("clone dropped AgentSMARTReported/AgentSMARTSplit: %+v", clone)
}
- if clones := clonePhysicalDisks([]PhysicalDisk{disk}); !clones[0].AgentSMARTReported {
- t.Fatalf("slice clone dropped AgentSMARTReported")
+ if clones := clonePhysicalDisks([]PhysicalDisk{disk}); !clones[0].AgentSMARTReported || !clones[0].AgentSMARTSplit {
+ t.Fatalf("slice clone dropped AgentSMARTReported/AgentSMARTSplit: %+v", clones[0])
}
payload, err := json.Marshal(disk)
if err != nil {
t.Fatal(err)
}
- if strings.Contains(strings.ToLower(string(payload)), "agentsmartreported") {
- t.Fatalf("AgentSMARTReported leaked into JSON: %s", payload)
+ for _, field := range []string{"agentsmartreported", "agentsmartsplit"} {
+ if strings.Contains(strings.ToLower(string(payload)), field) {
+ t.Fatalf("%s leaked into JSON: %s", field, payload)
+ }
}
}
diff --git a/internal/models/models.go b/internal/models/models.go
index ceee0c30f3..6196eb682a 100644
--- a/internal/models/models.go
+++ b/internal/models/models.go
@@ -2859,8 +2859,13 @@ type PhysicalDisk struct {
// AgentSMARTReported marks a disk a linked host agent lists in its SMART
// report, so the agent's CheckHost owns its temperature alert. Internal
// poll evidence, set by the PVE disk poller's agent SMART merge.
- AgentSMARTReported bool `json:"-"`
- LastChecked time.Time `json:"lastChecked"`
+ AgentSMARTReported bool `json:"-"`
+ // AgentSMARTSplit marks a disk the operator split from the disk a linked
+ // host agent's SMART row describes, so the PVE disk poller pairs neither
+ // that row nor an earlier poll's record, which held its readings, with
+ // it. Internal poll evidence, set by the same merge.
+ AgentSMARTSplit bool `json:"-"`
+ LastChecked time.Time `json:"lastChecked"`
}
// PBSInstance represents a Proxmox Backup Server instance
diff --git a/internal/monitoring/canonical_guardrails_test.go b/internal/monitoring/canonical_guardrails_test.go
index 7d409f0fc0..f47fd60b1a 100644
--- a/internal/monitoring/canonical_guardrails_test.go
+++ b/internal/monitoring/canonical_guardrails_test.go
@@ -2268,7 +2268,7 @@ func TestProxmoxDiskAlertsRunOnMergedDiskState(t *testing.T) {
{
file: "monitor.go",
snippets: []string{
- "func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.Node, hosts []models.Host) []models.PhysicalDisk {",
+ "func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.Node, hosts []models.Host, splits diskAgentSplitStore) []models.PhysicalDisk {",
"deriveWearoutFromSMARTAttributes(matched.Attributes)",
"storagehealth.RemainingLifeFromPercentageUsed(*attrs.PercentageUsed)",
"shouldUseHostAgentPhysicalDiskHealth(updated[i].Health, matched.Health)",
@@ -2278,7 +2278,7 @@ func TestProxmoxDiskAlertsRunOnMergedDiskState(t *testing.T) {
{
file: "monitor_pve.go",
snippets: []string{
- "allDisks = mergeHostAgentSMARTIntoDisks(allDisks, nodesFromState, hosts)",
+ "allDisks = mergeHostAgentSMARTIntoDisks(allDisks, nodesFromState, hosts, splits)",
"m.checkPhysicalDiskAlerts(inst, disk, diskExcludeByNode[disk.Node])",
"m.alertManager.CheckDiskHealth(instance, disk.Node, proxmoxDiskFromPhysicalDisk(disk))",
"func proxmoxDiskFromPhysicalDisk(disk models.PhysicalDisk) proxmox.Disk {",
diff --git a/internal/monitoring/issue1595_collection_trust_test.go b/internal/monitoring/issue1595_collection_trust_test.go
index e3de00161e..79f5366ca5 100644
--- a/internal/monitoring/issue1595_collection_trust_test.go
+++ b/internal/monitoring/issue1595_collection_trust_test.go
@@ -148,7 +148,7 @@ func TestIssue1595SASTopologySurvivesMergeRegistryAndReadState(t *testing.T) {
}
}
- merged := mergeHostAgentSMARTIntoDisks(providerDisks, []models.Node{node}, []models.Host{host})
+ merged := mergeHostAgentSMARTIntoDisks(providerDisks, []models.Node{node}, []models.Host{host}, nil)
if len(merged) != 24 {
t.Fatalf("merged disk count = %d, want 24", len(merged))
}
@@ -286,6 +286,7 @@ func TestTrustedSMARTSerialPromotionDoesNotRewriteSATAOrNVMeIdentity(t *testing.
disks,
[]models.Node{{Name: "node", LinkedAgentID: "agent"}},
hosts,
+ nil,
)[0]
if got.Serial != "PROVIDER-SERIAL" || got.Type != diskType {
t.Fatalf("%s identity changed during SAS remediation: %+v", diskType, got)
@@ -948,6 +949,7 @@ func TestHostAgentSMARTMergeRefusesPathMatchAcrossContradictingIdentity(t *testi
[]models.Host{{ID: "agent-1", Sensors: models.HostSensorSummary{
SMART: append([]models.HostDiskSMART{tc.smart}, tc.others...),
}}},
+ nil,
)[0]
if !tc.merged {
if got.Serial != tc.disk.Serial || got.WWN != tc.disk.WWN || got.Type != tc.disk.Type ||
diff --git a/internal/monitoring/merge_temps_test.go b/internal/monitoring/merge_temps_test.go
index a95ada4b46..87f5f884a0 100644
--- a/internal/monitoring/merge_temps_test.go
+++ b/internal/monitoring/merge_temps_test.go
@@ -394,7 +394,7 @@ func TestMergeHostAgentSMARTIntoDisks_EnrichesMissingIdentityAndZFSPool(t *testi
},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if len(result) != 1 {
t.Fatalf("got %d disks, want 1", len(result))
}
@@ -465,7 +465,7 @@ func TestMergeHostAgentSMARTIntoDisks_PreservesExistingProxmoxIdentity(t *testin
},
}
- got := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)[0]
+ got := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)[0]
if got.Model != "Proxmox Model" || got.Serial != "PVE-SERIAL" || got.WWN != "0x5000c500a1b2c3d4" || got.Type != "sas" {
t.Fatalf("existing Proxmox identity was overwritten: %+v", got)
}
diff --git a/internal/monitoring/monitor.go b/internal/monitoring/monitor.go
index 0f732f9327..72aff4182a 100644
--- a/internal/monitoring/monitor.go
+++ b/internal/monitoring/monitor.go
@@ -390,7 +390,7 @@ func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) [
return diskinventory.IsUsableHardwareID(candidate.WWN) &&
strings.EqualFold(candidate.WWN, updated[i].WWN)
}); temp != nil && temp.Temperature > 0 && !temp.StandbySkipped {
- setPhysicalDiskTemperature(&updated[i], temp.Temperature, "proxmox_node_smart")
+ setPhysicalDiskTemperature(&updated[i], temp.Temperature, proxmoxNodeSMARTTemperatureSource)
log.Debug().
Str("disk", updated[i].DevPath).
Str("wwn", updated[i].WWN).
@@ -405,7 +405,7 @@ func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) [
return diskinventory.IsUsableHardwareID(candidate.Serial) &&
strings.EqualFold(candidate.Serial, updated[i].Serial)
}); temp != nil && temp.Temperature > 0 && !temp.StandbySkipped {
- setPhysicalDiskTemperature(&updated[i], temp.Temperature, "proxmox_node_smart")
+ setPhysicalDiskTemperature(&updated[i], temp.Temperature, proxmoxNodeSMARTTemperatureSource)
log.Debug().
Str("disk", updated[i].DevPath).
Str("serial", updated[i].Serial).
@@ -421,7 +421,7 @@ func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) [
normalizedTempDev := normalizeSMARTDeviceIdentifier(candidate.Device)
return normalizedTempDev != "" && normalizedTempDev == normalizedDevPath
}); temp != nil && temp.Temperature > 0 && !temp.StandbySkipped {
- setPhysicalDiskTemperature(&updated[i], temp.Temperature, "proxmox_node_smart")
+ setPhysicalDiskTemperature(&updated[i], temp.Temperature, proxmoxNodeSMARTTemperatureSource)
log.Debug().
Str("disk", updated[i].DevPath).
Int("temp", temp.Temperature).
@@ -458,7 +458,7 @@ func mergeNVMeTempsIntoDisks(disks []models.PhysicalDisk, nodes []models.Node) [
continue
}
- setPhysicalDiskTemperature(&updated[diskIdx], int(math.Round(tempVal)), "proxmox_node_nvme")
+ setPhysicalDiskTemperature(&updated[diskIdx], int(math.Round(tempVal)), proxmoxNodeNVMeTemperatureSource)
log.Debug().
Str("disk", updated[diskIdx].DevPath).
Int("temp", updated[diskIdx].Temperature).
@@ -486,6 +486,55 @@ func uniqueDiskTemperatureMatch(temperatures []models.DiskTemp, predicate func(m
return &temperatures[matchIndex]
}
+// Collection sources of a disk temperature mergeNVMeTempsIntoDisks took from
+// the node's sensor lists.
+const (
+ proxmoxNodeSMARTTemperatureSource = "proxmox_node_smart"
+ proxmoxNodeNVMeTemperatureSource = "proxmox_node_nvme"
+)
+
+// hostSuppliesNodeSMARTTemperatures reports whether the node's SMART sensor
+// list is this host's report: the node poll takes the linked agent's list when
+// it carries a usable temperature and the SSH collector's otherwise
+// (mergeTemperatureData in host_agent_temps.go). An agent whose lease lapsed
+// supplies nothing, so callers also require it to be reporting.
+func hostSuppliesNodeSMARTTemperatures(host models.Host) bool {
+ for _, row := range host.Sensors.SMART {
+ if row.Temperature > 0 && !row.Standby {
+ return true
+ }
+ }
+ return false
+}
+
+// dropNodeSensorTemperature removes a reading mergeNVMeTempsIntoDisks took
+// from the node's sensor lists, for a disk the operator split from the
+// linked agent's. The SMART list carries rows of the agent's disks when the
+// agent supplies it (smartFromAgent), so a reading from it is the agent's row
+// of the disk this one was split from; an SSH-supplied list is the node's own
+// and stays. The legacy NVMe list names no disk, only an order, so its guess
+// is dropped either way. A reading from another source, which Proxmox itself
+// never supplies, is not touched.
+func dropNodeSensorTemperature(disk *models.PhysicalDisk, smartFromAgent bool) {
+ if disk.Collection == nil {
+ return
+ }
+ switch disk.Collection.Temperature.Source {
+ case proxmoxNodeSMARTTemperatureSource:
+ if !smartFromAgent {
+ return
+ }
+ case proxmoxNodeNVMeTemperatureSource:
+ default:
+ return
+ }
+ disk.Temperature = 0
+ // The copy shares its collection with the caller's slice.
+ collection := diskinventory.CloneStatus(disk.Collection)
+ collection.Temperature = diskinventory.Unsupported("proxmox_disks", "Proxmox disk inventory does not expose temperature")
+ disk.Collection = collection
+}
+
func setPhysicalDiskTemperature(disk *models.PhysicalDisk, temperature int, source string) {
if disk == nil || temperature <= 0 {
return
@@ -497,10 +546,34 @@ func setPhysicalDiskTemperature(disk *models.PhysicalDisk, temperature int, sour
disk.Collection.Temperature = diskinventory.Available(source)
}
+// diskAgentSplitStore is implemented by resource stores that hold the
+// operator's merge exclusions (unifiedresources.MonitorAdapter). It reports
+// whether the operator split a Proxmox disk from the disk a linked host
+// agent reports in one SMART row.
+type diskAgentSplitStore interface {
+ ProxmoxDiskAgentSMARTSplit(disk models.PhysicalDisk, host models.Host, smart models.HostDiskSMART) bool
+}
+
+// proxmoxDiskAgentSplits returns the resource store's split decisions, or nil
+// when the store holds none.
+func (m *Monitor) proxmoxDiskAgentSplits() diskAgentSplitStore {
+ if m == nil {
+ return nil
+ }
+ m.mu.RLock()
+ store := m.resourceStore
+ m.mu.RUnlock()
+ splits, _ := store.(diskAgentSplitStore)
+ return splits
+}
+
// mergeHostAgentSMARTIntoDisks merges SMART temperature data from linked host agents
// into physical disks for Proxmox nodes. This allows disk temps collected by the
-// pulse-agent running on a PVE node to populate the Physical Disks view.
-func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.Node, hosts []models.Host) []models.PhysicalDisk {
+// pulse-agent running on a PVE node to populate the Physical Disks view. A disk
+// the operator split from the agent's disk its matching row describes (splits)
+// takes nothing from that row, nor the node-sensor reading that stands in for
+// it, and is marked AgentSMARTSplit instead.
+func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.Node, hosts []models.Host, splits diskAgentSplitStore) []models.PhysicalDisk {
if len(disks) == 0 || len(nodes) == 0 || len(hosts) == 0 {
return disks
}
@@ -513,6 +586,7 @@ func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.No
// Build a map of node name to linked host's SMART data
smartByNodeName := make(map[string][]models.HostDiskSMART)
+ hostByNodeName := make(map[string]*models.Host)
reportingNodeNames := make(map[string]bool)
for _, node := range nodes {
if node.LinkedAgentID == "" {
@@ -523,6 +597,7 @@ func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.No
continue
}
smartByNodeName[node.Name] = host.Sensors.SMART
+ hostByNodeName[node.Name] = host
// Only an agent still reporting owns its disks' temperature alerts;
// a silent one's retained rows still enrich the disk.
if !strings.EqualFold(strings.TrimSpace(host.Status), "offline") {
@@ -614,6 +689,16 @@ func mergeHostAgentSMARTIntoDisks(disks []models.PhysicalDisk, nodes []models.No
if matched == nil {
continue
}
+ // The operator split this disk from the agent's (report-merge on the
+ // merged disk), so the row describes another disk: its readings,
+ // identity and temperature alert stay the agent's, and the PVE disk
+ // check judges what Proxmox reported. The refusal never pairs another
+ // row, as in the registry's linked disk join.
+ if host := hostByNodeName[updated[i].Node]; splits != nil && splits.ProxmoxDiskAgentSMARTSplit(updated[i], *host, *matched) {
+ updated[i].AgentSMARTSplit = true
+ dropNodeSensorTemperature(&updated[i], reportingNodeNames[updated[i].Node] && hostSuppliesNodeSMARTTemperatures(*host))
+ continue
+ }
// The linked agent reports this disk, so while it keeps reporting its
// CheckHost owns the disk's temperature alert and the PVE disk check
// stands aside. Once its lease lapses, CheckHost no longer alerts on
diff --git a/internal/monitoring/monitor_integration_test.go b/internal/monitoring/monitor_integration_test.go
index db2dd0d5ad..9fec703fc3 100644
--- a/internal/monitoring/monitor_integration_test.go
+++ b/internal/monitoring/monitor_integration_test.go
@@ -13,16 +13,16 @@ import (
func TestMergeHostAgentSMARTIntoDisks_EmptyInputs(t *testing.T) {
// All combinations of empty inputs should return disks unchanged
disks := []models.PhysicalDisk{{ID: "d1"}}
- if got := mergeHostAgentSMARTIntoDisks(nil, nil, nil); got != nil {
+ if got := mergeHostAgentSMARTIntoDisks(nil, nil, nil, nil); got != nil {
t.Error("nil disks should return nil")
}
- if got := mergeHostAgentSMARTIntoDisks(disks, nil, nil); len(got) != 1 {
+ if got := mergeHostAgentSMARTIntoDisks(disks, nil, nil, nil); len(got) != 1 {
t.Error("nil nodes/hosts should return disks unchanged")
}
- if got := mergeHostAgentSMARTIntoDisks(disks, []models.Node{}, nil); len(got) != 1 {
+ if got := mergeHostAgentSMARTIntoDisks(disks, []models.Node{}, nil, nil); len(got) != 1 {
t.Error("empty nodes should return disks unchanged")
}
- if got := mergeHostAgentSMARTIntoDisks(disks, []models.Node{{Name: "n1"}}, nil); len(got) != 1 {
+ if got := mergeHostAgentSMARTIntoDisks(disks, []models.Node{{Name: "n1"}}, nil, nil); len(got) != 1 {
t.Error("nil hosts should return disks unchanged")
}
}
@@ -44,7 +44,7 @@ func TestMergeHostAgentSMARTIntoDisks_MatchByWWN(t *testing.T) {
},
},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Temperature != 42 {
t.Errorf("expected temp 42 via WWN match, got %d", result[0].Temperature)
}
@@ -67,7 +67,7 @@ func TestMergeHostAgentSMARTIntoDisks_MatchBySerial(t *testing.T) {
},
},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Temperature != 38 {
t.Errorf("expected temp 38 via serial match (case-insensitive), got %d", result[0].Temperature)
}
@@ -90,7 +90,7 @@ func TestMergeHostAgentSMARTIntoDisks_MatchByDevPath(t *testing.T) {
},
},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Temperature != 35 {
t.Errorf("expected temp 35 via device path match (strip /dev/), got %d", result[0].Temperature)
}
@@ -113,7 +113,7 @@ func TestMergeHostAgentSMARTIntoDisks_SkipsStandby(t *testing.T) {
},
},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Temperature != 0 {
t.Error("standby disk should not have its temperature merged")
}
@@ -139,7 +139,7 @@ func TestMergeHostAgentSMARTIntoDisks_MergesSMARTAttributes(t *testing.T) {
},
},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].SmartAttributes == nil {
t.Fatal("SMART attributes should be merged")
}
@@ -174,7 +174,7 @@ func TestMergeHostAgentSMARTIntoDisks_DerivesWearoutFromSMARTAttributes(t *testi
},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Wearout != 94 {
t.Fatalf("expected wearout derived from PercentageUsed, got %d", result[0].Wearout)
}
@@ -208,7 +208,7 @@ func TestMergeHostAgentSMARTIntoDisks_SMARTFailureAndWearoutOverrideCoarsePVEVal
},
}}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Health != "FAILED" {
t.Fatalf("SMART failure was suppressed by PVE health: %+v", result[0])
}
@@ -227,7 +227,7 @@ func TestMergeHostAgentSMARTIntoDisks_DoesNotReplaceFailureWithPassed(t *testing
},
}}
- if got := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)[0].Health; got != "FAILED" {
+ if got := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)[0].Health; got != "FAILED" {
t.Fatalf("PASSED replaced an existing failure: %q", got)
}
}
@@ -266,7 +266,7 @@ func TestMergeHostAgentSMARTIntoDisks_DuplicateIdentityRequiresUniqueTopology(t
},
}}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Temperature != 47 || result[0].Health != "PASSED" {
t.Fatalf("topology-specific SMART evidence was not selected: %+v", result[0])
}
@@ -274,7 +274,7 @@ func TestMergeHostAgentSMARTIntoDisks_DuplicateIdentityRequiresUniqueTopology(t
disks[0].Controller = ""
disks[0].Target = ""
disks[0].DevPath = "/dev/unknown"
- result = mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result = mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Temperature != 0 || result[0].Health != "UNKNOWN" {
t.Fatalf("ambiguous SMART identity was guessed: %+v", result[0])
}
@@ -298,7 +298,7 @@ func TestMergeHostAgentSMARTIntoDisks_FillsMissingHealthFromHostSMART(t *testing
},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Health != "FAILED" {
t.Fatalf("expected host SMART health to fill unknown disk health, got %q", result[0].Health)
}
@@ -321,7 +321,7 @@ func TestMergeHostAgentSMARTIntoDisks_NoAgentLink(t *testing.T) {
},
},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Temperature != 0 {
t.Error("unlinked nodes should not get host agent temperatures")
}
@@ -344,7 +344,7 @@ func TestMergeHostAgentSMARTIntoDisks_PreservesExistingTemp(t *testing.T) {
},
},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Temperature != 50 {
t.Errorf("existing temperature should be preserved, got %d", result[0].Temperature)
}
@@ -360,7 +360,7 @@ func TestMergeHostAgentSMARTIntoDisks_OriginalUnchanged(t *testing.T) {
SMART: []models.HostDiskSMART{{Serial: "SER1", Temperature: 42}},
}},
}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if disks[0].Temperature != 0 {
t.Error("original disk slice should not be mutated")
}
diff --git a/internal/monitoring/monitor_pve.go b/internal/monitoring/monitor_pve.go
index f563b5276d..25a6d5e1b0 100644
--- a/internal/monitoring/monitor_pve.go
+++ b/internal/monitoring/monitor_pve.go
@@ -911,7 +911,7 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
nodes := nodesForInstanceFromReadState(readState, instanceName)
hosts := hostsFromReadState(readState)
updated := mergeNVMeTempsIntoDisks(existing, nodes)
- updated = mergeHostAgentSMARTIntoDisks(updated, nodes, hosts)
+ updated = mergeHostAgentSMARTIntoDisks(updated, nodes, hosts, m.proxmoxDiskAgentSplits())
m.state.UpdatePhysicalDisks(instanceName, updated)
}
return
@@ -950,6 +950,7 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
nodesFromState := nodesForInstanceFromReadState(readState, inst)
hosts := hostsFromReadState(readState)
existingDisks := physicalDisksForInstanceFromReadState(readState, inst)
+ splits := m.proxmoxDiskAgentSplits()
existingDisksMap := make(map[string]models.PhysicalDisk, len(existingDisks))
for _, disk := range existingDisks {
if disk.Instance == inst {
@@ -976,12 +977,14 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
// Proxmox disk query fails can still populate its physical disks from
// the agent's smartctl view (#1516).
smartByNode := make(map[string][]models.HostDiskSMART)
+ linkedHostByNode := make(map[string]models.Host)
for _, n := range nodesFromState {
if n.LinkedAgentID == "" || n.Instance != inst {
continue
}
linkedNodes[n.Name] = true
if linkedHost, ok := hostByID[n.LinkedAgentID]; ok {
+ linkedHostByNode[n.Name] = linkedHost
if len(linkedHost.DiskExclude) > 0 {
diskExcludeByNode[n.Name] = linkedHost.DiskExclude
}
@@ -1044,7 +1047,7 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
// exceed the API window PVE itself allows for disks/list, so
// without this fallback their Physical Disks view empties
// permanently (#1516).
- if fallback := physicalDisksFromHostAgentSMART(inst, node.Node, smartByNode[node.Node]); len(fallback) > 0 {
+ if fallback := unsplitPhysicalDisksFromHostAgentSMART(inst, node.Node, linkedHostByNode[node.Node], smartByNode[node.Node], splits); len(fallback) > 0 {
polledNodes[node.Node] = true
allDisks = append(allDisks, fallback...)
log.Info().
@@ -1145,8 +1148,14 @@ func (m *Monitor) maybePollPhysicalDisksAsync(
}
allDisks = mergeNVMeTempsIntoDisks(allDisks, nodesFromState)
- allDisks = mergeHostAgentSMARTIntoDisks(allDisks, nodesFromState, hosts)
+ allDisks = mergeHostAgentSMARTIntoDisks(allDisks, nodesFromState, hosts, splits)
for index := range allDisks {
+ // A split disk's earlier record held the agent's readings and
+ // identity until the split; retained, they would never leave it,
+ // and nothing records which retained value Proxmox collected.
+ if allDisks[index].AgentSMARTSplit {
+ continue
+ }
if previous, ok := previousPhysicalDiskEvidence(allDisks[index], existingDisks); ok {
allDisks[index] = preserveUnavailablePhysicalDiskEvidence(allDisks[index], previous)
}
@@ -1289,6 +1298,28 @@ func physicalDisksFromHostAgentSMART(inst, nodeName string, smartEntries []model
return disks
}
+// unsplitPhysicalDisksFromHostAgentSMART is physicalDisksFromHostAgentSMART
+// without the rows the operator split from the Proxmox disk in their slot.
+// Such a row describes the agent's disk, not the slot's, and standing in for
+// it would copy the agent's disk, readings and temperature alert included,
+// into a second row that the PVE disk check alerts on as well. The stand-in
+// is judged under its own ID, the key the registry holds it by once it is
+// recorded.
+func unsplitPhysicalDisksFromHostAgentSMART(inst, nodeName string, host models.Host, smartEntries []models.HostDiskSMART, splits diskAgentSplitStore) []models.PhysicalDisk {
+ if splits == nil {
+ return physicalDisksFromHostAgentSMART(inst, nodeName, smartEntries)
+ }
+ var disks []models.PhysicalDisk
+ for _, smart := range smartEntries {
+ for _, disk := range physicalDisksFromHostAgentSMART(inst, nodeName, []models.HostDiskSMART{smart}) {
+ if !splits.ProxmoxDiskAgentSMARTSplit(disk, host, smart) {
+ disks = append(disks, disk)
+ }
+ }
+ }
+ return disks
+}
+
func cloneDiskIO(in *models.DiskIO) *models.DiskIO {
if in == nil {
return nil
diff --git a/internal/monitoring/physical_disk_roundtrip_test.go b/internal/monitoring/physical_disk_roundtrip_test.go
index 41a48e0bf6..285dcd3eab 100644
--- a/internal/monitoring/physical_disk_roundtrip_test.go
+++ b/internal/monitoring/physical_disk_roundtrip_test.go
@@ -3,6 +3,8 @@ package monitoring
import (
"context"
"encoding/json"
+ "errors"
+ "slices"
"strconv"
"sync"
"testing"
@@ -293,7 +295,7 @@ func TestMergeHostAgentSMARTIntoDisks_AgentWearoutDoesNotHideLowPVELife(t *testi
},
}}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Wearout != 0 {
t.Fatalf("agent endurance reading raised the remaining life of a worn disk: wearout=%d", result[0].Wearout)
}
@@ -327,7 +329,7 @@ func TestMergeHostAgentSMARTIntoDisks_AgentWearoutFillsUnreportedPVELife(t *test
},
}}
- result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ result := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
if result[0].Wearout != 60 {
t.Fatalf("agent endurance did not fill unreported PVE life: wearout=%d", result[0].Wearout)
}
@@ -535,7 +537,7 @@ func TestMergeHostAgentSMARTIntoDisks_LegacyAgentTemperatureFollowsLease(t *test
Device: "/dev/sdb", Serial: "LEGACY1", Temperature: 38,
}}}})
- reporting := mergeHostAgentSMARTIntoDisks([]models.PhysicalDisk{proxmoxDisk}, nodes, state.GetHosts())[0]
+ reporting := mergeHostAgentSMARTIntoDisks([]models.PhysicalDisk{proxmoxDisk}, nodes, state.GetHosts(), nil)[0]
if reporting.Temperature != 38 || reporting.Collection.Temperature != diskinventory.Available(diskinventory.LegacyHostAgentSource) {
t.Fatalf("legacy agent temperature not recorded as collected: temp=%d collection=%+v", reporting.Temperature, reporting.Collection)
}
@@ -548,7 +550,7 @@ func TestMergeHostAgentSMARTIntoDisks_LegacyAgentTemperatureFollowsLease(t *test
"full poll": proxmoxDisk,
"skipped poll": reporting,
} {
- got := mergeHostAgentSMARTIntoDisks([]models.PhysicalDisk{disk}, nodes, state.GetHosts())[0]
+ got := mergeHostAgentSMARTIntoDisks([]models.PhysicalDisk{disk}, nodes, state.GetHosts(), nil)[0]
if got.Temperature != 38 || got.Collection.Temperature.State != diskinventory.FieldUnavailable {
t.Fatalf("%s: silent legacy agent temperature presented as collected: temp=%d collection=%+v", name, got.Temperature, got.Collection)
}
@@ -591,7 +593,7 @@ func TestSilentLegacyAgentCanonicalDiskFollowsItsWithdrawal(t *testing.T) {
// The disk poll while the agent reported is the copy the Proxmox row
// keeps once its host stops being polled.
state.UpdatePhysicalDisks("pve1", mergeHostAgentSMARTIntoDisks(
- []models.PhysicalDisk{inventory}, state.GetSnapshot().Nodes, state.GetHosts()))
+ []models.PhysicalDisk{inventory}, state.GetSnapshot().Nodes, state.GetHosts(), nil))
canonical := func() (int, *diskinventory.CollectionStatus) {
t.Helper()
adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(nil))
@@ -791,6 +793,7 @@ type slotDiskPVEClient struct {
fakeStorageClient
mu sync.Mutex
disk proxmox.Disk
+ err error
}
func (client *slotDiskPVEClient) setDisk(disk proxmox.Disk) {
@@ -799,9 +802,20 @@ func (client *slotDiskPVEClient) setDisk(disk proxmox.Disk) {
client.disk = disk
}
+// setError makes the disk query fail, as it does on a wide node that exceeds
+// the API window (#1516), until it is cleared with nil.
+func (client *slotDiskPVEClient) setError(err error) {
+ client.mu.Lock()
+ defer client.mu.Unlock()
+ client.err = err
+}
+
func (client *slotDiskPVEClient) GetDisks(context.Context, string) ([]proxmox.Disk, error) {
client.mu.Lock()
defer client.mu.Unlock()
+ if client.err != nil {
+ return nil, client.err
+ }
return []proxmox.Disk{client.disk}, nil
}
@@ -1146,7 +1160,7 @@ func TestMergeHostAgentSMARTIntoDisksMarksDisksTheAgentReports(t *testing.T) {
{ID: "host-node3", Status: "offline", Sensors: models.HostSensorSummary{SMART: smart}},
}
- merged := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts)
+ merged := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, nil)
for i, want := range []bool{true, false, false, false} {
if merged[i].AgentSMARTReported != want {
t.Fatalf("%s/%s AgentSMARTReported = %v, want %v", merged[i].Node, merged[i].DevPath, merged[i].AgentSMARTReported, want)
@@ -1159,7 +1173,7 @@ func TestMergeHostAgentSMARTIntoDisksMarksDisksTheAgentReports(t *testing.T) {
t.Fatalf("a silent agent's retained row no longer enriches the disk: %+v", merged[3])
}
- fallback := mergeHostAgentSMARTIntoDisks(physicalDisksFromHostAgentSMART("pve1", "node1", smart), nodes, hosts)
+ fallback := mergeHostAgentSMARTIntoDisks(physicalDisksFromHostAgentSMART("pve1", "node1", smart), nodes, hosts, nil)
if len(fallback) != 1 || !fallback[0].AgentSMARTReported {
t.Fatalf("a disk built from a reporting agent's SMART report is not the agent's: %+v", fallback)
}
@@ -1215,3 +1229,740 @@ func TestCheckPhysicalDiskAlertsRaisesProxmoxDiskTemperatureAlerts(t *testing.T)
t.Fatalf("an excluded device raised a temperature alert")
}
}
+
+// An operator split of a Proxmox disk from the disk its linked agent reports
+// (report-merge on the merged disk, the drawer's Split merged resource) holds
+// for the PVE disk poller too. The poller paired the agent's SMART row with the
+// Proxmox disk by WWN, serial or path before the registry saw either, and read
+// no exclusions, so the registry kept two rows while the Proxmox record still
+// carried the agent's attributes, I/O, health, serial, type and temperature,
+// and the agent kept the disk's temperature alert (AgentSMARTReported). A split
+// row carries what Proxmox reported, whatever an earlier poll merged into it,
+// on a full poll and on the skipped polls between. That includes the
+// temperature: a node with a linked agent takes its sensor lists from the
+// agent, so the reading the node poll matches to the disk is the agent's row
+// of the disk it was split from, and the disk neither shows it nor alerts on it
+// a second time beside the agent's own alert.
+func TestOperatorSplitKeepsAgentSMARTOffTheProxmoxDisk(t *testing.T) {
+ percentUsed, hours := 40, int64(1200)
+ agentSMART := func(device, model, serial, diskType string, temperature int) models.HostDiskSMART {
+ return models.HostDiskSMART{
+ Device: device, Model: model, Serial: serial, Type: diskType, Health: "FAILED", Temperature: temperature,
+ IO: &models.DiskIO{Device: device, ReadBytes: 4096, WriteBytes: 8192},
+ Attributes: &models.SMARTAttributes{PowerOnHours: &hours, PercentageUsed: &percentUsed},
+ Collection: &diskinventory.CollectionStatus{
+ Serial: diskinventory.Available("smartctl"),
+ Temperature: diskinventory.Available("smartctl"),
+ IO: diskinventory.Available("kernel_diskstats"),
+ },
+ }
+ }
+ for _, shape := range []struct {
+ name string
+ agent models.HostDiskSMART
+ pve proxmox.Disk
+ // nodeTemp is the node sensor list's row for the disk. The node poll
+ // takes that list from the linked agent, so it is the agent's reading.
+ nodeTemp *models.DiskTemp
+ // What a paired record carries: the agent's serial and type, and the
+ // temperature it reports unless the node's sensors read the disk.
+ pairedSerial, pairedType string
+ pairedTemperature int
+ // The temperature a skipped poll reads back from the joined canonical
+ // disk, and what the split disk shows once the agent's reading is gone.
+ skippedTemperature, splitTemperature int
+ // Whether the PVE disk check alerts on the split disk's reading.
+ splitAlert bool
+ }{
+ // Proxmox reports the SAS transport address as the serial (#1595), so
+ // only the device path pairs the rows, and the pairing promotes the
+ // agent's serial and transport over Proxmox's.
+ {
+ name: "sas-path",
+ agent: agentSMART("/dev/sda", "ST4000NM0023", "Z1Z0ABCD", "sas", 70),
+ pve: proxmox.Disk{DevPath: "/dev/sda", Model: "ST4000NM0023", Serial: "5000c500a1b2c3d4", Type: "hdd",
+ Health: "PASSED", Wearout: 100, Size: 4000787030016},
+ pairedSerial: "Z1Z0ABCD", pairedType: "sas", pairedTemperature: 70, skippedTemperature: 70,
+ },
+ // One serial on both sides, and the node's sensor list reads the disk,
+ // so it carries a reading and can raise a temperature alert.
+ {
+ name: "matching-serial",
+ agent: agentSMART("/dev/nvme0n1", "WD Black SN850X", "S6B0NL0W123456", "nvme", 40),
+ pve: proxmox.Disk{DevPath: "/dev/nvme0n1", Model: "WD Black SN850X", Serial: "S6B0NL0W123456", Type: "nvme",
+ Health: "PASSED", Wearout: 100, Size: 1000204886016},
+ nodeTemp: &models.DiskTemp{Device: "/dev/nvme0n1", Serial: "S6B0NL0W123456", Type: "nvme", Temperature: 85},
+ pairedSerial: "S6B0NL0W123456", pairedType: "nvme", pairedTemperature: 85, skippedTemperature: 40,
+ },
+ // The agent's report carries no usable temperature, so the node's SMART
+ // list is the SSH collector's: the reading is the node's own, survives the
+ // split, and the PVE disk check, no longer deferring to the agent, alerts.
+ {
+ name: "ssh-sensors",
+ agent: agentSMART("/dev/nvme1n1", "WD Black SN770", "S7SSH0000001", "nvme", 0),
+ pve: proxmox.Disk{DevPath: "/dev/nvme1n1", Model: "WD Black SN770", Serial: "S7SSH0000001", Type: "nvme",
+ Health: "PASSED", Wearout: 100, Size: 1000204886016},
+ nodeTemp: &models.DiskTemp{Device: "/dev/nvme1n1", Serial: "S7SSH0000001", Type: "nvme", Temperature: 85},
+ pairedSerial: "S7SSH0000001", pairedType: "nvme", pairedTemperature: 85, skippedTemperature: 85,
+ splitTemperature: 85, splitAlert: true,
+ },
+ } {
+ for _, request := range []struct {
+ name string
+ // exclusions are the pairs report-merge records for the merged disk.
+ exclusions func(merged, agentCandidate, proxmoxCandidate string) [][2]string
+ split bool
+ }{
+ {"report-merge", func(merged, agent, proxmox string) [][2]string {
+ return [][2]string{{merged, agent}, {merged, proxmox}}
+ }, true},
+ {"proxmox-candidate-only", func(merged, _, proxmox string) [][2]string {
+ return [][2]string{{merged, proxmox}}
+ }, true},
+ // The agent's row holds the merged ID, so a pair naming only its
+ // candidate separates nothing, here as in the registry.
+ {"agent-candidate-only", func(merged, agent, _ string) [][2]string {
+ return [][2]string{{merged, agent}}
+ }, false},
+ {"unrelated-exclusion", func(merged, _, _ string) [][2]string {
+ return [][2]string{{merged, "physical_disk-00000000deadbeef"}}
+ }, false},
+ } {
+ t.Run(shape.name+"/"+request.name, func(t *testing.T) {
+ t.Setenv("PULSE_DATA_DIR", t.TempDir())
+ now := time.Now()
+ const instance, nodeName = "pve1", "node1"
+ node := models.Node{
+ ID: "pve1-node1", Name: nodeName, Instance: instance, Host: "https://10.0.0.5:8006",
+ Status: "online", LastSeen: now, LinkedAgentID: "agent-1",
+ }
+ if shape.nodeTemp != nil {
+ reading := *shape.nodeTemp
+ reading.LastUpdated = now
+ node.Temperature = &models.Temperature{Available: true, HasSMART: true, SMART: []models.DiskTemp{reading}, LastUpdate: now}
+ }
+ state := models.NewState()
+ state.UpdateNodesForInstance(instance, []models.Node{node})
+ state.UpsertHost(models.Host{
+ ID: "agent-1", Hostname: nodeName, MachineID: "0123456789abcdef", LinkedNodeID: node.ID,
+ Status: "online", IntervalSeconds: 30, LastSeen: now,
+ Sensors: models.HostSensorSummary{SMART: []models.HostDiskSMART{shape.agent}},
+ })
+ store, err := unifiedresources.NewSQLiteResourceStore(t.TempDir(), "default")
+ if err != nil {
+ t.Fatal(err)
+ }
+ t.Cleanup(func() { _ = store.Close() })
+ alertManager := alerts.NewManager()
+ t.Cleanup(alertManager.Stop)
+ adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(store))
+ m := &Monitor{
+ state: state, resourceStore: adapter, alertManager: alertManager,
+ metricsHistory: NewMetricsHistory(100, time.Hour),
+ startTime: now.Add(-time.Hour), lastPhysicalDiskPoll: make(map[string]time.Time),
+ }
+ client := &slotDiskPVEClient{}
+ client.setDisk(shape.pve)
+
+ disk := func() models.PhysicalDisk {
+ t.Helper()
+ disks := state.GetSnapshot().PhysicalDisks
+ if len(disks) != 1 {
+ t.Fatalf("physical disks = %+v, want one", disks)
+ }
+ return disks[0]
+ }
+ fullPoll := func() models.PhysicalDisk {
+ t.Helper()
+ adapter.PopulateFromSnapshot(state.GetSnapshot())
+ started := time.Now()
+ delete(m.lastPhysicalDiskPoll, instance)
+ m.maybePollPhysicalDisksAsync(context.Background(), instance, &config.PVEInstance{}, client,
+ []proxmox.Node{{Node: nodeName, Status: "online"}}, map[string]string{nodeName: "online"}, nil)
+ deadline := time.Now().Add(3 * time.Second)
+ for {
+ if disks := state.GetSnapshot().PhysicalDisks; len(disks) == 1 && !disks[0].LastChecked.Before(started) {
+ return disks[0]
+ }
+ if time.Now().After(deadline) {
+ t.Fatal("full physical disk poll did not land in state")
+ }
+ time.Sleep(10 * time.Millisecond)
+ }
+ }
+ skippedPoll := func() models.PhysicalDisk {
+ t.Helper()
+ adapter.PopulateFromSnapshot(state.GetSnapshot())
+ m.lastPhysicalDiskPoll[instance] = time.Now()
+ m.maybePollPhysicalDisksAsync(context.Background(), instance, &config.PVEInstance{}, nil, nil, nil, nil)
+ return disk()
+ }
+ temperatureAlert := func() bool {
+ id := unifiedresources.ProxmoxPhysicalDiskAlertResourceID(instance, nodeName, shape.pve.DevPath) + "::metric-threshold:diskTemperature"
+ for _, alert := range alertManager.GetActiveAlerts() {
+ if alert.ID == id {
+ return true
+ }
+ }
+ return false
+ }
+ healthAlert := func() bool {
+ for _, alert := range alertManager.GetActiveAlerts() {
+ if alert.Type == "disk-health" {
+ return true
+ }
+ }
+ return false
+ }
+ // A poll whose Proxmox disk query fails carries the stored record
+ // (or the agent's rows) instead of a fresh one, so it is done when
+ // the state is written rather than when a disk is newly checked.
+ failedQueryPoll := func() models.PhysicalDisk {
+ t.Helper()
+ adapter.PopulateFromSnapshot(state.GetSnapshot())
+ client.setError(errors.New("disks/list timed out"))
+ defer client.setError(nil)
+ started := time.Now()
+ delete(m.lastPhysicalDiskPoll, instance)
+ m.maybePollPhysicalDisksAsync(context.Background(), instance, &config.PVEInstance{}, client,
+ []proxmox.Node{{Node: nodeName, Status: "online"}}, map[string]string{nodeName: "online"}, nil)
+ deadline := time.Now().Add(3 * time.Second)
+ for {
+ if snapshot := state.GetSnapshot(); snapshot.LastUpdate.After(started) && len(snapshot.PhysicalDisks) == 1 {
+ return snapshot.PhysicalDisks[0]
+ }
+ if time.Now().After(deadline) {
+ t.Fatal("physical disk poll with a failing disk query did not land in state")
+ }
+ time.Sleep(10 * time.Millisecond)
+ }
+ }
+ // Whether the canonical disks are one joined row or two.
+ canonicalRows := func() (joined, agentOnly, proxmoxOnly []*unifiedresources.PhysicalDiskView) {
+ t.Helper()
+ adapter.PopulateFromSnapshot(state.GetSnapshot())
+ for _, view := range adapter.PhysicalDisks() {
+ _, fromAgent := view.SourceStatus(unifiedresources.SourceAgent)
+ _, fromProxmox := view.SourceStatus(unifiedresources.SourceProxmox)
+ switch {
+ case fromAgent && fromProxmox:
+ joined = append(joined, view)
+ case fromAgent:
+ agentOnly = append(agentOnly, view)
+ case fromProxmox:
+ proxmoxOnly = append(proxmoxOnly, view)
+ }
+ }
+ return joined, agentOnly, proxmoxOnly
+ }
+
+ assertPaired := func(step string, got models.PhysicalDisk, wantTemperature int) {
+ t.Helper()
+ if got.Serial != shape.pairedSerial || got.Type != shape.pairedType || got.Health != "FAILED" ||
+ got.Temperature != wantTemperature || got.Wearout != 60 ||
+ got.SmartAttributes == nil || got.IO == nil || !got.AgentSMARTReported || got.AgentSMARTSplit {
+ t.Fatalf("%s: the agent's row was not paired with the Proxmox disk: %+v", step, got)
+ }
+ }
+ assertProxmoxOnly := func(step string, got models.PhysicalDisk) {
+ t.Helper()
+ if got.Serial != shape.pve.Serial || got.Type != shape.pve.Type || got.Health != "PASSED" ||
+ got.Temperature != shape.splitTemperature || got.Wearout != shape.pve.Wearout ||
+ got.SmartAttributes != nil || got.IO != nil || got.AgentSMARTReported || !got.AgentSMARTSplit {
+ t.Fatalf("%s: the split disk carries the agent's data: %+v", step, got)
+ }
+ }
+
+ // The disk's temperature alert is open before the agent's row
+ // is paired with it, as when the node's sensors read it alone.
+ // A shape whose alert should open after the split starts without
+ // one: the alert manager suppresses an alert it just resolved.
+ if shape.nodeTemp != nil && !shape.splitAlert {
+ m.checkPhysicalDiskAlerts(instance, models.PhysicalDisk{
+ Instance: instance, Node: nodeName, DevPath: shape.pve.DevPath, Model: shape.pve.Model,
+ Type: shape.pve.Type, Health: "PASSED", Wearout: -1, Temperature: shape.nodeTemp.Temperature,
+ }, nil)
+ if !temperatureAlert() {
+ t.Fatal("fixture did not open the Proxmox disk's temperature alert")
+ }
+ }
+ assertPaired("before the request", fullPoll(), shape.pairedTemperature)
+ if !healthAlert() {
+ t.Fatal("the agent's failed health did not raise the disk health alert")
+ }
+ if joined, agentOnly, proxmoxOnly := canonicalRows(); len(joined) != 1 || len(agentOnly) != 0 || len(proxmoxOnly) != 0 {
+ t.Fatalf("fixture did not join the disks: joined %d, agent only %d, proxmox only %d", len(joined), len(agentOnly), len(proxmoxOnly))
+ }
+ if temperatureAlert() {
+ t.Fatal("the PVE disk's temperature alert stayed open for a disk the agent reports")
+ }
+
+ // Report-merge names the merged disk and each source's candidate.
+ ids := unifiedresources.NewRegistry(nil)
+ ids.IngestSnapshot(state.GetSnapshot())
+ var merged, agentCandidate, proxmoxCandidate string
+ for _, resource := range ids.List() {
+ if resource.Type == unifiedresources.ResourceTypePhysicalDisk {
+ merged = resource.ID
+ }
+ }
+ for _, target := range ids.SourceTargets(merged) {
+ switch target.Source {
+ case unifiedresources.SourceAgent:
+ agentCandidate = target.CandidateID
+ case unifiedresources.SourceProxmox:
+ proxmoxCandidate = target.CandidateID
+ }
+ }
+ if merged == "" || agentCandidate == "" || proxmoxCandidate == "" || proxmoxCandidate == merged {
+ t.Fatalf("merged disk %q lists candidates agent=%q proxmox=%q", merged, agentCandidate, proxmoxCandidate)
+ }
+ for _, pair := range request.exclusions(merged, agentCandidate, proxmoxCandidate) {
+ if err := store.AddExclusion(unifiedresources.ResourceExclusion{ResourceA: pair[0], ResourceB: pair[1], CreatedAt: time.Now().UTC()}); err != nil {
+ t.Fatal(err)
+ }
+ }
+
+ if !request.split {
+ assertPaired("after the request", fullPoll(), shape.pairedTemperature)
+ // A skipped poll merges the stored record, which the joined
+ // canonical disk reports at the agent's reading.
+ assertPaired("on a skipped poll", skippedPoll(), shape.skippedTemperature)
+ return
+ }
+ // A full poll builds the record from what Proxmox reported,
+ // and the poll after it must not retain what the one before
+ // held from the agent. The skipped polls between, which merge
+ // the stored record again, keep the agent's data off too.
+ assertProxmoxOnly("after the request", fullPoll())
+ // The split disk is still evaluated, and Proxmox's own verdict
+ // of it closes the health alert the agent's failure raised.
+ if healthAlert() {
+ t.Fatal("the disk health alert raised by the agent's row stayed open on the split disk")
+ }
+ assertProxmoxOnly("on a skipped poll", skippedPoll())
+ assertProxmoxOnly("on the next full poll", fullPoll())
+ assertProxmoxOnly("on the next skipped poll", skippedPoll())
+ // When Proxmox cannot list the node's disks, the agent's rows
+ // stand in for them (#1516), except the row split from the
+ // disk in its slot.
+ assertProxmoxOnly("when the disk query fails", failedQueryPoll())
+
+ joined, agentOnly, proxmoxOnly := canonicalRows()
+ if len(joined) != 0 || len(agentOnly) != 1 || len(proxmoxOnly) != 1 {
+ t.Fatalf("canonical disks: joined %d, agent only %d, proxmox only %d, want the two apart", len(joined), len(agentOnly), len(proxmoxOnly))
+ }
+ if proxmoxOnly[0].Health() != "PASSED" || proxmoxOnly[0].Serial() != shape.pve.Serial {
+ t.Fatalf("canonical Proxmox disk took the agent's data: health %q, serial %q", proxmoxOnly[0].Health(), proxmoxOnly[0].Serial())
+ }
+ if agentOnly[0].Health() != "FAILED" || agentOnly[0].Serial() != shape.agent.Serial {
+ t.Fatalf("canonical agent disk lost its own data: health %q, serial %q", agentOnly[0].Health(), agentOnly[0].Serial())
+ }
+ // A reading the agent supplied is gone, so the PVE disk check has
+ // none to judge and the alert the agent took over does not come
+ // back; one the SSH collector supplied is judged by the PVE check.
+ if temperatureAlert() != shape.splitAlert {
+ t.Fatalf("PVE temperature alert active = %v, want %v once the disks were split", temperatureAlert(), shape.splitAlert)
+ }
+ })
+ }
+ }
+}
+
+// fakeDiskAgentSplits answers the PVE disk poller's split question from a
+// set of Proxmox device paths and records what it was asked.
+type fakeDiskAgentSplits struct {
+ splitDevPaths map[string]bool
+ splitIDs map[string]bool
+ asked []string
+ askedIDs []string
+}
+
+func (f *fakeDiskAgentSplits) ProxmoxDiskAgentSMARTSplit(disk models.PhysicalDisk, host models.Host, smart models.HostDiskSMART) bool {
+ f.asked = append(f.asked, host.ID+":"+disk.DevPath+":"+smart.Serial)
+ f.askedIDs = append(f.askedIDs, disk.ID)
+ return f.splitDevPaths[disk.DevPath] || f.splitIDs[disk.ID]
+}
+
+// The agent's SMART merge asks the split decider once per disk it matches a
+// row to. A split disk takes nothing from the row, not even the alert
+// ownership, and is marked so the poll does not retain the agent's data for it
+// either; a disk no row matches is not asked about; the rows of the disks that
+// are not split still merge, as they do without a decider.
+func TestMergeHostAgentSMARTIntoDisksLeavesDisksTheOperatorSplitAlone(t *testing.T) {
+ percentUsed := 40
+ smart := func(device, serial string) models.HostDiskSMART {
+ return models.HostDiskSMART{
+ Device: device, Serial: serial, Type: "sata", Health: "FAILED", Temperature: 61,
+ WWN: "5-c50-" + serial, Controller: "ctrl", Target: "0:1", Pool: "tank", Model: "AgentModel", SizeBytes: 1000,
+ IO: &models.DiskIO{Device: device, ReadBytes: 1},
+ Attributes: &models.SMARTAttributes{PercentageUsed: &percentUsed},
+ }
+ }
+ disk := func(devPath, serial string) models.PhysicalDisk {
+ return models.PhysicalDisk{ID: unifiedresources.ProxmoxPhysicalDiskSourceID("pve1", "node1", devPath, "", ""), Node: "node1", Instance: "pve1", DevPath: devPath, Serial: serial, Type: "sata", Health: "PASSED", Wearout: 100}
+ }
+ nodes := []models.Node{{Name: "node1", LinkedAgentID: "agent-1"}}
+ hosts := []models.Host{{ID: "agent-1", Status: "online", Sensors: models.HostSensorSummary{
+ SMART: []models.HostDiskSMART{smart("sda", "SERIAL-A"), smart("sdb", "SERIAL-B")},
+ }}}
+ disks := []models.PhysicalDisk{disk("/dev/sda", "SERIAL-A"), disk("/dev/sdb", "SERIAL-B"), disk("/dev/sdc", "SERIAL-C")}
+ // The node's sensor list, which a linked agent supplies, was matched to the
+ // split disk before the agent merge ran.
+ disks[0].Temperature = 58
+ disks[0].Collection = &diskinventory.CollectionStatus{Temperature: diskinventory.Available(proxmoxNodeSMARTTemperatureSource)}
+ // Proxmox's own verdict of the split disk, which the agent's PASSED/FAILED
+ // would otherwise replace or correct.
+ disks[0].Health, disks[0].Wearout = "FAILED", 30
+
+ splits := &fakeDiskAgentSplits{splitDevPaths: map[string]bool{"/dev/sda": true, "/dev/sdc": true}}
+ merged := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, splits)
+
+ wantSplit := disk("/dev/sda", "SERIAL-A")
+ wantSplit.AgentSMARTSplit = true
+ if got := merged[0]; got.Temperature != 0 || got.Health != "FAILED" || got.Wearout != 30 || got.SmartAttributes != nil || got.IO != nil ||
+ got.AgentSMARTReported || !got.AgentSMARTSplit || got.ID != wantSplit.ID || got.Serial != wantSplit.Serial ||
+ got.WWN != "" || got.Controller != "" || got.Target != "" || got.StorageGroup != "" || got.Model != "" || got.Size != 0 {
+ t.Fatalf("a split disk took the agent's row: %+v", got)
+ }
+ if got := merged[1]; got.Temperature != 61 || got.Health != "FAILED" || got.Wearout != 60 || got.SmartAttributes == nil || got.IO == nil ||
+ !got.AgentSMARTReported || got.AgentSMARTSplit {
+ t.Fatalf("a disk that is not split lost the agent's row: %+v", got)
+ }
+ if got := merged[2]; got.AgentSMARTSplit || got.AgentSMARTReported {
+ t.Fatalf("a disk no row matches was marked: %+v", got)
+ }
+ if want := []string{"agent-1:/dev/sda:SERIAL-A", "agent-1:/dev/sdb:SERIAL-B"}; !slices.Equal(splits.asked, want) {
+ t.Fatalf("decider asked %v, want one question per matched disk %v", splits.asked, want)
+ }
+ if disks[0].AgentSMARTSplit || disks[0].Temperature != 58 || disks[0].Collection.Temperature.State != diskinventory.FieldAvailable {
+ t.Fatalf("the merge modified the caller's slice: %+v / %+v", disks[0], disks[0].Collection)
+ }
+ if merged[0].Collection == nil || merged[0].Collection.Temperature.State == diskinventory.FieldAvailable {
+ t.Fatalf("the split disk still counts the node sensors' reading as collected: %+v", merged[0].Collection)
+ }
+
+ // The decision is made under the observation's own ID, the key the registry
+ // holds it by: a controller member recorded by device alone is a different
+ // observation from the stand-in keyed by its target, so a split recorded
+ // under the other key is ignored, as it is for the registry.
+ memberRow := smart("sdd", "SERIAL-D")
+ memberRow.Controller, memberRow.Target = "megaraid", "megaraid,7"
+ memberHosts := []models.Host{{ID: "agent-1", Status: "online", Sensors: models.HostSensorSummary{SMART: []models.HostDiskSMART{memberRow}}}}
+ slotID := unifiedresources.ProxmoxPhysicalDiskSourceID("pve1", "node1", "/dev/sdd", "", "")
+ memberID := unifiedresources.ProxmoxPhysicalDiskSourceID("pve1", "node1", "/dev/sdd", "megaraid", "megaraid,7")
+ if slotID == memberID {
+ t.Fatal("fixture: a controller member's key should differ from the slot's")
+ }
+ bySlot := disk("/dev/sdd", "SERIAL-D")
+ byMember := bySlot
+ byMember.ID = memberID
+ for name, tc := range map[string]struct {
+ disk models.PhysicalDisk
+ splitID string
+ wantSplit bool
+ wantAsked string
+ }{
+ "slot-keyed record, split under its key": {bySlot, slotID, true, slotID},
+ "slot-keyed record, split under member key": {bySlot, memberID, false, slotID},
+ "member-keyed record, split under its key": {byMember, memberID, true, memberID},
+ "member-keyed record, split under slot key": {byMember, slotID, false, memberID},
+ } {
+ decider := &fakeDiskAgentSplits{splitIDs: map[string]bool{tc.splitID: true}}
+ got := mergeHostAgentSMARTIntoDisks([]models.PhysicalDisk{tc.disk}, nodes, memberHosts, decider)[0]
+ if got.AgentSMARTSplit != tc.wantSplit || got.AgentSMARTReported == tc.wantSplit {
+ t.Fatalf("%s: split = %v, reported = %v, want split %v", name, got.AgentSMARTSplit, got.AgentSMARTReported, tc.wantSplit)
+ }
+ if !slices.Equal(decider.askedIDs, []string{tc.wantAsked}) {
+ t.Fatalf("%s: decider asked about %v, want exactly the record's own ID %q", name, decider.askedIDs, tc.wantAsked)
+ }
+ }
+
+ // The node-sensor reading already on the disk stays; the agent's fills only an empty one.
+ if unchanged := mergeHostAgentSMARTIntoDisks(disks, nodes, hosts, &fakeDiskAgentSplits{}); !unchanged[0].AgentSMARTReported || unchanged[0].Temperature != 58 || unchanged[0].Health != "FAILED" {
+ t.Fatalf("a decider that splits nothing changed the merge: %+v", unchanged[0])
+ }
+}
+
+// When the Proxmox disk query fails, the linked agent's SMART rows stand in
+// for the node's disks (#1516). A row the operator split from the Proxmox disk
+// in its slot is not that disk's stand-in: it would put the agent's disk, with
+// its readings and temperature alert, in a second row beside the agent's own.
+// The stand-in is judged under its own ID, the key the registry holds it by
+// once recorded: a controller member's is qualified by its target.
+func TestHostAgentSMARTFallbackSkipsRowsTheOperatorSplit(t *testing.T) {
+ rows := []models.HostDiskSMART{
+ {Device: "sda", Serial: "SERIAL-A", Type: "sata", Temperature: 61},
+ {Device: "sdb", Serial: "SERIAL-B", Type: "sata", Temperature: 62},
+ }
+ host := models.Host{ID: "agent-1"}
+
+ if got := unsplitPhysicalDisksFromHostAgentSMART("pve1", "node1", host, rows, nil); len(got) != 2 {
+ t.Fatalf("without split decisions the fallback listed %d disks, want 2", len(got))
+ }
+ if got := unsplitPhysicalDisksFromHostAgentSMART("pve1", "node1", host, rows, &fakeDiskAgentSplits{}); len(got) != 2 {
+ t.Fatalf("a decider that splits nothing left %d stand-ins, want 2", len(got))
+ }
+ splits := &fakeDiskAgentSplits{splitDevPaths: map[string]bool{"/dev/sda": true}}
+ got := unsplitPhysicalDisksFromHostAgentSMART("pve1", "node1", host, rows, splits)
+ if len(got) != 1 || got[0].DevPath != "/dev/sdb" || got[0].Temperature != 62 {
+ t.Fatalf("fallback disks = %+v, want only /dev/sdb", got)
+ }
+ if want := []string{"agent-1:/dev/sda:SERIAL-A", "agent-1:/dev/sdb:SERIAL-B"}; !slices.Equal(splits.asked, want) {
+ t.Fatalf("decider asked %v, want one question per row, with the row %v", splits.asked, want)
+ }
+
+ member := []models.HostDiskSMART{{Device: "sdc", Serial: "SERIAL-C", Type: "sat", Controller: "megaraid", Target: "megaraid,7"}}
+ stand := physicalDisksFromHostAgentSMART("pve1", "node1", member)
+ slot := unifiedresources.ProxmoxPhysicalDiskSourceID("pve1", "node1", "/dev/sdc", "", "")
+ if len(stand) != 1 || stand[0].ID == slot {
+ t.Fatalf("a controller member's stand-in should be keyed by its target: %+v", stand)
+ }
+ byOwnID := &fakeDiskAgentSplits{splitIDs: map[string]bool{stand[0].ID: true}}
+ if got := unsplitPhysicalDisksFromHostAgentSMART("pve1", "node1", host, member, byOwnID); len(got) != 0 {
+ t.Fatalf("a split recorded under the stand-in's key did not hold: %+v", got)
+ }
+ if want := []string{stand[0].ID}; !slices.Equal(byOwnID.askedIDs, want) {
+ t.Fatalf("decider asked about %v, want the stand-in's own ID %v", byOwnID.askedIDs, want)
+ }
+ // A split recorded under the slot's device-only key names a different
+ // observation, as for the registry: the stand-in is not that disk.
+ bySlot := &fakeDiskAgentSplits{splitIDs: map[string]bool{slot: true}}
+ if got := unsplitPhysicalDisksFromHostAgentSMART("pve1", "node1", host, member, bySlot); len(got) != 1 {
+ t.Fatalf("a split recorded under the slot's key applied to the member's stand-in: %+v", got)
+ }
+ if want := []string{stand[0].ID}; !slices.Equal(bySlot.askedIDs, want) {
+ t.Fatalf("decider asked about %v, want only the stand-in's own ID %v", bySlot.askedIDs, want)
+ }
+}
+
+// When the Proxmox disk query fails and the operator split one of the node's
+// disks from its agent row, only the rows that were not split stand in for the
+// node's disks, as before; the split disk gets no stand-in, which would be the
+// agent's disk again, so its Proxmox record is not listed while the query fails.
+func TestFailedDiskQueryListsOnlyTheRowsTheOperatorDidNotSplit(t *testing.T) {
+ t.Setenv("PULSE_DATA_DIR", t.TempDir())
+ now := time.Now()
+ state := models.NewState()
+ state.UpdateNodesForInstance("pve1", []models.Node{{
+ ID: "pve1-node1", Name: "node1", Instance: "pve1", Status: "online", LastSeen: now, LinkedAgentID: "agent-1",
+ }})
+ state.UpsertHost(models.Host{
+ ID: "agent-1", Hostname: "node1", LinkedNodeID: "pve1-node1", Status: "online", IntervalSeconds: 30, LastSeen: now,
+ Sensors: models.HostSensorSummary{SMART: []models.HostDiskSMART{
+ {Device: "/dev/sda", Serial: "AGENT-A", Type: "sata", Health: "FAILED", Temperature: 61},
+ {Device: "/dev/sdb", Serial: "SERIAL-B", Type: "sata", Health: "PASSED", Temperature: 62},
+ }},
+ })
+ record := func(device, serial string) models.PhysicalDisk {
+ return models.PhysicalDisk{
+ ID: unifiedresources.ProxmoxPhysicalDiskSourceID("pve1", "node1", device, "", ""), Node: "node1", Instance: "pve1",
+ DevPath: device, Serial: serial, Type: "sata", Health: "PASSED", Wearout: 100, LastChecked: now,
+ Collection: &diskinventory.CollectionStatus{Temperature: diskinventory.Unsupported("proxmox_disks", "no temperature")},
+ }
+ }
+ state.UpdatePhysicalDisks("pve1", []models.PhysicalDisk{record("/dev/sda", "PVE-A"), record("/dev/sdb", "SERIAL-B")})
+
+ alertManager := alerts.NewManager()
+ t.Cleanup(alertManager.Stop)
+ adapter := unifiedresources.NewMonitorAdapter(unifiedresources.NewRegistry(nil))
+ m := &Monitor{
+ state: state,
+ resourceStore: splitDecidingStore{adapter, &fakeDiskAgentSplits{splitDevPaths: map[string]bool{"/dev/sda": true}}},
+ alertManager: alertManager, metricsHistory: NewMetricsHistory(100, time.Hour),
+ startTime: now.Add(-time.Hour), lastPhysicalDiskPoll: make(map[string]time.Time),
+ }
+ adapter.PopulateFromSnapshot(state.GetSnapshot())
+ client := &slotDiskPVEClient{}
+ client.setError(errors.New("disks/list timed out"))
+ started := time.Now()
+ m.maybePollPhysicalDisksAsync(context.Background(), "pve1", &config.PVEInstance{}, client,
+ []proxmox.Node{{Node: "node1", Status: "online"}}, map[string]string{"node1": "online"}, nil)
+ var disks []models.PhysicalDisk
+ for deadline := time.Now().Add(3 * time.Second); ; time.Sleep(10 * time.Millisecond) {
+ if snapshot := state.GetSnapshot(); snapshot.LastUpdate.After(started) {
+ disks = snapshot.PhysicalDisks
+ break
+ }
+ if time.Now().After(deadline) {
+ t.Fatal("physical disk poll with a failing disk query did not land in state")
+ }
+ }
+ byDevice := map[string]models.PhysicalDisk{}
+ for _, disk := range disks {
+ byDevice[disk.DevPath] = disk
+ }
+ if len(disks) != 1 {
+ t.Fatalf("disks = %+v, want only the row that was not split", disks)
+ }
+ if split, listed := byDevice["/dev/sda"]; listed {
+ t.Fatalf("the agent's row stood in for the disk the operator split from it: %+v", split)
+ }
+ if other := byDevice["/dev/sdb"]; other.Serial != "SERIAL-B" || other.Temperature != 62 || !other.AgentSMARTReported ||
+ other.ID != unifiedresources.ProxmoxPhysicalDiskSourceID("pve1", "node1", "/dev/sdb", "", "") {
+ t.Fatalf("the other row did not stand in for its disk: %+v", other)
+ }
+}
+
+// splitDecidingStore is the resource store a monitor test hands out when it
+// wants to decide the operator's splits itself.
+type splitDecidingStore struct {
+ *unifiedresources.MonitorAdapter
+ splits *fakeDiskAgentSplits
+}
+
+func (s splitDecidingStore) ProxmoxDiskAgentSMARTSplit(disk models.PhysicalDisk, host models.Host, smart models.HostDiskSMART) bool {
+ return s.splits.ProxmoxDiskAgentSMARTSplit(disk, host, smart)
+}
+
+// The node poll takes the node's SMART sensor list from a linked agent when
+// the agent's report carries a usable temperature, and from the SSH collector
+// otherwise, so only the first kind of reading is the agent's row of the disk
+// a split Proxmox disk was split from. The legacy NVMe list names no disk, so
+// a split disk drops its guess either way. A disk whose temperature has
+// another source keeps it, and the caller's collection is never modified.
+func TestDropNodeSensorTemperatureRemovesOnlyAgentSuppliedReadings(t *testing.T) {
+ for _, tc := range []struct {
+ source string
+ smartFromAgent bool
+ dropped bool
+ }{
+ {proxmoxNodeSMARTTemperatureSource, true, true},
+ {proxmoxNodeSMARTTemperatureSource, false, false},
+ {proxmoxNodeNVMeTemperatureSource, true, true},
+ {proxmoxNodeNVMeTemperatureSource, false, true},
+ } {
+ shared := &diskinventory.CollectionStatus{
+ Temperature: diskinventory.Available(tc.source), Serial: diskinventory.Available("proxmox_disks"),
+ IO: diskinventory.Unsupported("proxmox_disks", "no counters"), Controller: diskinventory.Missing("proxmox_disks", "none"),
+ Pool: diskinventory.Available("proxmox_zfs"),
+ }
+ disk := models.PhysicalDisk{Temperature: 60, Collection: shared}
+ dropNodeSensorTemperature(&disk, tc.smartFromAgent)
+ if tc.dropped {
+ other := *disk.Collection
+ other.Temperature = shared.Temperature
+ if disk.Temperature != 0 || disk.Collection.Temperature.State != diskinventory.FieldUnsupported ||
+ disk.Collection.Temperature.Source != "proxmox_disks" || other != *shared {
+ t.Fatalf("%+v: reading not dropped cleanly: %+v / %+v", tc, disk, disk.Collection)
+ }
+ } else if disk.Temperature != 60 || disk.Collection != shared {
+ t.Fatalf("%+v: an SSH-supplied reading was dropped: %+v", tc, disk)
+ }
+ if shared.Temperature.State != diskinventory.FieldAvailable || shared.Temperature.Source != tc.source {
+ t.Fatalf("%+v: the caller's collection was modified: %+v", tc, shared)
+ }
+ }
+ for _, collection := range []*diskinventory.CollectionStatus{
+ nil,
+ {Temperature: diskinventory.Available("smartctl")},
+ {Temperature: diskinventory.Unsupported("proxmox_disks", "no temperature")},
+ } {
+ disk := models.PhysicalDisk{Temperature: 60, Collection: collection}
+ dropNodeSensorTemperature(&disk, true)
+ if disk.Temperature != 60 || disk.Collection != collection {
+ t.Fatalf("a reading from another source was dropped: %+v", disk)
+ }
+ }
+}
+
+// mergeNVMeTempsIntoDisks labels what it takes from the node's sensor lists
+// with the sources dropNodeSensorTemperature recognises: the SMART list
+// matched by identity or path, and the legacy NVMe list matched by order.
+func TestMergeNVMeTempsLabelsReadingsWithTheNodeSensorSources(t *testing.T) {
+ node := func(temperature *models.Temperature) []models.Node {
+ return []models.Node{{Name: "node1", Temperature: temperature}}
+ }
+ disk := models.PhysicalDisk{Node: "node1", DevPath: "/dev/nvme0n1", Serial: "S6B0NL0W123456", Type: "nvme"}
+
+ bySMART := mergeNVMeTempsIntoDisks([]models.PhysicalDisk{disk}, node(&models.Temperature{
+ Available: true, HasSMART: true,
+ SMART: []models.DiskTemp{{Device: "/dev/nvme0n1", Serial: "S6B0NL0W123456", Temperature: 55}},
+ }))[0]
+ if bySMART.Temperature != 55 || bySMART.Collection == nil || bySMART.Collection.Temperature.Source != proxmoxNodeSMARTTemperatureSource {
+ t.Fatalf("SMART list reading not labelled %q: %+v / %+v", proxmoxNodeSMARTTemperatureSource, bySMART, bySMART.Collection)
+ }
+
+ for name, row := range map[string]models.DiskTemp{
+ "WWN": {Device: "/dev/other", WWN: "0x5000c500a1b2c3d4", Temperature: 52},
+ "device path": {Device: "/dev/nvme0n1", Temperature: 53},
+ } {
+ wwnDisk := models.PhysicalDisk{Node: "node1", DevPath: "/dev/nvme0n1", WWN: "0x5000c500a1b2c3d4", Type: "nvme"}
+ if name == "device path" {
+ wwnDisk = models.PhysicalDisk{Node: "node1", DevPath: "/dev/nvme0n1", Type: "nvme"}
+ }
+ got := mergeNVMeTempsIntoDisks([]models.PhysicalDisk{wwnDisk}, node(&models.Temperature{
+ Available: true, HasSMART: true, SMART: []models.DiskTemp{row},
+ }))[0]
+ if got.Temperature != row.Temperature || got.Collection == nil || got.Collection.Temperature.Source != proxmoxNodeSMARTTemperatureSource {
+ t.Fatalf("%s match not labelled %q: %+v / %+v", name, proxmoxNodeSMARTTemperatureSource, got, got.Collection)
+ }
+ }
+
+ byOrder := mergeNVMeTempsIntoDisks([]models.PhysicalDisk{disk}, node(&models.Temperature{
+ Available: true, HasNVMe: true, NVMe: []models.NVMeTemp{{Device: "nvme0", Temp: 47}},
+ }))[0]
+ if byOrder.Temperature != 47 || byOrder.Collection == nil || byOrder.Collection.Temperature.Source != proxmoxNodeNVMeTemperatureSource {
+ t.Fatalf("legacy NVMe reading not labelled %q: %+v / %+v", proxmoxNodeNVMeTemperatureSource, byOrder, byOrder.Collection)
+ }
+}
+
+// Only a SMART report that carries a usable temperature makes the node's SMART
+// list the agent's (mergeTemperatureData).
+func TestHostSuppliesNodeSMARTTemperaturesFollowsUsableReadings(t *testing.T) {
+ host := func(rows ...models.HostDiskSMART) models.Host {
+ return models.Host{Sensors: models.HostSensorSummary{SMART: rows}}
+ }
+ for name, tc := range map[string]struct {
+ host models.Host
+ want bool
+ }{
+ "a reading": {host(models.HostDiskSMART{Device: "sda", Temperature: 40}), true},
+ "one reading of several": {host(models.HostDiskSMART{Device: "sda"}, models.HostDiskSMART{Device: "sdb", Temperature: 40}), true},
+ "no temperature": {host(models.HostDiskSMART{Device: "sda"}), false},
+ "standby row": {host(models.HostDiskSMART{Device: "sda", Temperature: 40, Standby: true}), false},
+ "negative reading": {host(models.HostDiskSMART{Device: "sda", Temperature: -1}), false},
+ "no rows": {host(), false},
+ } {
+ if got := hostSuppliesNodeSMARTTemperatures(tc.host); got != tc.want {
+ t.Errorf("%s: got %v, want %v", name, got, tc.want)
+ }
+ }
+}
+
+// When the linked agent's SMART report carries no usable temperature, the
+// node's SMART sensor list comes from the SSH collector, so a reading of a
+// split Proxmox disk taken from it is the node's own and stays, while the
+// agent's row still takes nothing else from the disk.
+func TestMergeHostAgentSMARTIntoDisksKeepsSSHNodeSensorReadingOfSplitDisk(t *testing.T) {
+ nodes := []models.Node{{Name: "node1", LinkedAgentID: "agent-1"}}
+ hosts := []models.Host{{ID: "agent-1", Status: "online", Sensors: models.HostSensorSummary{
+ SMART: []models.HostDiskSMART{{Device: "sda", Serial: "SERIAL-A", Type: "sata", Health: "FAILED"}},
+ }}}
+ disk := models.PhysicalDisk{
+ ID: "pve1-node1-/dev/sda", Node: "node1", Instance: "pve1", DevPath: "/dev/sda", Serial: "SERIAL-A", Type: "sata",
+ Health: "PASSED", Wearout: 100, Temperature: 52,
+ Collection: &diskinventory.CollectionStatus{Temperature: diskinventory.Available(proxmoxNodeSMARTTemperatureSource)},
+ }
+ splits := &fakeDiskAgentSplits{splitDevPaths: map[string]bool{"/dev/sda": true}}
+ got := mergeHostAgentSMARTIntoDisks([]models.PhysicalDisk{disk}, nodes, hosts, splits)[0]
+ if got.Temperature != 52 || got.Collection.Temperature.Source != proxmoxNodeSMARTTemperatureSource ||
+ got.Health != "PASSED" || got.AgentSMARTReported || !got.AgentSMARTSplit {
+ t.Fatalf("split disk with an SSH-supplied reading: %+v / %+v", got, got.Collection)
+ }
+
+ // An agent that stopped reporting keeps its rows, temperatures included,
+ // but the node poll ignores them once its lease lapsed, so the reading is
+ // the SSH collector's again.
+ hosts[0].Status = "offline"
+ hosts[0].Sensors.SMART[0].Temperature = 61
+ lapsed := mergeHostAgentSMARTIntoDisks([]models.PhysicalDisk{disk}, nodes, hosts, splits)[0]
+ if lapsed.Temperature != 52 || lapsed.Collection.Temperature.Source != proxmoxNodeSMARTTemperatureSource || !lapsed.AgentSMARTSplit {
+ t.Fatalf("split disk with a lapsed agent dropped the node's own reading: %+v / %+v", lapsed, lapsed.Collection)
+ }
+ hosts[0].Status = "online"
+ live := mergeHostAgentSMARTIntoDisks([]models.PhysicalDisk{disk}, nodes, hosts, splits)[0]
+ if live.Temperature != 0 || live.Collection.Temperature.State != diskinventory.FieldUnsupported {
+ t.Fatalf("split disk with a reporting agent kept the agent-supplied reading: %+v / %+v", live, live.Collection)
+ }
+}
diff --git a/internal/unifiedresources/physical_disk_agent_split.go b/internal/unifiedresources/physical_disk_agent_split.go
new file mode 100644
index 0000000000..3527f023ca
--- /dev/null
+++ b/internal/unifiedresources/physical_disk_agent_split.go
@@ -0,0 +1,67 @@
+package unifiedresources
+
+import "github.com/rcourtman/pulse-go-rewrite/internal/models"
+
+// ProxmoxDiskAgentSMARTSplit reports whether the operator split a Proxmox
+// disk observation from the disk a host agent reports in one SMART row:
+// report-merge on the merged disk (the drawer's Split merged resource)
+// recorded an exclusion that separates them by the rule the linked disk join
+// applies (physicalDiskSplitLocked). The PVE disk poller asks before it pairs
+// the agent's row with the Proxmox disk on the agent's node, so a split
+// Proxmox row carries what Proxmox reported and the PVE disk check judges it.
+//
+// It reads the exclusions this generation loaded, and whether it holds the two
+// observations as one disk, never what the poller's pairing would fill into
+// the Proxmox row: the pairing re-keys a Proxmox disk whose serial it fills or
+// promotes, so a decision read from those fields would flip with it. The
+// generation holds them as one disk only through a manual link, which is the
+// operator's later decision, so pairing resumes while it stands, and the link's
+// removal or a new report-merge splits them again. A registry without a store
+// carries no operator decisions. It takes no lock monitoring holds.
+func (a *MonitorAdapter) ProxmoxDiskAgentSMARTSplit(disk models.PhysicalDisk, host models.Host, smart models.HostDiskSMART) bool {
+ registry := a.currentRegistry()
+ if registry == nil {
+ return false
+ }
+ return registry.proxmoxDiskAgentSMARTSplit(disk, host, smart)
+}
+
+// proxmoxDiskAgentSMARTSplit judges the pair as the linked disk join would:
+// the Proxmox observation by its source-specific candidate ID (its slot) and
+// the identity Proxmox reported, the agent's disk by the ID this generation
+// gave it, or, absent from it, by the identity its row reports.
+func (rr *ResourceRegistry) proxmoxDiskAgentSMARTSplit(disk models.PhysicalDisk, host models.Host, smart models.HostDiskSMART) bool {
+ proxmoxSourceID := normalizeSourceID(disk.ID)
+ agentSourceID := normalizeSourceID(HostSMARTDiskSourceID(host, smart))
+ if proxmoxSourceID == "" || agentSourceID == "" {
+ return false
+ }
+
+ rr.mu.RLock()
+ defer rr.mu.RUnlock()
+ if len(rr.exclusions) == 0 {
+ return false
+ }
+ agentDiskID := rr.bySource[SourceAgent][agentSourceID]
+ if agentDiskID != "" && agentDiskID == rr.bySource[SourceProxmox][proxmoxSourceID] {
+ return false
+ }
+ agentDisk := rr.resources[agentDiskID]
+ if agentDisk == nil {
+ resource, identity := resourceFromHostSMARTDisk(host, smart)
+ resource.Identity = identity
+ // A row without hardware identity takes its candidate ID, which
+ // report-merge records for it, as the merged disk's ID.
+ resource.ID = rr.sourceSpecificID(ResourceTypePhysicalDisk, SourceAgent, agentSourceID)
+ if hostID := rr.bySource[SourceAgent][normalizeSourceID(host.ID)]; hostID != "" {
+ resource.ParentID = &hostID
+ }
+ agentDisk = &resource
+ }
+ observation, identity := resourceFromPhysicalDisk(disk)
+ observation.Identity = identity
+ if nodeID := rr.bySource[SourceProxmox][proxmoxNodeSourceID(disk.Instance, disk.Node)]; nodeID != "" {
+ observation.ParentID = &nodeID
+ }
+ return rr.physicalDiskSplitLocked(agentDisk, &observation, rr.sourceSpecificID(ResourceTypePhysicalDisk, SourceProxmox, proxmoxSourceID))
+}
diff --git a/internal/unifiedresources/registry_merge_policy_test.go b/internal/unifiedresources/registry_merge_policy_test.go
index d8bb80ed7c..b10e66d7d8 100644
--- a/internal/unifiedresources/registry_merge_policy_test.go
+++ b/internal/unifiedresources/registry_merge_policy_test.go
@@ -4243,7 +4243,9 @@ func TestPhysicalDiskExclusionFallbackStaysPerMachine(t *testing.T) {
// on every rebuild. The registry ingests agent disks first, so the agent's
// row holds the merged ID and keeps it; the Proxmox row takes the ID it holds
// alone, or its source-specific ID where both share a hardware identity (the
-// agent holds that ID), as findMatch's excluded branch does.
+// agent holds that ID), as findMatch's excluded branch does. The PVE disk
+// poller asks ProxmoxDiskAgentSMARTSplit before it pairs the agent's SMART
+// row with the Proxmox disk, and it answers as the exclusions split the rows.
func TestOperatorSplitSeparatesDisksJoinedInsideALinkedHost(t *testing.T) {
now := time.Now().UTC()
for _, shape := range []struct {
@@ -4331,6 +4333,15 @@ func TestOperatorSplitSeparatesDisksJoinedInsideALinkedHost(t *testing.T) {
t.Fatalf("fixture did not join the disks under the agent's ID: merged %q, alone: agent %q, proxmox %q", merged, agentAlone, pveAlone)
}
ids := diskSplitCandidates(t, adapter.currentRegistry(), merged)
+ // The PVE disk poller asks the adapter before it pairs the
+ // agent's SMART row with the Proxmox disk on the agent's node.
+ pollerSplit := func(step string, host models.Host, smart models.HostDiskSMART, want bool) {
+ t.Helper()
+ if got := adapter.ProxmoxDiskAgentSMARTSplit(shape.pve, host, smart); got != want {
+ t.Fatalf("%s: poller split = %v, want %v", step, got, want)
+ }
+ }
+ pollerSplit("before the request", host, shape.agent, false)
addExclusions(t, store, request.exclusions(ids))
want := linkedDiskRows{joined: merged}
@@ -4371,6 +4382,13 @@ func TestOperatorSplitSeparatesDisksJoinedInsideALinkedHost(t *testing.T) {
check, describe := exactly(want)
assertViews("after the request", snapshot, check, describe)
+ pollerSplit("after the request", host, shape.agent, request.split)
+ // A generation that has not ingested the agent's disk yet judges
+ // its row by the ID and identity the row would be keyed under.
+ unseen := NewMonitorAdapter(NewRegistry(store))
+ if got := unseen.ProxmoxDiskAgentSMARTSplit(shape.pve, host, shape.agent); got != request.split {
+ t.Fatalf("a generation without the agent's disk judged the split = %v, want %v", got, request.split)
+ }
if !request.split {
return
}
@@ -4383,6 +4401,11 @@ func TestOperatorSplitSeparatesDisksJoinedInsideALinkedHost(t *testing.T) {
}
check, describe = exactly(linkedDiskRows{joined: merged})
assertViews("after relink", snapshot, check, describe)
+ // The link is the operator's later decision, whether it
+ // replaced an exclusion (the Proxmox row held its candidate
+ // ID) or left it standing: the generation holds the
+ // observations as one disk, so the poller pairs them again.
+ pollerSplit("after relink", host, shape.agent, false)
relinked := adapter.currentRegistry()
var again [][2]string
for _, fold := range relinked.ManualLinkFolds(merged) {
@@ -4393,6 +4416,22 @@ func TestOperatorSplitSeparatesDisksJoinedInsideALinkedHost(t *testing.T) {
addExclusions(t, store, again)
check, describe = exactly(want)
assertViews("after splitting again", snapshot, check, describe)
+ pollerSplit("after splitting again", host, shape.agent, true)
+
+ // The split names the IDs of the disks it separated, not the
+ // Proxmox slot, so a replacement in the slot (different
+ // hardware on both sides) is a different disk the poller pairs.
+ replacedPVE, replacedAgent := shape.pve, shape.agent
+ replacedPVE.Serial = "REPLACEMENT-0009"
+ replacedAgent.Serial = "Z9Z9REPLACED"
+ if shape.pve.Serial == shape.agent.Serial {
+ replacedAgent.Serial = replacedPVE.Serial
+ }
+ replacedHost := host
+ replacedHost.Sensors.SMART = []models.HostDiskSMART{replacedAgent}
+ if adapter.ProxmoxDiskAgentSMARTSplit(replacedPVE, replacedHost, replacedAgent) {
+ t.Fatalf("a replacement in the slot inherited the split recorded against the disk it replaced")
+ }
// smartctl reads no serial from a disk in standby, so the
// agent's row takes its device-keyed ID. A Proxmox
@@ -4405,8 +4444,10 @@ func TestOperatorSplitSeparatesDisksJoinedInsideALinkedHost(t *testing.T) {
assertViews("while the agent's disk is in standby", asleep, func(got linkedDiskRows) bool {
return apart(got) && got.proxmox == merged
}, "the disks apart, the Proxmox row on "+merged)
+ pollerSplit("while the agent's disk is in standby", asleep.Hosts[0], asleep.Hosts[0].Sensors.SMART[0], true)
check, describe = exactly(want)
assertViews("once the agent's disk wakes", snapshot, check, describe)
+ pollerSplit("once the agent's disk wakes", host, shape.agent, true)
}
// A same-serial disk on another machine re-keys the agent's
@@ -4414,6 +4455,7 @@ func TestOperatorSplitSeparatesDisksJoinedInsideALinkedHost(t *testing.T) {
// the unscoped ID, still holds.
if shape.agent.Serial != "" {
assertViews("after a same-serial disk appears elsewhere", withClone, apart, "the disks apart")
+ pollerSplit("after a same-serial disk appears elsewhere", host, shape.agent, true)
}
})
}
@@ -4451,6 +4493,9 @@ func TestOperatorSplitSeparatesDisksJoinedInsideALinkedHost(t *testing.T) {
t.Fatalf("%s rebuild %d %s: got %+v, want the disks apart", step.name, rebuild, view, got)
}
}
+ if !adapter.ProxmoxDiskAgentSMARTSplit(shape.pve, host, shape.agent) {